Datasheet JH2a-L2-DC6V, JH2a-L2-DC48V, JH2a-L2-DC24V, JH2a-L2-DC12V, JH1a-L2-DC48V Datasheet (NAIS)

...
Page 1
116
JH RELAYS
30 AMP PO WER RELAY WITH SPACE SAVING DESIGN
VDE
mm inch
33
1.299
35.8
1.409
56
2.205
FEATURES
• Many safety-oriented characteristics incorporated
Contact gap: more than 3 mm .118 inch
for 1 Form A and 2 Form A
Breakdown voltage for N.O. contact:
2,000 V AC between contacts 5,000 V AC between coil and contact
Molded materials: all 94 V-0
• Various contact arrangements
1 Form A, 2 Form A, 3 Form A, 2 Form A 1 Form B
• High dielectric strength for transient protection
10,000 V surge is ms between coil and contact
• High inrush resistance
1 Form A type: 117 A (meets TV -8 requirement) 2 Form A type: 91 A (meets TV -6 requirement)
VDE, TÜV also approved
SPECIFICATIONS
Contact
Coil
Characteristics
Arrangement 1 Form A 2 Form A 3 Form A 2 Form A 1 Form B Initial contact pressure Approx. 80 g (2.82 oz) Approx. 40 g (1.41 oz) Approx. 30 g (1.06 oz) N.O.: 30 g (1.06 oz); N.C.: 20 g (0.71 oz) Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 m
Contact material Silver alloy
Rating (resistive load)
Nominal switching rating 30 A 250 V AC 20 A 250 V AC 15 A 250 V AC N.O.: 15 A 250 V AC; N.C.: 5 A 250 V AC Max. switching power 7,500 VA 5,000 VA 3,750 VA N.O.: 3,750 VA; N.C.: 1,250 VA Max. switching voltage 250 V AC Max. switching current 30 A 20 A 15 A N.O.: 15 A; N.C.: 5 A
Expected life (min. operations)
Mechanical (at 180 cpm) 5
×
106 (106 for latching and AC types)
Electrical (at nominal resistive load) (at 20 cpm)
10
5
Minimum operating power 1.23 W (DC) Nominal operating power 1.92 W (DC)
Contact arrangement 1 Form A 2 Form A 3 Form A 2 Form A 1 Form B Maximum operating speed 20 cpm Initial insulation resistance*
1
Min. 100 mΩ at 500 V DC
Initial breakdown voltage
Between open contacts 2,000 Vrms N.O.: 2,000 Vrms; N.C.: 1,500 Vrms Between contact sets 4,000 Vrms 3,000 Vrms 2,000 Vrms Between contacts and coil 5,000 Vrms N.O.: 5,000 Vrms; N.C.: 3,000 Vrms
Surge voltage*
2
More than 10,000 V between contacts and coil
Temperature rise (at nominal voltage) DC: Max. 65
°
C; AC: Max. 85°C
Operate time*
3
Approx. 20 ms at nominal voltage (DC)
Release time (without diode)*
3
Approx. 5 ms at nominal voltage (DC)
Shock resistance Functional: min. 98 m/s
2
{10 G}; Destructive: min. 980 m/s2 {100 G}
Functional: Approx. 49 m/s
2
{5 G}
Destructive: min. 980 m/s
2
{100 G} Vibration resistance Functional: 10 to 55Hz at 1 mm double amplitude Destructive: 10 to 55 Hz at 1.5 mm double amplitude Conditions for operation,
transport and storage*
4
(Not freezing and condens­ing at low temperature)
Ambient temp. –50°C to +55°C (–58°F to +131°F) Humidity 5 to 85% R.H.
Air pressure 86 to 106 kPa
Molded materials used 94 V-0 Unit weight
Approx. 90 g 3.17 oz
(Approx. 115 g 4.06 oz)
Approx. 96 g 3.39 oz
(Approx. 129 g 4.55 oz)
Approx. 100 g 3.53 oz
(Approx. 130 g 4.59 oz) ( ): screw type
Remarks
* Specifications will vary with foreign standards certification ratings. *1Measurement of same location as "Initial breakdown voltage" section *2 Wave is standard shock voltage of ±1.2 × 50 µs according to JEC-212-1981
*
3
Excluding contact bounce time
*4Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
Page 2
JH
117
TYPICAL APPLICATIONS
Air conditioners, microwave ovens, load management equipment, copiers, pro­cess control equipment.
ORDERING INFORMATION
2a L2 DC24VEx. JH
Contact arrangement
1a: 1 Form A 2a: 2 Form A 3a: 3 Form A 2a1b: 2 Form A 1 Form B
Nil: Plug-in terminal type
DC 6, 12, 24, 48, 110 V
Nil: Single side stable for 3 Form A,
W: 2 Form A 1 Form B
L2: 2 coil latching for 1 Form A, 2 Form A WL2: 2 coil latching for 3 Form A,
2 Form A 1 From B
Terminals Operating function
(Notes) 1. For UL/CSA recognized type, please add suffix UL/CSA.
(Notse) 2. Standard Packing: Carton 20 pcs, Case 100 pcs.
Coil voltage
TYPES AND COIL DATA
Single side stable (DC coils at 20°C 68°F): DC types of JH3a-W and JH2a1b-W
2 coil latching (DC coils only at 20°C 68°F): DC types of JH1a-L2, JH2a-L2 and JH3a-WL2
Nominal voltage,
V DC
Pick-up voltage Drop-out voltage
Maximum allowable
voltage, at 50°C
Coil resistance (ohm)
Nominal operating
power, (W)
6
Less than 80% of
nominal voltage
More than 10% of
nominal voltage
110% of
nominal voltage
18.7 1.92 12 75 1.92 24 300 1.92 48 1,200 1.92
110 6,300 1.92
Nominal voltage,
V DC
Set and reset voltage
Maximum allowable
voltage, at 50°C
Coil resistance, (Ω) Nominal operating power, (W)
Coil I Coil II Coil I Coil II
6
Less than 80% of
nominal voltage
110% of
nominal voltage
18.7 18.7 1.92 1.92 12 75 75 1.92 1.92 24 300 300 1.92 1.92 48 1,200 1,200 1.92 1.92
110 6,300 6,300 1.92 1.92
Notes:
1. Coil resistance varies ±10% for less than 1,000 W, and ±15% for more than 1,000 Ω. For each ±1°C change in ambi­ent temperature, coil resistance varies
±
0.4%.
2. For each ±1°C change in ambient tem­perature, pick-up and drop-out voltages vary approximately ±0.4%.
3. Pic k-up and drop-out voltages are mea­sured with the relay mounted as follows.
4. The coil operating current should be pure direct current in principle. When rec­tified alternating current is applied to the coil, the relay characteristics (pick-up, drop-out voltage) may be changed due to the ripple factor. Confirmation of the char­acteristics in the actual circuit is suggest­ed.
Page 3
JH
118
DIMENSIONS
Plug-in type
1 Form A (JH1a-L2)
33
1.299
R4
.157
10.4
.409
0.8
.031
35
1.378
50
1.969
22
.886
40 1.575
36.4
1.433
14
5786
0.8
.031
6.35
.250
3.5
.138
FASTON No. 250
8.4
.331
10.25
.404
2 DIA. 4.5
2 DIA. .177
Schematic (Bottom view)
Panel cutout
1
4
578
6
++
SET
RESET
2-DIA. 4.5±0.1
2-DIA. .177±.004
40±0.1
1.575±.004
mm inch
2 Form A (JH2a-L2)
12 34
5786
33
1.299
R4
.157
10.4
.409
0.8
.031
35
1.378
50
1.969
22
.886
40 1.575
36.4
1.433
14.4
.567
0.8
.031
6.35
.250
3.5
.138
FASTON No. 250
8.4
.331
10.25
.404
2 DIA. 4.5
2 DIA. .177
Schematic (Bottom view)
Panel cutout
12 34
578
6
++
SET
RESET
Schematic (Bottom view)
2-DIA. 4.5±0.1
2-DIA. .177±.004
40±0.1
1.575±.004
3 Form A (JH3a-W, JH3a-WL2)
Single side stable 2 coil latching
33
1.299
R4
.157
129 103 4
56
R2.25
.089
40 1.575
10.55
.415
3.5
.138
6.35
.250
0.8
.031
10.25
.404
47.6
1.874
36
1.417
9
.354
9
.354
9
.354
56
2.205
10.4
.409
0.8
.031
35
1.378
FASTON No. 250
33
1.299
R4
.157
9
.354
10.4
.409
9
.354
9
.354
0.8
.031
35
1.378
47.6
1.874
36
1.417
129 1034
5786
40 1.575
56
2.205
0.8
.031
R2.25
.089
6.35
.250
3.5
.138
FASTON No. 250
10.55
.415
10.25
.404
Schematic (Bottom view)
Single side stable
2 coil latching
Panel cutout
1291034
5
6
1291034
578
6
SET
RESET
++
2-DIA. 4.5±0.1
2-DIA. .177±.004
40±0.1
1.575±.004
(47.6±0.1)
(1.874±.004)
2 Form A 1 Form B (JH2a1b-W)
Single side stable
33
1.299
R4
.157
R2.25
.089
129 1034
56
40 1.575
10.55
.415
3.5
.138
0.8
.031
6.35
.250
10.25
.404
36
1.417
47.6
1.874
10.4
.409
9
.354
9
.354
9
.354
0.8
.031
FASTON No. 250
56
2.205
35
1.378
Note: 2 coil latching types of 2 Form A 1 Form B
contact arrangement are not available.
Schematic (Bottom view)
Panel cutout
1291034
5
6
2-DIA. 4.5±0.1
2-DIA. .177±.004
40±0.1
1.575±.004
(47.6±0.1)
(1.874±.004)
Page 4
JH
119
REFERENCE DATA
1 Form A
1. Maximum switching power 2. Life curve 3.-1 Contact temperature rise (DC type)
30 20
10
5
1
0.5
300 100 500
Contact voltage, V
Contact current, A
AC resistive load
DC resistive load
250 V AC 30 V DC cosϕ=1.0
Contact current, A
Life, ×10
4
100
50
5
5 1015202530350
10
80
50
70
40
60
30
80 90 110100 130120 140 150
40A
20 10
0
20A
30A
10A
Coil applied voltage, %V
Temperature rise, °C
Measured portion: Contacts Ambient temperature: 25°C
3.-2 Coil temperature rise (DC type)
80
50
90
70
40
60
30
80 90 110100 130120 140 150
40A 10A
0A
20
0
30A 20A
Coil applied voltage, %V
Temperature rise, °C
Contact carrying
current
2 Form A
1. Maximum switching power 2. Life curve
20 10
5
1
0.5
300 100 500250
Contact voltage, V
Contact current, A
AC resistive load
DC resistive load
100
50
5
5 1015202530350
10
250 V AC 30 V DC cosϕ=1.0
Contact current, A
Life, ×10
4
3.-1 Contact temperature rise (DC type) 3.-2 Coil temperature rise (DC type)
80
50
70
40
60
30
80 90 110100 130120 140 150
20 10
0
30A
20A
10A
Coil applied voltage, %V
Temperature rise, °C
Measured portion: Contacts Ambient temperature: 25°C
80
50
90
70
40
60
30
80 90 110100 130120 140 150
0A
10A
20
0
30A 20A
Coil applied voltage, %V
Temperature rise, °C
Measured portion: Inside of coil Ambient temperature: 25°C
Contact carrying
current
3 Form A
1. Contact temperature rise (DC type) 2. Coil temperature rise (DC type)
Coil applied voltage, %V
Temperature rise, deg.
80 100 120
0
10
20
30
40
50
Measured portion: Contacts Ambient temperature: 20°C
0 A
10 A
20 A
Coil applied voltage, %V
Temperature rise, deg.
80 100 120
0
20
30
40
50
60
70
Measured portion: Inside of coil Ambient temperature: 20°C
0 A
10 A
20 A
Page 5
JH
120
MOUNTING METHOD
1. Plug-in terminal type 2. Allo wab le installation wiring size f or ter­minal blocks
Due to the UP terminals, it is possible to either directly connect the wires or use crimped terminal
M4 screw
Faston No.250
Washer
1a type 2.6 mm or 5.5 mm
2
2a type 2.0 mm or 3.5 mm
2
3a type 1.6 mm or 2 mm
2
NOTES
1. The dust cover should not be removed
since doing so may alter the characteris­tics.
2. Avoid use under severe environmental
conditions, such as high humidity , organic gas or in dust, oily locations and locations subjected to extremely frequent shock or vibrations.
3. When mounting, use spring washers.
Optimum fastening torque ranges from 5 kg to 7 kg·cm 4.5 to 6 pounds·inch.
4. Firmly insert the receptacles so that
there is no slack or looseness. To remo v e a receptacle, 2 to 4 kg of pulling strength is required. Do not remo ve more than one receptacle at one time.Always remove
one receptacle at a time and pull it straight outwards.
5. Install the rela y so that it lies in direction A (up-down direction). (Pick-up voltage and drop-out voltage values are those when installed in direction A.)
6. When using the AC type, the operate time due to the in-rush phase is 20 ms or more. Theref ore, it is necessary for you to verify the characteristics for your actual circuit. Moreover, the release time for the NC side of the 2a1b type requires the same verification.
7. Since the JH rela y latching model is po­larized, be sure to follow the instructions in the wiring diagrams when wiring the +
and - coils. Mistaken wiring will lead to in­correct operation and failures. Short the negative side no. 6 and no . 8 set and reset terminals.
8. When using the push-on blocks for the screw terminal type, use crimped termi­nals and tighten the screw-down termi­nals to the torque listed below.
M4.5 screw
147 N·cm to 166.6 N·cm (15 to 17kg·cm)
M4 screw
117.6 N·cm to 137 N·cm (12 to 14 kg·cm)
M3.5 screw
78.4 N·cm to 98 N·cm (8 to 10kg·cm)
For Cautions for Use, see Relay Technical Information (Page 11 to 39). JH RELAY ACCESSORIES
Terminal socket instantly attachable to DIN rail
TYPES
SPECIFICATIONS
* Don't insert or remove relays while in the energized condition.
Part No. Applicable relays JH1-L2-SF JH1a-L2 JH2-L2-SF JH2a-L2 JH3-SF JH3a and 2a1b JH3-L2-SF JH3a-WL2
Types JH1, JH2 JH3 Maximum continuous
current*
20 A 250 V AC
(1a: 30 A 250 V AC)
15 A 250 V AC
Breakdown voltage 2,000 Vrms between terminals Insulation resistance More than 1,000 MΩ between poles Heat resistance 150°C±3°C for 1 hour
DIMENSIONS
1 Form A, 2 Form A
10.25
.404
8.4
.331
4
.157
60
2.362
22
.866
9
.354
6 8
7 5
1 2
3 4
9
.354
11
.433
16
.630
23
.906
14.4
.567
11
.433
34
1.339
70
2.756
Relay mounting diagram
61
2.402
Panel cutout
40
1.575
2-DIA. 4.2
.165
(2-M4 Screw hole)
(.157)
[Notes] The above diagrams show 2 Form A 2 coil latching type Terminals 2, 3 and 8 excluded for 1 Form A 2 coil latching type
mm inch
Page 6
JH
121
3 Form A, 2 Form A 1 Form B
10.25
.404
10.5
.413
4
.157
66
2.369
27
1.063
9
.354
6 8
7 5
1 2 3
4 5 6
9
.354
9
.354
9
.354
9
.354
9
.354
9
.354
16
.630
22
.866
34
1.339
70
2.756
Relay mounting diagram
61
2.402
Panel cutout
2-DIA. 4.2
.165
(2-M4 Screw hole)
(.157)
40
1.575
(47.6)
(1.874)
[Note] Terminals 7 and 8 excluded for single side stable type
mm inch
MOUNTING METHOD
1. Relay mounting 2. Installing to a DIN rain 3. Removing from a DIN rain
Push
Flat-head screw driver
NOTES
1. Be careful not to drop the relay. It is made of heat-hardened resin and may break.
2. Be sure to tighten the screw-down ter­minals firmly . Loose terminals may lead to the generation of heat.
12/27/2002 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog
Loading...