Datasheet K244XP-2, K244GR-2 Specification

Page 1
Proximity switches
Photoelectric switches Proximity switches
LIMIT SWITCHES
PROXIMITY SWITCHES
PHOTOELECTRIC SWITCHES
Limit switches
Limit switches
LOW
VOLTAGE
EQUIPMENT
Up to 600 Volts
Photoelectric switches
Proximity switchesProximity switches
INDIVIDUAL CATALOG
from D&C CATALOG 20th Edition
01 02 03 04 05 06 07 08 09 10 11 12
05
Page 2
Limit switches, Proximity switches
05
Photoelectric switches
Page
Limit Switches General information ...................................................................................... 05/1
AL and AL-S .................................................................................................05/2
K244 ........................................................................................................ 05/16
K244 reversing roller .....................................................................................05/21
HK244 and WK244 .......................................................................................05/23
Proximity Switches General information ...................................................................................... 05/25
Inductive type PE-U12D and PE-U25NT ..................................................05/28
PE1-C, PE1-Y ....................................................................05/29
PE-B .................................................................................. 05/33
PE-X15D ............................................................................05/36
PE-T ..................................................................................05/37
PE-L ...................................................................................05/39
PE2-C ................................................................................05/43
PE-X3D ..............................................................................05/47
PE-G4D ............................................................................. 05/48
Magnetically operated reed switch type
PM ..................................................................................... 05/49
PM1U .................................................................................05/50
AES ...................................................................................05/52
AER ................................................................................... 05/53
Photoelectric Switches General information ...................................................................................... 05/54
PH1C ............................................................................................................ 05/56
PH4C ............................................................................................................ 05/61
PH8AU .......................................................................................................... 05/65
Page 3
MINIMUM ORDERS
Orders amounting to less than ¥10,000 net per order will be charged as ¥10,000 net per order plus freight and other charges.
WEIGHTS AND DIMENSIONS
Weights and dimensions appearing in this catalog are the best information available at the time of going to press. FUJI ELECTRIC FA has a policy of continuous product improvement, and design changes may make this information out of date. Please confirm such details before planning actual construction.
INFORMATION IN THIS CATALOG IS SUBJECT TO CHANGE WITHOUT NOTICE.
Page 4
Limit switches, AL and K244 series
Description
FUJI AL and K244 series limit switches have wide application in such industrial equipment as machine tools, printing machines, and transfer machines. These switches feature a sturdy aluminum die­cast housing that is highly resistant to oil, water, and dust, and long mechanical life — 10 million operations minimum.
AL series
AL and AL-S series limit switches feature a forced contact opening mechanism. Under abnormal conditions, the mechanism forces the contacts open to prevent pitting and fusing. Gold-plated silver contacts with scrubbing action have high reliability.
KKD07-027 SF-2025 SK-580
AL-SK
K244-xP-2 K244-gR-2
K244 series
The K244 series is provided with four kinds of contact operating action: standard normal stroke, snap action, make-before-break, and extended stroke. WK244 of the K244 series has bifurcated contacts, while HK244 features a scrubbing action mechanism. These limit switches can be used in low-level circuits of 3V, 5mA.

Limit Switches

General information

05
Selection guide
Basic type AL AL-S K244 HK244 WK244
Rated voltage (max.) 550V AC, 250V DC* Rated thermal current 10A (5A*1) 10A Operating cycles per hour 7,200 3,000 Expected life Mechanical 10 millions 10 millions 10 millions 10 millions
(operations) Electrical 100,000 1 million*
Contact arrangement 1NO+1NC 1NO+1NC, 2NO+2NC Contact Single button Single button Bifurcated Degree of protection (IEC) IP67 – Features Forced contact opening mechanism as A wide variety of contact operating action
Page
*1: For snap action type *2: 400,000 for snap action type
Standard Compact type Standard For low-level circuit For low-level circuit
1
(at 125V AC, 5A res. load for snap action (at 220V AC, (at 220V AC, (at 220V AC, type) 10A res. load) 10A res. load) 2.5A res. load)
standard Highly reliable gold-plated silver contacts Sealed types for oily and wet environments
05/2 05/16 05/23 05/23
550V AC/DC
2
400,000 500,000
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/1
Page 5
Limit Switches
AL and AL-S General information
Forced contact opening limit switches, AL and AL-S series
Description
The AL and AL-S series limit switches feature a forced contact opening mechanism. This mechanism prevents contact welding and subsequent malfunctioning. These series therefore result in extremely dependable system controls. The AL series is available in standard sizes and the AL-S series is compact versions of the AL types.
Features
• The forced contact opening mechanism is provided so as to overcome contact problems.
• Gold-plated contacts and a self cleaning action ensure contact reliability.
• Sealed construction Double oil seals prevent moving parts and contacts from being contaminated by exterior oil, grime and grease, an advantage in dirty industrial locations.
• Operational mode indicator can replace existing cover with lamp indicator cover when required. An LED or neon lamp is used depending on supply voltage.
• Contact mechanical design Contact operating mechanisms can be selected according to the application­snap, overlap and normal actions
• Conform to IEC Standard
Roller
Operating head
Operating lever Actuating shaft
Plunger assembly
AL-N1
AL-SP2
SI-1022
SI-204
Forced operating mechanism
Rubber packing
Cover
Forced contact opening
mechanism
This mechanism does not operate under normal conditions. However, when the switch plunger overtravels under abnormal conditions the mehcanism comes into operation and forcibily opens the NC contacts thus preventing contact welding. This action improves the dependability of electrical systems.
SK-415
SK-416
Plunger
Switching is carried out at the normal operating position
Normal operating condition
Plunger
SK-417
Normal operating position
Contact ratings
Contact Thermal Make and break current * action current AC DC
Voltage Resistive Inductive Voltage Resistive Inductive
(A) (V) (A) (A) (V) (A) (A)
Snap 5 125 5 3 30 or less 5 3
250 3 2 125 0.4 0.05 500 1 0.6 250 0.2 0.03
Normal 10 24 10 10 24 7 7 Overlap 110 10 10 110 1.5 0.9
220 10 10 220 0.63 0.28 440 5 5 440 0.28 0.14 550 3 3 550 0.22 0.1
*: When NO and NC contacts are wired in the same potential.
UL listed (File No. E44592)
Contact ratings
AC (B300) DC Voltage Operational current (A) Voltage Operational current (Res. load) (V) Make Break (V) (A)
120 30 3 30 5 240 15 1.5 125 0.4
250 0.2
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
05/2
Free position
The mechanism operates to open the contacts when the plunger overtravels
Abnormal condition
Normal operating position
Overtravel position
Technical data
Insulation resistance:
Over 100M at 500V DC
Life expectancy
Mechanical: Over 10 million operations Electrical: Snap action type
100,000 operations at 125V AC 5A res. load
Normal action type
100,000 operations at 110V AC 10A res. load
Allowable ambient temperature:
–10°C to +80°C
Degree of protection: IEC IP67
Information subject to change without notice
Page 6
Limit Switches
AL and AL-S
General information
Directional contact operation
AL-N1, AL-N2 and AL-N3 can be modified in their operational directions. They will switch in both directions, or in only one direction, either clockwise or counterclockwise. The adjustment is easily carried out by removing the operating head and changing the plunger as shown in the photograph. After the plunger has been reassembled, replace the head and tighten the screws. Check operation by moving the arm in the desired direction.
Standard operating position
Operates Operates
SK-411
Both
Operates
directions
Operates
Adjustment of operating lever
Loosen the locking screw, turn over the lever and then retighten at the required position. Type: AL-N1, AL-N2, AL-N3, AL-SN1, AL-SN2, AL-SN3, AL-F1.
By loosening this screw, the actuator can be fixed at any position within 360°
Adjustment of lever length
Loosen the adjustment screw, adjust the length and retighten.
Usable by deforming the rod; however, pay attention to minimum bending radius of rod. The minimum bending radius is
AL-N2: 25-90mm
AL-SN2: 25-70mm
Adjust lever by loosening this hexagonal bolt
AL-N3: 25-141mm
2mm
AL-SN3: 25-130mm
Adjust rod length by loosening this screw.
Cable connection
Refer to the wiring diagram for connection. When connecting to conduit remove the plastic packing piece.
34
12
Rubber packing
Packing holder
2
, 4-core,
0.75mm finished external diameter‚ ø9.9, vinyl cabtyre cable
Rubber packing
PF 1/2 lock nut
JIS C 8305
Contact:1-2 Normally closed
3-4 Normally open
Mounting
AL type limit switches can be attached either from the front or the back. In the case of front mounting type clamp at 4 positions using M5 screws. When attaching from the back of the panel tighten at 4 positions by means of M6 screws. The thread depth of the switch body is 15mm.
05
SK-413
Counter­clockwise
Clockwise directions
directions
Changing direction of operating
head
SK-412
AL-N2 AL-N3 AL-SN2 AL-SN3
Roller installable on inner side
AL-N1, SN1 AL-N2, SN2, SN5
The operating head direction can be changed through 90° after having removed the screw. Care must be taken because the contact action changes according to the direction of the plunger
Change the direction by loosening bolt
assembly. Check for correct assembly after each step has been completed. Limit switches with adjustable head direction are AL-N1, AL-N2, AL-N3, AL­SN1, AL-SN2 and AL-SN3. In the case
Dimensions:
See pages 05/13 to 05/15.
of AL-P2 and AL-SP2, the head direction of a top push roller plunger type can be shifted 90° in either direction.
Ordering information
Specify the following:
1.Type number or ordering code
SK-410SK-409
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Change the direction by removing bolt
M5, minimum length 35mm, plus pan-head
28.5
screw, flat-head screw, bolt with hexagonal hole
M6
15
Front mounting Rear mounting
05/3
Page 7
Limit Switches
AL and AL-S General information
Type number nomenclature
AL–N1 1 H1 UL
Ordering code
PL 1 A–1 A ZU
UL approved Lamp voltage
A2 : 5 to 8V (LED) B2 : 10 to 15V (LED) E2 : 18 to 24V (LED) H1 : 110 to 220V (Neon)
Contact action
1 : Snap action 2 : Normal action 3 : Overlap action 1S : Snap action (Sealed contact)
Type of actuator
N1 : Roller lever N2 : Adjustable length roller lever N3 : Adjustable length rod lever N5 :
Adjustable length roller lever (Rubber roller) P1 : Top push rod plunger P2 : Top push roller plunger P3 : Top ball push rod plunger F1 : Fork roller lever S1 : Wobble head coil spring rod S2 : Wobble plastic head spring rod W1 : Wobble head with cat’s whisker Y1 : Side push rod plunger Y2 : Side push roller plunger Y3 : Side ball push rod plunger
AL : Standard type AL-S : Compact type
Operating and definitions (for snap action type)
Rotary actuation Plunger actuation
OP
TTP
2
FP: Free Position
This is the position where there is no load on the actuator.
OP: Operating Position
This is the position where the actuator travels from the free position to NO contact closes.
TTP: Total Travel Position
This is the furthest position where the actuator can travel to after passing the OP without damage to the limit switch.
RP: Release Position
This is the position where the contact resets after the actuator has travelled from OP.
PT: Preoperating Travel
This indicates the travelling angle or distance from FP to OP.
OT: Overtravel
This indicates the travelling angle or distance from OP to TTP.
TT
1
PT
MD
RP
FP
TT
1
RP
Actuating shaft
OP
Pre travel (PT)
TTP
2
OTOT
Switch plunger
Plunger bushing
A
Free position (FP)
33
PT
MD
TT: Total Travel
This indicates the travelling angle or distance from FP to TTP.
MD: Movement Differential (Travel to Reset)
This indicates the travelling angle or distance from OP to the position where the contact resets.
OF: Required Operating Force
This indicates the minimum operating force which is required for the contact to close.
RF: Required Resetting Force
This indicates the force required for the contact to reset.
TF: Full Overtravel Force
This indicates the force required for the actuator to travel from FP to TTP.
UL approved Lamp voltage
A : LED 5 to 8V B : LED 10 to 15V E : LED 18 to 24V D : Neon
Contact action
1 : Snap action 2 : Normal action 3 : Overlap action
Type of actuator
A : Roller lever B : Adjustable length roller lever C : Adjustable length rod lever D : Top push rod plunger E : Top push roller plunger F : Top ball push rod plunger G : Fork roller lever H : Wobble head coil spring rod J : Wobble plastic head spring rod K : Wobble head with cat’s whisker L : Side push rod plunger M : Side push roller plunger N : Side ball push rod plunger R:
Adjustable length roller lever (Rubber roller)
Series
1 : Standard type 2 : Compact type
Limit switch
Movement characteristics Overtravel
(OT)
1
B Operating position (OP)
Position of plunger
1
Required operating force (OF)
Movement diffrential (MD)
2
C
Total travel position (TTP)
2
Full overtravel force (TF)
Forces acting on plunger
3
D Release position (RP)
3
Required release force (RF)
Total travel (TT)
A
C
B
D
05/4
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 8
Limit Switches
Actuate AL-SP1 type in direction coinciding with plunger shaft direction
61.5
ø
17.5
roller
75° or less
45° or less
ø70
When actuating switch beyond this range, contact may make/break two times or more
AL and AL-S
Actuating slider face angle and approach speed Standard type
Type AL-N1 AL-N2 AL-N3 AL-F1 AL-S1 AL-P1 AL-P2 AL-P3 Slider angle (degree) 30 45 30 45 45 30 30 Slider approach Maximum (meter/second) 0.5 0.2 0.2 0.1 0.2 0.2 0.2 0.2 0.3 0.3
speed Minimum (millimeter/second) 0.1 0.1 0.2 0.2 0.2 0.1 0.2 0.1 0.1 0.1 AL-N1 AL-N2 AL-N3 AL-F1
Determine slider depth within range of these dimensions
14.7
Slider
45° or less
ø
17.5
roller
75° or less
25-90
Determine slider depth within range of these dimensions
Slider
75° or less
Rod can be deformed, however,
141
-
minimum bending
25
radial (R) is 2mm
14.7
R
R
R
61.5
90°
20-30
ø17.5 roller
Apply slider over entire width of rolle
Slider
Slider
45°or less
AL-S1 AL-P1 AL-P2 AL-P3
ø
17 roller
36
Actuate AL-P1 type in
46
Slider
30° or less
46.4
direction coinciding with plunger shaft direction
Ball
Slider
30° or less
Compact type
Type AL-SN1 AL-SN2, SN5 AL-SN3 AL-SK1 AL-SK2 AL-SS1 AL-SP1 AL-SP2 Slider angle (degree) 30 45 30 45 30 45 30 Slider approach Maximum (meter/second) 0.5 0.2 0.2 0.1 0.2 1: 0.6 0.5 0.2 0.2 0.3
speed 2: 0.2 —
Minimum (millimeter/second) 0.1 0.1 0.2 0.2 0.2 1: 0.1 0.1 0.2 0.1 0.1
AL-SN1 AL-SN2, SN5 AL-SN3 AL-SK1
70° or less
45° or less
70° or less
45° or less
70° or less
2: 0.1 —
30° or less
2 1
45° or less
05
AL-SK2 AL-SS1 AL-SP1 AL-SP2
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
30° or less
45° or less
When actuating
ø70
2
1
switch beyond this range, contact may make/break two times or more
30° or less
05/5
Page 9
Limit Switches
AL and AL-S
AL series
Description
Roller lever
• The angle from the free position to the maximum travel position is 75°
• Spring return
• The most popular limit switch which is best suited for machine tools, automatic machines, conveyor control and similar applications.
Type Ordering code
AL-N11 PL1A-1 AL-N12 PL1A-2 AL-N13 PL1A-3
SI-204 SI-208
AL-N11UL PL1A-1ZU Adjustable length roller lever
• The lever length can be adjusted between 25mm and 90mm.
• Spring return
• The graduated scales on the lever facilitate adjustment
Type Ordering code
AL-N21 PL1B-1 AL-N22 PL1B-2 AL-N23 PL1B-3 AL-N21UL PL1B-1ZU
SI-203 SI-205
Adjustable length rod lever
• The ø3.2mm stainless steel rod can be extended up to 141mm max.
• Spring return
• The rod can be used by bending. (Radial 2mm min.)
Type Ordering code
AL-N31 PL1C-1 AL-N32 PL1C-2 AL-N33 PL1C-3 AL-N31UL PL1C-1ZU
SI-202 SI-211
Top push rod plunger
• Operated by a vertical rod plunger
• Momentary action
Type Ordering code
AL-P11 PL1D-1 AL-P12 PL1D-2 AL-P13 PL1D-3 AL-P11UL PL1D-1ZU
SI-209 SI-212
Top push roller plunger
• This is a limit switch where the roller is attached to the plunger.
• The direction of the roller can be shifted 90°.
• This feature makes it highly suitable for the control of precision machinery.
• Momentary action
Type Ordering code
AL-P21 PL1E-1 AL-P22 PL1E-2 AL-P23 PL1E-3 AL-P21UL PL1E-1ZU
SI-207 SI-210
Description
Top ball push rod plunger
• The ball rod can be operated from any direction.
• The ball turns smoothly at all times.
• Best suited for detecting objects which travel horizontally from left to right or right to left while turning.
Type Ordering code
AL-P31 PL1F-1 AL-P32 PL1F-2 PL-P33 PL1F-3 AL-P31UL PL1F-1ZU
Fork roller lever
• The angle of the lever is 90°
• Maintained
• This limit switch is used when detecting the direction in which the lever inclines — i.e. in the right or left.
Type Ordering code
AL-F11 PL1G-1 AL-F11UL PL1G-1ZU
Side push rod plunger
• Push rod is attached to the side of the operating head.
• The operating head can be changed 90° in direction.
• Momentary action
• This limit switch is used to detect the end limit of low speed transfer.
Type Ordering code
AL-Y11 PL1H-1 AL-Y11UL PL1H-1ZU
Side push roller plunger
• The push roller is attached to the side of the operating head.
• Momentary action
• This is used to detect the position, speed and direction in high precision machinery and equipment.
Type Ordering code
AL-Y21 PL1J-1 AL-Y21UL PL1J-1ZU
Side ball push rod plunger
• The ball rod is attached to the side of the operating head.
• The ball turns smoothly in operation.
• Momentary action
• This limit switch is used to detect objects which travel horizontally from left to right or right to left while turning.
Type Ordering code
AL-Y31 PL1K-1 AL-Y31UL PL1K-1ZU
05/6
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 10
AL series
Description
SI-200 SI-199
Wobble head coil spring rod
• Operates by forces from any directions.
• Used in packing and other conveyors. Type Ordering code
AL-S11 PL1H-1 AL-S11UL PL1H-1ZU
Wobble plastic head spring rod
• The length of rod is 140mm from the head.
• Operates by forces from any directions.
Limit Switches
AL and AL-S
Description
Wobble head with cat’s whisker
• The length of the stainless steel rod is 190mm from the head.
• Can be operated from any direction.
• Require little torque
Type Ordering code
AL-W11 PL1N-1 AL-W11UL PL1N-1ZU
Type Ordering code
AL-S21 PL1M-1 AL-S21UL PL1M-1ZU
SI-201
05
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/7
Page 11
Limit Switches
AL and AL-S
Operating characteristics
Standard type (Snap action)
Type AL-N11 AL-N21*1AL-N31*2AL-P11 AL-P21 AL-P31 AL-F11
Required operating force OF (max.) 9N 9N 2.9N 15N 15N 15N 9.5N Required resetting force RF (min.) 0.5N 0.5N 0.15N 8.2N 8.2N 8.2N — Preoperating travel PT (min.) 12° 12° 12° 2mm 2mm 2mm 55° Overtravel OT (min.) 65° 65° 65° 5mm 5mm 5mm 35° Movement differential (Travel to reset) MD (max.) 7° 7° 7° 1mm 1mm 1mm — Total travel TT (min.) 75° 75° 75° ———90°±10°
Notes: *1At lever length 38mm
*2At rod lever length 135mm
AL-N11S AL-N21S*1AL-N31S*2AL-P11S AL-P21S AL-P31S AL-F11S
Type AL-Y11 AL-Y21 AL-Y31 AL-S11 AL-S21 AL-W11
AL-Y11S AL-Y21S AL-Y31S AL-S11S AL-S21S AL-W11S
Required operating force OF (max.) 40N 40N 40N 1.5N 1.5N 1.5N Required resetting force RF (min.) 8.9N 8.9N 8.9N — Preoperating travel PT (min.) 2.8mm 2.8mm 2.8mm 30mm 30mm 40mm Overtravel OT (min.) 4mm 4mm 4mm — Movement differential (Travel to reset) MD (max.) 1mm 1mm 1mm
Standard type (Normal action, overlap action)
Overlap actionNormal action
Type
Required operating force OF (max.) Movement to NC contact open Movement to NO contact closed Total travel TT (min., max.)
Notes: *1 At lever length 38mm
*2
At rod lever length 135mm
AL-N12 AL-N22
11N 28˚ 45˚ 75˚
*1
AL-N32
3.1N 28˚ 45˚ 75˚
*2
AL-P12 AL-P22 AL-P32AL
18N
3.5mm 5mm 7mm
AL-N13 AL-N23
11N 45˚ 28˚ 75˚
*1
AL-N33
3.1N 45˚ 28˚ 75˚
*2
AL-P13 AL-P23 AL-P33
18N 5mm
3.5mm 7mm
05/8
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 12
AL-S series/Compact-size
Description
Top push rod plunger
• Operated by a vertical rod plunger.
• Momentary action Type Ordering code
AL-SP11 PL2D-1 AL-SP12 PL2D-2 AL-SP13 PL2D-3
KKD07-032
AL-SP11UL PL2D-1ZU
Top push roller plunger
• This is a limit switch where the roller is attached to the plunger.
• The direction of the roller can be shifted 90°
• Momentary action
Type Ordering code
AL-SP21 PL2E-1 AL-SP22 PL2E-2 AL-SP23 PL2E-3 AL-SP21UL PL2E-1ZU
SI-1022
Top roller lever plunger
• This limit switch is used to detect objects which travel horizontally from left to right or right to left while turning.
• Used in packing and other conveyors.
Description
KKD07-028
KKD07-029
Limit Switches
AL and AL-S
Roller lever
• The angle from the free position to the maximum travel position is 70°
• Spring return
Type Ordering code
AL-SN11 PL2A-1 AL-SN11UL PL2A-1ZU
Adjustable length roller lever
• The lever length can be adjusted between 25mm and 76mm.
• Spring return
• The graduated scales on the lever facilitate adjustment
Type Ordering code
AL-SN21 PL2B-1 AL-SN21UL PL2B-1ZU
05
Adjustable length rod lever
• The ø3.2mm stainless steel rod can be extended up to 130mm max.
• Spring return
• The rod can be used by bending. (Radial 2mm min.)
KKD07-027
KKD07-043
Type Ordering code
AL-SK11 PL2P-1 AL-SK12 PL2P-2 AL-SK13 PL2P-3 AL-SK11UL PL2P-1ZU
Reversing top roller lever plunger
• This type is designed to detect the movements in the vertical direction.
Type Ordering code
AL-SK21 PL2Q-1 AL-SK22 PL2Q-2 AL-SK23 PL2Q-3 AL-SK21UL PL2Q-1ZU
Adjustable length rubber roller lever (ø40)
• The lever length can be adjusted between 30mm and 76mm
• Spring return
• The graduated scales on the lever facilitate adjustment
Type Ordering code AL-SN51 PL2C-1
Type Ordering code
AL-SN31 PL2C-1 AL-SN31UL PL2C-1ZU
KKD07-030
Wobble head coil spring rod
• The length of rod is 113mm from the head.
• Can be operated from any direction.
• Require little torque Type Ordering code
AL-SS11 PL2H-1 AL-SS11UL PL2H-1ZU
SI-1016
KKD07-031
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/9
Page 13
Limit Switches
AL and AL-S
Operating characteristics
Compact type (Snap action)
Type AL-SP11 AL-SP21 AL-SK11 AL-SK21 AL-SN11 AL-SN21 AL-SN31 AL-SN51 AL-SS11
Required operating force OF (max.) 4.5N 8.5N 4N 4N 7N 7N 7N 7N 1.5N Required resetting force RF (min.) 2N 4.5N 1.8N 1.8N 0.5N 0.5N 0.5N 0.5N — Preoperating travel PT (min.) 2mm 2mm 2.5mm 2.5mm 30° 30° 30° 30° 30mm Overtravel OT (min.) 4mm 3mm 5mm 5mm 40° 40° 40° 40° Movement differential (Travel to reset) 1mm 1mm 1.8mm 1.8mm 8°
MD (max.)
Notes: *1At lever or rod level length 25mm
2
*
At lever or rod level length 30mm
Compact type (Normal action, overlap action)
Type AL-SP12 Required operating force OF (max.) Movement to NC contact open Movement to NO contact closed Total travel TT (min., max.)
7N
1.5mm 3mm 6mm
AL-SP22
10.5N
1.5mm 3mm 6mm
1
*
AL-SK 2
6.3N 2mm 4mm 8mm
1
*
Overlap actionNormal action
AL-SP13
7N 3mm
1.5mm 6mm
AL-SP23
10.5N 3mm
1.5mm 6mm
2
*
AL-SK
6.3N 4mm 2mm 8mm
3
Description Standard/Compact UL approved
Type Ordering code Type Ordering code
With indicating lamp
AL-N1쏔쐽 PL1A-쏔쐽 AL-N11UL PL1A-1ZU AL-N2쏔쐽 PL1B-쏔쐽 AL-N21UL PL1B-1ZU AL-N3쏔쐽 PL1C-쏔쐽 AL-N31UL PL1C-1ZU AL-P1쏔쐽 PL1D-쏔쐽 AL-P11UL PL1D-1ZU AL-P2쏔쐽 PL1E-쏔쐽 AL-P21UL PL1E-1ZU AL-P3쏔쐽 PL1F-쏔쐽 AL-P31UL PL1F-1ZU AL-F1쏔쐽 PL1G-쏔쐽 AL-F11UL PL1G-1ZU AL-Y1쏔쐽 PL1L-쏔쐽 AL-Y11UL PL1L-1ZU AL-Y2쏔쐽 PL1M-쏔쐽 AL-Y21UL PL1M-1ZU AL-T3쏔쐽 PL1N-쏔쐽 AL-T31UL PL1N-1ZU AL-S1쏔쐽 PL1H-쏔쐽 AL-S11UL PL1H-1ZU AL-S2쏔쐽 PL1J-쏔쐽 AL-S21UL PL1J-1ZU
Standard type
• The indicating lamp can be fitted to all the AL limit switches.
• Neon lamp or LED, and stabilizing resistor are attached inside the housing so that the lamp lights or goes out when the switch is operating.
• The nylon cover makes the signal highly visible.
• Indicating lamps do not affect the switch
SI-314
dimensions or operating characteristics.
• The wiring connections for snap action type are shown below.
AL-W1쏔쐽 PL1K-쏔쐽 AL-W11UL PL1K-1ZU AL-SP1쏔쐽 PL2D-쏔쐽 AL-SP11UL PL2D-1ZU
AL-SP2쏔쐽 PL2E-쏔쐽 AL-SP11UL PL2E-1ZU AL-SK1쏔쐽 PL2P-쏔쐽 AL-SK11UL PL2P-1ZU AL-SK2쏔쐽 PL2Q-쏔쐽 AL-SK21UL PL2Q-1ZU AL-SN1쏔쐽 PL2A-쏔쐽 AL-SN11UL PL2A-1ZU AL-SN2쏔쐽 PL2B-쏔쐽 AL-SN21UL PL2B-1ZU AL-SN3쏔쐽 PL2C-쏔쐽 AL-SN31UL PL2C-1ZU AL-SS1쏔쐽 PL2H-쏔쐽 AL-SS11UL PL2H-1ZU
Replace the mark by the contact action code Replace the mark by the lamp voltage code
Compact type
KKD07-028
NO
34 12
NC
L
Power supply
The lamp lights when NO contact closes
Load
L
NO
34
12
NC
Power supply
The lamp lights when NO contact opens
Load
05/10
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 14
Limit Switches
AL and AL-S
Accessories
Description Operating Type Ordering code
Standard type sealed Cable dia. ø7.5 – ø11.5 (for AL type) ALX-016 PL1XW-A conduit (øD) ø7 – ø11 (for AL-S type) ALX-510 PL1XW-B
22
ø
12
(Plastic)
Complete type sealed Cable dia. ø6 – ø9 ALX-013 PL1XW-C
24
conduit (øD) ø8 – ø11 ALX-014 PL1XW-D (Metal)
SI-233
Lamp cover for AL series For snap action LED lamp 6V DC ALX-011A PL1XL-1A
SI-232
Lamp cover for AL-S series For snap action LED lamp 6V DC ALX-507A PL2XL-1A
SI-350
Cable
15
Packing
Min. 15 14 9
Washer
Nut
Packing O ring Condiut
68
40
6.5
50
30
Limit switch
D
ø
G1/2
5
(42.5)
9.2 (35.7)
(PF1/2)
ø12 – ø14 ALX-015 PL1XW-E
G-16
[PF-1/2]
(for AL type, AL-S type, AL1-S type)
LED lamp 12V DC ALX-011B PL2XL-1B LED lamp 24V DC ALX-011E PL1XL-1C Neon lamp 110/220V AC ALX-011H PL1XL-1D
For normal action LED lamp 6V DC ALX-012A PL1XL-2A
LED lamp 12V DC ALX-012B PL1XL-2B LED lamp 24V DC ALX-012E PL1XL-2C Neon lamp 110/220V AC ALX-012H PL1XL-2D
LED lamp 12V DC ALX-507B PL2XL-1B LED lamp 24V DC ALX-507E PL2XL-1C Neon lamp 110/220V AC ALX-507H PL2XL-1D
For normal action LED lamp 6V DC ALX-508A PL2XL-2A
LED lamp 12V DC ALX-508B PL2XL-2B LED lamp 24V DC ALX-508E PL2XL-2C Neon lamp 110/220V AC ALX-508H PL2XL-2D
05
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/11
Page 15
Limit Switches
16
6.5
8.5
ø3.2
160
AL and AL-S
Actuators For AL series
Description Type
Roller lever ALX-001
ø
17.5
38
18
6
7
11.4
Stainless steel roller
For AL-S series
Description Type
Roller lever ALX-501
ø
17.5
25
SI-316SI-177
5
6.3
6
Stainless steel roller
Adjustable length roller lever ALX-003
ø
SI-173
17.5
97.3
20.5
15.7
7
Adjustable length rod lever ALX-005
ø
3.2
141
SI-171
6.4
11.4
Fork roller lever ALX-007
ø
17.5
77
Stainless steel roller
Stainless steel rod
Stainless steel roller
Adjustable length roller lever ALX-503
5
12
KKD07-033
ø
17.5
86.5
16
Adjustable length rod lever ALX-505
KKD07-034
Stainless steel roller
Stainless steel rod
38
SI-175
Fork roller lever ALX-009
ø
38
SI-176
05/12
17.5
38
11.4
77
Stainless steel roller
38
11.4
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 16
Dimensions, mm (AL series)
Roller lever AL-N1
ø17.5
R38
14.7
58.5 53
7
13.1
Adjustable length roller lever AL-N2
65.5
ø17.5
25 - 90
14.7
60
7
13.1
Limit Switches
AL and AL-S
Adjustable length rod lever AL-N3
6.4
ø3.2
141
14.7
53.1
13.1
46
58.7
5
30.2 40
4-ø5.2
G1/2 (PF1/2)
Mass: 265g
Top push rod plunger AL-P1
ø10
PT : 2 max
3458.75
4-ø5.2
30.2 40
Mass: 165g
G1/2 (PF1/2)
Fork roller lever AL-F1
ø17.5
R38
14.7
21.6
15.5 4-M6
29.2 41
Stainless steel roller
13.1
21.6
15.5
4 - M6
29.2
41
Stainless steel plunger
58.5 53
40
7
13.1
58.7
5
Mass: 305g
30.2 40
4-ø5.2
G1/2 (PF1/2)
21.6
15.5
29.2 41
Stainless
4-M6
58.7
5
Mass: 260g
steel roller
Top push roller plunger AL-P2
ø17
PT : 2 max4458.75
4-ø5.2
30.2 40
Mass: 200g Mass: 200g
G1/2 (PF1/2)
13.1
4.8
21.6
15.5
29.2
41
Stainless
4 - M6
Top ball push rod plunger AL-P3
PT : 2 max
44.4
58.7
5
steel roller
Side push rod plunger AL-Y1
PT : 2.8 max
17.8
ø10
53.7
13.1
Side push roller plunger AL-Y2
30.2
ø15.5
30.2 40
4.8
40
4-ø5.2
G1/2 (PF1/2)
4-ø5.2
G1/2 (PF1/2)
PT : 2.8 max
ø17
Stainless steel rod
Stainless steel ball
67.3
13.1
29.2
41
15.5
29.2
41
13.1
21.6
15.5
21.6
4-M6
05
4-M6
58.7
5
30.2 40
4-ø5.2
G1/2 (PF1/2)
Mass: 310g Mass: 285g
21.6
15.5
29.2
41
Stainless
4-M6
58.7
5
Mass: 275g
30.2 40
4-ø5.2
G1/2 (PF1/2)
steel roller
21.6
15.5
4-M6
29.2
41
Stainless steel plunger
58.7 17.8
5
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
30.2 40
4-ø5.2
G1/2 (PF1/2)
21.6
15.5 4-M6
29.2
41
Stainless steel roller
05/13
Page 17
Limit Switches
AL and AL-S
Dimensions, mm (AL series)
Side ball push rod plunger AL-Y3
PT : 2.8 max
67.2
13.1
Wobble head coil spring rod AL-S1
140
Wobble plastic head spring rod AL-S2
ø7
13.1
Polyamide resin
61.5
140
ø7
13.1
58.7 17.8
5
30.2 40
4-ø5.2
G1/2 (PF1/2)
Mass: 285g Mass: 220g
21.6
15.5
4-M6
29.2
41
Stainless steel ball
58.7
5
Wobble head with cat’s whisker AL-W1
ø1.4
58.7 190
5
115
30.2 40
G1/2 (PF1/2)
4-ø5.2
21.6
15.5
29.2 41
13.1
4-M6
30.2 40
4-ø5.2
G1/2 (PF1/2)
21.6
15.5 4-M6
29.2 41
Stainless steel coil spring
58.7
5
Mass: 210g
30.2 40
G1/2 (PF1/2)
4-ø5.2
21.6 4-M6
15.5
29.2
41
Stainless steel coil spring
Mass: 210g
05/14
Stainless steel coil spring
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 18
Dimensions, mm (AL-S series/Compact size)
Top push rod plunger AL-SP1
Top push roller plunger AL-SP2
Limit Switches
AL and AL-S
Top roller lever plunger AL-SK1
22
20
PT : 2 max18
55
ø6
4.3
30
15
30
Polyamide resin plunger
Reversing top roller lever plunger AL-SK2
PT : 2.5 max
26.8
11
55
13
ø
R18
20
10
20
64
G1/2 (PF1/2)
5
10
PT : 2 max
2855
Mass: 60gMass: 55g
Roller lever AL-SN1
2055
ø10
30
ø17.5
R25
5
10
30
Stainless steel roller
47
42
5
10
64
PT : 2.5 max35.855
R18
Mass: 65g
ø13
11
20
30
5
10
30
Stainless steel roller
Adjustable length roller lever AL-SN2
05
5
50
45.3
43
10
ø17.5
2055 25~76
84
30
Mass: 65g
Adjustable length rod lever AL-SN3
6.5
160
20
55
30
Mass: 105g
30
Stainless steel roller
51
42.4
ø3.2
30
Stainless steel rod
30
Mass: 100g
30
30
Stainless steel
Mass: 120g
roller
Wobble plastic head spring rod AL-SS1
Polyamide
ø4.2
resin
ø5.3
37
10
11355
Mass: 80g
30
Stainless steel
10
30
Adjustable length rubber roller lever AL-SN51
Rubber roller
ø 40
30to7620
Mass: 130g
30
Stainless steel roller
10
56
43
Rubber roller
coil spring
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/15
Page 19
Limit Switches
K244 General information
Momentary-contact limit switches K244 series
Description
FUJI K244 type limit switches have an excellent performance. K244 limit switches employ a highly dependable and long lasting double break silver alloy contact system. These can be expected to perform more than 10 million mechanical operations and a rate of 3,000 operations per hour. The large variety of operating types such as standard stroke, snap-action type, make-before-break type and extended stroke type, etc. allow you to select a suitable limit switch that fully meets your requirements. K244 limit switches are widely used for industrial machinery such as machine tools, printing machines, conveyors, automatic machines and door interlocking and similar applications. The aluminum die-cast housing can also be supplied in an oil and water proof version.
Technical data
Insulation resistance:
Over 100M at 500V DC
Dielectric strength:
2500V AC rms 1 minute
Max. operating cycle:
3000 cycles per hour
Life expentancy
Mechanical: 10 million operations Electrical: K244-2, 2U and 2V
3.3 million operations at 24 to 550V AC 3A K244-2S
1.3 million operations at 24 to 550V AC 3A
Ordering information
Specify the following:
1.Type number or ordering code
Example
Limit switch ................................ PL
With enclosure................................5
Standard contact ..............................N
Cast-metal clad enclosure .................. G
With top roller lever plunger ................... R
Contact, normal action 1NO+1NC ........... 22
Ordering code............................ PL5NGR22
T-1544
K244xP-2 K244gR-2 K244g-2 K244gR-2/2
Ratings
Type Thermal Making Breaking current *
current current AC DC
Voltage Current Voltage Current (A)
(A) (A) (V) (A) (V) Resistive Inductive
K244-2 10 50 24 10 24 10 10 K244-2U 110 10 110 2.2 1.3 K244-2V 220 10 220 0.9 0.4
440 10 440 0.4 0.2 550 10 550 0.32*2 0.15*
K244-2S 10 50 24 10 24 7 7
110 10 110 1.5 0.9 220 10 220 0.63 0.28 440 10 440 0.28 0.14 550 10 550 0.22*
Notes: *1When NO and NC contacts are wired in the same potential.
*2Value of the breaking current when opposite contacts are not applied with potential.
1
2
0.1*
Type number nomenclature

K244쏔쏔 - 2

Basic type Enclosure
xP: With transparent cover g: Cast-metal clad go: Cast-metal clad oil-tight gw: Cast-metal clad water-tight
Actuator
Blank: Top push rod plunger R: Top roller lever plunger
Contact type
Blank: Standard contact
(Normal stroke) S: Snap action contact U: Make-before-break contact V: Extended stroke
Contact arrangement
2: 1NO+1NC 2/2: 2NO+2NC
Ordering code
PL 5 N G N – 22
Product category
PL: Limit switch
Enclosure
4: Without enclosure 5: With enclosure
Contact
N: Standard W:Bifurcated H: Scrubbing action
Enclosure type
G: Cast-metal clad L: Cast-metal clad oil-tight W:Cast-metal clad water-tight
Contact arrangement
22: 1NO+1NC, normal action 21: 1NO+1NC, snap action 23: 1NO+1NC, make-before-break 25: 1NO+1NC, extended stroke 42: 2NO+2NC, normal action 41: 2NO+2NC, snap action 43: 2NO+2NC, make-before-break 45: 2NO+2NC, extended stroke 46: 2NO+2NC, complex
Roller head position
N: Top push rod plunger R: Top roller lever plunger W:Reversing, right-hand side roller
SB-401
2
2
05/16
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 20
Limit Switches
K244
Actuating slider face angles and
approach speeds
Although K244 limit switches have an excellent performance they should not be operated at an extremely high speed or extremely low speeds, since these conditions will cause contact trouble and reduce the mechanical life expectancy of the devices. The slider face angles and approach speeds should be kept within the following recommendations.
Push rod plunger type
This type of switch obtains the movement from the vertical travel of the rod. Speed : Max. 1m/sec
Min. 0.015m/sec Snap-action types can be used at speeds less than the minimum value.
Roller lever type
The actuating slider face angles and speeds should be within the following range. The maximum angle of the slider face:
α
1=45°α2=30°
Snap-action type switches can be used at speeds less than the minimum value.
Travel operating force curve
(Typical example)
The curve indicates forces to operate the contact.
Standard type K244g-2
NC contacts open
0
K244gR-2
NC contacts open
Overtravel
NO contacts close
3.51.5 Travel
Overtravel
NO contacts close
10N
5N
64321
5
6.5mm
0
Operating force
10N
5N
Changing direction of operating
roller head
Roller head positions can be shifted by 90° in each direction. The head is attached at the standard position when shipped from factory.
Standard type
f type
05
2
(m/sec)
4 3
2
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Speed of slider
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
2V type,
2
upper limit
2V type,
2
lower limit
0 5 10 15 20 25 30
2 1
2, 2U, 2S, 2V type,
1
lower limit
Slider angle
Slider
2, 2U, 2S, 2V type,
1
upper limit
2, 2U, 2S type,
2
upper limit
2, 2U, 2S type,
2
lower limit
Max. value of
2
35
1
40 45
Max. value of
0
Snap action contact type K244g-2S
Margin
Snap operating point
1
0
K244gR-2S
Snap operating point
End play
1
0
7
64321
5
4.21.7
6.2
0
7.4mm
Travel
Overtravel
26N
20N
15N
10N
0.6kg 32
1.4
5N 0
4mm
Travel
Overtravel
21N
15N
10N
5N
6
5
4
3
21 7.4mm
4.3
2.5
7
0
Travel
Operating force
Cable connection
Threaded conduit entrances are provided at 3 locations–left, right and lower side of the limit switch housing. Knockout the plug to carry out wiring. Do not remove plugs from holes not requiring wiring.
Operating force
Threaded conduit entrance
SDO-0115M.
K244gR-2
Operating force
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/17
Page 21
Limit Switches
K244 Standard type
K244 series/Standard
Description Contact Ter- Travel Type Ordering Dimensions, mm
arrangement minal Contact closed code
No. Contact open
Top push rod plunger with 1NO+1NC transparent plastic cover
4
Normal stroke K244xp-2 PL4NN-22
Snap-action K244xp-2S PL4NN-21
2
3
1
4
2 13
4
2
Make-before-break K244xp-2U PL4NN-23
3
1
4
SF2025
Extended stroke K244xp-2V PL4NN-25
2
3
1
S (mm)
1.5
1–2 3–4
023.56.3
1.4
3–4 1–2
024
3
1–2 3–4
02 6
Momentary open
1–2 3–4
068.5
10
6
M4 Terminal
Lead hole
29
-2 -2S -2U -2V
A 21192121 B 1.5 1.5 1.5 1.0 C 6.5 1.4 6 8.5
Mass: 60g
Top push rod plunger 1NO+1NC S (mm) cast-metal clad
T-1535
4
Normal stroke K244g-2 PL5NGN-22
Snap-action K244g-2S PL5NGN-21
2
3
1
4
2
13
4
2
Make-before-break K244g-2U PL5NGN-23
3
1
4
2
Extended stroke K244g-2V PL5NGN-25
3
1
1.5
1–2 3–4
023.56
1.4
3–4 1–2
04
1–2 3–4
1–2 3–4
3
02 5
Momentary open
068.4
16
5.5
22
2
16
42
Earth terminal
-2 -2S -2U -2V A 26242626 Mass: 200g
Top push rod plunger oiltight 1NO+1NC S (mm) and watertight cast-metal clad
Snap-action Oiltight
T-1535
4
2 13
3–4 1–2
1.4
0 2.4
K244go-2S PL5NLN-21
Watertight K244gw-2S PL5NWN-21
17
6
22
2
Conduit
16
entrance
45 Earth
terminal
Mass: 210g
22
ø5
ø4.3
4
56
42 77
38
33
Brass plunger
ø5
16
ø4.5
40
75
4.5
CTC19
44
Mounting hole
4
56
Conduit entrance
Brass plunger
ø5
16
75
ø4.5
40
Mounting hole
4
5655
Brass plunger
S
ABC
S
A
S
26
Contact action (Typical)
Contact Standard type Snap action Make-before- Extended stroke
Contact diagram
Contact travel
: Contact closed : Contact open
(Normal stroke) contact break contact
24
13
1.5
1-2 3-4
0 2 4 6 6.3
(mm)
24
13
1.4
3-4 1-2
024
(mm)
24
13
(mm)
3
1-2 3-4
0246
24
13
Momentary open (mm)
1-2 3-4
024688.5
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
05/18
Information subject to change without notice
Page 22
K244 series/Standard
16115
145
AS
ø5
16
5.5
44
4
44
60
45
16
25
1
3-ø4.5 Mounting holes
Conduit entrance
Earth terminal
Limit Switches
K244
Standard type
Description Contact Ter- Travel Type Ordering Dimensions, mm
arrangement minal Contact closed code
No. Contact open
Top roller lever plunger 1NO+1NC cast-metal clad
4
Normal stroke K244gR-2 PL5NGR-22
Snap-action K244gR-2S PL5NGR-21
Make-before-break K244gR-2U PL5NGR-23
T-1537
Extended stroke K244gR-2V PL5NGR-25
2
3
1
4
2
13
4
2
3
1
4
2
3
1
S (mm)
1.7
1–2 3–4
0 4.2 7.5
3–4 1–2
1–2 3–4
1–2 3–4
4.3
0
3.6
2.4
0
0.5
0 7.5
7.5
7.5
16
10
5.5
22
Earth
16431
terminal
Conduit entrance
S
R26.9 ø22
A
16
75
4
Roller
26
19
2-ø4.5
40
Mounting holes
4
4
56
Phenal-formaldehyde roller
-2 -2S -2U -2V
A 55555557
10
Mass: 240g
Top roller lever plunger oiltight 1NO+1NC S (mm) and watertight cast-metal clad
Snap-action Oiltight
T-1531
4
2 13
3–4 1–2
6.2
0
7.5
K244goR-2S PL5NLR-21
Watertight K244gwR-2SPL5NWR-21
17
10
6
22
2
Earth
16
terminal
45
Conduit entrance
58.5
S
19
16
40
75
4
5
56
R26.9
ø22 Roller
5
05
29
Phenal-formaldehyde roller
Mass: 250g
Top push rod plunger 2NO+2NC S (mm) cast-metal clad
432
432
432
432
4 3
1
4 3
1
4 3
1
4 3
1
Normal stroke K244g-2/2 PL5NGN-42
2 1
Snap-action
2 1
Make-before-break
2 1
Extended stroke
2 1
➀➁
T-1567
Complex Normal stroke +
(
Make-before-break
2 1
)
➀➁
Top push rod plunger oiltight 2NO+2NC S (mm) and watertight cast-metal clad
Snap-action Oiltight
T-1567
2 1
432
432
4 3
1
4 3
1
1.5
1–2 3–4
0 3.5 6
1.4
3–4 1–2
0
1–2 3–4
0
0.5
1–2
3–4 1–2
3–4
0 8.4 0
1–2
3–4 1–2
3–4
1.5
3–4 1–2
0
1.4
4
3
K244g-2U/2U
K244g-2S/2S
2
5
6.5
K244g-2V/2V
6
5
32
K244g-2/2U PL5NGN-46
3.5
2.4
K244go-2S/2S
Watertight
K244gw-2S/2S
PL5NGN-41
PL5NGN-43
PL5NGN-45
PL5NLN-41
PL5NWN-41
Brass plunger
2/2 2S/2S 2U/2U 2V/2V 2/2U A2624262626 Mass: 410g
17
6
6
25
2
16
47
Mass: 420g
Conduit entrance
Brass plunger
ø5
S
16115
145
5
26
44
3-ø4.5 Mounting holes
Earth
4
terminal
5
60
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/19
Page 23
Limit Switches
K244 Standard type
K244 series/Standard
Description Contact Ter- Travel Type Ordering Dimensions, mm
arrangement minal Contact closed code
No. Contact open
Top roller lever plunger 2NO+2NC cast-metal clad
Normal stroke K244gR-2/2 PL5NGR-42
Snap-action
Make-before-break
Extended stroke
2
2
4
1
3
1
2
432
1
1
2
432
1
1
2
432
1
1
➀➁
T-1567
Complex Normal stroke + Make-before-break
2
432
)(
1
1
➀➁
4
3
4
3
4
3
4
3
4
3
S (mm)
1–2 3–4
0 4.2 7.5
3-4 1-2
0
1–2 3–4
0 0
1
1–2
3–4 1–2
3–4
0.5 7.5 0
1–2
3–4 1–2
3–4
1.7
1.7
2.4
2.4
3.6
3.6
4.3
4.2
K244gR-2S/2S
7.5
K244gR-2U/2U
7.5
8.2
K244gR-2V/2V
10
K244gR-2/2U
7.5
PL5NGR-41
PL5NGR-43
PL5NGR-45
PL5NGR-46
16
10
5.5
25
1
16
45
Phenal-formaldehyde roller
2/2 2S/2S 2U/2U 2V/2V 2/2U A5555555755 Mass: 440g
Top roller lever plunger oiltight 2NO+2NC S (mm) and watertight cast-metal clad
Snap-action Oiltight
2
4
4
2 1
1
3
3–4 1–2
3
0
6.2
7.5
K244goR-2S/2S
Watertight
K244gwR-2S/2S
PL5NLR-41
PL5NWR-41
17
10
6
A
Conduit entrance
58.5
145
145
16
115
16
115
S
R26.9
ø22 Roller
26
19
44
3-ø4.5 Mounting holes
Earth
4
4
terminal
4
60
S
R26.9
ø22 Roller
29
19
44
3-ø4.5 Mounting holes
T-1567
25
2
18
47
Conduit entrance
Phenal-formaldehyde roller
Mass: 450g
4
Earth
5
5
terminal
60
05/20
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 24
Reversing roller lever momentary­contact limit switches, K244g첸R
Description
These limit switches are designed to detect the movements in the vertical direction. The switch body is identical to the standard type except that one roller is extended from the housing. The performance is the same as for the standard type.
Standard Reversing
Ratings
Type Thermal Making Breaking current *
Right side roller
Actuating slider face angles and
approach speeds
K244 limit switches have an outstanding performance and will have a long service life under normal conditions. They are designed to carry out 3,000 operations per hour but if they are operated at an extremely high speeds or on the contrary at extremely low speeds contact trouble could develop which would reduce the mechanical life expectancy of the devices. Reversing roller levers are provided with sliders in their vertical direction. The slider face angles and approach speeds should be kept within the range shown by curves. The maximum angle of the actuating slider is α1=45°, α2=30° and under. Snap-action types can be used at speeds less than the minimum value given.
[m/sec]
4 3
2
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
2V type, 2 upper limit
0.2
Slider speed
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
2, 2U, 2S type, 2 lower limit
0.02
2V type, 2 lower limit
0.01 0
5
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
2, 2U, 2S, 2V type, 1 upper limit
2, 2U, 2S, 2V type, 1 lower limit
15 20
10
Slider angle
2, 2U, 2S type, 2 upper limit
Max. value of 2
30
35
25
2
Slider
2
1
1
Max. value of 1
45
40
K244gRA-2 10 50 24 10 24 10 10 K244gRA-2U 110 10 110 2.2 1.3 K244gRA-2V 220 10 220 0.9 0.4
K244gRA-2S 10 50 24 10 24 7 7
Notes: *1When NO and NC contacts are wired in the same polarity.
*2Opposite contacts are not permitted to carry potential.
Ordering information
Specify the following
1.Type number or ordering code
Example
Limit switch ...............................PL
With enclosure.............................. 5
Standard contact ............................ N
Cast-metal clad enclosure .................G
With reversing roller plunger ................. W
Contact 1NO+1NC, snap-action ............. -21
Ordering code.......................... PL5NGW-21
Ordering code:
Travel operating force:
See page 05/17.
Cable connection:
Type number nomenclature
Basic type Enclosure
g: Cast-metal clad go: Cast-metal clad oil-tight gw: Cast-metal clad water-tight
Actuator
R: Top roller lever plunger A: Reversing roller
Technical data: Same as standard type,
Limit Switches
K244 reversing roller type
S-2900 SF-2028
K244gRA-2 K244gRA-2/2
1
current current AC DC (A) (A) (V) (A) (V) Resistive Inductive
See page 05/16.
See page 05/17.
Voltage Current Voltage Current (A)
440 10 440 0.4 0.2 550 10 550 0.32 0.15*
110 10 110 1.5 0.9 220 10 220 0.63 0.28 440 10 440 0.28 0.14 550 10 550 0.22 0.1*
Changing direction of operating
head
Right side roller Left side roller
Front-side roller
K244쏔쏔쏔 - 2
Contact type
Blank: Standard contact
(Normal stroke) S: Snap-action contact U: Make-before-break contact V: Extended stroke contact
Contact arrangement
2: 1NO+1NC 2/2: 2NO+2NC
see page 05/16.
2
2
05/21
05
Page 25
Limit Switches
16
10
5.5
22
116
43
A
S
57.6
16
75
19
40
4456
4
26
3-ø4.5 Mounting holes
Conduit entrance
Earth terminal
R21.6
ø22 roller
K244 reversing roller type
K244 series/Reversing roller
Description Contact Ter- Travel Type Ordering Dimensions, mm
arrangement minal Contact closed code
No. Contact open
Reversing top roller lever 1NO+1NC plunger cast-metal clad
Normal stroke K244gRA-2 PL5NGW-22
Snap-action K244gRA-2SPL5NGW-21
Make-before-break K244gRA-2UPL5NGW-23
S-2900
Extended stroke K244gRA-2VPL5NGW-25
4
2
3
1
4
2
13
4
2
3
1
4
2
3
1
S (mm)
1.8
1–2 3–4
0 2 3.8 6.6
3-4 1-2
1–2 3–4
1–2 3–4
3.6
0
3
02 6
Momentary open
0 5.7 8.3
6.2
A 43.6 43.6 43.6 45.8 Mass: 240g
Reversing top roller lever 1NO+1NC S (mm) plunger oiltight and watertight cast-metal clad
4
Snap-action Oiltight
2
3
1
3–4 1–2
4.6
0 6.6
K244goRA-2S
PL5NLW-21
Watertight
K244gwRA-2S
S-2900
PL5NWW-21
Mass: 250g
Reversing top roller lever 2NO+2NC S (mm) plunger cast-metal clad
Normal stroke
Snap-action
Make-before-break
Extended stroke
SF-2028
Complex Normal stroke +
(
Make-before-break
2 1
2 1
2 1
2 1
2 1
)
➀➁
4 3
4 3
432
4 3
432
4
2
3
1
4
2
3
1
4 3
1
4
2
3
1
4 3
1
1.8
1–2 3–4
0 2 3.8 6.6
3.6
3-4 1-2
0
3
1–2 3–4
02 6
Momentary open
1–2 3–4
0 5.7 8.3
3
0
2
1–2 3–4 1–2 3–4
1.8
3.8
K244gRA-2/2
K244gRA-2S/2S
6.2
K244gRA-2U/2U
K244gRA-2V/2V
6
K244gRA-2/2U
7.5
PL5NGW-42
PL5NGW-41
PL5NGW-43
PL5NGW-45
PL5NGW-46
A 43.6 43.6 43.6 45.8 43.6 Mass: 440g
Reversing top roller lever 2NO+2NC S (mm) plunger oiltight and watertight cast-metal clad
432
4 3
1
3–4 1–2
Snap-action Oiltight
1
2
4.6
0 6.6
K244goRA PL5NLW-41
-2S/2S
Watertight
K244gwRA PL5NWW-41
-2S/2S
Mass: 450g
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/22
SF-2028
-2 -2S -2U -2V
Phenal-formaldehyde roller
17
10
60.6
16
6
22
2
16
45
Conduit entrance
75
43.6
19
40
4
5
56
Phenal-formaldehyde roller
16
10
57.6
5.5
25
1
16
45
Conduit entrance
145
19
44
115 16
4
4
60 4
Phenal-formaldehyde roller
2/2 2S/2S 2U/2U 2V/2V 2/2U
145
43.6
19
44
115 16
4
5
60
17
10
60.6
6
25
2
16
47
Conduit entrance
Phenal-formaldehyde roller
5
A
3-ø4.5 Mounting holes
3-ø4.5 Mounting holes
5
ø22 roller
R21.6
29
3-ø4.5 Mounting holes
Earth terminal
ø22 roller
S
R21.6
26
Earth terminal
ø22 roller
S
R21.6
26
Earth terminal
S
Page 26
Momentary-contact limit switches for low voltage circuit HK244 and WK244
Description
HK244 and WK244 limit switches have been developed for use in low voltage and low current circuits. They will operate effectively in 3 Volts AC or DC, 5mA circuits although they are recommended that they are used in 48 Volts or 110 Volts circuits for best results.
HK244 limit switches
HK244 limit switches are provided with pure silver contacts. The movable contact carries out a scrubbing action during make/break operation ensuring good connections at all times. The switch body is molded from a high performance resin, and versions with transparent plastic covers and with aluminum die-cast housing are also available.
WK244 limit switches
The bifurcated contact is made of pure silver and like the HK244 series they are also suitable for use with low voltage circuits. The dimensions and operating strokes are similar to the standard type.
Ordering information
Specify the following:
1.Type number or ordering code
Example
Limit switch ................................ PL
With enclosure................................ 5
Scrubbing contact ............................. H
Cast-metal clad enclosure .................. G
Top roller lever plunger .......................... R
Contact 1NO+1NC, normal stroke .......... -22
Ordering code........................... PL5HGR-22
Dimensions, mm
Same as standard type limit switch K244 series.
05/22.
Ordering code:
See page 05/18 to 05/20,
See page 05/16.
Limit Switches

HK244 and WK244

SK-583 T-1537 T-1535
WK244xp-2 HK244gR-2 HK244g-2
Ratings
HK244
Thermal Making Breaking current * current current AC DC
(A) (A) (V) (A) (V) Resistive Inductive 10 50 24 10 24 7 7
WK244
Thermal Making Breaking current * current current AC DC
(A) (A) (V) (A) (V) Resistive Inductive 10 12.5 110 2.5 110 1.5 0.2
Notes: *1When NO and NC contacts are wired in same polarity.
*2Opposite contacts are not permitted to carry potential.
Voltage Current Voltage Current (A)
110 10 110 1.5 0.9 220 10 220 0.63 0.28 440 10 440 0.28 0.14 550 10 550 0.22*
Voltage Current Voltage Current (A)
220 2.5 220 0.63
Contacts
HK244 WK244
Plunger
Contact spring
Stationary contact
Moving contact
Contact scrubbing
Stationary contact
Process of scrubbing contact Bifurcated contact
begins
Technical data
HK244
Insulation resistance: Over 100M at 500VDC Dielectric strength: 2500V AC rms 1 minute Max. operating cycle: 3000 cycles per hour Life expectancy Mechanical: 10 million operations
Electrical: 1.3 million operations at 24 to 550V AC 3A
Allowable ambient temperature: –5° to +60°C
1
1
Contact scrubbing completed
2
0.1*
2
Sliding frame
05
WK244
Insulation resistance: Over 100M at 500VDC Dielectric strength: 2500VAC rms 1 minute Max. operating cycle: 3000 cycles per hour Life expectancy Mechanical:10 million operations
Allowable ambient temperature: –5° to +60°C
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Electrical: 1 million operations at 220V AC 1.5A
05/23
Page 27
Limit Switches
HK244 and WK244
HK244 and WK244 series
Description Contact Travel (mm) of HK HK series WK series Dimensions
Top push rod plunger 1NO+1NC transparent plastic cover
Normal stroke HK244xp-2 PL4HGN-22 WK244xp-2 PL4WGN-22
Make-before-break HK244xp-2U PL4HGN-23 WK244xp-2U PL4WGN-23
Top push rod plunger 1NO+1NC cast-metal clad
Normal stroke HK244g-2 PL5HGN-22 WK244g-2 PL5WGN-22
Make-before-break HK244g-2U PL5HGN-23 WK244g-2U PL5WGN-23
Top roller lever plunger 1NO+1NC cast-metal clad
Normal stroke HK244gR-2 PL5HGR-22 WK244gR-2 PL5WGR-22
Make-before-break HK244gR-2U PL5HGR-23 WK244gR-2U PL5WGR-23
Reversing top roller lever 1NO+1NC plunger cast-metal clad
Normal stroke HK244gRA-2 PL5HGW-22 WK244gRA-2 PL5WGW-22
Make-before-break HK244gRA-2U PL5HGW-23 WK244gRA-2U PL5WGW-23
Top push rod plunger 2NO+2NC cast-metal clad
Normal stroke HK244g-2/2 PL5HGN-41 WK244g-2/2 PL5WGN-41
Make-before-break HK244g-2U/2U PL5HGN-43 WK244g-2U/2U PL5WGN-43
Complex HK244g-2/2U PL5HGN-46 WK244g-2/2U PL5WGN-46 Normal stroke +
(
Make-before-break
Top roller lever plunger 2NO+2NC cast-metal clad
Normal stroke HK244gR-2/2 PL5HGR-41 WK244gR-2/2 PL5WGR-41
Make-before-break HK244gR-2U/2U PL5HGR-43 WK244gR-2U/2U PL5WGR-43
Complex HK244gR-2/2U PL5HGR-46 WK244gR-2/2U PL5WGR-46 Normal stroke +
(
Make-before-break
Reversing top roller lever 2NO+2NC plunger cast-metal clad
Normal stroke HK244gRA-2/2 PL5HGW-41 WK244gRA-2/2 PL5WGW-41
Make-before-break
Complex HK244gRA-2/2U PL5HGW-46 WK244gRA-2/2U PL5WGW-46 Normal stroke +
(
Make-before-break
Contact closed Contact open
arrange- series With scrubbing With bifurcated (Same as ment (WK series: Same as contact action contact K244)
standard series, pages Type Ordering Type Ordering 05/115 to 05/117) code code
4
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
2
2
4
1
3
3
1 2
1 2
1
)
2
13 2
1 2
1
)
24
13 2
1 214
)
4
2
4
1
3
3 4
4
2
3
3
1
4
2
4
1
3
4
2
4
3
1
3 4
4
2
3
1
3
2
4
3
1
4
2
4
3
3
1
4
2
3
1
3
2
1–2 3–4
0 3 6.5
1–2 3–4
1–2 3–4
1–2 3–4
1–2 3–4
1–2 3–4
1–2 3–4
1–2 3–4
1–2 3–4
1–2 3–4
3.5
0 1.5 6
2 1–2 3–4
0
3
3.5 1–2 3–4
0 1.5 4
2.2
0 3.7 7.5
4.1
0 1.9 7.5
2.2
0 3.2 6.2
3.8
0 1.8 6.2
2 1–2 3–4
036
1–2 3–4
1–2 3–4 1–2 3–4
1–2 3–4
1–2 3–4
1–2 3–4 1–2 3–4
3.5
1.5
0
0
2
3
1.5 5
3.5
0
2.2
0 3.7 7.5
4.1
0 1.9 7.5
3.7
2.2
0
4.1
0 1.9 7.5
2.2
0 3.2 6.2
3.8
0 1.8 6.2
0
2.203.2
3.8
1.8
Page 05/18
Page 05/18
6
Page 05/18
Page 05/18
Page 05/19
Page 05/19
Page 05/22
Page 05/22
Page 05/19
5
5
Page 05/19
Page 05/19
Page 05/20
Page 05/20
7.5
Page 05/20
Page 05/22
HK244gRA-2U/2U
6.2
➀ ➁
6.2
PL5HGW-43
WK244gRA-2U/2U
PL5WGW-43
Page 05/22
Page 05/22
05/24
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 28

Proximity Switches

General information

SP-387 KK02-298A
PE-L PE1-C, PE2-C PE1-Y
SM-81 AF91-508AF89-744 SK586
PE-U PE-X3D
Proximity switches, PE series
Description
These proximity switches have many advantages over conventional limit switches, enabling their use where other switches will not do. FUJI offers two types – inductive and magnetic. Sensors
PE-T
PE-B7
Features PE-U series
(See page 05/28)
• Operating distance: 7mm and 10mm
• Operating voltage range: 10 to 30V DC
• Suitable for detecting of ferromagnetic materials
and switching components are completely enclosed for protection against oil mist, metal fillng, dust, and moisture. Inductive types use a solid-state switching device; magnetic types use a reed switch.
PE1-C and PE1-Y series
(See page 05/29)
• Short length achieved with IC
• 6 shielded and 4 non-shielded types
• AC 2-wire, DC 2-wire, and DC 3-wire systems
• Stable operating indicator provided as standard (mounting diameter M12 or
PE series proximity switches
more, and NO contact type).
Inductive type
Inductive proximity switches are available in AC or DC versions. The PE-U series is slot type. The PE1-C and PE1-Y series are cylindrical. The detecting surface of PE-B series is square. The PE-T series switches are slim types. The PE1B2P is
PE-B series
(See page 05/33)
• 4mm to 50mm operating distance
• Types with operating distance exceeding 20mm conform to the CENELEC Standard.
• Operating voltage range: 80 to 250V AC or 10 to 30V DC
AF89-193
PE-L series
• Output voltage proportional to distance
• Linearity: ±1.5% of full scale Resolution: ±0.05% of full scale
• Operating frequency: Up to 10kHz
• Operating distance: 2 to 10mm
PE2-C series
• 4 shielded and 3 non-shielded types
• Stable operating level indicating lamp facilitates adjustment
• DC 2-wire, DC 3-wire and AC/DC 2-wire operating systems
• 40 to 250V AC/20 to 250V DC (AC/DC 2-wire system)
PE-X3D series
• Only 7mm thick
• Operating voltage range: 10 to 30V DC
PE-G4D
• Requires about half the mounting space of PE-B4 type.
compact square type. The PE-L series has analog outputs with the sensor and amplifier separated. The PE2-C series is cylindrical and with stable operating indicator. The PE-X3D is flat type, and
PE-X15D series
(See page 05/36)
• Square-flat type
• DC supply/3-wire, 12/24V DC
• Operating distance: 15mm PE-4BS2 series is multiple type. The PE-G4D is space-saving square type.
PE-T series
(See page 05/36)
• Unique “Magnetic Shield Method”
permits side-by-side mounting
• Only 12mm thick – achieved with IC
• Built-in reverse polarity and surge
voltage protection
AF89-458
PE2-CTS
05
(See page 05/39)
(See page 05/43)
(See page 05/47)
(See page 05/49)
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/25
Page 29
Proximity Switches
General information
PM-4M
AES202B-1A
AER201L-1A
X-806
PM-1U
FA-1446
PM-2S
FA-1445
AEQ010-1A
AF9-49
X806
FA-1446
AES, AER and PM type proximity switches (Magnetically-operated reed switches)
In the standard type PM the reed switch element and the sensing magnet are separate elements. The AES type is also a separate type but is a miniaturized version. In the AER type the sensing magnet element and the reed switch are integrated in one housing.
Features
• Since these proximity switches make use of a permanent magnet no external power source is required to operate the reed switch.
• The dry reed contact switch is dependable in operation and has an extended service life.
• The unit strongly resists vibration and is both water-and dust-tight (except for AES type).
• Either an AC or DC power source can be used for the reed switch output.
• Compact in design and easy to install anywhere.
• Can be mounted on a steel frame (In this case the effective operating distance is reduced by one-half).
For further information
See pages 05/51, 52, 54, 55.
Inductive type
Description Standard metal plate (object)
Standard metal plate (object) is a standard sensing target to measure the basic performance. Its shape, size, and material are stipulated. Iron is usually used as material.
L
W
t
Operating distance
The operating distance is the distance along the center axis of the head from the sensing head to the point where a metal plate traveling along the path actuates the switch. Normally the operating distance means this distance in vertical direction.
Reset(OFF)
Operate(ON)
Standard metal plate
The following curves indicate typical operating distances. Values for aluminum or copper will be less than 1/2 those indicated for iron. In order for an object to be detected, its dimensions must be no smaller than 30 × 30mm, or no larger than 70 × 70mm. Objects smaller or larger will not be detected, regardless of material.
22
20
18
16
14
Operating distance (mm)
12
10
8
Differential
Operating distance
Sensing head
Center axis
Operating
Thickness:1mm
Resetting distance
Fe
Resetting
Cu
Differential distance
This is the distance between the actuating point where the switch is actuated and the reset point where the switch resets after the metal plate is withdrawn from the sensing head.
Response curve
This curve shows the detect-to-reset range with object distance from the head. The switch operates when the object approaching form the left reaches point P on curve ‘a’, and resets when the trailing edge of the object reaches point Q on curve ‘b’. The switch also resets when the object is withdrawn from point P to R on curve ‘d’.
Resetting distance
Operating distance
Y
Q
XX
d
a
Resetting point
b c
Metal plate
R
P
Operating point
Sensing head
05/26
50sq
30sq
20sq
Size of metal plate (mm square)
70sq
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 30
Proximity Switches
Magnet
m
Reed switch
Operating position Reset position Range of reset points Range of operating points
General information
Magnetically operated type
Operating
These switches comprise a sensor and a reed switch element, which closes when a magnetic object approaches.
Reed switch
The constructions of the reed switch and its magnetic element are shown in the diagram. The reed switch is made up of two magnetic reeds in an airtight glass tube. The 2 reeds are magnetized when they come within the magnetic field of the magnetic element. In this case the tips of these 2 reeds have positive and negative charges respectively and are attracted to each other. When the magnetic field is removed the magnetic charge is lost and the reed switch opens. FUJI’s reed switches are designed to operate in the same manner as the snap-action of conventional limit switches.
Magnet
N S
S N
Operating characteristics Short axis
Magnet: Travel Reed switch: Fixed The reed switch closes when ‘m’ the magnet center reaches ‘쐌’ position. It resets at ‘x’ position.
Operating position Reset position Range of reset points Range of operating points
Magnet
m
m
Reed switch
m
Long axis
Magnet: Travel Reed switch: Fixed This method is feasible but if the distance between the magnet and the reed switch is not correct the reed switch may switch 3 times when the magnet carries out only 1 travel. Try to avoid using this arrangement.
05
Reed switch
Airtight glass tube
Mode of operation
The operation methods of the magnetic type proximity switches are as illustrated.
Separation type
Magnet Magnet Magnet
Reed switch
Reed switch is fixed but magnet moves in a vertical direction.
Reed switch is fixed but magnet moves in a horizontal direction.
Reed switch
Metal piece
Both the reed switch and magnet are fixed. And metal object passes between these two.
Reed switch
Integrated type
Proximity limit switch
Proximity limit switch
Short axis
Magnet: Fixed Reed switch: Fixed (In this case the reed switch operates as an NC contact.) Reed switch closes when the metal piece is out of ‘X’ region between the magnet and the reed switch. When the metal piece passes through the ‘X’ region the reed switch will open. Thus the reed switch opens as soon as ‘c’ the tip of the metal piece reaches ‘X’ region and closes as soon as ‘d’ the end leaves ‘Y’ region.
Reed switch
dcc
Metal piece
Magnet
d
Y area (Resetting) X area (Operating)
Proximity switch is fixed and the metal object moves in a horizontal direction.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Metal pieceMetal piece
Proximity switch is fixed and the metal piece moves forwards and backwards.
05/27
Page 31
Proximity Switches
8
25±0.2
35
25
ø5.3
55
0.5
65
50
4
Operating indicator
0.5mm x 3 core
Cable = 1m
2

PE-U12D and PE-U25NT

Inductive proximity switches–Slot type, PE-U
Supply voltage: 12/24V DC Output: Transistor 50, 100mA max. Operating distance: 7, 10mm
Features
• The slot type detecting surfaces of 12 and 25mm are available. Stable detection characteristics can be obtained when a metal plate passes through the slot ON or OFF-center.
• Best suited for detection of magnetic metal plates passing through the slot.
Specifications
Type (Ordering code) Operating distance Standard target size (iron) Supply voltage Operating voltage range Power consumption Output capacity Response time or frequency Differential Ambient temperature Degree of protection Insulation resistance Dielectric strength Mass
Note: * This indicates the distance “a” shown in
figure at right.
PE-U25NT (PE1U25-ND) 10mm ± 2* 50 × 50 × 2.3mm 12/24V DC 10 to 30V DC Max. 20mA at 24V DC Max. 100mA Max. 3ms. (ON time)
0.3 to 2mm –25 to +70°C IP67 (IEC) Over 50M at 500V DC 2000V AC rms. 1minute 210g
• Provided with built-in reverse polarity and surge voltage protection circuits.
• LED indicator lamps are provided, thus facilitating operational checks.
• Degree of protection meets the requirement of IP67 (IEC), thus permitting operation in unfavorable environments.
• NPN transistor voltage/current outputs are provided, thus permitting a wide range of applications.
PE-U12D (PE1U12-D) 7mm ± 1* 40 × 40 × 1mm
Max. 15mA at 24V DC Max. 50mA Min. 50Hz Max. 15% of operating distance
1000V AC rms. 1minute 120g
a
Target
PE-U12D: 4mm PE-U25NT: 15mm
Target
PE-U12D
AF91-511
Response curve
PE-U12D
X
Y
4
X (mm)
6 4 2 0 642
PE-U25NT
Y (mm)
X (mm)
X
15
Y
6
810
2
4
16 14
12 10
8 6 4 2
0
Y (mm)
10
8
6
4
2
PE-U25NT
SM-81
Target 40x40x1mm iron
Target 50x50x2.3mm iron
OFF
ON
642
810
OFF ON
X (mm)
Wiring diagrams
PE-U12D
Brown
4.7k
Black
Blue
Proximity switch
NPN transistor current output, 1NO
PE-U25NT
Promixity
Object
NPN transistor voltage/current output, SPDT
05/28
switch
Load
4.7k
10k 10k
+
Brown
Black (N.O)
White (N.C)
Blue
Load 2
Dimensions, mm
PE-U12D
+
50
30
40
35
47.5
8.5
Cable = 1m
0.2mm 3 core
PE-U25NT
5
4.5
25
40
12
Ordering information
ø4
Specify the following:
1.Type number or ordering code
2
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 32
Proximity Switches

PE1-C, PE1-Y

Inductive proximity switches– Cylindrical type, PE1-C, PE1-Y
Operating system
DC supply/3-wire and 2-wire system
AC supply/2-wire system Operating distance: 0.8 to 20mm This proximity switch has a cylindrical shape. The sensor is fitted to an end of the cylinder and the body is provided with a built-in control circuit. This type conforms to the requirements of the CENELEC (Europe) Standards and as the dimensions, ratings and performance comply with the
Type number nomenclature
Basic type Series
C: Cylindrical, screwed Y: Cylindrical, straight
Shield
Blank: Non-shielded S: Shielded
Operating distance
0.8 : 0.8mm 2 : 2mm 10 : 10mm 1 : 1mm 5 : 5mm
PE 1-C S 10 D B
Contact
Blank: 1NO B: 1NC
Operating system
D: DC, 3-wire, NPN Q: DC, 3-wire, PNP S: DC, 2-wire A: AC, 2-wire
requirements of these Standards, this type can be used as replacement units.
Features
• Short length because of the use of IC circuit.
• Shielded and non-shielded type are available.
• Red and green LED is provided for a stable operating indication and easy setting, mounting diameter M12 or more and NO contact type only.
• Provided with reverse polarity and surge voltage protection circuits.
• Degree of protection: IEC IP67
Ordering code
Basic type Series
Y: Cylindrical, straight C: Cylindrical, non-shielded S: Cylindrical, shielded
Operating distance
P8: 0.8mm 05: 5.0mm 1P: 1.5mm 10: 10.0mm 02: 2.0mm 20: 20.0mm
PE1-C PE1-Y
PE1 S 10-D B
Contact
Blank: 1NO B: 1NC
Operating system
D: DC, 3-wire, NPN Q: DC, 3-wire, PNP S: DC, 2-wire A: AC, 2-wire
KK02-299A
05
Specifications
Description
Shielded
Metal
Non-shielded
Metal
Operating system
DC supply 3-wire, NPN transistor output
DC supply 3-wire, PNP transistor output
DC supply 2-wire
AC supply 2-wire
DC supply 3-wire, NPN transistor output
DC supply 3-wire, PNP transistor output
DC supply 2-wire
AC supply 2-wire
Operating distance (mm)
0.8
0.8
1.5 2 5
10
0.8
0.8
1.5 2 5
10
2 5
10
2 5
10
2
5 10 20
2
5 10 20
5 10 20
5 10 20
Mounting diameter
4mm-dia. M5 M8 M12 M18 M30
4mm-dia. M5 M8 M12 M18 M30
M12 M18 M30
M12 M18 M30
M8 M12 M18 M30
M8 M12 M18 M30
M12 M18 M30
M12 M18 M30
Supply voltage (Operating voltage range)
12/24V DC (10 to 30V DC)
12/24V DC (10 to 30V DC)
12/24V DC (10 to 30V DC)
120/240V AC (45 to 260V AC)
12/24V DC (10 to 30V DC)
12/24V DC (10 to 30V DC)
120/240V AC (45 to 260V AC)
1NO Type Ordering
PE1-YS08D PE1YP8-D PE1-CS08D PE1SP8-D PE1-CS1R5D PE1S1P-D PE1-CS2D PE1S02-D PE1-CS5D PE1S05-D PE1-CS10D PE1S10-D
PE1-YS08Q PE1YP8-Q PE1-CS08Q PE1SP8-Q PE1-CS1R5Q PE1S1P-Q PE1-CS2Q PE1S02-Q PE1-CS5Q PE1S05-Q PE1-CS10Q PE1S10-Q
PE1-CS2S PE1S02-S PE1-CS5S PE1S05-S PE1-CS10S PE1S10-S
PE1-CS2A PE1S02-A PE1-CS5A PE1S05-A PE1-CS10A PE1S10-A
PE1-C2D PE1C02-D PE1-C5D PE1C05-D PE1-C10D PE1C10-D PE1-C20D PE1C20-D
PE1-C2Q PE1C02-Q PE1-C5Q PE1C05-Q PE1-C10Q PE1C10-Q PE1-C20Q PE1C20-Q
PE1-C5S PE1C05-S PE1-C10S PE1C10-S PE1-C20S PE1C20-S
PE1-C5A PE1C05-A PE1-C10A PE1C10-A PE1-C20A PE1C20-A
code
1NC Type Ordering
PE1-YS08DB PE1YP8-DB PE1-CS08DB PE1SP8-DB PE1-CS1R5DB PE1S1P-DB PE1-CS2DB PE1S02-DB PE1-CS5DB PE1S05-DB PE1-CS10DB PE1S10-DB
PE1-YS08QB PE1YP8-QB PE1-CS08QB PE1SP8-QB PE1-CS1R5QB PE1S1P-QB PE1-CS2QB PE1S02-QB PE1-CS5QB PE1S05-QB PE1-CS10QB PE1S10-QB
PE1-CS2SB PE1S02-SB PE1-CS5SB PE1S05-SB PE1-CS10SB PE1S10-SB
PE1-CS2AB PE1S02-AB PE1-CS5AB PE1S05-AB PE1-CS10AB PE1S10-AB
PE1-C2DB PE1C02-DB PE1-C5DB PE1C05-DB PE1-C10DB PE1C10-DB PE1-C20DB PE1C20-DB
PE1-C2QB PE1C02-QB PE1-C5QB PE1C05-QB PE1-C10QB PE1C10-QB PE1-C20QB PE1C20-QB
PE1-C5SB PE1C05-SB PE1-C10SB PE1C10-SB PE1-C20SB PE1C20-SB
PE1-C5AB PE1C05-AB PE1-C10AB PE1C10-AB PE1-C20AB PE1C20-AB
code
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/29
Page 33
Proximity Switches
PE1-C, PE1-Y
Specifications
Type PE1-YS08D, DB PE1-YS08Q, QB PE1-CSD, DB PE-CSQ, QB PE1-CSS, SB PE1-CSA, AB
Output NPN transistor, PNP transistor, NPN transistor, PNP transistor, Transistor Thyristor
Current consumption 10mA or less at 24V DC 15mA or less at 24V DC – Leakage current 0.8mA or less at 1.5mA or less at
Ambient temperature –25 to 70°C –25 to 80°C –25 to 80°C –25 to 80°C Dielectric strength 250V AC 1 min. 1000V AC 1min. 1000V AC 1 min. 2000V AC 1 min. Insulation resistance 50M or more at 250V DC megger 50M or more at 500V DC megger Degree of protection IP67 (IEC Standard) Vibration 10-55Hz, 1.5mm double amplitude (in X, Y, Z directions, respectively for 2 hours) Shock 500m/s Protection circuit Reverse polarity and surge voltage Reverse polarity, short-circuit and surge voltage Surge voltage
PE1-CS08D, DB PE1-CS08Q, QB PE1-CD, DB PE1-CQ, QB PE1-CS, SB PE1-CA, AB
open collector open collector open collector open collector output output output output output output
24V DC 200V AC
2
Response frequency
Type Frequency (Hz) PE1-CS1R5D, 5DB, 5Q, 5QB 2000 PE1-CS2D, 2DB, 2Q, 2QB 1500 PE1-YS08D, 08DB, 08Q, 08QB 1000
PE1-CS08D, 08DB, 08Q, 08QB PE1-CS2S, 2SB
PE1-C2D, 2DB, 2Q, 2QB 800 PE1-C5S, 5SB
PE1-CS5D, 5DB, 5Q, 5QB 600 PE1-CS5S, 5SB 500 PE1-CS10D, 10DB, 10Q, 10QB, 10S, 10SB 400
PE1-C5D, 5DB, 5Q, 5QB, 10S, 10SB PE1-C10D, 10DB, 10Q, 10QB 200 PE1-C20D, 20DB, 20Q, 20QB 100 PE1-CS2A, 2AB, 5A, 5AB, 10A, 10AB 25
PE1-C5A, 5AB, 10A, 10AB, 20A, 20AB
Accessories (optional)
Mounting brackets
Type Ordering Dimensions, mm Screw Used with
PX1-P4 PE1Z0036 13 7.5 6 20 M3 × 10 PE1-YS08 PX1-P8 PE1Z0037 18 10 18 28 M4 × 20 PE1-CS1R5
PX1-P12 PE1Z0033 24 12.5 20 37 M4 × 25 PE1-CS2
PX1-P18 PE1Z0034 32 17 30 47 M5 × 32 PE1-CS5
PX1-P30 PE1Z0035 45 17 50 60 M5 × 50 PE1-CS10
code
ABCD
(supplied)
PE1-C2
PE1-C5
PE1-C10
PE1-C20
Output capacity
Type Output PE1-YS08D, 08DB, 08Q, 08QB Current output*1100mA max.
PE1-CS08D, 08DB, 08Q, 08QB PE1-CS1R5D, 5DB, 5Q, 5QB Current output*1200mA max.
PE1-CS2D, 2DB, 2Q, 2QB PE1-CS5D, 5DB, 5Q, 5QB PE1-CS10D, 10DB, 10Q, 10QB PE1-C2D, 2DB, 2Q, 2QB PE1-C5D, 5DB, 5Q, 5QB PE1-C10D, 10DB, 10Q, 10QB PE1-C20D, 20DB, 20Q, 20QB
PE1-CS2S, 2SB, 5S, 5SB, 10S, 10SB Current output 3 to 200mA PE1-C5S, 5SB, 10S, 10SB, 20S, 20SB
PE1-CS2A, 2AB, 5A, 5AB, 10A, 10AB Current output*25 to 200mA PE1-C5A, 5AB, 10A, 10AB, 20A, 20AB
*1Transistor, open collector output *2Refer to output capacity derating curve,
see page 05/128
Surface protection covers
Type Ordering Dimensions, mm Used with
PX1-C12S PE1Z0030 ø15 5 0.6 PE1-CS2 PX1-C18S PE1Z0031 ø22.5 8 1.1 PE1-CS5 PX1-C30S PE1Z0032 ø35 12 1.6 PE1-CS10
code
KK02-301A
ABC
B C
A
PX1-P4 PX1-P8 to P30
A
B
C
D
A
B
C
D
05/30
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 34
Response curve for iron (Typical)
PE1-YS08 PE1-CS08
Y(mm)
X
Y
0.8
0.6
0.4
0.2
21012
5x5x1mm (lron)
x(mm)
PE1-CS5 PE1-C10
Y
Y (mm) 10
PE1-C10
X
5
682468
42
0
30x30x1mm (lron)
PE1-CS5
18x18x1mm (lron)
x (mm)
PE1-CS1R5 PE1-C2
X
Y
Proximity Switches
PE1-C, PE1-Y
Y (mm)
2
PE1-C20
1.5
1
0.5
210 12
33
12x12x1mm(lron)
PE1-CS1
8x8x1mm(lron)
x (mm)
PE1-CS10 PE1-C20
X
Y
Y (mm) 20
PE1-C20 60x60x1mm (lron)
PE1-CS10
10
30x30x1mm (lron)
84
1216 4 8 12 16
0
x (mm)
PE1-CS2 PE1-C5
Y
Y(mm)
PE1-C5
X
505
5
2
15x15x1mm (lron)
PE1-CS2
12x12x1mm (lron)
Output capacity derating PE1-CA
x (mm)
Wiring diagrams
DC supply/3-wire system, NPN transistor output DC supply/2-wire system
PE1-CS (1NO, 1NC)
Proximity switch
Brown
Black
Blue
Load
10-30V DC
Proximity switch
Brown
Blue
DC supply/3-wire system, PNP transistor output AC supply/2-wire system
PE1-CA (1NO, 1NC)
Proximity switch
Brown
Proximity switch
Brown
Black
10-30V DC
Load
Blue
200
160
120
Output current (mA)
020406080
Ambient temperature (°C)
Load
10-30V DC
Load
Load
45-260V AC
Blue
Load
05
Mutual interference
Be sure to space two switches at a distance greater than that shown in the table at right to prevent mutual interference.
Type A (mm) B (mm) PE1-YS08 10 5
PE1-CS08 10 5 PE1-CS1R5 20 15 PE1-CS2 30 (15) 20 (12) PE1-CS5 50 (25) 30 (18) PE1-CS10 100 (50) 70 (35)
A
B
PE1-C2 30 30 PE1-C5 80 (40) 80 (40) PE1-C10 200 (100) 120 (60) PE1-C20 300 (150) 200 (100)
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Note: The values in parentheses are applicable
when using two switches with oscillation frequencies different from each other.
05/31
Page 35
Proximity Switches
24
M18 P=1
4
37
53 2000
Indicator
Wave washer
IV cable 0.5mm
2
ø6
PE1-C, PE1-Y
Dimensions, mm Shielded
PE1-YS08 PE1-CS08 PE1-CS1R5
25
ø4
17
Mass: 30g Mass: 40g
Indicator
2000
ø3
IV cable 0.14mm
Toothed lock washer
M5=P0.5
25
10
3.2
17
8
2
Indicator
2000
ø3
IV cable 0.14mm
M8 P=1
2
13
Mass: 30g
Toothed
Indicator
lock
4
washer
27
37
ø3
IV cable 0.14mm
2000
2
PE1-CS2 PE1-CS5
lock washer
IndicatorToothed
ø4
IV cable
2
0.3mm
for 2-wire
2
0.2mm
for 3-wire
2000
4
M12 P=1
17
30
43
PE1-CS2A
17
P=1
M12
lock washer
IndicatorToothed
IV cable 0.3mm
ø4
2
2000
4
45
58
Mass: 70g Mass: 100g Mass: 160g
PE1-CS10
Wave washer
M30 P=1.5
5
42
Indicator
ø6
IV cable 0.5mm
58
2000
Wave
4
Indicator
washer
P=1
M18
24
48
64
ø6
IV cable 0.5mm
2000
2
36
PE1-CS10APE1-CS5A
2
36
Mass: 170g Mass: 280g Mass: 340g
Non-shielded
PE1-C2 PE1-C5
13
Mass: 40g Mass: 70g Mass: 100g
M8 P=1
Toothed lock washer
4
5
27
37 2000
Indicator
IV cable 0.14mm
Indicator
Toothed lock
4
ø3
2
M12 P=1
17
washer
7
30
43 2000
IV cable
0.3mm
0.3mm
ø4
2
for 2-wire
2
for 3-wire
PE1-C5A
17
P=1
M12
5
Wave washer
P=1.5
M30
52
Toothed
4
lock washer
7
45
58
Indicator
ø6
2
IV cable 0.5mm
Indicator
2000
ø4
IV cable 0.3mm
2000
2
68
2
PE1-C10A
24
P=1
M18
4
PE1-C20
Wave
Indicator
washer
10
48
64
ø6
IV cable 0.5mm
2000
2
PE1-C10
24
M18 P=1
4
Wave
Indicator
washer
ø6
10
37
53
IV cable 0.5mm
2000
Mass: 160g Mass: 170g Mass: 280g
PE1-C20A
P=1.5
M30
36
Wave washer
5
15
52
68
Indicator
ø6
IV cable 0.5mm
2000
2
Mass: 340g
05/32
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Wave washer
5
M30 P=1.5
15
36
42
Indicator
ø6
2
IV cable 0.5mm
58
2000
Information subject to change without notice
Page 36
Proximity Switches

PE-B

Inductive proximity switches– Square type, PE-B
Supply voltage:
10-30V DC 80-250V AC, 50/60Hz
Operating distance: 4 to 50mm
Features
• Operating distance from 4mm to 50mm permits a variety of applications.
• LED’s for operating indication lamp are provided for all types thus facilitating operation checks.
Type number nomenclature
Basic type Series
B: Square shaped
Operating distance
4: 4mm 20: 20mm 7: 7mm 30: 30mm 10:10mm 50: 50mm 15:15mm
PE – B 4 D 3 B
Contact
Blank: 1NO B: 1NC
Sensing head direction
Blank: Standard 3: Upper side
Operating system
D: DC, 3-wire, NPN output Q:DC, 3-wire, PNP output A: AC, 2-wire S: DC, 2-wire
• Ones with an operating distance of over 20mm meet the requirements of the CENELEC Standards.
• Wide operating voltage range Operating range of supply voltage is from 80 to 250V AC or from 10 to 30V DC.
• Provided with built-in reverse polarity and surge voltage protection circuits.
• PNP output types are also available thus permitting application to machine tools in Europe.
Ordering code
Basic type Series
B: Square shaped
Operating distance
04: 4mm 20: 20mm
(PE–B4 only)
07: 7mm 30: 30mm 10: 10mm 50: 50mm 15: 15mm
PE-B
PE1 B 10 – D B 3
SK-588
Sensing head direction
Blank: Standard 3: Upper side
(PE-B4 only)
Contact
Blank: 1NO B: 1NC
Operating system
D: DC, 3-wire, NPN output Q: DC, 3-wire, PNP output A: AC, 2-wire S: DC, 3-wire
05
Versions
Operating Target Operating Output * Output * system size (mm) distance 1NO 1NC 1NO 1NC
DC supply 20 × 20 × 14 PE-B4D PE1B04-D PE-B4DB PE1B04-DB PE-B4Q PE1B04-Q PE-B4QB PE1B04-QB 3-wire 20 × 20 × 14 PE-B4D3 PE1B04-D3 PE-B4D3B
AC supply 30 × 30 × 17 PE-B7A PE1B07-A – – 2-wire 40 × 40 × 110 PE-B10A PE1B10-A –
DC supply 20 × 20 × 14 PE-B4S PE1B04-S PE-B4SB PE1B04-SB – 2-wire 30 × 30 × 17 PE-B7S PE1B07-S PE-B7SB PE1B07-SB –
Notes: *PE-BD: NPN transistor, open collector output
30 × 30 × 17 PE-B7D PE1B07-D PE-B7DB PE1B07-DB PE-B7Q PE1B07-Q PE-B7QB PE1B07-QB 40 × 40 × 110 PE-B10D PE1B10-D PE-B10DB PE1B10-DB PE-B10Q PE1B10-Q PE-B10QB PE1B10-QB 50 × 50 × 115 PE-B15D PE1B15-D PE-B15DB PE1B15-DB – 50 × 50 × 120 PE-B20D PE1B20-D PE-B20DB PE1B20-DB PE-B20Q PE1B20-Q PE-B20QB PE1B20-QB 90 × 90 × 130 PE-B30D PE1B30-D PE-B30DB PE1B30-DB PE-B30Q PE1B30-Q PE-B30QB PE1B30-QB
150 × 150 × 150 PE-B50D PE1B50-D PE-B50DB PE1B50-DB PE-B50Q PE1B50-Q PE-B50QB PE1B50-QB
50 × 50 × 120 PE-B20A PE1B20-A – 90 × 90 × 130 PE-B30A PE1B30-A PE-B30AB PE1B30-AB –
150 × 150 × 150 PE-B50A PE1B50-A PE-B50AB PE1B50-AB –
40 × 40 × 110 PE-B10S PE1B10-S PE-B10SB PE1B10-SB – 50 × 50 × 120 PE-B20S PE1B20-S PE-B20SB PE1B20-SB – 90 × 90 × 130 PE-B30S PE1B30-S PE-B30SB PE1B30-SB –
150 × 150 × 150 PE-B50S PE1B50-S PE-B50SB PE1B50-SB –
PE-BQ: PNP transistor, open collector output PE-BA: Thyristor output PE-BS: Transistor output
(mm) Type Ordering Type Ordering Type Ordering Type Ordering
code code code code
PE1B04-DB3
PE-B4Q3 PE1B04-Q3 PE-B4Q3B
PE1B04-QB3
Ordering information
Specify the following:
1. Type number or ordering code
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/33
Page 37
Proximity Switches
PE-B
Specifications
Type PE-BD, PE-BDB PE-BQ, PE-BQB PE-BS, PE-BSB PE-BA, PE-BAB Output NPN transistor, PNP transistor, Transistor, output Thyristor, output
Supply voltage 12/24V DC * Output capacity Max. 200mA at 12/24V DC Max. 100mA 10 to 200mA
Current consumption Max. 15mA at 24V DC 0.8mA or less 2mA at 200V AC
Ambient temperature –25 to +75°C –25 to +75°C –25 to +75°C Dielectric strength 2000V AC, 1 min. 2000V AC, 1 min. 2000V AC, 1 min. Insulation resistance Over 50M (500V DC megger) Degree of protection IP67 (IEC) Response frequency See table below Vibration 10 to 55Hz, 1.5mm double amplitude (in X, Y and Z direction, respectively for two hours) Shock 500m/s Circuit protection Short-circuit (except PE-BA and PE-BAB), reverse polarity, surge voltage
Notes: *1Operational voltage range: 10 to 30V DC *2 Operational voltage range: 80 to 250V AC.
open collector output open collector output
1
(PE-B4D, PE-B4Q: Max. 50mA at 12/24V DC)
2
12/24V DC *
1
120/240V AC *
2
(Leakage current) (Leakage current)
Response frequency DC supply
PE-B7D, PE-B7Q, PE-B7S 300Hz PE-B4D, PE-B4Q, PE-B4S 200Hz RE-B10D, PE-B10Q, PE-B10S
Response curve for iron (Typical)
PE-B4
Material: Iron 20 × 20 × 1mm
X
Y
PE-B20
Material: Iron 50 × 50 × 1mm
X
Y
Y (mm)
4
3
2
1
055
Y (mm)
20
15
10
5
PE-B7
Material: Iron 30 × 30 × 1mm
X
X (mm)
PE-B15D, PE-B20D, PE-B20Q, PE-B20S PE-B30D, PE-B30Q, PE-B30S 50Hz PE-B50D, PE-B50Q, PE-B50S 10Hz
PE-B10
Material: Iron 40 × 40 × 1mm
Y (mm)
8
6
4
Y
2
012 484812
X (mm)
X
Y
5
PE-B30
Material: Iron 90 × 90 × 1mm
Y (mm)
X
Y
30
20
10
Y (mm)
10
5
010
100Hz
510
AC supply
PE-B7A, PE-B10A, PE-B20A 20Hz PE-B30A, PE-B50A 5Hz
PE-B15
Material: Iron 50 × 50 × 1mm
Y (mm) 15
X
Y
X (mm)
15 5 10 15
PE-B50
Material: Iron 150 × 150 × 1mm
X
Y
Y (mm)
60
40
20
10
5
010
5
X (mm)
15 10 5 5 10 15
05/34
X (mm)
30 20 10 10 20 30
0
X (mm)
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
40 20 20 40
0
X (mm)
Information subject to change without notice
Page 38
Wiring diagrams
Brown
Blue
Load
Load
Proximity switch
80-250V AC
B
DC supply/3-wire system
PE-BD
Proximity switch
PE-BQ
Brown
Black
Blue
Load
Brown
10-30V DC
DC supply/2-wire system
PE-BS
Proximity switch
Brown
Load
Blue
Load
10-30V DC
Proximity Switches
PE-B
AC supply/2-wire system
PE-BA
Proximity switch
Black
10-30V DC
Load
Blue
Dimensions, mm
PE-B4, B43 PE-B4B, B43B PE-B7, PE-B7B PE-B10, PE-B10B
Sensor surface (PE-B4M3)
Sensor surface (PE-B4M)
6
12
3.5
30
12
0.3
PE-B15D, PE-B15DB
LED
35
Sensor surface
35
35
42
48
18
25
20.5
LED
ø6
18
2
18.5
1000
0.5mm
Sensor surface
30
0.5
33.5
38.5
13
4.3
1.5
PE-B30, PE-B30B
LED
ø6
30
5.5
2
45
53
1000
30
0.5mm
2
60
Mass: 180g
LED
ø3
29
21
9.5 15
1000
Mass: 30g Mass: 90g Mass: 120g
2.3
0.14mm
2
Sensor surface
25
0.5
PE-B20, PE-B20B
2-(7.6 x 4.8)
Sensor surface
40
40
0.5
ø6
23
1000
24
Mass: 180g
0.5mm
2
LED
30
34
17
60
45
45
2
5.3
2
2000
4.3
ø6
ø6
22
100040
21.5
LED
Mass: 330g
0.5mm
05
2
40
26
PE-B50, PE-B50B
80
65
65
80
2
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
2000
ø6
5.3
40
26
LED
Mass: 580g
Mutual interference:
Be sure to space two switches at a distance greater than that shown in the table at right to prevent mutual interference.
Type A (mm) B (mm) PE-B4 60 (30) 60 (30) BE-B7 80 (40) 80 (40) PE-B10 120 (60) 120 (60) PE-B15 200 (100) 120 (60) PE-B20 200 (100) 200 (100)
A
PE-B30 300 (150) 300 (150) PE-B50 500 (250) 500 (250)
Note: The values in parentheses are applicable
when using two switches with oscillation frequencies different from each other.
05/35
Page 39
Proximity Switches
10mm min.
60mm min.
Metal
Metal

PE-X15D

Inductive proximity switches– Square flat type, PE-X15D
Operating system:
DC supply/3-wire system Supply voltage range: 10 to 30V DC Operating distance: 15mm
Features
• Degree of protection meets the
requirements of IEC IP66, thus
permitting operations in unfavorable
environment.
Specifications
Type (Ordering code) Operating system Output Operating distance Target size (iron) Differential distance Rated voltage Switching capacity Current consumption Residual voltage Response frequency Variation due to voltage
fluctuation Variation due to temperature
fluctuation Dielectric strength Insulation resistance Degree of protection Ambient temperature Humidity Vibration Shock
PE-X15D
DC supply/3-wire NPN transistor, open collector, 1NO 15mm ±10% 50×50×1mm (iron) Max. ±10% of operating distance 12/24V DC (10 to 30V DC) 200mA max. 15mA max. at 24V DC
1.5V max. at 24V DC, 200mA 100Hz Max. ±1% of operating distance at 12/24V DC when
operated within 10 to 30V DC Max. ±10% of operating distance at 20°C within
temperature range of –25 to +70°C 1000V AC, 1min. 50M or more (500V DC) IP66 (IEC) –25 to +70°C (avoid icing) 35 to 95% RH 10–55Hz, 1.5mm double amplitude 500m/s2 (approx. 50G)
• Only two screws are needed to affix each switch, eliminating the need for exclusive mounting brackets.
• Incorporates surge suppression circuits and protection circuits against reverse polarity and short­circuits.
PE-X15D
Response curve for iron
Material: Iron 50×50×1mm
Y (mm) 15
X
Y
15 5 10 15
Influence of surronding metals:
When mounting a proximity switch surrounded by metals, be sure to provide a minimum distance as shown below.
10
5
010
5
X (mm)
Wiring diagrams
Proximity switch
05/36
Brown
Black
Blue
Load
Dimensions, mm
10-30V DC
35
23
12
28
ø28
28 35 2000
5
indicator
4–ø3.5
ø4
10±3
30±5
IV cable 0.2mm
8
2
Mass: 80g
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 40
Proximity Switches

PE-T

Inductive proximity switches– Slim type, PE-T
Supply voltage: 12/24V DC
120/240V AC
Output capacity: Max. 200mA
• Wide operating voltage range Operating range of supply voltage is from 80 to 250V AC or from 10 to 30V DC.
• LED indicators are provided for all types thus facilitating operation
Features
• Unusual “Magnetic Shield Method” permits to mount these units side by side, touching each other. (Shielded type PE-TS2)
• Only 12mm in thickness because of the use of IC.
Versions
Description Operating Target Operating Output
system size (mm) distance 1NO 1NC
Shielded DC supply/3-wire 12 × 12 × 12 PE-TS2D PE1T02-D PE-TS2DB PE1T02-DB
DC supply/2-wire 12 × 12 × 12 PE-TS2S PE1T02-S PE-TS2SB PE1T02-SB AC supply/2-wire 12 × 12 × 12 PE-TS2A PE1T02-A
Non-shielded DC supply/3-wire 20 × 20 × 14 PE-T4D PE1N04-D PE-T4DB PE1N04-DB
DC supply/2-wire 20 × 20 × 14 PE-T4S PE1N04-S PE-T4SB PE1N04-SB AC supply/2-wire 20 × 20 × 14 PE-T4A PE1N04-A
checks.
• Provided with built-in reverse polarity and surge voltage protection circuits.
• Water and oil-tight Degree of protection meets the requirements of IEC IP67 thus permitting operations in unfavorable environment.
(mm) Type Ordering Type Ordering
PE-TS2Q PE1T02-Q PE-TS2QB PE1T02-QB
PE-T4Q PE1N04-Q PE-T4QB PE1N04-QB
PE-T
Ordering information
Specify the following:
1.Type number or ordering code
code code
AF89-744
05
Specifications
Type Output
Supply voltage Output capacity Current consumption
Ambient temperature Dielectric strength Insulation resistance Degree of protection Response frequency
Notes: *1Operating voltage range: 10 to 30V DC *2 Operating voltage range: 80 to 250V AC.
PE-TS2D, PE-T4D
NPN transistor, open collector output 12/24V DC* Max. 200mA Max. 15mA at 24V DC
–25 to +70°C 2000V AC, 1 min. Over 50M (500V DC) IP67 (IEC) See table below
1
PE-TS2Q, PE-T4Q
PNP transistor, open collector output
–25 to +70°C 2000V AC 1 min. Over 50M at 500V DC IP67 (IEC)
Response curve for iron
PE-TS2
12x12x1mm (lron)
X
Y (mm)
2
Y
1
PE-T4
20x20x1mm (lron)
X
Y
Y (mm)
4
3
2
1
PE-TS2S, PE-T4S
Transistor output
Max. 0.8mA (Leakage current) –25 to +70°C 2000V AC, 1 min. Over 50M (at 500V DC) IP67 (IEC)
Response frequency DC supply types
PE-TS2D, PE-TS2Q 800Hz PE-TS2S PE-T4D, PE-T4Q 250Hz PE-T4S
AC supply types
PE-TS2A, PE-T4A 20Hz
PE-TS2A, PE-T4A
Thyristor output
120/240V AC* 10 to 200mA Max. 2mA at 200V AC (Leakage current) –25 to +70°C 2000V AC 1 min. Over 50M (at 500V DC) IP67 (IEC)
2
202
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
X (mm)
55
Information subject to change without notice
0
X (mm)
05/37
Page 41
Proximity Switches
PE-T
Type number nomenclature PE – TS 2 – D B
Contact
Blank: 1NO B: 1NC
Operating system
D: DC, 3-wire, NPN output Q: DC, 3-wire, PNP output S: DC, 2-wire A: AC, 2-wire
Operating distance
2: 2mm 4: 4mm
Series
TS: Shielded, slim type N: Non-shielded, slim type
Basic type
Wiring diagrams DC supply/3-wire system
PE-TD
Proximity switch
Blue
Brown
Black
Load
10-30V DC
Ordering code PE1 T 02 – D B
Contact
Blank: 1NO B: 1NC
Operating system
D: DC, 3-wire, NPN output Q: DC, 3-wire, PNP output S: DC, 2-wire A: AC, 2-wire
Operating distance
02: 2mm 04: 4mm
Series
T: Shielded, slim type N: Non-shielded, slim type
Basic type
Dimensions, mm
Sensor surface
6
32±0.2
4
4
17±0.2
26
2- ø3.1
2·M3 depth 6
40
ø4
16±0.2
59
12
Mass : 50g
PE-TQ
Proximity switch
DC supply/2-wire system
PE-TS
Proximity switch
AC supply/2-wire system
PE-TA
Proximity switch
Brown
Blue
Brown
Blue
Blue
Load
Load
Load
Load
Brown
Black
Load
10-30V DC
80-250V AC
10-30V DC
Mutual interference:
Be sure to space two switches at a distance greater than that shown in the table below to prevent mutual interference.
Type
PE-TS2 PE-T4
A (mm) 24(12) 60(30)
A
B (mm) 24(12) 60(30)
Note: The values in parentheses are
B
applicable when using two switches with oscillation frequencies different from each other.
05/38
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 42
Proximity Switches
Sensor PE-LS
Amplifier PE-LA
쏔쏔
Analog output
Motor control
ON/OFF output
Recorder etc.
ON/OFF output
Detecting level
Analog output
Detecting of welded joint
V
I
Sensor PE-LS
Amplifier PE-LA
쏔쏔
Anolog output
Motor control

PE-L

Inductive proximity switches­Analog output type, PE-L
• The accuracy of linearity is ±1.5% of full scale and the resolution accuracy ±0.05% of full scale, thus permitting a
Description
These switches are ideally suited for deformation inspections, position controls of laser beam machines and similar displacement measurements and controls of a variety of machines.
Features
• Red LED indicator lamp
• Output voltage proportional to the
highly accurate measurement and detection of minute displacement of distance.
• Provided with 2 switching output circuits so as to detect an arbitrary position within the detecting range by incorporating a built-in comparator circuit.
• Provided with a SPAN indicator lamp.
distance from the object.
Sensor Amplifier unit
External Type Ordering diameter code
M12 PE-LS2 PE1L02 M18 PE-LS5 PE1L05 M30 PE-LS10 PE1L10
12/24V DC 110V AC 220V AC Type Ordering Type Ordering Type Ordering
PE-LA2D PE1LA02-T PE-LA2A/1 PE1LA02-H PE-LA2A/2 PE1LA02-M PE-LA5D PE1LA05-T PE-LA5A/1 PE1LA05-H PE-LA5A/2 PE1LA05-M PE-LA10D PE1LA10-T PE-LA10A/1 PE1LA10-H PE-LA10A/2 PE1LA10-M
Specifications Sensor
Type Rated operating distance Standard material of target Operating distance range
Standard target size (Iron) t: thickness Response frequency
Ambient temperature Degree of protection
Mass (Includes a 3m prewired cable)
PE-LS2
2mm Magnetic materials
0.4–2mm 12 x 12 x 1t 10kHz
–25 to +70°C IP67 (IEC)
90g
PE-LS5
5mm
1–5mm 18 x 18 x 1t 5kHz
120g
PE-LA
PE-LS
code code code
Application examples
PE-LS10
10mm
2–10mm 30 x 30 x 1t 2kHz
220g
Detecting of height and thickness of product
Sensor PE-LSM
B line
Position control for laser beam machine
Amplifier PE-LAMM
Reject signal
Conveyor
A line
OUT1 OUT2
BABA
Product
OUT1 Setting level OUT2 Setting level
SP-387
05
Amplifier
Description Supply voltage Power consumption Analog output
characteristic Switching output
characteristic Adjustment
function
Output
Indicator Ambient temperature Mass Socket
Note: * Operating voltage range 100V: 85-121V AC
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Resolution Linearity
Differential
Analog output voltage adjustment
Switching output adjustment
Analog output Switching
output
DC supply 12/24V DC 30mA max.
0.05% of full scale ±1.5% of full scale
1 to 5% of rated operating distance
1 Volt adj.
Adjustment for output voltage of 1 Volt at 20% of rated operating distance
5 Volts adj.
Output 1 adj.
Adjustment for output voltage of 5 Volts at rated operating distance
Adjustment for operating position of ON/OFF output
Output 2 adj.
1 to 5 Volts
Output 1 Output 2
NPN transistor output 100mA max. (30V DC)
SPAN indicator, Switching output indicator –10 to +55°C 100g TP28S, TP28X, ATX1NS (8-pin)
200V: 170–242V AC
AC supply 110, 220V AC, 50/60 Hz* 40mA max.
180g
Measuring of plate and welded joint thickness
Feed control for grinder wheel
Amplifier PE-LA
쏔쏔
Analog output
Motor control
Sensor
PE-LS
Ordering information
Specify the following:
1.Type number (ordering code)
05/39
Page 43
Proximity Switches
PE-L
Typical characteristic data Distance-output voltage PE-LS2
6
PE-LS5 PE-LS10
6
6
5
4 3
2
Output voltage (V)
1
0
0.4 0.8 1.2 1.6 2.0 2.4 2.8 Distance (mm)
Size of target-Linearity PE-LS2
10
8 6 4 2
Linearity (% of FS)
0
– 2
0.4
8×8mm
12×12mm
30×30mm
0.8 1.2 1.6 2.0 Distance (mm)
5×5mm
18×18mm
5
4 3
2
Output voltage (V)
1
0
1234567
PE-LS5
10
8 6 4 2
Linearity (% of FS)
0
– 2
1
Distance (mm)
8×8mm
18×18mm
2345
Distance (mm)
12×12mm
30×30mm
5
4 3
2
Output voltage (V)
1
0
24681012 14
PE-LS10
10
8 6 4 2
Linearity (% of FS)
0
– 2
2
Distance (mm)
12×12mm
15×15mm
30×30mm
60×60mm
46810
Distance (mm)
Material of target-Output voltage PE-LS2
6
Brass
5
4
3
2
Output voltage (V)
1
0
0.4 0.8 1.2 1.6 2.0 2.4 2.8
Cu
AI
Distance (mm)
Stainless (SUS304)
Fe
PE-LS5
6
Brass
5
4
3
2
Output voltage (V)
1
0
1234567
Stainless (SUS304)
Cu
AI
Distance (mm)
Fe
PE-LS10
6
Brass
5
4
3
2
Output voltage (V)
1
0
24681012 14
Stainless (SUS304)
Cu
AL
Distance (mm)
Fe
05/40
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 44
Proximity Switches
9
4.5
34
43.5
71
56
52
M3.5 x 8
30
(33)
(48)
6.9
5
58.3
7.5 15
20
10
2
4.5
93.4 For TH35-15
85.9 For TH35-75
PE-L
Dimensions, mm Sensor
E
B
F
A
Type A B E F PE-LS2 M12×120 174
PE-LS5 M18×130 244 PE-LS10 M30×1.5 40 36 5
3000
ø3.1
Shielded wire
AWG 27
Adaptor/Flush mounting
76 60
47
25
Amplifier-unit
48 SQ
PE LA
6
93
72.5
Socket/Surface mounting
TP28S
(33)
30
6.9
4.5
4.5
9
43.5
5
711056
52
M3.5 x 8
(48)
34
43.5
Socket/Soldering terminal
ATX1NS
5
4
6
3
2
7
8
1
35
20
7.5
15
Mass: 56g
33
Mass: 18g
Socket/Rail mounting
TP28X
44 SQ
Mounting rails
TH35-7.5 (Steel)
7.5 1
27
35
Mass: 290g
TH35-7.5AL (Aluminum)
7.5 1
27
35
Mass: 140g
TH35-15AL (Aluminum)
15
1
25
27
35
Mass: 220g
44 x 20 = 880
900
44 x 20 = 880
20
900
44 x 20 = 880
20 20 10
900
Mass: 53g
12
5.5
20 10
20
05
12
5.5
20
10
12
5.5
Wiring diagrams
DC
Switching output 1
Shield
Sensor
Internal circuit of output (DC)
4.7k
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
6543
7812
Analog output
4.7k
Switching output 2
7 3
4
2
Load
Load Load
+
V
Load
AC
Power source for loads
(DC10 – 30V)
Shield
Switching
Sensor
Internal circuit of output (AC)
output 1
6 543
7 812
+
V
Analog output
Power source
Load Load
3 4
5
Load Load
Switching
output 2
Timing diagrams
100%
20%
SPAN indicator
Switching Output 2 (indication)
Switching Output 1 (indication)
OFF
ON
Position target
ON
OFF
OFF
ON
Switching Output 2 Setting of sensing point
Switching Output 1 Setting of sensing point
05/41
Page 45
Proximity Switches
PE-L
Handling of the amplifier unit Indicators and output adjusting dial
PE-LA

Adjustment of analog output
Order Position of
target
1
2
1/5th of rated operating distance
3
Rated operating distance
SP-385
1V adjusting dial

Used to adjust the output voltage to 1V when the standard size target is positioned at a point 1/5th of the rated operating distance.
5V adjusting dial
Used to adjust the output voltage 5V when the standard size target is positioned at the rated operating distance.
Operating distance adjusting dial (For switching output 2)
Operating distance adjusting dial (For switching output 1)
Operating indicator (Red)
This lamp is used to indicate the operating state of output 1. (Lights up when the output is ON. Goes out when the output is OFF)
Operating indicator (Red)
This lamp is used to indicate the operating state of output 2. (Lights up when the output is ON. Goes out when the output is OFF)
Adjusting dial
Method of adjusting
Method I
Method II
Connect voltmeter to terminal 1 and 8
Shield Output 1
65 43
78 12
Output 2
+
-
V
PE-LA M0
1V
Position the standard size target to the position at a point 1/5th of the rated operating distance and turn the 1V adjusting dial clockwise slowly (to increase the output voltage) or counterclockwise so that the output voltage is 1V.
Position the standard size target at a point 1/5th of the rated operating distance and turn the 1V adjusting dial counterclockwise so that the SPAN indicator goes out, and then turn it clockwise slowly until the SPAN indicator lamp lights up.
5V
Position the standard size target to the position at the rated operating distance and turn the 5V adjusting dial clockwise slowly (to increase the output voltage) or counterclockwise so that the output voltage is 5V.
Position the standard size target to the position at the rated operating distance and turn the 5V adjusting dial clockwise slowly so that the SPAN indicator goes out, and then turn it counterclockwise until the SPAN indicator lamp lights up.
Adjustment of sensitivity
Position of target
Adjusting dial
S
SPAN indicator (Green)
Lights up when the linear output voltage is within the range from 1 to 5 Volts.
05/42
Method of adjusting
Position the standard size target in position and turn the detecting distance adjusting dial clockwise slowly until the operation indicator lights up. Move the standard size target so as to check that it operates at the specified position.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 46
Proximity Switches

PE2-C

Inductive proximity switches– Cylindrical type, PE2-C
The lineup of PE2-C series proximity switches has been augmented by the addition DC 3-wire system switches with NPN and PNP transistor outputs and 2­wire system switches usable for both AC and DC applications.
These new switches are characterized by:
• A stable operating indicator composed of a two-color (red and green) LED that enables easy and reliable setting of detection range
• Smaller dimensions and longer detecting distance due to incorporation of new IC
• Four ways to configure DC 2-wire systems, DC 3-wire systems (which provide NPN and PNP transistor outputs) and two-wire systems usable for both AC and DC applications. This wide choice of configurations makes it possible to choose appropriate switch for the circuit.
The DC 2-wire system
• Reduces wiring cost and labor
• Can be connected to such high impedance load as small relays, PLC, and NC equipment without risk of reset failure due to leakage currents of not exceeding 0.8mA and a residual voltage of 3V.
• Consumes very little current and places no burden on the power supply serving PLC. Make a power supply for the sensor unnecessary.
• Enables easy connection on site to load equipment having sink- and source-current input specifications.
• Has protective circuit to protect against short-circuit, reverse polarity, and surges.
The DC 3-wire system:
• Available in 16 types of units, shielded or unshielded, of varying diameter, and providing two types of output
• Also available with PNP output transistors for European machine tool applications.
PE2-C
AF91-505
• Has the same external dimensions as the PE1 series which is not equipped with stable operating indicator.
The 2-wire system switch usable for both AC and DC applications:
• Can be operated from sources from 20 to 250V DC and 40 to 250V AC.
• Reduces wiring cost and labor.
• Is unpolarized, eliminating hazard of reverse polarity connection.
05
Specifications
Description Operating system Operating Target External Response Supply Output Type Ordering
Shielded DC supply/2-wire, 2 8×8×1 M8 1500 3 to PE2-CSN2S PE2S02-S
Metal
Non­shielded
Metal
current output 3 12×12×1 M12 1000 100mA PE2-CS3S PE2S03-S
DC supply/3-wire, 2 8×8×1 M8 1500 200mA PE2-CS2D PE2S02-D NPN transistor 3 12×12×1 M12 1000 max. PE2-CS3D PE2S03-D output 7 18×18×1 M18 500 PE2-CS7D PE2S07-D
DC supply/3-wire, 2 8×8×1 M8 1500 200mA PE2-CS2Q PE2S02-Q PNP transistor 3 12×12×1 M12 1000 max. PE2-CS3Q PE2S03-Q output 7 18×18×1 M18 500 PE2-CS7Q PE2S07-Q
AC/DC supply/2-wire, 3 12×12×1 M12 1000 (DC) PE2-CS3W PE2S03-W thyristor output 25 (AC)
DC supply/2-wire, 4 20×20×1 M8 1000 3 to PE2-C4S PE2C04-S current output 8 30×30×1 M12 800 100mA PE2-C8S PE2C08-S
DC supply/3-wire, 4 20×20×1 M8 1000 200mA PE2-C4D PE2C04-D NPN transistor 8 30×30×1 M12 800 max. PE2-C8D PE2C08-D output 14 30×30×1 M18 400 PE2-C14D PE2C14-D
DC supply/3-wire, 4 20×20×1 M8 1000 200mA PE2-C4Q PE2C04-Q PNP transistor 8 30×30×1 M12 800 max. PE2-C8Q PE2C08-Q output 14 30×30×1 M18 400 PE2-C14Q PE2C14-Q
distance size (mm) diameter frequency voltage code (mm) (iron) (Hz)
12/24V DC
7 18×18×1 M18 500 PE2-CS7S PE2S07-S 10 30×30×1 M30 400 1NO PE2-CS10S PE2S10-S
10 30×30×1 M30 400 1NO PE2-CS10D PE2S10-D
10 30×30×1 M30 400 1NO PE2-CS10Q PE2S10-Q
7 18×18×1 M18 500 (DC) PE2-CS7W PE2S07-W
25 (AC)
10 30×30×1 M30 400 (DC) PE2-CS10W PE2S10-W
25 (AC)
14 30×30×1 M18 400 PE2-C14S PE2C14-S 24 60×60×1 M30 100 1NO PE2-C24S PE2C20-S
24 60×60×1 M30 100 1NO PE2-C24D PE2C24-D
24 60×60×1 M30 100 1NO PE2-C24Q PE2C24-Q
Operating voltage range 10 to 30V DC
24/48/100/200V DC 48/100/200V AC
Operating voltage range 20 to 250V DC 40 to 250V AC
12/24V DC Operating
voltage range 10 to 30V DC
5 to 100mA
1NO
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/43
Page 47
Proximity Switches
PE2-C
Specifications
Type PE2-C S PE2-CD PE2-CQ PE2-CW
Output Tranisistor output NPN transistor, PNP transistor, Thyristor output
Ambient temperature –25 to 80°C (no icing) Differential distance Max. ±10% of operating distance Variation due to Max. ±10% of operating distance at 20°C within a temperature range of –25 to 70°C
temperature fluctuation Variation due to Max. ±2% of operating distance at rated voltage when operated within ±15% of power supply voltage
voltage fluctuation Current consumption 25mA max. (at 24V DC) — Leakage current 0.8mA max. (at 24V DC) 0.8mA max. (at 24V DC),
Residual voltage 3V max. (at 100mA) 1.5V max. (at 24V DC, 200mA) 6V max. (DC), 10V max. (AC) Dielectric strength 1000V AC, 1 minute Insulation resistance 50M or more (500V DC megger) Degree of protection IP67 (IEC Standards) Vibration 10–55Hz, 1.5mm double amplitude (in X, Y, Z direction respectively for 2 hours) Shock 500m/s Circuit protection Short-circuit, reverse polarity, surge voltage Surge voltage
(DC supply/2-wire) (DC supply/3-wire) (AC/DC supply/2-wire)
open collector open collector output output
1.3mA max. (at 240V AC)
2
Response curve for iron (Typical)
PE2-CS(N)2 PE2-CS3 PE2-CS7 PE2-CS10W PE2-C4 PE2-C8 PE2-C14 PE2-C24
X
Y
1
2
0
3123
Y(mm) 4
3
2
1
PE2-C4 Target 20×20×1mm Iron
PE2-CS(N)2 Target 8×8×1mm Iron
X(mm)
X Y(mm)
Y
6246
8
6
4
2
2
4
0
PE2-C8 Target 30×30×1mm Iron
PE2-CS3 Target 12×12×1mm Iron
X(mm)
X
Y
Y(mm) 15
PE2-C14 Target 30×30×1mm
10
Iron
0
5 10 5510
PE2-CS7 Target 18×18×1mm Iron
X(mm)
X
Y
Accessories (optional)
Mounting bracket
A
B
C
D
Type A B C D Screw Used with (Ordering code) (mm) (mm) (mm) (mm)
PX1-P8 18 10 18 28 M4×20 PE2-CS(N)2 (PE1Z0037) PE2-C4
PX1-P12 24 12.5 20 37 M4×25 PE2-CS3 (PE1Z0033) PE2-C8
PX1-P18 32 17 30 47 M5×32 PE2-CS7 (PE1Z0034) PE2-C14
PX1-P30 45 17 50 60 M5×50 PE2-CS10W (PE1Z0035) PE2-C24
Sensor surface cover
KK02-301A
Type A B C Used with (Ordering code) (mm) (mm) (mm)
PX1-C12S
(PE1Z0030)
PX1-C18S
(PE1Z0031)
PX1-C30S
(PE1Z0032)
A
φ
15 5 0.6 PE2-CS3
φ
22.5 8 1.1 PE2-CS7
φ
35 12 1.6 PE2-CS10W
Y(mm)
30
25
20
15
10
5
B C
PE2-C24 Target 60×60×1mm Iron
PE2-CS10W Target 30×30×1mm Iron
201001020
X(mm)
05/44
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 48
Proximity Switches
Leakage current characteristics■ Residual voltage characteristics
PE2-CSS, CS, 12V DC PE2-CSS, CS, 24V DC PE2-CSS, CS
12
10
8
Load voltage (V)
6
4
2
Residual load voltage
Residual output voltage
10
20 30 505
ON
V
A
OFF
Load current (mA)
12V DC
100
24
20
16
Load voltage (V)
12
8
4
5
Residual output voltage
ON
V
A
Residual load voltage
10 50
OFF
30
20
Load current (mA)
24V DC
100
1.0
Leakage current (mA)
0.5
0
Prox. switch (OFF)
10 20
PE2-C
mA
DC
V
Supply voltage (V)
PE2-CSW, 24V DC
24
20
16
Load voltage (V)
12
8
4
Residual output voltage
Residual load voltage
10
ON
V
A
OFF
30 5020
Load current (mA)
PE2-CSW, 200V AC
200
160
120
Load voltage (V)
80
40
5 100
Residual output voltage
Residual load voltage
10 20
ON
V
A
OFF
30
Load current (mA)
PE2-CSW, 100V AC PE2-CSW
Residual output voltage
Residual load voltage
10 20
ON
V
A
OFF
50
30
Load current (mA)
100V AC
100
Prox. switch
1.0
Leakage current (mA)
0.5
0
(OFF)
Prox. switch (OFF)
50
100
mA
V
mA
V
200
150
Supply voltage (V)
05
AC
AC
DC
DC
24V DC
100
80
Load voltage (V)
60
40
20
1005
5
Wiring diagrams
DC supply/2-wire system
PE-CS
Brown
Load
10 - 30V DC
200V AC
Indicator
Proximity switch
Blue
Load
50
DC supply/3-wire system
PE2-CP PNP output
Indicator
Proximity switch
Brown
Load
Blue
10 - 30V DC
DC supply/3-wire system
PE2-CN NPN output
Brown
Indicator
Proximity switch
Load
Black
Blue
AC/DC supply/2-wire system
PE2-CW
Brown
Indicator
Proximity switch
Load
Blue
Load
10 - 30V DC
20 - 250V DC or 40 - 250V AC
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/45
Page 49
Proximity Switches
PE2-C
Dimensions, mm
PE2-CSN2S, PE2-CS2 PE2-C4 PE2-CS3W
Toothed
4
27
lock washer
37
P=1
M8
13
Indicator
ø3
IV cable 0.14mm
2000
P=1
M8
2
13
Mass: 40g Mass: 40g
PE2-CS3 PE2-C8 PE2-CS7W
Toothed
P=1
M12
4
lock washer
Indicator
P=1
ø4
M12
Toothed
4
lock washer
5
27
37
4
Toothed lock washer
Indicator
IV cable
2000
Indicator
ø4
ø3
0.14mm
2
17
M12 P=1
4
45
58
Toothed lock washer
Indicator
ø4
IV cable 0.3mm
2000
2
Mass: 100g
4
Wave
Indicator
washer
ø6
IV cable
17
30
43
0.3mm2 for 2-wire
0.2mm2 for 3-wire
2000
17
7
30
43
IV cable
0.3mm2 for 2-wire
0.2mm2 for 3-wire
2000
M18 P=1
24
Mass: 70g Mass: 70g
PE2-CS7 PE2-C14 PE2-CS10W
P=1
M18
24
4
Wave
Indicator
washer
37
53
ø6
IV cable
0.5mm
2000
2
M18 P=1
24
4
Wave
Indicator
washer
10
37
53
ø6
IV cable
0.5mm
2000
2
M30 P=1.5
36
Mass: 160g Mass: 160g
PE2-C24 PE2-CS3S
5
Wave washer
Indicator
ø6
M30 P=1.5
36
15
42
58
IV cable
0.5mm
2000
2
17
M12 P=1
4
30
Toothed lock washer
Indicator
57
Mass: 280g Mass: 30g
M30 P=1.5
42
5
67
Wave washer
Indicator
39
ø14
PE2-CS7S PE2-CS10S Plug for connector
4
Wave washer
Indicator
M18 P=1
24
37
62
36
Mass: 60g Mass: 170g
ø6.7
48
64
Wave
5
washer
52
68
2m : PX2-CN2SX2 5m : PX2-CN2SX5
IV cable 0.5mm
Mass: 170g
Indicator
IV cable
0.5mm
Mass: 340g
IV cable 0.5mm
2
2000
ø6
2
2000
2
Note: A mark band is attached when the oscillation frequency differs from that of standard products.
Mutual interference:
Be sure to space two switches at a distance greater than that shown in the table at right to prevent mutual interference.
Type A (mm) B (mm) PE2-CS(N)220 15
PE2-CS3 30 (15) 20 (12) PE2-CS7 50 (25) 35 (18) PE2-CS10W 100 (50) 70 (35) PE2-C4 80 60 PE2-C8 120 (60) 80 (40)
A
B
PE2-C14 200 (100) 120 (60) PE2-C24 350 (175) 250 (125)
Note: The values in parentheses are applicable
when using two switches with oscillation frequencies different from each other.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
05/46
Ordering information
Specify the following:
1. Type number or ordering code
Information subject to change without notice
Page 50
Proximity Switches

PE-X3D

Inductive proximity switches–Flat type, PE-X3D
Easy-to-mount thin inductive type proximity switches
Operating system:
DC supply/3-wire system
Operating distance: 3mm
Specifications
Type (Ordering code) Operating system Output Operating distance Target size Differential distance Power supply voltage Operating voltage range Current consumption Switching capacity Residual voltage Response frequency Ambient temperature Humidity Circuit protection Variation due to temperature
fluctuation Variation due to voltage
fluctuation Dielectric strength Insulation resistance Degree of protection Vibration Shock
Response curve for iron
Target 12 x 12 x 1 mm, Iron
Y (mm)
3
X
Y
2
1
1234566543210
PE-X3D (PE1X03-D) DC supply/3-wire NPN transistor, current output, 1NO 3mm ±10% 12 × 12 × 1mm (iron) Max. ±10% of operating distance 12/24V DC 10 to 30V DC 15mA max. at 24V DC 100mA max.
1.5V max. at 24V DC 100mA 50Hz or more –25 to +70°C (no icing) 35 to 95% RH Surge voltage, reverse polarity Max. ±10% of operating distance at 20°C within temperature
range of –25 to +70°C Max. ±1% of operating distance at 12/24V DC when operated
within 85% to 115% of power supply voltage 1000V AC, 1 min. 50M (500V DC) IP66 (IEC Standard) 10–55Hz, 1.5mm double amplitude
2
500m/s
X (mm)
Features
• A mere 7mm height
• Only two screws are needed to affix each switch, eliminating the need for exclusive mounting brackets
• Incorporates a stable operating level indicator
• Equipped with surge suppression circuits and protection circuits against reverse polarity
Material of target–Operating
distance
3
2
1
Operating distance (mm)
10020
Length of one side of target (mm)
Fe
Stainless (SUS304)
Brass Al Cu
30
40
PE-X3D
AF92-374
Wiring diagram
Brown
Load
Proximity switch
Black
Blue
10-30V DC
Dimensions, mm
Indicator
IV cable
0.14mm
ø3
1000
2
Mass: 20g
Sensor
surface
5
137
1.5
13.5
0.5
30
ø3.2
2.5
10
ø6.4
2.5
Mutual interference
Be sure to space two switches at a distance greater than that shown in the figure below to prevent mutual interference.
50mm 50mm
Ordering information
Specify the following:
1.Type number or ordering code
05
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/47
Page 51
Proximity Switches
A
B

PE-G4D

Inductive proximity switches– Square type, PE-G4D
Operating system:
DC supply/3-wire system Supply voltage range: 10 to 30V DC Operating distance: 4mm
Specifications
Type (Ordering code) Operating system Output Operating distance Target size (iron) Differential distance Rated voltage Switching capacity Current consumption Residual voltage Response frequency Variation due to voltage
fluctuation Variation due to temperature
fluctuation Dielectric strength Insulation resistance Degree of protection Ambient temperature Humidity Vibration Shock
Wiring diagrams
Proximity switch
PE-G4D (PE1G04-D)
DC supply/3-wire 1NO 4mm ±10% 20×20×1mm Max. ±10% of operating distance 12/24V DC (10 to 30V DC) 50mA max. 15mA max. at 24V DC
1.5V max. at 50mA 200Hz Max. ±1% of operating distance at 12/24V DC when
operated within 10 to 30V DC Max. ±10% of operating distance at 20°C within
temperature range of –25 to +70°C 2000V AC, 1min. 50M or more (500V DC) IP67 (IEC) –25 to +70°C (no icing) 35 to 95% RH 10–55Hz, 1.5mm double amplitude 500m/s
Brown
Load
Black
Blue
Features
• Degree of protection meets the requirements of IEC IP67, thus permitting operations in unfavorable environment.
• Only two screws are needed to affix each switch, eliminating the need for exclusive mounting brackets.
• Incorporates surge suppression circuits and protection circuits against reverse polarity and short-circuits.
2
Dimensions, mm
24.5
Indicator 2-ø3.3
10-30V DC
17
17
PE-G4D
AF90-849
Response curve for iron
Target 20 x 20 x 1mm, Iron
Y (mm)
4
X
Y
50 5
3
2
1
X (mm)
Mutual interference
Be sure to space two switches at a distance greater than that shown in the figure below to prevent mutual interference.
Type PE-G4D
A (mm) 60
B (mm) 60
Ordering information
Specify the following:
1.Type number or ordering code
28
2000
10.5 ø4
Mass: 40g
05/48
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 52
Magnetically operated reed
X
Y
Y(mm)
160
120
80
40
OFF ON
04040 8080 120120160
X(mm) -X(mm)
PM–2S +PM–10M PM–2SH+PM–10MH
M
Sw
switches, PM Standard type
Operating distance: Maximum 35, 70,
120mm
Reed switch: 1NO, 2 Amps
Features
• Power source not required
• Comprises sensing magnetic element and reed switch
• Resin molded construction
• Water- and dust-tight, shock-resistant
• Breaking capacity: 0.5Amps at 220V AC
• Operating distance is longer than oscillating type.
• Economically priced
• 1 meter color-coded lead wires
Ordering information
Specify the following:
1.Type number or ordering code
(Specify reed switch and magnet separately.)
Response curves, typical
Short axis M: Magnet Sw: Reed switch
M
Y
Sw
X
PM–2S +PM–2M PM–2SH+PM–2MH
Y(mm)
40
30
20
10
OFF ON
Proximity Switches
Magnetically operated reed switches
X-806X-806
PM-4M PM-10M PM-2S
Specifications
Magnet (standard type)
Type PM-2M PM-4M PM-10M Operating distance 25 – 40mm 50 – 70mm 80 – 120mm
Differential 5 – 15mm 5 – 20mm 15 – 40mm Ambient temperature –10° to +65°C –10° to +65°C –10° to +65°C
Magnet (High temperature using type)
Type PM-2MH PM-4MH PM-10MH Operating distance 25 – 40mm 40 – 70mm 100 – 140mm
Differential 5 – 15mm 5 – 20mm 15 – 40mm Ambient temperature –20° to +130°C –20° to +130°C –20° to +130°C
PM2S, PM-2SH read switches
Rated operating voltage: 220V AC, DC (Max.) Rated operating current: 0.5A (Max.) Make and break capacity: 50W DC, 50VA AC (Max.)
Mechanical: durability 100 million operations Electrical: 2 million operations at 200V AC 0.125A
Insulation resistance: Over 100M at 500V DC Dielectric strength: 700V AC rms. 1 minute (Contact to contact) Ambient temperature: –10 to +65°C (For 130°C use is also available) 1 meter lead wires are normally provided.
M
Y
Sw
X
1.4 million operations at 100V AC 0.25A
PM–2S +PM–4M PM–2SH–PM–4MH
Y(mm)
80
60
40
20
OFF ON
PM
X-806
05
X(mm) -X(mm)
01010 2020 303040
X(mm) -X(mm)
02020 4040 606080
PM-2S PM-2S PM-2S
Dimensions, mm
PM-2S Mass: 210g PM-2SH
81 95
High temperature type
ø8.2
IV Cable
0.75mm
1000
ø10
ø6
Standard type
35
21
20
Notes: • Reed switch and magnetic element are mounted on anti-magnetic material. The operating distance will be decreased when mounted on magnetized
materials.
• Both reed switch and magnetic element cannot be used in over 5-gauss magnetic fields.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
PM-2M Mass: 170g PM-2MH
ø4.7
2
R2.5
PM-4M Mass: 440g PM-4MH
5
35
19
50 60
40
25
19
110 125
95
PM-10M Mass: 1300g PM-10MH
6
39
19
25
19
170 186
146
7
42
21
50.5
20
05/49
Page 53
Proximity Switches
Magnetically operated reed switches - slot type PM1U
Magnetically operated reed switches–Slot type PM1U
Features
• Stable switch operation is ensured by inserting the object for detection 35mm into the switch slot. Ideal for detecting the position of a ferromagnetic-material plate passing in the switch slot.
• Magnetically operated switch using a sealed contact is never affected by electrical noise, ensuring highly reliable detection.
• The built-in permanent magnet enables switching of both AC and DC signals without using a power supply.
• Models with an output indicator are also available.
• Our advanced design assures superior environmental protection complying with IP67 (IEC).
Ordering information
Specify the following:
1. Type number (ordering code)

PM1U

KK02-304A
Specifications
Operating Detecting Hysteresis Contact Output Type Measurement conditions for an operating slot width distance* arrangement indicator (=Ordering code) position and hysteresis
25mm +4 ±6mm 10mm (Max.) 1NO Not PM1U-25ALF
(ON: Detected) provided
Provided PM1U-25ALF2
0
X
–4 ±6mm 7mm (Max.) 1NC Not PM1U25BLF
(OFF: Detected)
provided
Provided PM1U-25BLF2
Note *: The detecting distance and hysteresis are defined in the standard detecting conditions shown above.
35
magnet
Permanent
(Object insertion length)
ZZ
Reference object for detection SPCC60(W)×100(H)×t1.6)
Reed switch
Type PM1U-25ALF PM1U-25ALF2 PM1U-25BLF PM1U-25BLF2 Output indicator Not provided Provided Not provided Povided Operating slot width 25mm Object insertion length 35mm (Min.) Rated operating voltage 220V AC, DC (Max.) Rated operating current 0.2A (Max.) Make and break current 0.2A (Max.) OFF ON response time 2ms (Max.) ON OFF response time 0.5ms (Max.) Life expectancy (Mechanical) 1×107 operations (Min.) Life expectancy (Electrical) 2×106 operations (Min.) Load: Miniature control relay HH54P 220V AC/7mA
3×106 operations (Min.) Load: Miniature control relay HH54P 100V AC/14mA 2×106 operations (Min.) Load: Resistance (24V DC/0.2A)
1×107 operations (Min.) Load: Resistance (12V DC/0.2A) Ambient temperature –10 to +65°C Humidity 45 to 95%HR Vibration resistance 10 to 55Hz, 1.5mm peak-to peak amplitude, 2-hour for each of X, Y, and Z axes Shock resistance 300m/s2, three-time for each of X, Y, and Z axis Output resistance at ON 6 (Max.) 6 (Max.) – Switch residual voltage at ON 4V (Max.) 4V (Max.) Insulation resistance 100M (Min.) Degree of protection IP67 (IEC standard) Maximum signal cable length 300m
Note: The LED indicator becomes dark when the load current is 10mA or less. (Switches with an output indicator) 1 meter lead wire is provided.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
05/50
Information subject to change without notice
Detecting distance Object moving direction
Hysteresis Reset distance
Object moving direction
Y
0
Page 54
Object detection area (Examples)
40 25
38
Counter-bore for M6 nut (7mm-deep)
6mm-dia., 0.5mm
2
PVC pair cable (1m)
Output indicator
29
67
3
52
7
46
ø6.2
30
(60)
Embedded metal with inside threads for M6 screw (10mm-deep)
PM1U-25A PM1U-25B
Object to be detected
-5
-10
10
0
-5
SPCC 100×60×t1.6
1055
Y 60
Detecting position Reset position
X(mm)
Y(mm)
-10
X
0
10
20
30
40
50
Z(mm)
Object to be detected
SPCC 100×60×t1.6
Y(mm)
1050-5-10
Y 60
Detecting position Reset position
-10
Y(mm)
X
10
-5
-5
-10
0
Object to be detected
SPCC 100×60×t1.6
Detecting position Reset position
1055
Y 60
X(mm)
Proximity Switches
PM1U
Object to be detected
SPCC 100×60×t1.6
0
10
20
30
40
50
1050-5-10
Z(mm)
Y 60
Y(mm)
Detecting position Reset position
35
Note: The X - Y characteristics are
symmetrical to the X axis.
Wiring diagrams
100
Z
Note: The Y - Z characteristics are
symmetrical to the Z axis.
100
35
Note: The X - Y characteristics are
symmetrical to the X axis.
100
Z
Note: The Y - Z characteristics are
symmetrical to the Z axis.
100
05
Switch with no output indicators Switch with an output indicator
Brown
Load
Reed switch
Power supply
Blue
LED (Red)
Brown
Load
Reed switch
Power supply
+
Blue
Note: When using a DC power supply, connect the brown
terminal to (+) and blue terminal to (0V). Otherwise, the indicator will not go on.
Operation chart Dimensions, mm
PM1U-25A
Object to be detected
Reed switch
LED output indicator
PM1U-25B
Object to be detected
Reed switch
LED output indicator
Present
Not present
OFF
Not lit
Present
Not present
OFF
Not lit
ON
ON
Lit
Lit
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/51
Page 55
Proximity Switches
AC, DC
Load
AES
502L
Magnetically operated reed switches AES
Magnetically operated reed switches AES
Small size
Operating distance: Max. 20, 27mm Reed switch: 1NO
Rated thermal current: 2.5A (AES402)
2.5A (AES502)
AEQ010-1A
Features
• Power source is not required. AES402 is small size, soldering terminal. AES502 is provided with lead wire.
• Epoxy resin molded, shock-resistant.
• Make and break capacity: Max. 50VA, 50W (AES402) Max. 50VA, 50W (AES502)
• Operating voltage: Max. 220V AC, DC (AES402) Max. 220V AC, DC (AES502)
Ordering information
Specify the following:
1. Type number or ordering code
Specifications
Type Contact
Ordering code Contact PM2B PM2D
Contact 1NO Operating distance 14–20mm 20–27mm
Differential 1–12mm 1–14mm Repeat accuracy 0.5mm or less Ambient temperature –20°C to +80°C Dielectric strength
Between open contacts 700V AC, 1 min. 350V AC, 1 min. Terminal to ground 1500V AC, 1 min. 1500V AC, 1 min.
Insulation resistance 100M or more 100M or more
Life Mechanical 10 million operations expectancy
AES402B-1A
FA-1446
Magnet
AES402B-1A AEQ010-1A
AES502L-3A AEQ020-1T
Magnet PM34 PM35
at 500V DC at 500V DC
Electrical 2 million 2 million
operations at operations at 100V AC 3.3VA 100V AC 3.3VA
AEQ020-1T
SB-131
AES502L-3A
Response curves
Short axis
Contact: AES402B-1A Magnet AEQ010-1A
AEQ010
X
Y
AES402
35
Contact: AES502L-3A Magnet AEQ020-1T
X
Y
AES502L
05/52
25 20 15 10 5 530
AEQ020
Dimensions, mm
AES402B-1A AEQ010-1A
14.2
20.6
4.5
4.1
Y [mm]
30
OFF
OFF
ON
ON
20
15
10
5
0
Y
[mm]
40
30
20
10
0101020304050 3020
353025201510
X [mm]
40
50
X
[mm]
25.4
49.2
AES502L-3A
2-ø5.5
Wiring
AES402B-1A AES502L-3A
ø4.1
17.5
2
IV cable
0.5mm
ø7.2
23
52 62
14
15
9
Load
AC, DC
33
25.4
40.6
AEQ020-1T
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
3.2
6
15.4
12.6
6
5.2
7
17
42 30
17
52
9
Mass: AES402B-1A:20g AES502L-3A: 85g AEQ010-1A: 20g AEQ020-1T: 25g
Notes:
• The operating distance will be decreased when mounted on ferromagnetic material such as iron.
• Both reed switch and magnetic elements can not be used in over 5-Gauss magnetic fields.
Information subject to change without notice
Page 56
Proximity Switches
Magnetically operated reed switches
AER
Magnetically operated reed switches AER
Operating distance: 4.0–5.5mm (at 1NO) Reed switch: 1NO or 1NC
Construction
Silicon tube
Permanent magnet
Reed switch
Rated thermal current: 2.5A
Features
• Sensing magnetic element and reed switch element are integrated in an epoxy molded housing.
• Power source is not required.
• Travelling direction of the metal object is not limited.
• Make and break capacity:
Case
Packing
Wires
Epoxy resin molded
Max. 50VA AC, 50W DC
• Operating voltage: Max. 220V AC, DC
• Water- and dust-tight
Notes: • The operating distance will be decreased
when mounted on ferromagnetic material such as iron.
• This switch cannot be used in over 5-Gauss magnetic fields.
• Keep a distance of over 100mm from other limit switches.
Specifications
Type (Ordering code) AER201L-1A (PM1A) AER211L-1A (PM1B) Contact arrangement 1NO 1NC Rated voltage AC, DC 220 max. 220V max. Rated thermal current 2.5A 2.5A Make and break current Max. 0.5A AC, DC Max. 0.5A AC, DC Operating distance 4.0–5.5mm 3.5–5.0mm Differential 1–5.5mm 1–5.5mm Repeat accuracy Less than 0.5mm Less than 0.5mm Ambient temperature –20° to +80°C –20° to +80°C Dielectric strength 350V AC rms. 1 minute (Between open contacts)
1500V AC rms. 1 minute (Terminal to ground) Insulation resistance Over 100M at 500V DC Life expectancy Mechanical 10 million operations
Electrical 2 million operations at 100V AC 3.3VA (Inductive)
2 million operations at 100V DC 1.6W (Inductive)
10 million operations at 12V DC 6W (Resistive)
Notes: • 1 meter lead wires are normally provided.
• The standard detected object is iron plate of 50 × 50 × 2 (mm). If the object is smaller, the operating distance is reduced.
AER201L-1A
Response curves
AER20 Short axis
AER20 Long axis
AER21 Short axis
Y
Y
Y
Target 2 × 50 × 50 mm Iron
X
Target 2 × 50 × 50 mm Iron
X
Target 2 × 50 × 50 mm Iron
X
FA1445
05
Wiring
Load
AC, DC
Dimensions, mm
6.5
Ordering information
Specify the following:
1.Type number or ordering code
1000
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
48.6 41 22
24
31
3.5
ø7.2
2
0.5mm
Mass: 100g
AER21 Long axis
Y
Target 2 × 50 × 50 mm Iron
X
05/53
Page 57

Photoelectric Switches

General information

Selection guide
Basic type Photo
Description
Detecting method
Operation mode Special function
PH1C
Highly compact photoelectric switch with dimensions of
10.8x31x20mm. Energy saving design with long-distance detection and a built-in amplifier. Meets CE Mark requirements.
Transmission type Retroreflective type Diffuse reflection type
Dark-ON/Light-ON selectable –
XX03-013A
Supply voltage
Output configuration
Output (switching capacity)
Detectable object (material)
Detecting distance
Response time
Ambient temperature
Degree of protection Page
12 to 24VDC ± 10% (ripple ± 10% or less)
Detecting:
NPN transistor, open collector output
100mA max.
Transparent, opaque
1m, 3m, 4m, 10m
1ms
Operation: –25 to +55°C Storage: –40 to +70°C
IP67 (IEC)
05/56
Detecting method
Transmission type Refroreflective type Diffuse reflection type
Light source Receiver
Light source/ receiver
Reflector
Light source/ receiver
05/54
Object
Object Object
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 58
Photoelectric Switches
General information
Basic type Photo
Description
Detecting method
Operation mode Special function
Supply voltage
Output configuration
PH4C
XX03-002A KK02-303A
AC/DC dual supply voltage. Highly compact with dimensions of 18 x 50 x 50mm. Retroreflective type equipped with mirror surface rejeciton function
Transmission type Retroreflective type Diffuse reflection type
Dark-ON or Light-ON –
24 to 240V AC±10% 12 to 240V DC±10%
Relay output
(ripple ±10% or less)
PH8AU
Slot-type photoelectric switches ideal for conveyor applications, such as elevators and multi-level parking lifts. Same mounting method as our slot-type magnetically operated reed switches (type PM1U).
Slot type
Dark-ON or Light-ON –
10 to 30V DC
NPN transistor, open collector output
05
Output (switching capacity)
Detectable object (material)
Detecting distance
Response time
Ambient temperature
Degree of protection Page
Operation mode
Dark-ON (operates when light is interrupted)
Light-ON (operates when light is incident)
3A max. (250V AC res. load) 10mA max. (5V DC)
Transparent, opaque
30cm, 2.5m, 3.5m, 4m, 5m
30ms max.
Operation: –25 to +55°C Storage: –30 to +70°C
IP64 (IEC)
05/61
Transmission type Retroreflective type Diffuse reflection type Slot type
Opaque
30mm
1ms or less
Operation: -25 to +55°C Storage: -30 to +70°C
IP66 (IEC)
05/65
without object
with object
without object
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/55
Page 59
Photoelectric Switches

PH1C

Photoelectric switches with built-in amplifier PH1C
Features
• Highly compact with dimensions of 10.8 x 31 x 20mm
• Energy-saving design
• Covers a wide range of detection with distances of 10m (transmission type), 3 or 4m (retroreflective type), or 1m (diffuse reflection type)
• Retroreflective type equipped with mirror surface rejection function
• High-speed response time of 1ms
• Light-ON/Dark-ON selectable with operation mode switch
• Equipped with various protective functions
• High degree of protection of IP67 (IEC) enables use even in environments where exposure to water is possible.
• Improved alignment (±2.5˚) of optical and mechanical axes simplifies adjustment (transmission type, retroreflective type)
• Environment-friendly lead-free solder used
• Meets CE Mark requirements.
XX03-014A,15A
Transmission type PH1CT
XX03-013A XX03-007A
Retroreflective type PH1CR
Diffuse reflection type PH1CD
Reflector PH1X
Types
Detecting method Detecting Light Output Output
distance emitting operation
element mode
Transmission type 10m Red LED NPN Dark-ON /
Light source Receiver
Object
Retroreflective type 0.1 to 3m Red LED (with mirror surface rejection ) (using PH1X-R1)
Light source/receiver
Reflector PH1X
Diffuse reflection type 1m Infrared
Light source/receiver
Object
Object
0.1 to 4m (using PH1X-R1S)
LED
transistor, open
collector output
Light-ON selectable
Type
PH1CT-M1DC PH1CT-M1DCSN PH1CT-M1DCST PH1CT-M1DCR PH1CT-M1DCRLN PH1CT-M1DCT PH1CT-M1DCTLN PH1CR-3MDC PH1CR-3MDCLN
PH1CD-1MDC PH1CD-1MDCLL
Supplied item
Cable length
Light source and 2m receiver 5m
10m
Receiver 2m
5m
Light source 2m
5m Light source/ 2m receiver 5m
Light source/ 2m
receiver 3m
05/56
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 60
Photoelectric Switches
PH1C
Ratings and specifications
Detection method Transmission type Retroreflective type (with mirror Diffuse reflection type
surface rejection) Type PH1CT-M1DC PH1CR-3MDC PH1CD-1MDC Light emitting element Red LED Infrared LED Supply voltage 12 to 24V DC ±10% (ripple ±10% or less) Current consumption Light source: 15mA, Receiver: 20mA 30mA max. Detecting distance 10m 0.1 to 3m (using PH1X-R1) 1m (white mat paper 30 x 30cm)
0.1 to 4m (using PH1X-R1S) Detectable target Opaque 12mm dia. min. Opaque 75mm dia. min. Transparent or opaque Directional angle Light source and receiver: 3 to 15° Light source/receiver: 2 to 10°,–
each Reflector: 30° Differential Max. Detecting output NPN transistor, open collector output
Load current: 100mA max. (26.4V DC)
Residual voltage: 1V DC max. at load current less than 10mA
2V DC max. at load current of 10 to 100mA
Output operation mode Dark-ON / Light-ON selectable Response time 1ms max. (operation/reset) Indicator Operation indicator Orange LED (Light source: power Orange LED Orange LED
supply indicator) Stability level Green LED (Receiver) Green LED Green LED indicator
Connection Attached cable (2m, 0.2mm
Sensitivity adjustment Dial Ambient operating illumination Incandescent lamp: 3000 lx max. (at receiving surface)
Sunlight: 10000 lx max. (at receiving surface) Ambient temperature Operating: –25 to +55˚C (no icing), storage: –40 to +70˚C Ambient humidity Operating: 35 to 85%RH (no condensation), storage: 35 to 95%RH Degree of protection IP67 (IEC) Protective function Reverse polarity (input), short-circuit Reverse polarity (input), short-circuit, reverse polarity (output) and
and reverse polarity (output) mutual interference Insulation resistance 20M (500V DC megger) Dielectric strength 1,000V AC for 1min Vibration 10 to 55Hz, 1.5mm double amplitude or 300m/s Shock 500m/s Material Casing Polybutylene terephthalate resin (PBT) Lens Polyarylate resin (PAR) Methacrylic resin (PMMA) Polyarylate resin (PAR)
Mass Approx. 120g Approx. 65g Approx. 65g
Accessory (option) Mounting bracket (PH1X-P1, PH1X-P2)
Note : Reflectors PH1X-R1 and R1S (for retroreflective type PH1CR use) are sold separately.
2
(3 times for each X, Y, Z direction)
2
)
2
(2 hours for each X, Y, Z direction)
20% of detecting distance
05
Type number nomenclature
PH 1C T-M1 D C
Basic type
PH : Photoelectric switch
Series
1C : With built-in amplifier
Detecting method
T : Transmission type R : Retroreflective type D : Diffuse reflection type
Detecting distance
1M : 1m 3M : 3m M1 : 10m
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Supplied item
Blank : Light source and receiver,
(PH1CR, PH1CD)
T : Light source
R : Receiver
Output operatoin mode
C : Dark-ON, Light-ON selectable
Output
D : NPN transistor, open
collector output
Cable length
Blank : 2m
LL : 3m LN : 5m SN : 5m (PH1CT-M1DC) ST : 10m (PH1CT-M1DC)
Ordering information
Specify the following
1. Type number
05/57
Page 61
Photoelectric Switches
PH1C
Dimensions, mm PH1CT-M1DC
Light source Receiver
PH1CR-3MDC, PH1CD-1MDC
Light source/receiver
20
8
10.4
10.8
Power supply indicator (Orange)
Optical axis
11
18
7.2
Lens
2.1
31
15.5
Cable: 2m, 0.2mm
25.4
2-M3
17
Optical axis
18
2
Dimensions, mm (sold separately)
Reflector
PH1X-R1, PH1X-R1S
40.3
2–ø3.5
59.9
Reflection surface: Methacrylic resin (PMMA) Reverse side: Acrylonitrile butadiene styrene resin (ABS)
34
7
Reflection
52
surface
7.5
8
1.6
2.7
Operation indicator
(Orange)
10.4
10.8
Stability level indicator (Green)
7.2
Lens
11
Sensitivity adjuster
2.1
31
15.5
Mounting bracket
PH1X-P1
Stainless
16.2
8.7
9
6
18
3.4
6
20
12.5
8.8
3.2
Operation mode changeover switch
17
25.4
2-M3
Cable: 2m, 0.2mm
ø
3.2
3.5
°
20
14
31.2
2
23.2
R25.4
20
12.5
Operation mode changeover switch
2-M3
10.8
10.4
14.1
8.7
16.2
8.8
4.3
17
2
2–M3
7.2 18 9
4.3
Receiving section
Optical axis
4
18
4
Light source section
1.2
20
23.2
36
3.2
36
31.2
Operation indicator
(Orange)
10.4
10.8
Stability level indicator (Green)
2–lens (ø7)
2.1
31
15.5
1.2
PH1CD-3MDC with mounting bracket
3
2.1
Optical axis
31
25.4
35.3
3.2
Sensitivity adjuster
25.4
Cable: 2m, 0.2mm
Slit
PH1X-SP, PH1X-S1, PH1X-S2
Stainless Stainless
A
0.5 : PH1X-SP
1.0 : PH1X-S1
2.0 : PH1X-S2
A
3.4
15.5
4.5
0.2
32.2
10.4
10
PH1X-P2
R20
14°
2–ø3.2
3.2
Detection characteristics using PH1X slit
Photoelective switch Slit width (mm) Detecting distance (m) Minimum detectable target (mm dia.)
PH1CT-M1DC
0.5×10 1×10 2×10
0.7 1.5 3.5
0.2 0.5 0.8
05/58
3.4
29
16
R25.4
10°
1.2
3.4
64.5
3.5 39
29
PH1CD-3MDC with
7
13.7
8.8
13.7
20
mounting bracket
12.4
3
Optical axis
31 2.1
38.3
10.8
10.4
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
2-M3
25.410.1
22.8
1.2
Page 62
Photoelectric Switches
Characteristic curve, typical
Receiver output-Distance
PH1CT-M1DC PH1CR-3MDC + Reflector PH1CD-1MDC
100
70 50
30
10
7 5
3
Receiver output allowance
(times)
1
0.7
0.5
0.3
Operating level
0.1 010203040506070
Distance (m)
100
70 50
30
10
7 5
3
Receiver output allowance
(times)
1
0.7
0.5
0.3
Operating level
0.1 0246810
PH1X-R1
PH1X-R1S
Distance (m)
100
Detecting target: White mat paper 30×30cm
70 50
30
10
7 5
3
Receiver output allowance
(times)
1
0.7
0.5
0.3
Operating level
0.1 0 0.5 1 1.5 2.523
PH1C
Distance (m)
Setting range of light source and receiver head
PH1CT-M1DC
600
400
Distance Y (mm)
200
0
200
400
600
10 20 30 40 50
Y
X
Distance X (m)
Size of detecting target - Distance
PH1CD-1MDC
4.5 d
4
d
3.5
Distance Y (m)
3
2.5
2
1.5
1
0.5
SUS (glossy)
White mat paper
Black carbon paper
35302520151050
Target size d (cm)
PH1CT-M1DC + Slit PH1CR-3MDC + Reflector
200
150
100
Distance Y (mm)
50
0
50
100
150
200
Operating range
PH1CD-1MDC
50 40
Black carbon paper
30 20
Distance Y (mm)
10
0 10 20 30
White mat paper
40 50
Y
X
1 2 3 4 56
PH1X-SP
PH1X-S2
0.5 1 1.5 2 2.5 3 3.5
PH1X-S1
Y
X
SUS (glossy)
Distance X (m)
Distance X (m)
200
150
100
Distance Y (mm)
50
0
2 4 6 810
50
100
150
200
PH1X-R1S
PH1X-R1
Wiring diagrams
PH1CT receiver, PH1CR, PH1CD
Operation indicator (Orange)
Stability level indicator (Green)
PH1CT light source
Power supply indicator
(Orange)
PH main circuit
PH main circuit
Y
X
Distance X (m)
12 to 24V DC
Brown
Load
Black
100mA or less
Blue
12 to 24V DC
Brown
Blue
05
0V
0V
Timing diagrams
"Light-ON" mode (switch: L side) "Dark-ON" mode (switch: D side)
Light is incident Light is interrupted
Operatiion indicator (Orange)
Output transistor
Load (Relay)
ON OFF
ON OFF
ON OFF
(Brown-Black)
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Light is incident Light is interrupted
Operatiion indicator (Orange)
Output transistor
Load (Relay)
ON OFF
ON OFF
ON OFF
(Brown-Black)
05/59
Page 63
Photoelectric Switches
PH1C
Indicator Operation indicator (Ope)
Lights when the switch is activated (output transistor ON) irrespective of Light-ON, Dark-ON.
Stability level indicator (Stab)
Lights when the incident light or shaded light is good enough for stable level.
Status of incident light Indicator AllowanceStab Light-ON Dark-ON
Stable incident Stable shade
(green)
ON
Ope
(orange) ON
Operation level ×1.11
Unstable incident Unstable shade
OFF
ON
Operation level
Unstable shade Unstable incident
OFF
OFF
Operation level ×0.86
Stable shade
ON
OFFStable incident
Optical axis adjustment
Transmission type
Swinging the light source and receiver up and down and right and left when no objects exist, set and fix the light source and receiver to the center within the range where the operation indicator (orange) is lit or is turned off (Dark-ON). At the same time make sure that the stability level indicator (green) is lit.
Retroreflective type
Swinging the unit and reflector up and down and right and left when no objects exist, set and fix the unit and reflector to the center within the range where the operation indicator (orange) is lit or is turned off (Dark-ON). At the same time make sure that the stability level indicator (green) is lit.
Sensitivity adjustment
When carrying a normal detection, set the sensitivity adjuster at the maximum sensitivity value by turning it fully clockwise.Sensitivity adjustment is necessary for the following cases.
• Transmission type: To detect translucent or minute objects
• Reflection type: To detect objects with inadequate contrast
Carry out the sensitivity adjustment as follows. (When excessive power is added to the sensitivity adjuster, it might be damaged.)
Step State of detected object Operation indicator and
sensitivity adjuster
Transmission type Reflection type
1
2
3
Note: lit, not lit
Detected object
Background object
Light-ON Dark-ON
A
Min. Max.
B
Min. Max.
set
A
Min. Max.
B
A
Min. Max.
B
Min. Max.
set
A B
Min. Max.
Step
By turning the sensitivity adjuster, obtain point A and B at that the status of the operation indicator changes. Unless the status changed, two points at finishing turning the sensitivity adjuster will be point A or B.
An intermediate position between point A and B will be the optimum position.
05/60
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 64
Photoelectric switches with AC/DC input PH4C
Features
• Highly compact with dimensions of 18 x 50 x 50mm
• Accepts a wide range of supply voltage with AC/DC dual input
• Retroreflective type has a wider range of detecting distance.
3.5m for PH4CR-2HR, 5m for PH4CR-4MR (using a separately-sold reflector PH1X-R1S)
• Retroreflective type equipped with mirror surface rejection function
• Meets CE Mark requirements
Transmission type PH4CT
Diffuse reflection type PH4CD
XX03-003A XX03-002A
XX03-001A
Photoelectric Switches

PH4C

Retroreflective type PH4CR
XX03-007A
Reflector PH1X-R1S
Types
Detecting method Detecting Light Output Operation
distance emitting mode
element
Transmission type 5m Infrared Relay Light-ON
Light source Receiver
Object
Retroreflective type Without mirror 0.1 to 4m Red LED Light-ON
Light source/receiver
Diffuse reflection type 30cm Infrared Light-ON
Light source/receiver
Note: * The distances in ( ) are the values where a separately-sold reflector PH1X-R1S is used.
Reflector RH1X
Object
surface rejection (0.1 to 5m)*
With mirror surface 0.1 to 2.5m Light-ON rejection (0.1 to 3.5m)*
Object
LED output
(SPDT) Dark-ON
LED
Dark-ON
Dark-ON
Dark-ON
Type
PH4CT-5MRA
PH4CT-5MRB
PH4CR-4MRA PH4CR-4MRB
PH4CR-2HRA PH4CR-2HRB
PH4CD-3CRA PH4CD-3CRB
Supplied item
Cable length
Light source and 2m receiver
Light source and 2m receiver
Light source/ 2m receiver
Light source/ 2m receiver
Light source/ 2m receiver
05
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/61
Page 65
Photoelectric Switches
PH4C
Ratings and specifications
Detection method Transmission type Retroreflective type Diffuse reflection type
Without mirror surface With mirror surface rejection rejection
Type Light-ON PH4CT-5MRA PH4CR-4MRA PH4CR-2HRA PH4CD-3CRA
Dark-ON PH4CT-5MRB PH4CR-4MRB PH4CR-2HRB PH4CD-3CRB Light emitting element Infrared LED Red LED Infrared LED Supply voltage 24 to 240V AC ±10% 50/60Hz, 12 to 240V DC ±10% (ripple ±10% or less) Current consumption 3W max. 2W max. Detecting distance 5m 0.1 to 4m 0.1 to 2.5m 30cm
Detectable target Opaque 14.8mm dia. min. Opaque 75mm dia. min. Transparent or opaque
Directional angle Light source and Light source/receiver: 1 to 5˚, Reflector: 40˚–
receiver: 3 to 20˚ each
Differential Max. 20% of detecting
Detecting output Contact output: 250V AC 3A (cos ø =1), 5V DC 10mA Relay durability Mechanical 50 millions operations (at 18,000 operations/hour)
Electrical 100,000 operations (at 1,800 operations/hour) Response time 30ms max. (operation/reset) Indicator Red LED (on when light is incident) Power supply indicator for light source
Connection Attached cable (2m, 0.3mm
Sensitivity adjustment Dial type Ambient operating illumination Incandescent lamp: 3,000 lx max. (at receiving surface) Ambient temperature Operating: –25 to +55˚C (no icing), storage: –30 to +70˚C Ambient humidity Operating: 45 to 85%RH (no condensation), storage: 35 to 95%RH Degree of protection IP64 (IEC) Insulation resistance 20M (500V DC megger) Dielectric strength 1,500V AC 50/60Hz for 1min Vibration 10 to 55Hz, 1.5mm double amplitude (2 hours for each X, Y, Z direction) Shock 500m/s Material Casing Acrylonitrile butadiene styrene resin (ABS)
Lens Methacrylic resin (PMMA)
Mass Approx. 420g Approx. 250g Approx. 250g
Accessory (supplied) Mounting bracket (PH4X-P1), reflector PH1X-R1 (only for retroreflective type)
Note: * Reflector PH1X-R1 is supplied, PH1X-R1S is sold separately.
2
(3 times for each X, Y, Z direction)
(using PH1X-R1) * (usingPH1X-R1) * (white mat paper 10x10cm)
0.1 to 5m 0.1 to 3.5m (using PH1X-R1S) * (using PH1X-R1S) *
distance
2
)
Type number nomenclature Ordering information
Specify the following
1. Type number
Information subject to change without notice
Basic type
PH : Photoelectric switch
Series
4C : with AC/DC supply voltage
Detecting method
T : Transmission type R : Retroreflective type D : Diffuse reflection type
Detecting distance
3C : 30cm 2H : 2.5m 4M : 4m 5M : 5m
05/62
PH 4C T-5M R A
Operatoin mode
A : Light-ON B : Dark-ON
Output
R : Relay output
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Page 66
Photoelectric Switches
PH4C
Dimensions, mm PH4CT, PH4CR, PH4CD
PH4CT
Lens ø
21.5
14.8
36.5
2
Optical axis
18
Indicator *
13.4
1
A *
28
50
Mounting bracket
*1 Mounting bracket can be fit on the side "A" too.
2
Power supply indicator for light source, incident light indicator for receiver
*
Reflector for PH4CR
PH1X-R1 (supplied)
PH4CR, PH4CD
18
13.4
1
A *
28
50
Receiving section
Mounting bracket
Mounting bracket
PH4X-P1
Incident light indicator
Lens
Light source section
25
PH1X-R1S (optional)
40.3
2–ø3.5
59.9
34
7
Reflection
52
surface
7.5
8
1.6
Reflection surface: Methacrylic resin (PMMA) Reverse side: Acrylonitrile butadiene styrene resin (ABS)
2.7
12
22
2–ø4.4
2
31
10°
6.4
45°
Optical axis
40
4
9
40
45°
R56.6
Sensitivity adjuster (Diffuse reflection type only)
12
22
6.4 4
10
12
6.4
ø6
18
742
50 40
4.4
24 58
5
40
22
60°
Cable: 2m, 0.3mm
2
Panel drilling
2–M6 or ø6
42
9
ø
6
42
50 40
R56.6
58
21
12
6.4
18
7
5
40
60
05
Characteristic curve, typical
Receiver output - Distance PH4CT-5MR
100
Receiver output allowance (times)
10
1
Operating level
60
0.1 102345678910
Distance (m)
PH4CR-4MR + PH1X-R1 (supplied) PH4CR-2HR
Receiver output allowance (times)
Operating level
100
Reflector: PH1X-R1
50 30
10
5 3
1
0.1 102345
Distance (m)
Receiver output allowance (times)
Operating level
+ PH1X-R1 (supplied) PH4CD-3CR
100
Reflector: PH1X-R1
50 30
10
5 3
1
0.1
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Receiver output allowance (times)
Operating level
10234
Distance (m)
100
Object: White mat paper 10×10cm
50 30
10
5 3
1
0.1
0.10 0.2 0.3 0.4 0.5 0.6
Distance (m)
05/63
Page 67
Photoelectric Switches
PH4C
Characteristic curve, typical Setting range of light source and receiver head
PH4CT-5MR
60
40
Distance Y(cm)
20
0
1234567
20
40
60
X
Y
Optical axis
Distance X(m)
PH4CR-2HR + Reflector PH4CR-4MR + Reflector
15
10
Distance Y(cm)
5
0
5
10
15
PH1X-R1S
PH1X-R1
1 2 3 4 56
Y
PH1X-R1
X
Optical axis
Distance X(m)
15
10
Optical
Y
axis
PH1X-R1
PH1X-R1
Distance Y(cm)
5
0
1 2 3 4 567
5
10
15
X
PH1X-R1S
Distance X(m)
Operating range
PH4CD-3CR
50 40 30 20
Distance Y(mm)
10
0
100 200 300
10 20 30 40
50
Wiring diagrams
PH4CT light source
Power supply indicator (Red)
PH main circuit
White mat paper Black carbon paper SUS (glossy) Al foil (mat back)
400
Distance X(cm)
Power Supply
Brown
(No polarity)
Blue
24 to 240V AC
12 to 240V DC
Size of detecting target - Distance
PH4CD-3CR
500
400
Distance Y(cm)
300
200
100
10 234567891011
PH4CT receiver, PH4CR, PH4CD
Operation indicator (Red)
PH main circuit
White mat paper Black carbon paper SUS (glossy) Al foil (mat back)
Target size (cm)
Power Supply
Brown
Blue
Tc
White
Ta
Black
b
T
Gray
24 to 240V AC 12 to 240V DC
(No polarity)
Timing chart
PH4CT-5MRA PH4CT-5MRB PH4CR-2HRA PH4CR-2HRB PH4CR-4MRA PH4CR-4MRB PH4CD-3CRA PH4CD-3CRB
05/64
Timing chartType
Light incident Light shaded
Incident light indicator
Light-ON (PH4C-RA)
Dark-ON (PH4C-RB)
ON OFF
(Ta) ON
OFF
(Ta) ON
OFF
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 68
Photoelectric Switches

PH8AU

Slot-type photoelectric switches PH8AU
Description
Slot-type photoelectric switches ideal for conveyer application, such as elevators and multi-level parking lifts. The emitter and receiver are constructed as a single unit, eliminating the need to adjust the optical axis or sensitivity. Same mounting method as our slot-type magnefically operated reed switches (type PM1U).
Specifications
Type Operating distance (slot width) Detectable object Light emitting element Supply voltage Current consumption Detecting output
Response time Indicator Connection Ambient operating illumination Ambient temperature
Ambient humidity
Degree of protection Insulation resistance Dielectric strength Vibration Shock Protection circuit Material Lens
Casing
Features
• Protective structure conforms to IP66 (IEC standards), so the product can be used safely in environments with water droplets.
• High speed response time of 1ms.
• Wide supply operating voltage range from 10 to 30V DC.
PH8AU
PH8AU-30DALF PH8AU-30DBLF
30mm Opaque, over 6mm diameter Infrared LED 10 to 30V DC (Peak must be within this range) 45mA or less (NPN) transistor open collector output, load current Dark-ON Light-ON 1ms or less Output indicator (Red LED) 1m attached cable Incandescent lamp: 3000 lx or less, sun light: 10000 lx or less at receiving surface Operating: -25 to +55°C
Storage: -30 to 70°C (no icing) Operating: 35 to 85%RH
Storage: 35 to 95%RH IP66 (IEC) 20Mmin. (500V DC Megger) 1000V AC 50/60Hz 1 minute 10 to 55Hz, 1.5mm double amplitude (X, Y, Z direction respectively 2 hours) 500m/s2 three times for each of three directions X, Y and Z Reverse connection and surge voltage PC PPS
KK02-303A
05
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/65
Page 69
Photoelectric Switches
PH8AU
Wiring diagrams Dimensions, mm
Incident
Brown
light indicator
Photoelectric
Black
switch main circuit
Blue
Type number nomenclature
PH8A U-30 D A LF
Basic type
Detecting method
U: Slot type
Detecting distance
30: 30mm
Load
30
Power supply 10 to 30V DC
30
52
67
3
30 40 62
Mass 150g
Cable length
LF: 1m
Operation
A: Dark-ON B: Light-ON
Power supply and output
D: DC supply, NPN transistor open collector output
M6
M6
depth 10mm
Indicator
6.5 IV cable
3-wire, 0.3mm
12
2
Center of lens
12
14
ø6
Ordering information
Specify the following:
1. Type number (ordering code)
1000
05/66
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 70
Catalog Disclaimer
The information contained in this catalog does not constitute an express or implied warranty of quality, any warranty of
merchantability of tness for a particular purpose is hereby disclaimed.
Since the user's product information, specic use application, and conditions of use are all outside of Fuji Electric FA
Components & Systems'control,
products mentioned for the user's application.
One Year Limited Warranty
The products identied in this catalog shall be sold pursuant to the terms and conditions identied in the "Conditions of Sale" issued by Fuji Electric FA with each order conrmation.
Except to the extent otherwise provided for in the Conditions of Sale issued by Fuji Electric FA, Fuji Electric FA warrants that the Fuji Electric FA products identied in this catalog shall be free from signicant defects in materials and workmanship provided the product has not been: 1) repaired or altered by others than Fuji Electric FA; 2) subjected to negligence, accident, misuse, or damage by circumstances beyond Fuji Electric FA's control; 3) improperly operated, maintained or stored; or 4) used in other than normal use or service. This warranty shall apply only to defects appearing within one (1) year from the date of shipment by Fuji Electric FA, and in such case, only if such defects are reported to Fuji Electric FA within thirty (30) days of discovery by purchaser. Such notice should be submitted in writing to Fuji Electric FA at 5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo, Japan. The sole and exclusive remedy with respected to the above warranty whether such claim is based on warranty, contract, negligence, strict liability or any other theory, is limited to the repair or replacement of such product or, at Fuji Electric FA's option reimbursement by Fuji Electric FA of the purchase price paid to Fuji Electric FA for the particular product.
representations or warranties, whether oral or in writing, expressed or implied, including but not limited to any warranty regarding merchantability or fitness for a particular purpose.
Sale, no agent or representative of Fuji Electric FA is authorized to modify the terms of this warranty in writing or orally.
In no event shall Fuji Electric FA be liable for special, indirect or consequential damages, including but not limited to, loss of use of the product, other equipment, plant and power system which is installed with the product, loss of prots or revenues, cost of capital, or claims against the purchaser or user of the product by its customers resulting from the use of information, recommendations and descriptions contained herein. The purchaser agrees to pass on to its customers and users, in writing at the time inquiries and orders are received by buyer, Fuji Electric FA's warranty as set forth above.
it shall be the responsibility of the user to determine the suitability of any of the
Fuji Electric FA does not make any other
Except as provided in the Conditions of
Caution "Safety precautions"
• Operate (keep) in the environment specied in the operating instructions and manual. High temperature, high humidity, condensation, dust, corrosive gases, oil, organic solvents, excessive vibration or shock might cause electric shock, re, erratic operation or failure.
• Follow the regulations of industrial wastes when the product is to be discarded.
• The products covered in this catalogs have not been designed or manufactured for use in equipment or systems which, in the event of failure, can lead to loss of human life.
• If you intend to use the products covered in this catalog for special applications, such as for nuclear energy control, aerospace, medical, or transportation, please consult our Fuji Electric FA agent.
• Be sure to provide protective measures when using the product covered in these catalogs in equipment which, in the event of failure, may lead to loss of human life or other grave results.
• Follow the directions of the operating instructions when mounting the product.
Page 71
D&C CATALOG DIGEST INDEX
Individual catalog No.
LOW VOLTAGE PRODUCTS Up to 600 Volts
Magnetic Contactors and Starters Thermal Overload Relays, Solid-state Contactors
Manual Motor Starters and Contactors Combination Starters
Industrial Relays, Industrial Control Relays Annunciator Relay Unit, Time Delay Relays
Pushbuttons, Selector Switches, Pilot Lights Rotary Switches, Cam Type Selector Switches Panel Switches, Terminal Blocks, Testing Terminals
Limit Switches, Proximity Switches Photoelectric Switches
Molded Case Circuit Breakers Air Circuit Breakers
Earth Leakage Circuit Breakers Earth Leakage Protective Relays
Circuit Protectors Low Voltage Current-Limiting Fuses
Measuring Instruments, Arresters, Transducers Power Factor Controllers Power Monitoring Equipment (F-MPC)
AC Power Regulators Noise Suppression Filters Control Power Transformers
HIGH VOLTAGE PRODUCTS Up to 36kV
Disconnecting Switches, Power Fuses
Air Load Break Switches Instrument Transformers — VT, CT
Vacuum Circuit Breakers, Vacuum Magnetic Contactors Protective Relays
INDIVIDUAL CATALOG
from D&C CATALOG 20th Edition
05
5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo, 103-0011, Japan URL http://www.fujielectric.co.jp/fcs/eng
Information in this catalog is subject to change without notice.
2010-09 PDF FOLS DEC2005
Loading...