JQ RELAYS
VDE
HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY
mm inch
20
.787
10
.394
15.6
.614
FEATURES
• High electrical noise immunity
• High switching capacity in a compact package
• High sensitivity: 200 mW (1a), 400 mW (1c)
• High surge voltage: 8,000 V between contacts and coil
• UL, CSA, VDE, TÜV, SEMKO approved
• Class B coil insulation type available
SPECIFICATIONS
Contact
Expected electrical life (min. operations)
Coil (at 20°C 68°F)
Characteristics
Remarks
* Specifications will vary with foreign standards certification ratings. *
1
Measurement at same location as "Initial breakdown voltage" section *2Detection current: 10 mA *3Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *
4
Excluding contact bounce time *5Measured conditions
*
6
Half-wave pulse of sine wave: 11ms; detection time: 10µs *7Half-wave pulse of sine wave: 6ms *8Detection time: 10µs *
9
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24). *
10
When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F
with 20°C 68°F as a reference) and use a coil impressed voltage that is within
the maximum allowable voltage range.
Standard type High capacity type
Arrangement 1 Form A, 1 Form C
Initial contact resistance, max. (By voltage drop 6 V DC 1 A)
100 m
Contact material Silver alloy
Rating
(resistive)
Nominal switching capacity
1a
5 A 125 V AC 2 A 250 V AC
5 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
1c
N.O.
5 A 125 V AC 2 A 250 V AC
3 A 30 V AC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
N.C.
2 A 125 V AC 1 A 250 V AC
1 A 30 V DC
3 A 125 V AC 2 A 250 V AC
1 A 30 V DC
Max. switching power
1a 625 VA, 150 W 1,250 VA, 150 W
1c
N.O. 625 VA, 90 W 1,250 V AC, 150 W N.C. 250 VA, 30 W 500 V AC, 30 W
Max. switching voltage
250 V AC, 110 V DC (0.3A)
Max. switching current
N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A
Expected mechanical life (at 180 cpm)(min. operations)
10
7
Type Switching capacity No. of operations
Standard type
1a
5 A 125 V AC 3 A 125 V AC 2 A 250 V AC
5 A 30 V DC
5×10
4
2×10
5
2×10
5
10
5
1c
N.O.
5 A 125 V AC 2 A 250 V AC
3 A 30 V DC
5×10
4
2×10
5
10
5
N.C.
2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
2×10
5
2×10
5
10
5
High capacity type
1a
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5×10
4
5×10
4
10
5
1c
N.O.
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5×10
4
5×10
4
10
5
N.C.
3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
2×10
5
2×10
5
10
5
Nominal operating power 1a: 200 mW 1c: 400 mW
Max. operating speed 20 cpm Initial insulation resistance*
1
Min. 1,000 MΩ at 500 V DC
Initial breakdown voltage*
2
Between open contacts
1a: 1,000 Vrms for 1 min.
1c: 750 Vrms for 1 min.
Between contacts and coil
4,000 Vrms for 1 min.
Surge voltage between contact and coil*
3
8,000 V
Operate time*4 (at nominal voltage) Approx. 5 ms Release time*
4
(at nominal voltage)(without diode)
Approx. 2 ms
Temperature rise*
5
Max. 45°C
Shock resistance
Functional*
6
Min. 294 m/s2 {30 G}
Destructive*
7
Min. 980 m/s2 {100 G}
Vibration resistance
Functional*
8
98 m/s2 {10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
Destructive
117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2.0 mm
Conditions for operation, transport and storage*
9
(Not freezing and condens­ing at low temperature)
Ambient temp.*
10
–40°C to +85°C
–40°F to +185°F
Humidity 5 to 85% R.H.
Unit weight Approx. 7 g .25 oz
Standard type
Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70°C 158°F
High capacity type
Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70°C 158°F
Page 2
JQ
72
TYPES AND COIL DATA at 20°C 68°F
Part No.
Nominal
voltage, V DC
Pick-up
voltage, V DC
(min.)
Drop-out
voltage, V DC
(min.)
Nominal
operating
current, mA
Nominal
operating
power, mW
Coil resistance,
Ω (±
10%)
Max. allowable
voltage, V DC
1 Form A
Standard type
JQ1a-5V 5 3.75 0.25 40
200
125
180% of
nominal voltage
(at 20°C 68°F)
JQ1a-6V 6 4.5 0.3 33.3 180 JQ1a-9V 9 6.75 0.45 22.2 405 JQ1a-12V 12 9 0.6 16.7 720 JQ1a-18V 18 13.5 0.9 11.1 1,620 JQ1a-24V 24 18 1.2 8.3 2,880
High capacity type
JQ1aP-5V 5 4 0.25 40
200
125
130% of nominal voltage (at 85°C 185°F)
JQ1aP-6V 6 4.8 0.3 33.3 180 JQ1aP-9V 9 7.2 0.45 22.2 405 JQ1aP-12V 12 9.6 0.6 16.7 720 JQ1aP-18V 18 14.4 0.9 11.1 1,620 JQ1aP-24V 24 19.2 1.2 8.3 2,880
1 Form C
Standard type
JQ1-5V 5 3.75 0.25 80
400
62.5
150% of nominal voltage
(at 20°C 68°F)
JQ1-6V 6 4.5 0.3 66.7 90 JQ1-9V 9 6.75 0.45 44.4 202.5 JQ1-12V 12 9 0.6 33.3 360 JQ1-18V 18 13.5 0.9 22.2 810 JQ1-24V 24 18 1.2 16.7 1,440 JQ1-48V 48 36 2.4 8.3 5,760
High capacity type
JQ1P-5V 5 4 0.25 80
400
62.5
110% of nominal voltage (at 85°C 185°F)
JQ1P-6V 6 4.8 0.3 66.7 90 JQ1P-9V 9 7.2 0.45 44.4 202.5 JQ1P-12V 12 9.6 0.6 33.3 360 JQ1P-18V 18 14.4 0.9 22.2 810 JQ1P-24V 24 19.2 1.2 16.7 1,440 JQ1P-48V 48 38.4 2.4 8.3 5,760
TYPICAL APPLICATIONS
• Air conditioners
• Refrigerators
• Microwave ovens
• Heaters
ORDERING INFORMATION
Contact
arrangement 1a: 1 Form A
1: 1 Form C
Nil: Standard P: High capacity
5, 6, 9, 12, 18, 24, 48* V
Contact capacity
Nil: Class E coil insulation B: Class B coil insulation
Coil insulation class Coil voltage (DC)
UL/CSA, VDE, SEMKO approved type is standard. * Available only for 1 Form C type
1a P BEx. JQ 12 V
Page 3
JQ
73
REFERENCE DATA
Max. switching capacity (1 Form A type) Max. switching capacity (1 Form C type)
AC resistive load (High capacity type)
AC resistive load (Standard type)
1
10 100 277 1,000
10
100
5
Contact voltage, V
Contact current, A
1
10 100 277 1,000
10
100
2
3
5
Contact voltage, V
Contact current, A
AC resistive load (High capacity type) N.O. side
AC resistive load (High capacity type) N.C. side
AC resistive load (Standard type) N.O. side
AC resistive load (Standard type) N.C. side
Standard type
1-(1). Operate & release time (1 Form A type)
Tested sample: JQ1a-12V, 25 pcs.
1-(2). Operate & release time (1 Form C type)
Tested sample: JQ1-24V, 25 pcs.
2. Life curve
Ambient temperature: room temperature
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Max. Max.
Min. Min.
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min. Min.
Max. Max.
100
10
1
102345
Contact current, A
125V AC resistive load
250V AC resistive load
Life, ×10
4
DIMENSIONS
mm inch
1 Form A
1 Form C
Dimension
: General tolerance
Max. 1mm .039 inch
±
0.2 ±.008 1 to 5mm .039 to .118 inch±0.3 ±.012 Min. 5mm .118 inch
±
0.4 ±.016
20
.787
15.6
.614
4.2
.165
0.4
.016
10.16
.400
7.62
.300
7.62
.300
7.62
.300
10
.394
0.3
.012
0.3
.012
0.5 dia.
.020 dia.
0.8
.031
4.2
.165
0.4
.016
20
.787
15.6
.614
10.16
.400
5.08
.200
2.54
.100
7.62
.300
7.62
.300
0.3
.012
0.3
.012
0.3
.012
0.5 dia.
.020 dia.
0.8
.031
10
.394
Schematic (Bottom view)
1 Form A 1 Form C
Coil
COM N.O.
Coil
COM N.O.
N.C.
PC board pattern (Copper-side view)
1 Form A 1FormC
Tolerance: ±0.1 ±.004
4-1.3 dia.
4-.051 dia.
7.62
.300
7.62
.300
10.16
.400
5-1.3 dia.
5-.051 dia.
7.62
.300
7.62
.300
10.16
.400
Page 4
JQ
74
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 3 A, 5 A Measured portion: Inside the coil
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 3 A, 5 A Measured portion: Inside the coil
100 110 120 130 140 160 190180170150
10
20
30
40
50
0
Coil applied voltage, %V
Temperature rise, °C
3 A at 85°C
5 A at 85°C
3 A at 70°C
5 A at 70°C
100 110 120 130 140 160150
10
20
30
40
50
60
70
0
Coil applied voltage, %V
Temperature rise, °C
3 A at 70°C
5 A at 70°C
5 A at 85°C
3 A at 85°C
4-(1). Ambient temperature characteristics (1 Form A type)
Tested sample: JQ1a-24V Contact carrying current: 3 A, 5 A
4-(2). Ambient temperature characteristics (1 Form C type)
Tested sample: JQ1-24V Contact carrying current: 3 A, 5 A
1
Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 3 A)
2
Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 5 A)
3
Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 3 A)
4
Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 5 A)
5
Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A)
6
Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 3 A)
7
Pick-up voltage
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
5
6
4
7
3
2
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
3
4
5
7
6
2
High capacity type
1-(1). Operate & release time (1 Form A type)
Tested sample: JQ1aP-12V, 25 pcs.
1-(2). Operate & release time (1 Form C type)
Tested sample: JQ1P-12V, 25 pcs.
2. Life curve
Ambient temperature: room temperature
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min. Min.
Max. Max.
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min. Min.
Max. Max.
100
10
1
2046810
Contact current, A
125V AC resistive load
250V AC resistive load
Life, ×10
4
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 5 A, 10 A Measured portion: Inside the coil
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 5 A, 10 A Measured portion: Inside the coil
100 120 140 160 180
10
20
30
40
50
60
70
0
Coil applied voltage, %V
Temperature rise, °C
10 A at 70°C
10 A at 85°C
5 A at 70°C
5 A at 85°C
Coil applied voltage, %V
Temperature rise, °C
100 110 120 130 140 150 160
10
20
30
40
50
60
70
0
10 A at 70°C
10 A at 85°C
5 A at 70°C
5 A at 85°C
Page 5
JQ
75
4-(1). Ambient temperature characteristics (1 Form A type)
Tested sample: JQ1aP-24V Contact carrying current: 5 A, 10 A
4-(2). Ambient temperature characteristics (1 Form C type)
Tested sample: JQ1P-24V Contact carrying current: 5 A, 10 A
1
Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 5 A)
2
Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 10 A)
3
Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 5 A)
4
Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 10 A)
5
Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 10 A)
6
Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A)
7
Pick-up voltage
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
5
4
7
6
3
2
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
5
7
6
2
3
4
For Cautions for Use, see Relay Technical Information (Page 11 to 39).