Orders amounting to less than ¥10,000 net per order will
be charged as ¥10,000 net per order plus freight and
other charges.
WEIGHTS AND DIMENSIONS
Weights and dimensions appearing in this catalog are the
best information available at the time of going to press.
FUJI ELECTRIC FA has a policy of continuous product
improvement, and design changes may make this
information out of date.
Please confirm such details before planning actual
construction.
INFORMATION IN THIS CATALOG IS SUBJECT TO
CHANGE WITHOUT NOTICE.
Page 4
Limit switches, AL and K244
series
■Description
FUJI AL and K244 series limit switches
have wide application in such industrial
equipment as machine tools, printing
machines, and transfer machines. These
switches feature a sturdy aluminum diecast housing that is highly resistant to oil,
water, and dust, and long mechanical life
— 10 million operations minimum.
AL series
AL and AL-S series limit switches
feature a forced contact opening
mechanism.
Under abnormal conditions, the
mechanism forces the contacts open to
prevent pitting and fusing.
Gold-plated silver contacts with
scrubbing action have high reliability.
KKD07-027SF-2025SK-580
AL-SK
K244-xP-2K244-gR-2
K244 series
The K244 series is provided with four kinds
of contact operating action: standard normal
stroke, snap action, make-before-break, and
extended stroke.
WK244 of the K244 series has bifurcated
contacts, while HK244 features a scrubbing
action mechanism. These limit switches can
be used in low-level circuits of 3V, 5mA.
Limit Switches
General information
05
■Selection guide
Basic typeALAL-SK244HK244WK244
Rated voltage (max.)550V AC, 250V DC*
Rated thermal current10A (5A*1)10A
Operating cycles per hour7,2003,000
Expected life Mechanical10 millions10 millions10 millions10 millions
standard
Highly reliable gold-plated silver contactsSealed types for oily and wet environments
05/205/1605/2305/23
550V AC/DC
2
400,000500,000
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/1
Page 5
Limit Switches
AL and AL-S
General information
Forced contact opening limit
switches, AL and AL-S series
■ Description
The AL and AL-S series limit switches
feature a forced contact opening
mechanism. This mechanism prevents
contact welding and subsequent
malfunctioning. These series therefore
result in extremely dependable system
controls.
The AL series is available in standard
sizes and the AL-S series is compact
versions of the AL types.
■ Features
• The forced contact opening
mechanism is provided so as to
overcome contact problems.
• Gold-plated contacts and a self
cleaning action ensure contact
reliability.
• Sealed construction
Double oil seals prevent moving parts
and contacts from being contaminated
by exterior oil, grime and grease, an
advantage in dirty industrial locations.
• Operational mode indicator can
replace existing cover with lamp
indicator cover when required.
An LED or neon lamp is used
depending on supply voltage.
• Contact mechanical design
Contact operating mechanisms can be
selected according to the applicationsnap, overlap and normal actions
• Conform to IEC Standard
Roller
Operating head
Operating lever
Actuating shaft
Plunger assembly
AL-N1
AL-SP2
SI-1022
SI-204
Forced operating
mechanism
Rubber
packing
Cover
■ Forced contact opening
mechanism
This mechanism does not operate under
normal conditions. However, when the
switch plunger overtravels under
abnormal conditions the mehcanism
comes into operation and forcibily opens
the NC contacts thus preventing contact
welding.
This action improves the dependability of
electrical systems.
SK-415
SK-416
Plunger
Switching is carried out at the normal
operating position
Normal operating condition
Plunger
SK-417
Normal
operating
position
■ Contact ratings
ContactThermalMake and break current *
actioncurrentACDC
*: When NO and NC contacts are wired in the same potential.
■ UL listed (File No. E44592)
Contact ratings
AC (B300)DC
VoltageOperational current (A)VoltageOperational current (Res. load)
(V)MakeBreak(V)(A)
120303 305
240151.51250.4
2500.2
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
05/2
Free
position
The mechanism operates to open the
contacts when the plunger overtravels
Abnormal condition
Normal
operating
position
Overtravel
position
■ Technical data
Insulation resistance:
Over 100MΩ at 500V DC
Life expectancy
Mechanical: Over 10 million operations
Electrical: Snap action type
100,000 operations at
125V AC 5A res. load
Normal action type
100,000 operations at
110V AC 10A res. load
Allowable ambient temperature:
–10°C to +80°C
Degree of protection: IEC IP67
Information subject to change without notice
Page 6
Limit Switches
AL and AL-S
General information
■ Directional contact operation
AL-N1, AL-N2 and AL-N3 can be
modified in their operational directions.
They will switch in both directions, or in
only one direction, either clockwise or
counterclockwise. The adjustment is
easily carried out by removing the
operating head and changing the
plunger as shown in the photograph.
After the plunger has been reassembled,
replace the head and tighten the screws.
Check operation by moving the arm in
the desired direction.
Standard operating position
OperatesOperates
SK-411
Both
Operates
directions
Operates
■ Adjustment of operating lever
Loosen the locking screw, turn over the
lever and then retighten at the required
position.
Type:
AL-N1, AL-N2, AL-N3, AL-SN1,
AL-SN2, AL-SN3, AL-F1.
By loosening this
screw, the actuator
can be fixed at any
position within
360°
■ Adjustment of lever length
Loosen the adjustment screw, adjust the
length and retighten.
Usable by
deforming the rod;
however, pay
attention to
minimum
bending radius of
rod. The minimum
bending radius is
AL-N2: 25-90mm
AL-SN2: 25-70mm
Adjust lever
by loosening
this hexagonal
bolt
AL-N3: 25-141mm
2mm
AL-SN3: 25-130mm
Adjust rod
length by
loosening
this screw.
■ Cable connection
Refer to the wiring diagram for
connection.
When connecting to conduit remove the
plastic packing piece.
AL type limit switches can be attached
either from the front or the back. In the
case of front mounting type clamp at 4
positions using M5 screws. When
attaching from the back of the panel
tighten at 4 positions by means of M6
screws.
The thread depth of the switch body is
15mm.
05
SK-413
Counterclockwise
Clockwise
directions
directions
■ Changing direction of operating
head
SK-412
AL-N2AL-N3
AL-SN2AL-SN3
■ Roller installable on inner side
AL-N1, SN1AL-N2, SN2, SN5
The operating head direction can be
changed through 90° after having
removed the screw. Care must be taken
because the contact action changes
according to the direction of the plunger
Change the
direction by
loosening
bolt
assembly. Check for correct assembly
after each step has been completed.
Limit switches with adjustable head
direction are AL-N1, AL-N2, AL-N3, ALSN1, AL-SN2 and AL-SN3. In the case
■ Dimensions:
See pages 05/13 to 05/15.
of AL-P2 and AL-SP2, the head direction
of a top push roller plunger type can be
shifted 90° in either direction.
■ Ordering information
Specify the following:
1.Type number or ordering code
SK-410SK-409
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Change the
direction by
removing
bolt
M5, minimum
length 35mm,
plus pan-head
28.5
screw, flat-head
screw, bolt with
hexagonal hole
M6
15
Front mountingRear mounting
05/3
Page 7
Limit Switches
AL and AL-S
General information
■ Type number nomenclature
AL–N1 1 H1 UL
■ Ordering code
PL 1 A–1 A ZU
UL approved
Lamp voltage
A2 : 5 to 8V (LED)
B2 : 10 to 15V (LED)
E2 : 18 to 24V (LED)
H1 : 110 to 220V (Neon)
N1 : Roller lever
N2 : Adjustable length roller lever
N3 : Adjustable length rod lever
N5 :
Adjustable length roller lever (Rubber roller)
P1 : Top push rod plunger
P2 : Top push roller plunger
P3 : Top ball push rod plunger
F1 : Fork roller lever
S1 : Wobble head coil spring rod
S2 : Wobble plastic head spring rod
W1 : Wobble head with cat’s whisker
Y1 : Side push rod plunger
Y2 : Side push roller plunger
Y3 : Side ball push rod plunger
AL : Standard type
AL-S : Compact type
■ Operating and definitions (for snap action type)
Rotary actuation Plunger actuation
OP
TTP
2
FP: Free Position
This is the position where there is no load on the actuator.
OP: Operating Position
This is the position where the actuator travels from the free position
to NO contact closes.
TTP: Total Travel Position
This is the furthest position where the actuator can travel to after
passing the OP without damage to the limit switch.
RP: Release Position
This is the position where the contact resets after the actuator has
travelled from OP.
PT: Preoperating Travel
This indicates the travelling angle or distance from FP to OP.
OT: Overtravel
This indicates the travelling angle or distance from OP to TTP.
TT
1
PT
MD
RP
FP
TT
1
RP
Actuating
shaft
OP
Pre travel
(PT)
TTP
2
OTOT
Switch
plunger
Plunger
bushing
A
Free
position
(FP)
33
PT
MD
TT: Total Travel
This indicates the travelling angle or distance from FP to TTP.
MD: Movement Differential (Travel to Reset)
This indicates the travelling angle or distance from OP to the
position where the contact resets.
OF: Required Operating Force ➀
This indicates the minimum operating force which is required for the
contact to close.
RF: Required Resetting Force ➂
This indicates the force required for the contact to reset.
TF: Full Overtravel Force ➁
This indicates the force required for the actuator to travel from FP to
TTP.
UL approved
Lamp voltage
A : LED 5 to 8V
B : LED 10 to 15V
E : LED 18 to 24V
D : Neon
A : Roller lever
B : Adjustable length roller lever
C : Adjustable length rod lever
D : Top push rod plunger
E : Top push roller plunger
F : Top ball push rod plunger
G : Fork roller lever
H : Wobble head coil spring rod
J : Wobble plastic head spring rod
K : Wobble head with cat’s whisker
L : Side push rod plunger
M : Side push roller plunger
N : Side ball push rod plunger
R:
Adjustable length roller lever (Rubber roller)
Series
1 : Standard type
2 : Compact type
Limit switch
Movement characteristics
Overtravel
(OT)
1
B
Operating
position
(OP)
Position of plunger
1
Required
operating
force
(OF)
Movement
diffrential
(MD)
2
C
Total travel
position
(TTP)
2
Full
overtravel
force
(TF)
Forces acting on plunger
3
D
Release
position
(RP)
3
Required
release
force
(RF)
Total travel
(TT)
A
C
B
D
05/4
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 8
Limit Switches
Actuate AL-SP1 type in
direction coinciding
with plunger shaft
direction
61.5
ø
17.5
roller
75° or less
45° or less
ø70
When actuating
switch beyond this
range, contact may
make/break two
times or more
AL and AL-S
■ Actuating slider face angle and approach speed
Standard type
Required operating force OF (max.)9N9N2.9N15N15N15N9.5N
Required resetting force RF (min.)0.5N0.5N0.15N8.2N8.2N8.2N—
Preoperating travel PT (min.)12°12°12°2mm2mm2mm55°
Overtravel OT (min.)65°65°65°5mm5mm5mm35°
Movement differential (Travel to reset) MD (max.) 7° 7° 7°1mm1mm1mm—
Total travel TT (min.)75°75°75°———90°±10°
Required operating force OF (max.)40N40N40N1.5N1.5N1.5N
Required resetting force RF (min.)8.9N8.9N8.9N———
Preoperating travel PT (min.)2.8mm2.8mm2.8mm30mm30mm40mm
Overtravel OT (min.)4mm4mm4mm———
Movement differential (Travel to reset) MD (max.)1mm1mm1mm———
Standard type (Normal action, overlap action)
Overlap actionNormal action
Type
Required operating force OF (max.)
Movement to NC contact open
Movement to NO contact closed
Total travel TT (min., max.)
Notes: *1 At lever length 38mm
*2
At rod lever length 135mm
AL-N12
AL-N22
11N
28˚
45˚
75˚
*1
AL-N32
3.1N
28˚
45˚
75˚
*2
AL-P12
AL-P22
AL-P32AL
18N
3.5mm
5mm
7mm
AL-N13
AL-N23
11N
45˚
28˚
75˚
*1
AL-N33
3.1N
45˚
28˚
75˚
*2
AL-P13
AL-P23
AL-P33
18N
5mm
3.5mm
7mm
05/8
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 12
■ AL-S series/Compact-size
Description
Top push rod plunger
• Operated by a vertical rod plunger.
• Momentary action
TypeOrdering code
AL-SP11PL2D-1
AL-SP12PL2D-2
AL-SP13PL2D-3
KKD07-032
AL-SP11UL PL2D-1ZU
Top push roller plunger
• This is a limit switch where the roller is attached to
the plunger.
Required operating force OF (max.)4.5N8.5N4N4N7N7N7N7N1.5N
Required resetting force RF (min.)2N4.5N1.8N1.8N0.5N0.5N0.5N0.5N—
Preoperating travel PT (min.)2mm2mm2.5mm2.5mm30°30°30°30°30mm
Overtravel OT (min.)4mm3mm5mm5mm40°40°40°40°—
Movement differential (Travel to reset) 1mm1mm1.8mm1.8mm 8° 8° 8° 8°—
MD (max.)
Notes: *1At lever or rod level length 25mm
2
*
At lever or rod level length 30mm
Compact type (Normal action, overlap action)
TypeAL-SP12
Required operating force OF (max.)
Movement to NC contact open
Movement to NO contact closed
Total travel TT (min., max.)
Replace the 쏔 mark by the contact action code
Replace the 쐽 mark by the lamp voltage code
Compact type
KKD07-028
NO
34
12
NC
L
Power supply
The lamp lights when
NO contact closes
Load
L
NO
34
12
NC
Power supply
The lamp lights when
NO contact opens
Load
05/10
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 14
Limit Switches
AL and AL-S
■ Accessories
DescriptionOperatingTypeOrdering code
Standard type sealedCable dia. ø7.5 – ø11.5 (for AL type)ALX-016PL1XW-A
conduit (øD)ø7 – ø11 (for AL-S type)ALX-510PL1XW-B
22
ø
12
(Plastic)
Complete type sealedCable dia. ø6 – ø9ALX-013PL1XW-C
24
conduit (øD)ø8 – ø11ALX-014PL1XW-D
(Metal)
SI-233
Lamp cover for AL seriesFor snap actionLED lamp 6V DCALX-011APL1XL-1A
SI-232
Lamp cover for AL-S seriesFor snap actionLED lamp 6V DCALX-507APL2XL-1A
SI-350
Cable
15
Packing
Min. 15
149
Washer
Nut
PackingO ringCondiut
68
40
6.5
50
30
Limit switch
D
ø
G1/2
5
(42.5)
9.2
(35.7)
(PF1/2)
ø12 – ø14ALX-015PL1XW-E
G-16
[PF-1/2]
(for AL type, AL-S type, AL1-S type)
LED lamp 12V DCALX-011BPL2XL-1B
LED lamp 24V DCALX-011EPL1XL-1C
Neon lamp 110/220V AC ALX-011HPL1XL-1D
For normal action LED lamp 6V DCALX-012APL1XL-2A
LED lamp 12V DCALX-012BPL1XL-2B
LED lamp 24V DCALX-012EPL1XL-2C
Neon lamp 110/220V AC ALX-012HPL1XL-2D
LED lamp 12V DCALX-507BPL2XL-1B
LED lamp 24V DCALX-507EPL2XL-1C
Neon lamp 110/220V AC ALX-507HPL2XL-1D
For normal action LED lamp 6V DCALX-508APL2XL-2A
LED lamp 12V DCALX-508BPL2XL-2B
LED lamp 24V DCALX-508EPL2XL-2C
Neon lamp 110/220V AC ALX-508HPL2XL-2D
05
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/11
Page 15
Limit Switches
16
6.5
8.5
ø3.2
160
AL and AL-S
■ Actuators
For AL series
DescriptionType
Roller leverALX-001
ø
17.5
38
18
6
7
11.4
Stainless
steel roller
For AL-S series
DescriptionType
Roller leverALX-501
ø
17.5
25
SI-316SI-177
5
6.3
6
Stainless
steel roller
Adjustable length roller leverALX-003
ø
SI-173
17.5
97.3
20.5
15.7
7
Adjustable length rod leverALX-005
ø
3.2
141
SI-171
6.4
11.4
Fork roller leverALX-007
ø
17.5
77
Stainless
steel roller
Stainless
steel rod
Stainless
steel roller
Adjustable length roller leverALX-503
5
12
KKD07-033
ø
17.5
86.5
16
Adjustable length rod leverALX-505
KKD07-034
Stainless
steel roller
Stainless
steel rod
38
SI-175
Fork roller leverALX-009
ø
38
SI-176
05/12
17.5
38
11.4
77
Stainless
steel roller
38
11.4
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 16
■ Dimensions, mm (AL series)
Roller lever
AL-N1
ø17.5
R38
14.7
58.5
53
7
13.1
Adjustable length roller lever
AL-N2
65.5
ø17.5
25 - 90
14.7
60
7
13.1
Limit Switches
AL and AL-S
Adjustable length rod lever
AL-N3
6.4
ø3.2
141
14.7
53.1
13.1
46
58.7
5
30.2
40
4-ø5.2
G1/2 (PF1/2)
Mass: 265g
Top push rod plunger
AL-P1
ø10
PT : 2 max
3458.75
4-ø5.2
30.2
40
Mass: 165g
G1/2 (PF1/2)
Fork roller lever
AL-F1
ø17.5
R38
14.7
21.6
15.5
4-M6
29.2
41
Stainless
steel roller
13.1
21.6
15.5
4 - M6
29.2
41
Stainless
steel plunger
58.5
53
40
7
13.1
58.7
5
Mass: 305g
30.2
40
4-ø5.2
G1/2 (PF1/2)
21.6
15.5
29.2
41
Stainless
4-M6
58.7
5
Mass: 260g
steel roller
Top push roller plunger
AL-P2
ø17
PT : 2 max4458.75
4-ø5.2
30.2
40
Mass: 200gMass: 200g
G1/2 (PF1/2)
13.1
4.8
21.6
15.5
29.2
41
Stainless
4 - M6
Top ball push rod plunger
AL-P3
PT : 2 max
44.4
58.7
5
steel roller
Side push rod plunger
AL-Y1
PT : 2.8 max
17.8
ø10
53.7
13.1
Side push roller plunger
AL-Y2
30.2
ø15.5
30.2
40
4.8
40
4-ø5.2
G1/2 (PF1/2)
4-ø5.2
G1/2 (PF1/2)
PT : 2.8 max
ø17
Stainless
steel rod
Stainless
steel ball
67.3
13.1
29.2
41
15.5
29.2
41
13.1
21.6
15.5
21.6
4-M6
05
4-M6
58.7
5
30.2
40
4-ø5.2
G1/2 (PF1/2)
Mass: 310gMass: 285g
21.6
15.5
29.2
41
Stainless
4-M6
58.7
5
Mass: 275g
30.2
40
4-ø5.2
G1/2 (PF1/2)
steel roller
21.6
15.5
4-M6
29.2
41
Stainless
steel plunger
58.717.8
5
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
30.2
40
4-ø5.2
G1/2 (PF1/2)
21.6
15.5
4-M6
29.2
41
Stainless
steel roller
05/13
Page 17
Limit Switches
AL and AL-S
■ Dimensions, mm (AL series)
Side ball push rod plunger
AL-Y3
PT : 2.8 max
67.2
13.1
Wobble head coil spring rod
AL-S1
140
Wobble plastic head spring rod
AL-S2
ø7
13.1
Polyamide resin
61.5
140
ø7
13.1
58.717.8
5
30.2
40
4-ø5.2
G1/2 (PF1/2)
Mass: 285gMass: 220g
21.6
15.5
4-M6
29.2
41
Stainless
steel ball
58.7
5
Wobble head with cat’s whisker
AL-W1
ø1.4
58.7190
5
115
30.2
40
G1/2 (PF1/2)
4-ø5.2
21.6
15.5
29.2
41
13.1
4-M6
30.2
40
4-ø5.2
G1/2 (PF1/2)
21.6
15.5
4-M6
29.2
41
Stainless steel
coil spring
58.7
5
Mass: 210g
30.2
40
G1/2 (PF1/2)
4-ø5.2
21.6
4-M6
15.5
29.2
41
Stainless steel
coil spring
Mass: 210g
05/14
Stainless steel
coil spring
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 18
■ Dimensions, mm (AL-S series/Compact size)
Top push rod plunger
AL-SP1
Top push roller plunger
AL-SP2
Limit Switches
AL and AL-S
Top roller lever plunger
AL-SK1
22
20
PT : 2 max18
55
ø6
4.3
30
15
30
Polyamide
resin plunger
Reversing top roller lever plunger
AL-SK2
PT : 2.5 max
26.8
11
55
13
ø
R18
20
10
20
64
G1/2 (PF1/2)
5
10
PT : 2 max
2855
Mass: 60gMass: 55g
Roller lever
AL-SN1
2055
ø10
30
ø17.5
R25
5
10
30
Stainless steel
roller
47
42
5
10
64
PT : 2.5 max35.855
R18
Mass: 65g
ø13
11
20
30
5
10
30
Stainless steel
roller
Adjustable length roller lever
AL-SN2
05
5
50
45.3
43
10
ø17.5
205525~76
84
30
Mass: 65g
Adjustable length rod lever
AL-SN3
6.5
160
20
55
30
Mass: 105g
30
Stainless
steel roller
51
42.4
ø3.2
30
Stainless
steel rod
30
Mass: 100g
30
30
Stainless steel
Mass: 120g
roller
Wobble plastic head spring rod
AL-SS1
Polyamide
ø4.2
resin
ø5.3
37
10
11355
Mass: 80g
30
Stainless steel
10
30
Adjustable length rubber roller lever
AL-SN51
Rubber
roller
ø 40
30to7620
Mass: 130g
30
Stainless steel
roller
10
56
43
Rubber roller
coil spring
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/15
Page 19
Limit Switches
K244
General information
Momentary-contact limit switches
K244 series
■ Description
FUJI K244 type limit switches have an
excellent performance.
K244 limit switches employ a highly
dependable and long lasting double
break silver alloy contact system.
These can be expected to perform more
than 10 million mechanical operations
and a rate of 3,000 operations per hour.
The large variety of operating types such
as standard stroke, snap-action type,
make-before-break type and extended
stroke type, etc. allow you to select a
suitable limit switch that fully meets your
requirements.
K244 limit switches are widely used for
industrial machinery such as machine
tools, printing machines, conveyors,
automatic machines and door
interlocking and similar applications.
The aluminum die-cast housing can also
be supplied in an oil and water proof
version.
■ Technical data
Insulation resistance:
Over 100MΩ at 500V DC
Dielectric strength:
2500V AC rms 1 minute
Max. operating cycle:
3000 cycles per hour
Life expentancy
Mechanical: 10 million operations
Electrical:
K244-2, 2U and 2V
3.3 million operations at 24 to
550V AC 3A
K244-2S
1.3 million operations at 24 to
550V AC 3A
■ Ordering information
Specify the following:
1.Type number or ordering code
Example
Limit switch ................................ PL
With enclosure................................5
Standard contact ..............................N
Cast-metal clad enclosure .................. G
With top roller lever plunger ................... R
N: Top push rod plunger
R: Top roller lever plunger
W:Reversing, right-hand side roller
SB-401
2
2
05/16
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 20
Limit Switches
K244
■ Actuating slider face angles and
approach speeds
Although K244 limit switches have an
excellent performance they should not
be operated at an extremely high speed
or extremely low speeds, since these
conditions will cause contact trouble and
reduce the mechanical life expectancy of
the devices. The slider face angles and
approach speeds should be kept within
the following recommendations.
Push rod plunger type
This type of switch obtains the
movement from the vertical travel of the
rod.
Speed :Max. 1m/sec
Min. 0.015m/sec
Snap-action types can be used at
speeds less than the minimum value.
Roller lever type
The actuating slider face angles and
speeds should be within the following
range.
The maximum angle of the slider face:
α
1=45°α2=30°
Snap-action type switches can be used
at speeds less than the minimum value.
■ Travel operating force curve
(Typical example)
The curve indicates forces to operate the
contact.
Standard type
K244g-2
NC contacts
open
0
K244gR-2
NC contacts
open
Overtravel
NO contacts
close
3.51.5
Travel
Overtravel
NO contacts
close
10N
5N
64321
5
6.5mm
0
Operating force
10N
5N
■ Changing direction of operating
roller head
Roller head positions can be shifted by
90° in each direction. The head is
attached at the standard position when
shipped from factory.
Standard type
f type
05
2
(m/sec)
4
3
2
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
Speed of slider
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
2V type,
2
upper limit
2V type,
2
lower limit
0 5 10 15 20 25 30
21
2, 2U, 2S,
2V type,
1
lower limit
Slider angle 움
Slider
2, 2U, 2S, 2V type,
1
upper limit
2, 2U, 2S type,
2
upper limit
2, 2U,
2S type,
2
lower limit
Max. value
of 움
2
35
1
40 45
Max.
value
of 움
0
Snap action contact type
K244g-2S
Margin
Snap
operating
point
1
0
K244gR-2S
Snap
operating
point
End
play
1
0
7
64321
5
4.21.7
6.2
0
7.4mm
Travel
Overtravel
26N
20N
15N
10N
0.6kg
32
1.4
5N
0
4mm
Travel
Overtravel
21N
15N
10N
5N
6
5
4
3
217.4mm
4.3
2.5
7
0
Travel
Operating force
■ Cable connection
Threaded conduit entrances are
provided at 3 locations–left, right and
lower side of the limit switch housing.
Knockout the plug to carry out wiring.
Do not remove plugs from holes not
requiring wiring.
Operating force
Threaded
conduit
entrance
SDO-0115M.
K244gR-2
Operating force
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/17
Page 21
Limit Switches
K244
Standard type
■ K244 series/Standard
DescriptionContactTer-TravelTypeOrderingDimensions, mm
arrangementminalContact closedcode
No.Contact open
Top push rod plunger with1NO+1NC
transparent plastic cover
4
Normal strokeK244xp-2 PL4NN-22
Snap-actionK244xp-2S PL4NN-21
2
3
1
4
2
13
4
2
Make-before-breakK244xp-2U PL4NN-23
3
1
4
SF2025
Extended strokeK244xp-2V PL4NN-25
2
3
1
S (mm)
1.5
1–2
3–4
023.56.3
1.4
3–4
1–2
024
3
1–2
3–4
02 6
Momentary open
1–2
3–4
068.5
10
6
M4
Terminal
Lead
hole
29
-2-2S-2U-2V
A 21192121
B 1.5 1.5 1.5 1.0
C 6.5 1.4 6 8.5
Mass: 60g
Top push rod plunger1NO+1NCS (mm)
cast-metal clad
T-1535
4
Normal strokeK244g-2PL5NGN-22
Snap-actionK244g-2S PL5NGN-21
2
3
1
4
2
13
4
2
Make-before-breakK244g-2U PL5NGN-23
3
1
4
2
Extended strokeK244g-2V PL5NGN-25
3
1
1.5
1–2
3–4
023.56
1.4
3–4
1–2
04
1–2
3–4
1–2
3–4
3
02 5
Momentary open
068.4
16
5.5
22
2
16
42
Earth
terminal
-2-2S-2U-2V
A 26242626
Mass: 200g
Top push rod plunger oiltight1NO+1NCS (mm)
and watertight cast-metal clad
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
05/18
Information subject to change without notice
Page 22
■ K244 series/Standard
16115
145
AS
ø5
16
5.5
44
4
44
60
45
16
25
1
3-ø4.5
Mounting
holes
Conduit
entrance
Earth
terminal
Limit Switches
K244
Standard type
DescriptionContactTer-TravelTypeOrderingDimensions, mm
arrangementminalContact closedcode
No.Contact open
Top roller lever plunger1NO+1NC
cast-metal clad
4
Normal strokeK244gR-2PL5NGR-22
Snap-actionK244gR-2S PL5NGR-21
Make-before-breakK244gR-2U PL5NGR-23
T-1537
Extended strokeK244gR-2V PL5NGR-25
2
3
1
4
2
13
4
2
3
1
4
2
3
1
S (mm)
1.7
1–2
3–4
04.27.5
3–4
1–2
1–2
3–4
1–2
3–4
4.3
0
3.6
2.4
0
0.5
07.5
7.5
7.5
16
10
5.5
22
Earth
16431
terminal
Conduit
entrance
S
R26.9
ø22
A
16
75
4
Roller
26
19
2-ø4.5
40
Mounting
holes
4
4
56
Phenal-formaldehyde roller
-2-2S-2U-2V
A 55555557
10
Mass: 240g
Top roller lever plunger oiltight1NO+1NCS (mm)
and watertight cast-metal clad
Snap-actionOiltight
T-1531
4
2
13
3–4
1–2
6.2
0
7.5
K244goR-2S PL5NLR-21
Watertight
K244gwR-2SPL5NWR-21
17
10
6
22
2
Earth
16
terminal
45
Conduit
entrance
58.5
S
19
16
40
75
4
5
56
R26.9
ø22
Roller
5
05
29
Phenal-formaldehyde roller
Mass: 250g
Top push rod plunger2NO+2NCS (mm)
cast-metal clad
432
432
432
432
4
3
1
4
3
1
4
3
1
4
3
1
Normal strokeK244g-2/2PL5NGN-42
2
1
Snap-action
2
1
Make-before-break
2
1
Extended stroke
2
1
➀➁
T-1567
Complex
Normal stroke +
(
Make-before-break
2
1
)
➀➁
Top push rod plunger oiltight2NO+2NCS (mm)
and watertight cast-metal clad
Snap-actionOiltight
T-1567
2
1
432
432
4
3
1
4
3
1
1.5
1–2
3–4
03.56
1.4
3–4
1–2
0
1–2
3–4
0
0.5
1–2
➁
3–4
1–2
➀
3–4
08.4
0
1–2
➁
3–4
1–2
➀
3–4
1.5
3–4
1–2
0
1.4
4
3
K244g-2U/2U
K244g-2S/2S
2
5
6.5
K244g-2V/2V
6
5
32
K244g-2/2U PL5NGN-46
3.5
2.4
K244go-2S/2S
Watertight
K244gw-2S/2S
PL5NGN-41
PL5NGN-43
PL5NGN-45
PL5NLN-41
PL5NWN-41
Brass plunger
2/2 2S/2S 2U/2U 2V/2V 2/2U
A2624262626
Mass: 410g
17
6
6
25
2
16
47
Mass: 420g
Conduit
entrance
Brass plunger
ø5
S
16115
145
5
26
44
3-ø4.5
Mounting
holes
Earth
4
terminal
5
60
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/19
Page 23
Limit Switches
K244
Standard type
■ K244 series/Standard
DescriptionContactTer-TravelTypeOrderingDimensions, mm
arrangementminalContact closedcode
No.Contact open
Top roller lever plunger2NO+2NC
cast-metal clad
Normal strokeK244gR-2/2 PL5NGR-42
Snap-action
Make-before-break
Extended stroke
2
2
4
1
3
1
2
432
1
1
2
432
1
1
2
432
1
1
➀➁
T-1567
Complex
Normal stroke +
Make-before-break
2
432
)(
1
1
➀➁
4
3
4
3
4
3
4
3
4
3
S (mm)
1–2
3–4
04.27.5
3-4
1-2
0
1–2
3–4
0
0
1
1–2
➁
3–4
1–2
➀
3–4
0.57.5
0
1–2
➁
3–4
1–2
➀
3–4
1.7
1.7
2.4
2.4
3.6
3.6
4.3
4.2
K244gR-2S/2S
7.5
K244gR-2U/2U
7.5
8.2
K244gR-2V/2V
10
K244gR-2/2U
7.5
PL5NGR-41
PL5NGR-43
PL5NGR-45
PL5NGR-46
16
10
5.5
25
1
16
45
Phenal-formaldehyde roller
2/2 2S/2S 2U/2U 2V/2V 2/2U
A5555555755
Mass: 440g
Top roller lever plunger oiltight2NO+2NCS (mm)
and watertight cast-metal clad
Snap-actionOiltight
2
4
4
2
1
1
3
3–4
1–2
3
0
6.2
7.5
K244goR-2S/2S
Watertight
K244gwR-2S/2S
PL5NLR-41
PL5NWR-41
17
10
6
A
Conduit
entrance
58.5
145
145
16
115
16
115
S
R26.9
ø22
Roller
26
19
44
3-ø4.5
Mounting
holes
Earth
4
4
terminal
4
60
S
R26.9
ø22
Roller
29
19
44
3-ø4.5
Mounting
holes
T-1567
25
2
18
47
Conduit
entrance
Phenal-formaldehyde roller
Mass: 450g
4
Earth
5
5
terminal
60
05/20
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 24
Reversing roller lever momentarycontact limit switches, K244g첸R
■ Description
These limit switches are designed to
detect the movements in the vertical
direction. The switch body is identical to
the standard type except that one roller
is extended from the housing.
The performance is the same as for the
standard type.
Standard Reversing
■ Ratings
TypeThermal MakingBreaking current *
Right side roller
■ Actuating slider face angles and
approach speeds
K244 limit switches have an outstanding
performance and will have a long service
life under normal conditions. They are
designed to carry out 3,000 operations
per hour but if they are operated at an
extremely high speeds or on the contrary
at extremely low speeds contact trouble
could develop which would reduce the
mechanical life expectancy of the
devices.
Reversing roller levers are provided with
sliders in their vertical direction. The
slider face angles and approach speeds
should be kept within the range shown
by curves. The maximum angle of the
actuating slider is α1=45°, α2=30° and
under. Snap-action types can be used at
speeds less than the minimum value
given.
[m/sec]
4
3
2
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
2V type,
2 upper limit
0.2
Slider speed
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
2, 2U, 2S type,
2 lower limit
0.02
2V type,
2 lower limit
0.01
0
5
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
DescriptionContactTer-TravelTypeOrderingDimensions, mm
arrangementminalContact closedcode
No.Contact open
Reversing top roller lever1NO+1NC
plunger cast-metal clad
Normal strokeK244gRA-2 PL5NGW-22
Snap-actionK244gRA-2SPL5NGW-21
Make-before-breakK244gRA-2UPL5NGW-23
S-2900
Extended strokeK244gRA-2VPL5NGW-25
4
2
3
1
4
2
13
4
2
3
1
4
2
3
1
S (mm)
1.8
1–2
3–4
02 3.86.6
3-4
1-2
1–2
3–4
1–2
3–4
3.6
0
3
02 6
Momentary open
05.7 8.3
6.2
A43.643.643.645.8
Mass: 240g
Reversing top roller lever1NO+1NCS (mm)
plunger oiltight and watertight
cast-metal clad
4
Snap-actionOiltight
2
3
1
3–4
1–2
4.6
06.6
K244goRA-2S
PL5NLW-21
Watertight
K244gwRA-2S
S-2900
PL5NWW-21
Mass: 250g
Reversing top roller lever2NO+2NCS (mm)
plunger cast-metal clad
Normal stroke
Snap-action
Make-before-break
Extended stroke
SF-2028
Complex
Normal stroke +
(
Make-before-break
2
1
2
1
2
1
2
1
2
1
)
➀➁
4
3
4
3
432
4
3
432
4
2
3
1
4
2
3
1
4
3
1
4
2
3
1
4
3
1
1.8
1–2
3–4
02 3.86.6
3.6
3-4
1-2
0
3
1–2
3–4
02 6
Momentary open
1–2
3–4
05.7 8.3
3
0
2
1–2
3–4
1–2
3–4
1.8
3.8
K244gRA-2/2
K244gRA-2S/2S
6.2
K244gRA-2U/2U
K244gRA-2V/2V
6
➁
K244gRA-2/2U
➀
7.5
PL5NGW-42
PL5NGW-41
PL5NGW-43
PL5NGW-45
PL5NGW-46
A 43.6 43.643.645.843.6
Mass: 440g
Reversing top roller lever2NO+2NCS (mm)
plunger oiltight and watertight
cast-metal clad
432
4
3
1
3–4
1–2
Snap-actionOiltight
1
2
4.6
06.6
K244goRA PL5NLW-41
-2S/2S
Watertight
K244gwRA PL5NWW-41
-2S/2S
Mass: 450g
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/22
SF-2028
-2-2S-2U-2V
Phenal-formaldehyde roller
17
10
60.6
16
6
22
2
16
45
Conduit
entrance
75
43.6
19
40
4
5
56
Phenal-formaldehyde roller
16
10
57.6
5.5
25
1
16
45
Conduit
entrance
145
19
44
11516
4
4
604
Phenal-formaldehyde roller
2/22S/2S 2U/2U 2V/2V 2/2U
145
43.6
19
44
11516
4
5
60
17
10
60.6
6
25
2
16
47
Conduit
entrance
Phenal-formaldehyde roller
5
A
3-ø4.5
Mounting
holes
3-ø4.5
Mounting
holes
5
ø22
roller
R21.6
29
3-ø4.5
Mounting
holes
Earth
terminal
ø22
roller
S
R21.6
26
Earth
terminal
ø22
roller
S
R21.6
26
Earth
terminal
S
Page 26
Momentary-contact limit switches
for low voltage circuit
HK244 and WK244
■ Description
HK244 and WK244 limit switches have
been developed for use in low voltage
and low current circuits. They will
operate effectively in 3 Volts AC or DC,
5mA circuits although they are
recommended that they are used in 48
Volts or 110 Volts circuits for best
results.
HK244 limit switches
HK244 limit switches are provided with
pure silver contacts. The movable
contact carries out a scrubbing action
during make/break operation ensuring
good connections at all times.
The switch body is molded from a high
performance resin, and versions with
transparent plastic covers and with
aluminum die-cast housing are also
available.
WK244 limit switches
The bifurcated contact is made of pure
silver and like the HK244 series they are
also suitable for use with low voltage
circuits. The dimensions and operating
strokes are similar to the standard type.
■ Ordering information
Specify the following:
1.Type number or ordering code
Example
Limit switch ................................ PL
With enclosure................................ 5
Scrubbing contact ............................. H
Cast-metal clad enclosure .................. G
Top roller lever plunger .......................... R
Insulation resistance: Over 100MΩ at 500VDC
Dielectric strength:2500V AC rms 1 minute
Max. operating cycle: 3000 cycles per hour
Life expectancy Mechanical: 10 million operations
Electrical: 1.3 million operations at 24 to 550V AC 3A
Allowable ambient temperature: –5° to +60°C
1
1
Contact
scrubbing
completed
2
0.1*
2
Sliding
frame
05
WK244
Insulation resistance: Over 100MΩ at 500VDC
Dielectric strength:2500VAC rms 1 minute
Max. operating cycle: 3000 cycles per hour
Life expectancy Mechanical:10 million operations
Allowable ambient temperature: –5° to +60°C
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Electrical: 1 million operations at 220V AC 1.5A
05/23
Page 27
Limit Switches
HK244 and WK244
■ HK244 and WK244 series
DescriptionContactTravel (mm) of HKHK seriesWK seriesDimensions
Top push rod plunger1NO+1NC
transparent plastic cover
Normal strokeHK244xp-2PL4HGN-22 WK244xp-2PL4WGN-22
ComplexHK244gR-2/2UPL5HGR-46 WK244gR-2/2U PL5WGR-46
Normal stroke +
(
Make-before-break
Reversing top roller lever 2NO+2NC
plunger cast-metal clad
Normal strokeHK244gRA-2/2PL5HGW-41 WK244gRA-2/2 PL5WGW-41
Make-before-break
ComplexHK244gRA-2/2U PL5HGW-46 WK244gRA-2/2U PL5WGW-46
Normal stroke +
(
Make-before-break
Contact closed
Contact open
arrange-seriesWith scrubbingWith bifurcated(Same as
ment(WK series: Same ascontact actioncontactK244)
standard series, pagesTypeOrderingTypeOrdering
05/115 to 05/117)codecode
4
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
2
2
4
1
3
3
1
2
1
2
1
)
➀
2
13
2
1
2
1
)
➀
24
13
2
1
214
➀
)
4
2
4
1
3
3
4
4
2
3
3
1
➁
4
2
4
1
3
4
2
4
3
1
3
4
4
2
3
1
3
➁
2
4
3
1
4
2
4
3
3
1
4
2
3
1
3
➁
2
1–2
3–4
036.5
1–2
3–4
1–2
3–4
1–2
3–4
1–2
3–4
1–2
3–4
1–2
3–4
1–2
3–4
1–2
3–4
1–2
3–4
3.5
0 1.56
2
1–2
3–4
0
3
3.5
1–2
3–4
0 1.5 4
2.2
03.77.5
4.1
0 1.97.5
2.2
03.26.2
3.8
0 1.86.2
2
1–2
3–4
036
1–2
3–4
1–2
3–4
1–2
3–4
1–2
3–4
1–2
3–4
1–2
3–4
1–2
3–4
3.5
1.5
0
0
2
3
1.55
3.5
0
2.2
03.77.5
4.1
0 1.97.5
3.7
2.2
0
4.1
0 1.97.5
2.2
03.26.2
3.8
0 1.86.2
0
2.203.2
3.8
1.8
Page 05/18
Page 05/18
6
Page 05/18
Page 05/18
Page 05/19
Page 05/19
Page 05/22
Page 05/22
Page 05/19
5
5
➀
Page 05/19
Page 05/19
➁
Page 05/20
Page 05/20
7.5
➀
Page 05/20
➁
Page 05/22
HK244gRA-2U/2U
6.2
➀
➁
6.2
PL5HGW-43
WK244gRA-2U/2U
PL5WGW-43
Page 05/22
Page 05/22
05/24
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 28
Proximity Switches
General information
SP-387KK02-298A
PE-LPE1-C, PE2-CPE1-Y
SM-81AF91-508AF89-744SK586
PE-UPE-X3D
Proximity switches, PE series
■ Description
These proximity switches have many
advantages over conventional limit
switches, enabling their use where other
switches will not do. FUJI offers two
types – inductive and magnetic. Sensors
PE-T
PE-B7
■ Features
PE-U series
(See page 05/28)
• Operating distance: 7mm and 10mm
• Operating voltage range:
10 to 30V DC
• Suitable for detecting of ferromagnetic
materials
and switching components are
completely enclosed for protection
against oil mist, metal fillng, dust, and
moisture.
Inductive types use a solid-state
switching device; magnetic types use a
reed switch.
PE1-C and PE1-Y series
(See page 05/29)
• Short length achieved with IC
• 6 shielded and 4 non-shielded types
• AC 2-wire, DC 2-wire, and DC
3-wire systems
• Stable operating indicator provided as
standard (mounting diameter M12 or
PE series proximity switches
more, and NO contact type).
Inductive type
Inductive proximity switches are
available in AC or DC versions.
The PE-U series is slot type.
The PE1-C and PE1-Y series are
cylindrical. The detecting surface of PE-B
series is square. The PE-T series
switches are slim types. The PE1B2P is
PE-B series
(See page 05/33)
• 4mm to 50mm operating distance
• Types with operating distance
exceeding 20mm conform to the
CENELEC Standard.
• Operating voltage range:
80 to 250V AC or 10 to 30V DC
AF89-193
PE-L series
• Output voltage proportional to distance
• Linearity: ±1.5% of full scale
Resolution: ±0.05% of full scale
• DC 2-wire, DC 3-wire and AC/DC
2-wire operating systems
• 40 to 250V AC/20 to 250V DC
(AC/DC 2-wire system)
PE-X3D series
• Only 7mm thick
• Operating voltage range:
10 to 30V DC
PE-G4D
• Requires about half the mounting
space of PE-B4 type.
compact square type. The PE-L series
has analog outputs with the sensor and
amplifier separated. The PE2-C series is
cylindrical and with stable operating
indicator. The PE-X3D is flat type, and
PE-X15D series
(See page 05/36)
• Square-flat type
• DC supply/3-wire, 12/24V DC
• Operating distance: 15mm
PE-4BS2 series is multiple type.
The PE-G4D is space-saving square
type.
PE-T series
(See page 05/36)
• Unique “Magnetic Shield Method”
permits side-by-side mounting
• Only 12mm thick – achieved with IC
• Built-in reverse polarity and surge
voltage protection
AF89-458
PE2-CTS
05
(See page 05/39)
(See page 05/43)
(See page 05/47)
(See page 05/49)
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/25
Page 29
Proximity Switches
General information
PM-4M
AES202B-1A
AER201L-1A
X-806
PM-1U
FA-1446
PM-2S
FA-1445
AEQ010-1A
AF9-49
X806
FA-1446
AES, AER and PM type proximity
switches (Magnetically-operated reed
switches)
In the standard type PM the reed switch
element and the sensing magnet are
separate elements. The AES type is also
a separate type but is a miniaturized
version. In the AER type the sensing
magnet element and the reed switch are
integrated in one housing.
■ Features
• Since these proximity switches make
use of a permanent magnet no
external power source is required to
operate the reed switch.
• The dry reed contact switch is
dependable in operation and has an
extended service life.
• The unit strongly resists vibration and
is both water-and dust-tight (except for
AES type).
• Either an AC or DC power source can
be used for the reed switch output.
• Compact in design and easy to install
anywhere.
• Can be mounted on a steel frame (In
this case the effective operating
distance is reduced by one-half).
■ For further information
See pages 05/51, 52, 54, 55.
Inductive type
■ Description
Standard metal plate (object)
Standard metal plate (object) is a
standard sensing target to measure the
basic performance. Its shape, size, and
material are stipulated. Iron is usually
used as material.
L
W
t
Operating distance
The operating distance is the
distance along the center axis of the
head from the sensing head to the point
where a metal plate traveling along the
path actuates the switch.
Normally the operating distance means
this distance in vertical direction.
Reset(OFF)
Operate(ON)
Standard
metal plate
The following curves indicate typical
operating distances. Values for
aluminum or copper will be less than 1/2
those indicated for iron. In order for an
object to be detected, its dimensions
must be no smaller than 30 × 30mm, or
no larger than 70 × 70mm. Objects
smaller or larger will not be detected,
regardless of material.
22
20
18
16
14
Operating distance (mm)
12
10
8
Differential
Operating
distance
Sensing head
Center axis
Operating
Thickness:1mm
Resetting
distance
Fe
Resetting
Cu
Differential distance
This is the distance between the
actuating point where the switch is
actuated and the reset point where the
switch resets after the metal plate is
withdrawn from the sensing head.
Response curve
This curve shows the detect-to-reset
range with object distance from the
head. The switch operates when the
object approaching form the left reaches
point P on curve ‘a’, and resets when the
trailing edge of the object reaches point
Q on curve ‘b’.
The switch also resets when the object
is withdrawn from point P to R on curve
‘d’.
Resetting distance
Operating distance
Y
Q
XX
d
a
Resetting
point
b
c
Metal plate
R
P
Operating
point
Sensing head
05/26
50sq
30sq
20sq
Size of metal plate (mm square)
70sq
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 30
Proximity Switches
Magnet
m
Reed switch
Operating position
Reset position
Range of reset points
Range of operating points
General information
Magnetically operated type
■ Operating
These switches comprise a sensor and a reed switch element,
which closes when a magnetic object approaches.
■ Reed switch
The constructions of the reed switch and its magnetic element
are shown in the diagram. The reed switch is made up of two
magnetic reeds in an airtight glass tube. The 2 reeds are
magnetized when they come within the magnetic field of the
magnetic element. In this case the tips of these 2 reeds have
positive and negative charges respectively and are attracted to
each other. When the magnetic field is removed the magnetic
charge is lost and the reed switch opens.
FUJI’s reed switches are designed to operate in the same
manner as the snap-action of conventional limit switches.
Magnet
N
S
S
N
■ Operating characteristics
Short axis
Magnet: Travel
Reed switch: Fixed
The reed switch closes when ‘m’ the magnet center reaches ‘쐌’
position. It resets at ‘x’ position.
Operating position
Reset position
Range of reset points
Range of operating points
Magnet
m
m
Reed switch
m
Long axis
Magnet: Travel
Reed switch: Fixed
This method is feasible but if the distance between the magnet
and the reed switch is not correct the reed switch may switch 3
times when the magnet carries out only 1 travel.
Try to avoid using this arrangement.
05
Reed switch
Airtight glass tube
■ Mode of operation
The operation methods of the magnetic type proximity switches
are as illustrated.
Separation type
MagnetMagnetMagnet
Reed
switch
Reed switch is fixed
but magnet moves in
a vertical direction.
Reed switch is fixed but
magnet moves in a
horizontal direction.
Reed
switch
Metal
piece
Both the reed switch and
magnet are fixed. And
metal object passes
between these two.
Reed
switch
Integrated type
Proximity
limit switch
Proximity
limit switch
Short axis
Magnet: Fixed
Reed switch: Fixed
(In this case the reed switch operates as an NC contact.)
Reed switch closes when the metal piece is out of ‘X’ region
between the magnet and the reed switch.
When the metal piece passes through the ‘X’ region the reed
switch will open. Thus the reed switch opens as soon as ‘c’ the
tip of the metal piece reaches ‘X’ region and closes as soon as
‘d’ the end leaves ‘Y’ region.
Reed switch
dcc
Metal piece
Magnet
d
Y area (Resetting)
X area (Operating)
Proximity switch is fixed and the
metal object moves in a
horizontal direction.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Metal pieceMetal piece
Proximity switch is fixed and the
metal piece moves forwards and
backwards.
• The slot type detecting surfaces of 12
and 25mm are available.
Stable detection characteristics can be
obtained when a metal plate passes
through the slot ON or OFF-center.
• Best suited for detection of magnetic
metal plates passing through the slot.
■ Specifications
Type (Ordering code)
Operating distance
Standard target size (iron)
Supply voltage
Operating voltage range
Power consumption
Output capacity
Response time or frequency
Differential
Ambient temperature
Degree of protection
Insulation resistance
Dielectric strength
Mass
Note: * This indicates the distance “a” shown in
figure at right.
PE-U25NT (PE1U25-ND)
10mm ± 2*
50 × 50 × 2.3mm
12/24V DC
10 to 30V DC
Max. 20mA at 24V DC
Max. 100mA
Max. 3ms. (ON time)
0.3 to 2mm
–25 to +70°C
IP67 (IEC)
Over 50MΩ at 500V DC
2000V AC rms. 1minute
210g
• Provided with built-in reverse polarity
and surge voltage protection circuits.
• LED indicator lamps are provided, thus
facilitating operational checks.
• Degree of protection meets the
requirement of IP67 (IEC), thus
permitting operation in unfavorable
environments.
• NPN transistor voltage/current outputs
are provided, thus permitting a wide
range of applications.
PE-U12D (PE1U12-D)
7mm ± 1*
40 × 40 × 1mm
Max. 15mA at 24V DC
Max. 50mA
Min. 50Hz
Max. 15% of operating distance
1000V AC rms. 1minute
120g
a
Target
PE-U12D: 4mm
PE-U25NT: 15mm
Target
PE-U12D
AF91-511
■ Response curve
PE-U12D
X
Y
4
X
(mm)
6420642
PE-U25NT
Y (mm)
X
(mm)
X
15
Y
6
810
2
4
16
14
12
10
8
6
4
2
0
Y (mm)
10
8
6
4
2
PE-U25NT
SM-81
Target
40x40x1mm iron
Target
50x50x2.3mm iron
OFF
ON
642
810
OFF
ON
X
(mm)
■ Wiring diagrams
PE-U12D
Brown
4.7kΩ
Black
Blue
Proximity
switch
NPN transistor current output, 1NO
PE-U25NT
Promixity
Object
NPN transistor voltage/current output, SPDT
05/28
switch
Load
4.7kΩ
10kΩ
10kΩ
+
–
Brown
Black
(N.O)
White (N.C)
Blue
Load 2
■ Dimensions, mm
PE-U12D
+
–
50
30
40
35
47.5
8.5
Cable = 1m
0.2mm 3 core
PE-U25NT
5
4.5
25
40
12
■ Ordering information
ø4
Specify the following:
1.Type number or ordering code
2
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
AC supply/2-wire system
Operating distance: 0.8 to 20mm
This proximity switch has a cylindrical
shape. The sensor is fitted to an end of
the cylinder and the body is provided
with a built-in control circuit.
This type conforms to the requirements
of the CENELEC (Europe) Standards
and as the dimensions, ratings and
performance comply with the
Current consumption10mA or less at 24V DC15mA or less at 24V DC––
Leakage current––0.8mA or less at1.5mA or less at
Ambient temperature–25 to 70°C–25 to 80°C–25 to 80°C–25 to 80°C
Dielectric strength250V AC 1 min.1000V AC 1min.1000V AC 1 min.2000V AC 1 min.
Insulation resistance50MΩ or more at 250V DC megger50MΩ or more at 500V DC megger
Degree of protectionIP67 (IEC Standard)
Vibration10-55Hz, 1.5mm double amplitude (in X, Y, Z directions, respectively for 2 hours)
Shock500m/s
Protection circuitReverse polarity and surge voltageReverse polarity, short-circuit and surge voltageSurge voltage
PE1-CS08D, DBPE1-CS08Q, QBPE1-C쏔D, DBPE1-C쏔Q, QBPE1-C쏔S, SBPE1-C쏔A, AB
open collectoropen collectoropen collectoropen collectoroutputoutput
outputoutputoutputoutput
Supply voltage12/24V DC *
Output capacityMax. 200mA at 12/24V DCMax. 100mA10 to 200mA
Current consumptionMax. 15mA at 24V DC0.8mA or less2mA at 200V AC
Ambient temperature–25 to +75°C–25 to +75°C–25 to +75°C
Dielectric strength2000V AC, 1 min.2000V AC, 1 min.2000V AC, 1 min.
Insulation resistanceOver 50MΩ (500V DC megger)
Degree of protectionIP67 (IEC)
Response frequencySee table below
Vibration10 to 55Hz, 1.5mm double amplitude (in X, Y and Z direction, respectively for two hours)
Shock500m/s
Circuit protectionShort-circuit (except PE-B쏔A and PE-B쏔AB), reverse polarity, surge voltage
Notes: *1Operational voltage range: 10 to 30V DC *2 Operational voltage range: 80 to 250V AC.
DC supply/3-wire system
Supply voltage range: 10 to 30V DC
Operating distance: 15mm
■ Features
• Degree of protection meets the
requirements of IEC IP66, thus
permitting operations in unfavorable
environment.
■ Specifications
Type (Ordering code)
Operating system
Output
Operating distance
Target size (iron)
Differential distance
Rated voltage
Switching capacity
Current consumption
Residual voltage
Response frequency
Variation due to voltage
fluctuation
Variation due to temperature
fluctuation
Dielectric strength
Insulation resistance
Degree of protection
Ambient temperature
Humidity
Vibration
Shock
PE-X15D
DC supply/3-wire
NPN transistor, open collector, 1NO
15mm ±10%
50×50×1mm (iron)
Max. ±10% of operating distance
12/24V DC (10 to 30V DC)
200mA max.
15mA max. at 24V DC
1.5V max. at 24V DC, 200mA
100Hz
Max. ±1% of operating distance at 12/24V DC when
operated within 10 to 30V DC
Max. ±10% of operating distance at 20°C within
temperature range of –25 to +70°C
1000V AC, 1min.
50M⏲ or more (500V DC)
IP66 (IEC)
–25 to +70°C (avoid icing)
35 to 95% RH
10–55Hz, 1.5mm double amplitude
500m/s2 (approx. 50G)
• Only two screws are needed to affix
each switch, eliminating the need for
exclusive mounting brackets.
• Incorporates surge suppression
circuits and protection circuits
against reverse polarity and shortcircuits.
PE-X15D
■ Response curve for iron
Material: Iron
50×50×1mm
Y (mm)
15
X
Y
1551015
Influence of surronding metals:
•
When mounting a proximity switch surrounded by
metals, be sure to provide a minimum distance as
shown below.
10
5
010
5
X (mm)
■ Wiring diagrams
Proximity
switch
05/36
Brown
Black
Blue
Load
■ Dimensions, mm
10-30V
DC
35
23
12
28
ø28
28
352000
5
indicator
4–ø3.5
ø4
10±3
30±5
IV cable 0.2mm
8
2
Mass: 80g
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 40
Proximity Switches
PE-T
Inductive proximity switches–
Slim type, PE-T
Supply voltage: 12/24V DC
120/240V AC
Output capacity: Max. 200mA
• Wide operating voltage range
Operating range of supply voltage is
from 80 to 250V AC or from 10 to 30V
DC.
• LED indicators are provided for all
types thus facilitating operation
■ Features
• Unusual “Magnetic Shield Method”
permits to mount these units side by
side, touching each other. (Shielded
type PE-TS2)
• Only 12mm in thickness because of
the use of IC.
• The accuracy of linearity is ±1.5% of
full scale and the resolution accuracy
±0.05% of full scale, thus permitting a
■ Description
These switches are ideally suited for
deformation inspections, position
controls of laser beam machines and
similar displacement measurements and
controls of a variety of machines.
■ Features
• Red LED indicator lamp
• Output voltage proportional to the
highly accurate measurement and
detection of minute displacement of
distance.
• Provided with 2 switching output
circuits so as to detect an arbitrary
position within the detecting range by
incorporating a built-in comparator
circuit.
• Provided with a SPAN indicator lamp.
distance from the object.
Sensor Amplifier unit
ExternalTypeOrdering
diametercode
M12PE-LS2PE1L02
M18PE-LS5PE1L05
M30PE-LS10PE1L10
12/24V DC110V AC220V AC
TypeOrderingTypeOrderingTypeOrdering
This lamp is used to indicate the
operating state of output 1. (Lights up
when the output is ON. Goes out when
the output is OFF)
Operating indicator (Red)
This lamp is used to indicate the
operating state of output 2. (Lights up
when the output is ON. Goes out when
the output is OFF)
Adjusting
dial
Method of
adjusting
Method I
Method II
–
Connect voltmeter to
terminal 1 and 8
ShieldOutput 1
65 43
78 12
Output 2
+
-
V
PE-LA M0
–
1V
Position the standard size
target to the position at a
point 1/5th of the rated
operating distance and
turn the 1V adjusting dial
clockwise slowly (to
increase the output
voltage) or
counterclockwise so that
the output voltage is 1V.
Position the standard size
target at a point 1/5th of
the rated operating
distance and turn the 1V
adjusting dial
counterclockwise so that
the SPAN indicator goes
out, and then turn it
clockwise slowly until the
SPAN indicator lamp lights
up.
5V
Position the standard size
target to the position at the
rated operating distance
and turn the 5V adjusting
dial clockwise slowly (to
increase the output
voltage) or
counterclockwise so that
the output voltage is 5V.
Position the standard size
target to the position at the
rated operating distance
and turn the 5V adjusting
dial clockwise slowly so
that the SPAN indicator
goes out, and then turn it
counterclockwise until the
SPAN indicator lamp lights
up.
Adjustment of sensitivity
Position of
target
Adjusting
dial
S
SPAN indicator (Green)
Lights up when the linear output voltage
is within the range from 1 to 5 Volts.
05/42
Method of
adjusting
Position the standard size target in position and turn the
detecting distance adjusting dial clockwise slowly until the
operation indicator lights up. Move the standard size target so
as to check that it operates at the specified position.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
The lineup of PE2-C series proximity
switches has been augmented by the
addition DC 3-wire system switches with
NPN and PNP transistor outputs and 2wire system switches usable for both AC
and DC applications.
These new switches are characterized
by:
• A stable operating indicator composed
of a two-color (red and green) LED that
enables easy and reliable setting of
detection range
• Smaller dimensions and longer
detecting distance due to incorporation
of new IC
• Four ways to configure DC 2-wire
systems, DC 3-wire systems (which
provide NPN and PNP transistor
outputs) and two-wire systems usable
for both AC and DC applications. This
wide choice of configurations makes it
possible to choose appropriate switch
for the circuit.
The DC 2-wire system
• Reduces wiring cost and labor
• Can be connected to such high
impedance load as small relays, PLC,
and NC equipment without risk of reset
failure due to leakage currents of not
exceeding 0.8mA and a residual
voltage of 3V.
• Consumes very little current and
places no burden on the power supply
serving PLC.
Make a power supply for the sensor
unnecessary.
• Enables easy connection on site to
load equipment having sink- and
source-current input specifications.
• Has protective circuit to protect against
short-circuit, reverse polarity, and
surges.
The DC 3-wire system:
• Available in 16 types of units, shielded
or unshielded, of varying diameter, and
providing two types of output
• Also available with PNP output
transistors for European machine tool
applications.
PE2-C
AF91-505
• Has the same external dimensions as
the PE1 series which is not equipped
with stable operating indicator.
The 2-wire system switch usable for both
AC and DC applications:
• Can be operated from sources from 20
to 250V DC and 40 to 250V AC.
• Reduces wiring cost and labor.
• Is unpolarized, eliminating hazard of
reverse polarity connection.
Ambient temperature–25 to 80°C (no icing)
Differential distanceMax. ±10% of operating distance
Variation due toMax. ±10% of operating distance at 20°C within a temperature range of –25 to 70°C
temperature fluctuation
Variation due toMax. ±2% of operating distance at rated voltage when operated within ±15% of power supply voltage
voltage fluctuation
Current consumption—25mA max. (at 24V DC)—
Leakage current0.8mA max. (at 24V DC)—0.8mA max. (at 24V DC),
Residual voltage3V max. (at 100mA)1.5V max. (at 24V DC, 200mA)6V max. (DC), 10V max. (AC)
Dielectric strength1000V AC, 1 minute
Insulation resistance50MΩ or more (500V DC megger)
Degree of protectionIP67 (IEC Standards)
Vibration10–55Hz, 1.5mm double amplitude (in X, Y, Z direction respectively for 2 hours)
Shock500m/s
Circuit protectionShort-circuit, reverse polarity, surge voltageSurge voltage
when using two switches with oscillation
frequencies different from each other.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
05/46
■ Ordering information
Specify the following:
1. Type number or ordering code
Information subject to change without notice
Page 50
Proximity Switches
PE-X3D
Inductive proximity switches–Flat
type, PE-X3D
Easy-to-mount thin inductive type
proximity switches
Operating system:
DC supply/3-wire system
Operating distance: 3mm
■ Specifications
Type (Ordering code)
Operating system
Output
Operating distance
Target size
Differential distance
Power supply voltage
Operating voltage range
Current consumption
Switching capacity
Residual voltage
Response frequency
Ambient temperature
Humidity
Circuit protection
Variation due to temperature
fluctuation
Variation due to voltage
fluctuation
Dielectric strength
Insulation resistance
Degree of protection
Vibration
Shock
■ Response curve for iron
Target 12 x 12 x 1 mm, Iron
Y (mm)
3
X
Y
2
1
1234566543210
PE-X3D (PE1X03-D)
DC supply/3-wire
NPN transistor, current output, 1NO
3mm ±10%
12 × 12 × 1mm (iron)
Max. ±10% of operating distance
12/24V DC
10 to 30V DC
15mA max. at 24V DC
100mA max.
1.5V max. at 24V DC 100mA
50Hz or more
–25 to +70°C (no icing)
35 to 95% RH
Surge voltage, reverse polarity
Max. ±10% of operating distance at 20°C within temperature
range of –25 to +70°C
Max. ±1% of operating distance at 12/24V DC when operated
within 85% to 115% of power supply voltage
1000V AC, 1 min.
50M⏲ (500V DC)
IP66 (IEC Standard)
10–55Hz, 1.5mm double amplitude
2
500m/s
X (mm)
■ Features
• A mere 7mm height
• Only two screws are needed to affix
each switch, eliminating the need for
exclusive mounting brackets
• Incorporates a stable operating level
indicator
• Equipped with surge suppression
circuits and protection circuits against
reverse polarity
■ Material of target–Operating
distance
3
2
1
Operating distance (mm)
10020
Length of one side of target (mm)
Fe
Stainless
(SUS304)
Brass
Al
Cu
30
40
PE-X3D
AF92-374
■ Wiring diagram
Brown
Load
Proximity
switch
Black
Blue
10-30V
DC
■ Dimensions, mm
Indicator
IV cable
0.14mm
ø3
1000
2
Mass: 20g
Sensor
surface
5
137
1.5
13.5
0.5
30
ø3.2
2.5
10
ø6.4
2.5
■ Mutual interference
Be sure to space two switches at a
distance greater than that shown in the
figure below to prevent mutual
interference.
50mm50mm
■ Ordering information
Specify the following:
1.Type number or ordering code
05
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/47
Page 51
Proximity Switches
A
B
PE-G4D
Inductive proximity switches–
Square type, PE-G4D
Operating system:
DC supply/3-wire system
Supply voltage range: 10 to 30V DC
Operating distance: 4mm
■ Specifications
Type (Ordering code)
Operating system
Output
Operating distance
Target size (iron)
Differential distance
Rated voltage
Switching capacity
Current consumption
Residual voltage
Response frequency
Variation due to voltage
fluctuation
Variation due to temperature
fluctuation
Dielectric strength
Insulation resistance
Degree of protection
Ambient temperature
Humidity
Vibration
Shock
■ Wiring diagrams
Proximity
switch
PE-G4D (PE1G04-D)
DC supply/3-wire
1NO
4mm ±10%
20×20×1mm
Max. ±10% of operating distance
12/24V DC (10 to 30V DC)
50mA max.
15mA max. at 24V DC
1.5V max. at 50mA
200Hz
Max. ±1% of operating distance at 12/24V DC when
operated within 10 to 30V DC
Max. ±10% of operating distance at 20°C within
temperature range of –25 to +70°C
2000V AC, 1min.
50M⏲ or more (500V DC)
IP67 (IEC)
–25 to +70°C (no icing)
35 to 95% RH
10–55Hz, 1.5mm double amplitude
500m/s
Brown
Load
Black
Blue
■ Features
• Degree of protection meets the
requirements of IEC IP67, thus
permitting operations in unfavorable
environment.
• Only two screws are needed to affix
each switch, eliminating the need for
exclusive mounting brackets.
• Incorporates surge suppression
circuits and protection circuits against
reverse polarity and short-circuits.
2
■ Dimensions, mm
24.5
Indicator2-ø3.3
10-30V
DC
17
17
PE-G4D
AF90-849
■ Response curve for iron
Target 20 x 20 x 1mm, Iron
Y (mm)
4
X
Y
50 5
3
2
1
X (mm)
■ Mutual interference
Be sure to space two switches at a
distance greater than that shown in the
figure below to prevent mutual
interference.
Type
PE-G4D
A (mm)
60
B (mm)
60
■ Ordering information
Specify the following:
1.Type number or ordering code
28
2000
10.5
ø4
Mass: 40g
05/48
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 52
Magnetically operated reed
X
Y
Y(mm)
160
120
80
40
OFF
ON
040408080120120160
X(mm)-X(mm)
PM–2S +PM–10M
PM–2SH+PM–10MH
M
Sw
switches, PM
Standard type
Operating distance: Maximum 35, 70,
120mm
Reed switch:1NO, 2 Amps
■ Features
• Power source not required
• Comprises sensing magnetic element
and reed switch
• Resin molded construction
• Water- and dust-tight, shock-resistant
• Breaking capacity: 0.5Amps at 220V
AC
• Operating distance is longer than
oscillating type.
Differential5 – 15mm5 – 20mm15 – 40mm
Ambient temperature–20° to +130°C–20° to +130°C–20° to +130°C
PM2S, PM-2SH read switches
Rated operating voltage: 220V AC, DC (Max.)
Rated operating current: 0.5A (Max.)
Make and break capacity: 50W DC, 50VA AC (Max.)
Mechanical: durability 100 million operations
Electrical:2 million operations at 200V AC 0.125A
Insulation resistance: Over 100MΩ at 500V DC
Dielectric strength:700V AC rms. 1 minute (Contact to contact)
Ambient temperature: –10 to +65°C (For 130°C use is also available)
1 meter lead wires are normally provided.
M
Y
Sw
X
1.4 million operations at 100V AC 0.25A
PM–2S +PM–4M
PM–2SH–PM–4MH
Y(mm)
80
60
40
20
OFF
ON
PM
X-806
05
X(mm)-X(mm)
010102020303040
X(mm)-X(mm)
020204040606080
PM-2SPM-2SPM-2S
■ Dimensions, mm
PM-2S Mass: 210g
PM-2SH
81
95
High temperature type
ø8.2
IV Cable
0.75mm
1000
ø10
ø6
Standard type
35
21
20
Notes: • Reed switch and magnetic element are mounted on anti-magnetic material. The operating distance will be decreased when mounted on magnetized
materials.
• Both reed switch and magnetic element cannot be used in over 5-gauss magnetic fields.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
PM-2M Mass: 170g
PM-2MH
ø4.7
2
R2.5
PM-4M Mass: 440g
PM-4MH
5
35
19
50
60
40
25
19
110
125
95
PM-10MMass: 1300g
PM-10MH
6
39
19
25
19
170
186
146
7
42
21
50.5
20
05/49
Page 53
Proximity Switches
Magnetically operated reed switches - slot type
PM1U
Magnetically operated reed switches–Slot type
PM1U
■ Features
• Stable switch operation is ensured by inserting the object for
detection 35mm into the switch slot.
Ideal for detecting the position of a ferromagnetic-material
plate passing in the switch slot.
• Magnetically operated switch using a sealed contact is never
affected by electrical noise, ensuring highly reliable detection.
• The built-in permanent magnet enables switching of both AC
and DC signals without using a power supply.
• Models with an output indicator are also available.
• Our advanced design assures superior environmental
protection complying with IP67 (IEC).
■ Ordering information
Specify the following:
1. Type number (ordering code)
PM1U
KK02-304A
■ Specifications
OperatingDetectingHysteresisContactOutputTypeMeasurement conditions for an operating
slot widthdistance*arrangementindicator(=Ordering code) position and hysteresis
25mm+4 ±6mm10mm (Max.) 1NONotPM1U-25ALF
(ON: Detected) provided
ProvidedPM1U-25ALF2
0
X
–4 ±6mm7mm (Max.) 1NCNotPM1U25BLF
(OFF: Detected)
provided
ProvidedPM1U-25BLF2
Note *: The detecting distance and hysteresis are defined in the standard detecting conditions shown above.
35
magnet
Permanent
(Object insertion length)
ZZ
Reference object for detection
SPCC60(W)×100(H)×t1.6)
Reed switch
TypePM1U-25ALFPM1U-25ALF2PM1U-25BLFPM1U-25BLF2
Output indicatorNot providedProvidedNot providedPovided
Operating slot width25mm
Object insertion length35mm (Min.)
Rated operating voltage220V AC, DC (Max.)
Rated operating current0.2A (Max.)
Make and break current0.2A (Max.)
OFF ➝ ON response time2ms (Max.)
ON ➝ OFF response time0.5ms (Max.)
Life expectancy (Mechanical)1×107 operations (Min.)
Life expectancy (Electrical)2×106 operations (Min.) Load: Miniature control relay HH54P 220V AC/7mA
1×107 operations (Min.) Load: Resistance (12V DC/0.2A)
Ambient temperature–10 to +65°C
Humidity45 to 95%HR
Vibration resistance10 to 55Hz, 1.5mm peak-to peak amplitude, 2-hour for each of X, Y, and Z axes
Shock resistance300m/s2, three-time for each of X, Y, and Z axis
Output resistance at ON6Ω (Max.)–6Ω (Max.)–
Switch residual voltage at ON–4V (Max.)–4V (Max.)
Insulation resistance100MΩ (Min.)
Degree of protectionIP67 (IEC standard)
Maximum signal cable length300m
Note: The LED indicator becomes dark when the load current is 10mA or less. (Switches with an output indicator)
1 meter lead wire is provided.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
05/50
Information subject to change without notice
Detecting distance
Object moving direction
Hysteresis
Reset distance
Object moving direction
Y
0
Page 54
■ Object detection area (Examples)
40
25
38
Counter-bore for M6 nut
(7mm-deep)
6mm-dia., 0.5mm
2
PVC pair cable (1m)
Output indicator
29
67
3
52
7
46
ø6.2
30
(60)
Embedded metal with inside threads for M6 screw
(10mm-deep)
PM1U-25APM1U-25B
Object to be detected
-5
-10
10
0
-5
SPCC 100×60×t1.6
1055
Y
60
Detecting position
Reset position
X(mm)
Y(mm)
-10
X
0
10
20
30
40
50
Z(mm)
Object to be detected
SPCC 100×60×t1.6
Y(mm)
1050-5-10
Y
60
Detecting position
Reset position
-10
Y(mm)
X
10
-5
-5
-10
0
Object to be detected
SPCC 100×60×t1.6
Detecting position
Reset position
1055
Y
60
X(mm)
Proximity Switches
PM1U
Object to be detected
SPCC 100×60×t1.6
0
10
20
30
40
50
1050-5-10
Z(mm)
Y
60
Y(mm)
Detecting position
Reset position
35
Note: The X - Y characteristics are
symmetrical to the X axis.
■ Wiring diagrams
100
Z
Note: The Y - Z characteristics are
symmetrical to the Z axis.
100
35
Note: The X - Y characteristics are
symmetrical to the X axis.
100
Z
Note: The Y - Z characteristics are
symmetrical to the Z axis.
100
05
Switch with no output indicatorsSwitch with an output indicator
Brown
Load
Reed switch
Power
supply
Blue
LED (Red)
Brown
Load
Reed switch
Power
supply
+
–
Blue
Note: When using a DC power supply, connect the brown
terminal to (+) and blue terminal to (0V).
Otherwise, the indicator will not go on.
■ Operation chart■ Dimensions, mm
PM1U-25A쏔
Object to be detected
Reed switch
LED output indicator
PM1U-25B쏔
Object to be detected
Reed switch
LED output indicator
Present
Not present
OFF
Not lit
Present
Not present
OFF
Not lit
ON
ON
Lit
Lit
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/51
Page 55
Proximity Switches
AC, DC
Load
AES
502L
Magnetically operated reed switches
AES
Magnetically operated reed switches
AES
Small size
Operating distance: Max. 20, 27mm
Reed switch:1NO
Rated thermal current: 2.5A (AES402)
2.5A (AES502)
AEQ010-1A
■ Features
• Power source is not required.
AES402 is small size, soldering
terminal.
AES502 is provided with lead wire.
• Epoxy resin molded, shock-resistant.
• Make and break capacity:
Max. 50VA, 50W (AES402)
Max. 50VA, 50W (AES502)
• Operating voltage:
Max. 220V AC, DC (AES402)
Max. 220V AC, DC (AES502)
■ Ordering information
Specify the following:
1. Type number or ordering code
■ Specifications
TypeContact
Ordering code Contact PM2BPM2D
Contact1NO
Operating distance14–20mm20–27mm
Differential1–12mm1–14mm
Repeat accuracy0.5mm or less
Ambient temperature–20°C to +80°C
Dielectric strength
Between open contacts 700V AC, 1 min.350V AC, 1 min.
Terminal to ground1500V AC, 1 min.1500V AC, 1 min.
Insulation resistance100MΩ or more100MΩ or more
LifeMechanical 10 million operations
expectancy
AES402B-1A
FA-1446
Magnet
AES402B-1A
AEQ010-1A
AES502L-3A
AEQ020-1T
Magnet PM34PM35
at 500V DCat 500V DC
Electrical2 million2 million
operations atoperations at
100V AC 3.3VA100V AC 3.3VA
AEQ020-1T
SB-131
AES502L-3A
■ Response curves
Short axis
Contact: AES402B-1A
Magnet AEQ010-1A
AEQ010
X
Y
AES402
35
Contact: AES502L-3A
Magnet AEQ020-1T
X
Y
AES502L
05/52
25 20 15 10 5 530
AEQ020
■ Dimensions, mm
AES402B-1AAEQ010-1A
14.2
20.6
4.5
4.1
Y [mm]
30
OFF
OFF
ON
ON
20
15
10
5
0
Y
[mm]
40
30
20
10
01010203040503020
353025201510
X [mm]
40
50
X
[mm]
25.4
49.2
AES502L-3A
2-ø5.5
■ Wiring
AES402B-1AAES502L-3A
ø4.1
17.5
2
IV cable
0.5mm
ø7.2
23
52
62
14
15
9
Load
AC, DC
33
25.4
40.6
AEQ020-1T
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
• The operating distance will be decreased when mounted
on ferromagnetic material such as iron.
• Both reed switch and magnetic elements can not be
used in over 5-Gauss magnetic fields.
Information subject to change without notice
Page 56
Proximity Switches
Magnetically operated reed switches
AER
Magnetically operated reed switches
AER
Operating distance: 4.0–5.5mm (at 1NO)
Reed switch:1NO or 1NC
■ Construction
Silicon tube
Permanent magnet
Reed switch
Rated thermal current: 2.5A
■ Features
• Sensing magnetic element and reed
switch element are integrated in an
epoxy molded housing.
• Power source is not required.
• Travelling direction of the metal object
is not limited.
• Make and break capacity:
Case
Packing
Wires
Epoxy resin
molded
Max. 50VA AC, 50W DC
• Operating voltage: Max. 220V AC, DC
• Water- and dust-tight
Notes: • The operating distance will be decreased
when mounted on ferromagnetic material
such as iron.
• This switch cannot be used in over
5-Gauss magnetic fields.
• Keep a distance of over 100mm from
other limit switches.
■ Specifications
Type (Ordering code)AER201L-1A (PM1A)AER211L-1A (PM1B)
Contact arrangement1NO1NC
Rated voltage AC, DC220 max.220V max.
Rated thermal current2.5A2.5A
Make and break currentMax. 0.5A AC, DCMax. 0.5A AC, DC
Operating distance4.0–5.5mm3.5–5.0mm
Differential1–5.5mm1–5.5mm
Repeat accuracyLess than 0.5mmLess than 0.5mm
Ambient temperature–20° to +80°C–20° to +80°C
Dielectric strength350V AC rms. 1 minute (Between open contacts)
1500V AC rms. 1 minute (Terminal to ground)
Insulation resistanceOver 100MΩ at 500V DC
Life expectancyMechanical10 million operations
Electrical2 million operations at 100V AC 3.3VA (Inductive)
2 million operations at 100V DC 1.6W (Inductive)
10 million operations at 12V DC 6W (Resistive)
Notes: • 1 meter lead wires are normally provided.
• The standard detected object is iron plate of 50 × 50 × 2 (mm). If the object is smaller, the operating
distance is reduced.
AER201L-1A
■ Response curves
AER20 Short axis
AER20 Long axis
AER21 Short axis
Y
Y
Y
Target
2 × 50 × 50 mm Iron
X
Target
2 × 50 × 50 mm Iron
X
Target
2 × 50 × 50 mm Iron
X
FA1445
05
■ Wiring
Load
AC, DC
■ Dimensions, mm
6.5
■ Ordering information
Specify the following:
1.Type number or ordering code
1000
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
48.6
4122
24
31
3.5
ø7.2
2
0.5mm
Mass: 100g
AER21 Long axis
Y
Target
2 × 50 × 50 mm Iron
X
05/53
Page 57
Photoelectric Switches
General information
Selection guide
Basic type
Photo
Description
Detecting method
Operation mode
Special function
PH1C
Highly compact photoelectric switch with dimensions of
10.8x31x20mm.
Energy saving design with long-distance detection and a
built-in amplifier.
Meets CE Mark requirements.
Transmission type
Retroreflective type
Diffuse reflection type
Dark-ON/Light-ON selectable
–
XX03-013A
Supply voltage
Output configuration
Output
(switching capacity)
Detectable object
(material)
Detecting distance
Response time
Ambient temperature
Degree of protection
Page
12 to 24VDC ± 10% (ripple ± 10% or less)
Detecting:
NPN transistor, open collector output
100mA max.
Transparent, opaque
1m, 3m, 4m, 10m
1ms
Operation: –25 to +55°C
Storage:–40 to +70°C
IP67 (IEC)
05/56
■ Detecting method
Transmission typeRefroreflective typeDiffuse reflection type
Light sourceReceiver
Light source/
receiver
Reflector
Light source/
receiver
05/54
Object
ObjectObject
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 58
Photoelectric Switches
General information
Basic type
Photo
Description
Detecting method
Operation mode
Special function
Supply voltage
Output configuration
PH4C
XX03-002AKK02-303A
AC/DC dual supply voltage.
Highly compact with dimensions of 18 x 50 x 50mm.
Retroreflective type equipped with mirror surface rejeciton
function
Transmission type
Retroreflective type
Diffuse reflection type
Dark-ON or Light-ON
–
24 to 240V AC±10%
12 to 240V DC±10%
Relay output
(ripple ±10% or less)
PH8AU
Slot-type photoelectric switches ideal for conveyor
applications, such as elevators and multi-level parking lifts.
Same mounting method as our slot-type magnetically
operated reed switches (type PM1U).
Slot type
Dark-ON or Light-ON
–
10 to 30V DC
NPN transistor, open collector output
05
Output
(switching capacity)
Detectable object
(material)
Detecting distance
Response time
Ambient temperature
Degree of protection
Page
■ Operation mode
Dark-ON
(operates when light
is interrupted)
Light-ON
(operates when light
is incident)
3A max. (250V AC res. load)
10mA max. (5V DC)
Transparent, opaque
30cm, 2.5m, 3.5m, 4m, 5m
30ms max.
Operation: –25 to +55°C
Storage: –30 to +70°C
IP64 (IEC)
05/61
Transmission typeRetroreflective typeDiffuse reflection typeSlot type
–
Opaque
30mm
1ms or less
Operation: -25 to +55°C
Storage: -30 to +70°C
IP66 (IEC)
05/65
without object
with object
without object
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/55
Page 59
Photoelectric Switches
PH1C
Photoelectric switches with built-in amplifier
PH1C
■ Features
• Highly compact with dimensions of 10.8 x 31 x 20mm
• Energy-saving design
• Covers a wide range of detection with distances of 10m
(transmission type), 3 or 4m (retroreflective type), or 1m
(diffuse reflection type)
• Retroreflective type equipped with mirror surface rejection
function
• High-speed response time of 1ms
• Light-ON/Dark-ON selectable with operation mode switch
• Equipped with various protective functions
• High degree of protection of IP67 (IEC) enables use even in
environments where exposure to water is possible.
• Improved alignment (±2.5˚) of optical and mechanical axes
simplifies adjustment (transmission type, retroreflective type)
• Environment-friendly lead-free solder used
• Meets CE Mark requirements.
XX03-014A,15A
Transmission type
PH1CT
XX03-013AXX03-007A
Retroreflective type
PH1CR
Diffuse reflection type
PH1CD
Reflector
PH1X
■ Types
Detecting methodDetectingLightOutput Output
distanceemitting operation
elementmode
Transmission type10mRed LED NPN Dark-ON /
Light sourceReceiver
Object
Retroreflective type 0.1 to 3m Red LED
(with mirror surface rejection ) (using PH1X-R1)
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 60
Photoelectric Switches
PH1C
■ Ratings and specifications
Detection methodTransmission typeRetroreflective type (with mirror Diffuse reflection type
surface rejection)
TypePH1CT-M1DCPH1CR-3MDCPH1CD-1MDC
Light emitting elementRed LEDInfrared LED
Supply voltage12 to 24V DC ±10% (ripple ±10% or less)
Current consumptionLight source: 15mA, Receiver: 20mA 30mA max.
Detecting distance10m0.1 to 3m (using PH1X-R1)1m (white mat paper 30 x 30cm)
0.1 to 4m (using PH1X-R1S)
Detectable targetOpaque 12mm dia. min.Opaque 75mm dia. min.Transparent or opaque
Directional angleLight source and receiver: 3 to 15°Light source/receiver: 2 to 10°,–
eachReflector: 30°
Differential–Max.
Detecting outputNPN transistor, open collector output
Load current: 100mA max. (26.4V DC)
Residual voltage: 1V DC max. at load current less than 10mA
2V DC max. at load current of 10 to 100mA
Output operation modeDark-ON / Light-ON selectable
Response time1ms max. (operation/reset)
Indicator Operation indicatorOrange LED (Light source: power Orange LEDOrange LED
supply indicator)
Stability levelGreen LED (Receiver)Green LEDGreen LED
indicator
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
2-M3
25.410.1
22.8
1.2
Page 62
Photoelectric Switches
■ Characteristic curve, typical
Receiver output-Distance
PH1CT-M1DCPH1CR-3MDC + ReflectorPH1CD-1MDC
100
70
50
30
10
7
5
3
Receiver output allowance
(times)
1
0.7
0.5
0.3
Operating level
0.1
010203040506070
Distance (m)
100
70
50
30
10
7
5
3
Receiver output allowance
(times)
1
0.7
0.5
0.3
Operating level
0.1
0246810
PH1X-R1
PH1X-R1S
Distance (m)
100
Detecting target: White mat paper 30×30cm
70
50
30
10
7
5
3
Receiver output allowance
(times)
1
0.7
0.5
0.3
Operating level
0.1
00.511.52.523
PH1C
Distance (m)
Setting range of light source and receiver head
PH1CT-M1DC
600
400
Distance Y (mm)
200
0
200
400
600
1020304050
Y
X
Distance X
(m)
Size of detecting target - Distance
PH1CD-1MDC
4.5
d
4
d
3.5
Distance Y (m)
3
2.5
2
1.5
1
0.5
SUS (glossy)
White mat paper
Black carbon paper
35302520151050
Target size d (cm)
PH1CT-M1DC + SlitPH1CR-3MDC + Reflector
200
150
100
Distance Y (mm)
50
0
50
100
150
200
Operating range
PH1CD-1MDC
50
40
Black carbon paper
30
20
Distance Y (mm)
10
0
10
20
30
White mat paper
40
50
Y
X
123456
PH1X-SP
PH1X-S2
0.5 11.522.53 3.5
PH1X-S1
Y
X
SUS (glossy)
Distance X
(m)
Distance
X (m)
200
150
100
Distance Y (mm)
50
0
246810
50
100
150
200
PH1X-R1S
PH1X-R1
■ Wiring diagrams
PH1CT receiver, PH1CR, PH1CD
Operation indicator
(Orange)
Stability level indicator
(Green)
PH1CT light source
Power supply
indicator
(Orange)
PH main
circuit
PH main
circuit
Y
X
Distance X
(m)
12 to 24V DC
Brown
Load
Black
100mA or less
Blue
12 to 24V DC
Brown
Blue
05
0V
0V
■ Timing diagrams
"Light-ON" mode (switch: L side) "Dark-ON" mode (switch: D side)
Light is incident
Light is interrupted
Operatiion
indicator (Orange)
Output transistor
Load (Relay)
ON
OFF
ON
OFF
ON
OFF
(Brown-Black)
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Light is incident
Light is interrupted
Operatiion
indicator (Orange)
Output transistor
Load (Relay)
ON
OFF
ON
OFF
ON
OFF
(Brown-Black)
05/59
Page 63
Photoelectric Switches
PH1C
■ Indicator
Operation indicator (Ope)
Lights when the switch is activated (output transistor ON) irrespective of Light-ON, Dark-ON.
Stability level indicator (Stab)
Lights when the incident light or shaded light is good enough for stable level.
Status of incident lightIndicatorAllowanceStab
Light-ONDark-ON
Stable incidentStable shade
(green)
ON
Ope
(orange)
ON
Operation level ×1.11
Unstable incidentUnstable shade
OFF
ON
Operation level
Unstable shadeUnstable incident
OFF
OFF
Operation level ×0.86
Stable shade
ON
OFFStable incident
■ Optical axis adjustment
Transmission type
Swinging the light source and receiver up and down and right
and left when no objects exist, set and fix the light source and
receiver to the center within the range where the operation
indicator (orange) is lit or is turned off (Dark-ON). At the same
time make sure that the stability level indicator (green) is lit.
Retroreflective type
Swinging the unit and reflector up and down and right and left
when no objects exist, set and fix the unit and reflector to the
center within the range where the operation indicator (orange) is
lit or is turned off (Dark-ON). At the same time make sure that
the stability level indicator (green) is lit.
■ Sensitivity adjustment
When carrying a normal detection, set the sensitivity adjuster at the maximum sensitivity value by turning it fully clockwise.
Sensitivity adjustment is necessary for the following cases.
• Transmission type: To detect translucent or minute objects
• Reflection type: To detect objects with inadequate contrast
Carry out the sensitivity adjustment as follows. (When excessive power is added to the sensitivity adjuster, it might be damaged.)
StepState of detected objectOperation indicator and
sensitivity adjuster
Transmission typeReflection type
1
2
3
Note: lit, not lit
Detected object
Background object
Light-ONDark-ON
A
Min.Max.
B
Min.Max.
set
A
Min.Max.
B
A
Min.Max.
B
Min.Max.
set
AB
Min.Max.
Step
By turning the sensitivity adjuster,
obtain point A and B at that the status
of the operation indicator changes.
Unless the status changed, two points
at finishing turning the sensitivity
adjuster will be point A or B.
An intermediate position between point
A and B will be the optimum position.
05/60
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 64
Photoelectric switches with AC/DC input PH4C
■Features
• Highly compact with dimensions of 18 x 50 x 50mm
• Accepts a wide range of supply voltage with AC/DC dual
input
• Retroreflective type has a wider range of detecting distance.
3.5m for PH4CR-2HR, 5m for PH4CR-4MR (using a
separately-sold reflector PH1X-R1S)
• Retroreflective type equipped with mirror surface rejection
function
• Meets CE Mark requirements
Transmission type
PH4CT
Diffuse reflection type
PH4CD
XX03-003AXX03-002A
XX03-001A
Photoelectric Switches
PH4C
Retroreflective type
PH4CR
XX03-007A
Reflector
PH1X-R1S
■Types
Detecting methodDetectingLightOutput Operation
distanceemitting mode
element
Transmission type5mInfrared Relay Light-ON
Light sourceReceiver
Object
Retroreflective type Without mirror0.1 to 4m Red LEDLight-ON
Light
source/receiver
Diffuse reflection type30cmInfraredLight-ON
Light source/receiver
Note: * The distances in ( ) are the values where a separately-sold reflector PH1X-R1S is used.
Reflector
RH1X
Object
surface rejection(0.1 to 5m)*
With mirror surface0.1 to 2.5m Light-ON
rejection(0.1 to 3.5m)*
Object
LEDoutput
(SPDT)
Dark-ON
LED
Dark-ON
Dark-ON
Dark-ON
Type
PH4CT-5MRA
PH4CT-5MRB
PH4CR-4MRA
PH4CR-4MRB
PH4CR-2HRA
PH4CR-2HRB
PH4CD-3CRA
PH4CD-3CRB
Supplied item
Cable length
Light source and 2m
receiver
Light source and 2m
receiver
Light source/ 2m
receiver
Light source/ 2m
receiver
Light source/ 2m
receiver
05
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/61
Page 65
Photoelectric Switches
PH4C
■ Ratings and specifications
Detection method Transmission typeRetroreflective type Diffuse reflection type
Without mirror surface With mirror surface
rejectionrejection
Dark-ON PH4CT-5MRBPH4CR-4MRBPH4CR-2HRBPH4CD-3CRB
Light emitting elementInfrared LEDRed LEDInfrared LED
Supply voltage24 to 240V AC ±10% 50/60Hz, 12 to 240V DC ±10% (ripple ±10% or less)
Current consumption3W max.2W max.
Detecting distance5m0.1 to 4m0.1 to 2.5m30cm
Detectable targetOpaque 14.8mm dia. min. Opaque 75mm dia. min.Transparent or opaque
Directional angleLight source andLight source/receiver: 1 to 5˚, Reflector: 40˚–
receiver: 3 to 20˚ each
Differential–Max. 20% of detecting
Detecting outputContact output: 250V AC 3A (cos ø =1), 5V DC 10mA
Relay durabilityMechanical 50 millions operations (at 18,000 operations/hour)
Electrical100,000 operations (at 1,800 operations/hour)
Response time30ms max. (operation/reset)
IndicatorRed LED (on when light is incident) Power supply indicator for light source
ConnectionAttached cable (2m, 0.3mm
Sensitivity adjustment–Dial type
Ambient operating illumination Incandescent lamp: 3,000 lx max. (at receiving surface)
Ambient temperatureOperating: –25 to +55˚C (no icing), storage: –30 to +70˚C
Ambient humidityOperating: 45 to 85%RH (no condensation), storage: 35 to 95%RH
Degree of protectionIP64 (IEC)
Insulation resistance20MΩ (500V DC megger)
Dielectric strength1,500V AC 50/60Hz for 1min
Vibration10 to 55Hz, 1.5mm double amplitude (2 hours for each X, Y, Z direction)
Shock500m/s
MaterialCasingAcrylonitrile butadiene styrene resin (ABS)
LensMethacrylic resin (PMMA)
MassApprox. 420gApprox. 250gApprox. 250g
Accessory (supplied)Mounting bracket (PH4X-P1), reflector PH1X-R1 (only for retroreflective type)
Note: * Reflector PH1X-R1 is supplied, PH1X-R1S is sold separately.
2
(3 times for each X, Y, Z direction)
(using PH1X-R1) *(usingPH1X-R1) *(white mat paper 10x10cm)
0.1 to 5m0.1 to 3.5m
(using PH1X-R1S) *(using PH1X-R1S) *
distance
2
)
■ Type number nomenclature Ordering information
Specify the following
1. Type number
Information subject to change without notice
Basic type
PH : Photoelectric switch
Series
4C : with AC/DC supply voltage
Detecting method
T: Transmission type
R : Retroreflective type
D : Diffuse reflection type
Detecting distance
3C : 30cm
2H : 2.5m
4M : 4m
5M : 5m
05/62
PH 4C T-5M R A
Operatoin mode
A : Light-ON
B : Dark-ON
Output
R : Relay output
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Page 66
Photoelectric Switches
PH4C
■ Dimensions, mm
PH4CT, PH4CR, PH4CD
PH4CT
Lens ø
21.5
14.8
36.5
2
Optical
axis
18
Indicator *
13.4
1
A *
28
50
Mounting bracket
*1 Mounting bracket can be fit on the side "A" too.
2
Power supply indicator for light source, incident light indicator for receiver
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 68
Photoelectric Switches
PH8AU
Slot-type photoelectric switches
PH8AU
■ Description
Slot-type photoelectric switches ideal for
conveyer application, such as elevators
and multi-level parking lifts.
The emitter and receiver are constructed
as a single unit, eliminating the need to
adjust the optical axis or sensitivity.
Same mounting method as our slot-type
magnefically operated reed switches
(type PM1U).
■ Specifications
Type
Operating distance (slot width)
Detectable object
Light emitting element
Supply voltage
Current consumption
Detecting output
Response time
Indicator
Connection
Ambient operating illumination
Ambient temperature
• Protective structure conforms to IP66
(IEC standards), so the product can be
used safely in environments with water
droplets.
• High speed response time of 1ms.
• Wide supply operating voltage range
from 10 to 30V DC.
PH8AU
PH8AU-30DALFPH8AU-30DBLF
30mm
Opaque, over 6mm diameter
Infrared LED
10 to 30V DC (Peak must be within this range)
45mA or less
(NPN) transistor open collector output, load current
Dark-ONLight-ON
1ms or less
Output indicator (Red LED)
1m attached cable
Incandescent lamp: 3000 lx or less, sun light: 10000 lx or less at receiving surface
Operating: -25 to +55°C
Storage: -30 to 70°C (no icing)
Operating: 35 to 85%RH
Storage: 35 to 95%RH
IP66 (IEC)
20MΩ min. (500V DC Megger)
1000V AC 50/60Hz 1 minute
10 to 55Hz, 1.5mm double amplitude (X, Y, Z direction respectively 2 hours)
500m/s2 three times for each of three directions X, Y and Z
Reverse connection and surge voltage
PC
PPS
KK02-303A
05
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
05/65
Page 69
Photoelectric Switches
PH8AU
■ Wiring diagrams■ Dimensions, mm
Incident
Brown
light
indicator
Photoelectric
Black
switch main
circuit
Blue
■ Type number nomenclature
PH8A U-30 D A LF
Basic type
Detecting method
U: Slot type
Detecting distance
30: 30mm
Load
30
Power supply
10 to 30V DC
30
52
67
3
30
40
62
Mass 150g
Cable length
LF: 1m
Operation
A: Dark-ON
B: Light-ON
Power supply and output
D: DC supply, NPN transistor open collector output
M6
M6
depth 10mm
Indicator
6.5
IV cable
3-wire, 0.3mm
12
2
Center of lens
12
14
ø6
■ Ordering information
Specify the following:
1. Type number (ordering code)
1000
05/66
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Page 70
Catalog Disclaimer
The information contained in this catalog does not constitute an express or implied warranty of quality, any warranty of
merchantability of tness for a particular purpose is hereby disclaimed.
Since the user's product information, specic use application, and conditions of use are all outside of Fuji Electric FA
Components & Systems'control,
products mentioned for the user's application.
One Year Limited Warranty
The products identied in this catalog shall be sold pursuant to the terms and conditions identied in the
"Conditions of Sale" issued by Fuji Electric FA with each order conrmation.
Except to the extent otherwise provided for in the Conditions of Sale issued by Fuji Electric FA, Fuji Electric FA
warrants that the Fuji Electric FA products identied in this catalog shall be free from signicant defects in materials
and workmanship provided the product has not been: 1) repaired or altered by others than Fuji Electric FA; 2) subjected
to negligence, accident, misuse, or damage by circumstances beyond Fuji Electric FA's control; 3) improperly operated,
maintained or stored; or 4) used in other than normal use or service. This warranty shall apply only to defects appearing
within one (1) year from the date of shipment by Fuji Electric FA, and in such case, only if such defects are reported
to Fuji Electric FA within thirty (30) days of discovery by purchaser. Such notice should be submitted in writing to Fuji
Electric FA at 5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo, Japan. The sole and exclusive remedy with respected to
the above warranty whether such claim is based on warranty, contract, negligence, strict liability or any other theory,
is limited to the repair or replacement of such product or, at Fuji Electric FA's option reimbursement by Fuji Electric
FA of the purchase price paid to Fuji Electric FA for the particular product.
representations or warranties, whether oral or in writing, expressed or implied, including but not limited to any
warranty regarding merchantability or fitness for a particular purpose.
Sale, no agent or representative of Fuji Electric FA is authorized to modify the terms of this warranty in writing or orally.
In no event shall Fuji Electric FA be liable for special, indirect or consequential damages, including but not limited to,
loss of use of the product, other equipment, plant and power system which is installed with the product, loss of prots
or revenues, cost of capital, or claims against the purchaser or user of the product by its customers resulting from
the use of information, recommendations and descriptions contained herein. The purchaser agrees to pass on to its
customers and users, in writing at the time inquiries and orders are received by buyer, Fuji Electric FA's warranty as set
forth above.
it shall be the responsibility of the user to determine the suitability of any of the
Fuji Electric FA does not make any other
Except as provided in the Conditions of
Caution "Safety precautions"
• Operate (keep) in the environment specied in the operating instructions and manual. High temperature, high
humidity, condensation, dust, corrosive gases, oil, organic solvents, excessive vibration or shock might cause electric
shock, re, erratic operation or failure.
• Follow the regulations of industrial wastes when the product is to be discarded.
• The products covered in this catalogs have not been designed or manufactured for use in equipment or systems
which, in the event of failure, can lead to loss of human life.
• If you intend to use the products covered in this catalog for special applications, such as for nuclear energy control,
aerospace, medical, or transportation, please consult our Fuji Electric FA agent.
• Be sure to provide protective measures when using the product covered in these catalogs in equipment which, in the
event of failure, may lead to loss of human life or other grave results.
• Follow the directions of the operating instructions when mounting the product.
Page 71
D&C CATALOG DIGEST INDEX
Individual
catalog No.
LOW VOLTAGE PRODUCTS Up to 600 Volts
01
02
03
04
05
06
07
08
09
10
Magnetic Contactors and Starters
Thermal Overload Relays, Solid-state Contactors
Manual Motor Starters and Contactors
Combination Starters
Industrial Relays, Industrial Control Relays
Annunciator Relay Unit, Time Delay Relays
Pushbuttons, Selector Switches, Pilot Lights
Rotary Switches, Cam Type Selector Switches
Panel Switches, Terminal Blocks, Testing Terminals