Datasheet JCNEM24, JCNEF24 Specification

general characteristics
1
inserts in light technopolymer
tinned precision contacts
enclosures in die-cast aluminum alloy
vertical safety closing levers in zinc-plated steel
economical
JCNE inserts for multipole connectors
2
polarity: 6, 10, 16, 24 + m
rated current: 16A
rated voltage: 500V
EN 61984 (2001-11): 500V/6kV/3 - 400V/690V/6kV/2
screw terminal for conductors, section 0.5÷2.5 mm2- AWG 20÷14, with conductor protection plate
different sized steel screws
contact surface: tinned
UL V0 approved self-extinguishing thermoplastic material
JCNEF 06 - JCNEM 06 dimensions in mm polarity (contact side)
FM
44
M
F
27
FM
57
M
F
27
FM
77.5
M
F
27
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
13 14 15 16 17 18 19 20 21 22 23 24
FM
104
M
F
27
JCNEF 10 - JCNEM 10 dimensions in mm polarity (contact side)
JCNEF 16 - JCNEM 16 dimensions in mm polarity (contact side)
JCNEF 24 - JCNEM 24 dimensions in mm polarity (contact side)
JCNE inserts for multipole connectors
3
JCNE inserts - 16A - 500V/6kV/3
female inserts
JCNEF 06 06 poles +m
for enclosure size 44.27
10/100
JCNEF 10 10 poles +m
for enclosure size 57.27
5/80
JCNEF 16 16 poles +m
for enclosure size 77.27
5/80
JCNEF 24 24 poles +m
for enclosure size 104.27
5/80
male inserts
JCNEM 06 06 poles +m
for enclosure size 44.27
10/100
JCNEM 10 10 poles +m
for enclosure size 57.27
5/80
JCNEM 16 16 poles +m
for enclosure size 77.27
5/80
JCNEM 24 24 poles +m
for enclosure size 104.27
5/80
drawing ILME description package
part No.
Enclosure identification
Matching connector inserts with the correct enclosures can be complicated.
To simplify we have used the definition of “size” in addition to the product’s normal identification code.
From the figure to the left and the table below, this new variable refers to the fixing distance between screw centres which, is the same for inserts and enclosures, and clear.
All the pages illustrating inserts and enclo­sures bear the relevant identification refer­ences.
The table below sets out all the enclosure “sizes” and the dimension of the insert fixing slots.
enclosure slot for inserts with “size” fixing distance
identification x - y
“44.27” 44 x 27 mm
“57.27” 57 x 27 mm
“77.27” 77.5 x 27 mm
“104.27” 104 x 27 mm
JCV enclosures for multipole inserts
4
enclosures in aluminum alloy
painted with grey RAL 7040
enclosures JCVI / JCVP with two levers in zinc-plated steel
IP65 degree of protection in accordance with EN 60529
for inserts size 57.27, 77.27, 104.27
JCVI dimensions in mm
type AB CD
JCVI 10 122 95.5 65 83 JCVI 16 142.5 115.5 86 103 JCVI 24 169 142.5 112 130
B
58
A
45.5
6
29
Pg/M
4
Ø 5.5
D
58
type ABCD E F
JCVP 10 57 40 52 122 82 93.5 JCVP 16 63 45 57 142.5 105 117 JCVP 24 63 45 57 169 132 144
JCVP dimensions in mm
Pg/M
E
F
C
B
A
C
35
Ø 4.5
panel cut-out for bulkhead housings in mm
D
32
JCV enclosures for multipole inserts
5
bulkhead mounting housings with levers
may be combined with: hoods without gasket, with pegs for two levers
closing covers with pegs for two levers
CD CT CDD CQE CN-CNE CT CMSE CP CX MIXO JCNE
CTS CCE CTSE CMCE package
standard version (10A) CSE (16A)
JCVI 10
size 57.27
-- -- 42 18 10 10 3+2 -- 8/24 3* 10 5/40
JCVI 16
size 77.27
40 40 72 32 16 16 6+2 6 4* 16 5/40
JCVI 24
size 104.27
64 64 108 46 24 24 10+2 -- 4/8 6* 24 5/40
* = number of modules that may be mounted via frames
= CX 4/0, CX 4/2, CX 6/36, CX 12/2
Pg threading - wall-mounting housings with levers
may be combined with: hoods without gasket, with pegs for two levers
closing covers with pegs for two levers
CD CDD CQE CN-CNE CMSE CP CX MIXO JCNE
normal CCE CMCE package
standard version CSE
JCVP 10
size 57.27
- Pg 16 -- 42 18 10 3+2 -- 8/24 3* 10 5/20
JCVP 16
size 77.27
- Pg 21 40 72 32 16 6+2 6 4* 16 5/20
JCVP 24
size 104.27
- Pg 21 64 108 46 24 10+2 -- 4/8 6* 24 5/20 * = number of modules that may be mounted via frames
= CX 4/0, CX 4/2, CX 6/36, CX 12/2
- enclosures with metric threading upon request
- high enclosures upon request
- characteristics of other inserts, not belonging to the Jei series, in the CN catalogue
JCH enclosures for multipole inserts
6
enclosures in aluminum alloy
painted with grey RAL 7040
JCHO / JCHV enclosures with 4 pegs for 2-lever enclosures
IP65 degree of protection in accordance with EN 60529
for inserts size 57.27, 77.27, 104.27
JCHO dimensions in mm
JCHV dimensions in mm
Pg/M
43
A
type AB
JCHO 10 73 52 JCHO 16 93.5 63 JCHO 24 120 63
type ABC JCHV 10 73 45 58 JCHV 16 93.5 45 58 JCHV 24 120 55 69.5
B
Pg/M
43
A
B
C
JCH enclosures for multipole inserts
7
Pg threading - side entry hoods - with pegs
may be combined with: bulkhead or wall-mounting housings with two levers and gasket
hoods with two levers and gasket closing covers with two levers and gasket
CD CDD CQE CN-CNE CMSE CP CX MIXO JCNE
normal CCE CMCE package
standard version CSE
JCHO 10
size 57.27
- Pg 16 -- 42 18 10 3+2 -- 8/24 3* 10 100
JCHO 16
size 77.27
- Pg 21 40 72 32 16 6+2 6 4* 16 100
JCHO 24
size 104.27
- Pg 21 64 108 46 24 10+2 -- 4/8 6* 24 80 * = number of modules that may be mounted via frames
= CX 4/0, CX 4/2, CX 6/36, CX 12/2
- enclosures with metric threading upon request
- high enclosures upon request
- characteristics of other inserts, not belonging to the Jei series, in the CN catalogue
Pg threading - top entry hoods - with pegs
may be combined with: bulkhead or wall-mounting housings with two levers and gasket
hoods with two levers and gasket closing covers with two levers and gasket
CD CDD CQE CN-CNE CMSE CP CX MIXO JCNE
normal CCE CMCE package
standard version CSE
JCHV 10
size 57.27
- Pg 16 -- 42 18 10 3+2 -- 8/24 3* 10 100
JCHV 16
size 77.27
- Pg 21 40 72 32 16 6+2 6 4* 16 80
JCHV 24
size 104.27
- Pg 21 64 108 46 24 10+2 -- 4/8 6* 24 80 * = number of modules that may be mounted via frames
= CX 4/0, CX 4/2, CX 6/36, CX 12/2
- enclosures with metric threading upon request
- high enclosures upon request
- characteristics of other inserts, not belonging to the Jei series, in the CN catalogue
JCV enclosures for multipole inserts
8
enclosures in aluminum alloy
painted with grey RAL 7040
enclosures JCVI L / JCVP L with one lever in zinc-plated steel
IP65 degree of protection in accordance with EN 60529
for inserts size 44.27, 57.27, 77.27, 104.27
JCVI L dimensions in mm
type AB C D
JCVI 06 L 66 82.5 52 70 JCVI 10 L 70 95.5 65 83 JCVI 16 L 70 115.5 86 103 JCVI 24 L 70 142.5 112 130
type ABCD E F JCVP 06 L 53 40 52 70 70 82 JCVP 10 L 57 40 52 73 82 93.5 JCVP 16 L 63 45 57 75.5 105 117 JCVP 24 L 63 45 57 75.5 132 144
JCVP L dimensions in mm
B
Ø 5.5
A
45.5
29
6
B
4
C
E
F
Pg/M
Pg/M
D
A
C
35
Ø 4.5
panel cut-out for bulkhead housings in mm
D
32
JCV enclosures for multipole inserts
9
bulkhead mounting housings with single lever
may be combined with: hoods with pegs for one lever
closing covers with pegs for one lever
CD CT CDD CQE CN-CNE CT CMSE CP CX MIXO JCNE
CTS CCE CTSE CMCE package
standard version (10A) CSE (16A)
JCVI 06 L
size 44.27
-- -- 24 10 6 6 -- -- -- 2* 6 5/40
JCVI 10 L
size 57.27
-- -- 42 18 10 10 3+2 -- 8/24 3* 10 5/20
JCVI 16 L
size 77.27
40 40 72 32 16 16 6+2 6 4* 16 5/20
JCVI 24 L
size 104.27
64 64 108 46 24 24 10+2 -- 4/8 6* 24 5/20
* = number of modules that may be mounted via frames
= CX 4/0, CX 4/2, CX 6/36, CX 12/2
Pg threading - wall-mounting housings with single lever
may be combined with: hoods with pegs for one lever
closing covers with pegs for one lever
CD CDD CQE CN-CNE CMSE CP CX MIXO JCNE
CCE CMCE
package
standard version CSE
JCVP 06 L
size 44.27
- Pg 16 -- 24 10 6 -- -- -- 2* 6 5/20
JCVP 10 L
size 57.27
- Pg 16 -- 42 18 10 3+2 -- 8/24 3* 10 5/10
JCVP 16 L
size 77.27
- Pg 21 40 72 32 16 6+2 6 4* 16 5/10
JCVP 24 L
size 104.27
- Pg 21 64 108 46 24 10+2 -- 4/8 6* 24 5/10 * = number of modules that may be mounted via frames
= CX 4/0, CX 4/2, CX 6/36, CX 12/2
- enclosures with metric threading upon request
- high enclosures upon request
- characteristics of other inserts, not belonging to the Jei series, in the CN catalogue
JCV enclosures for multipole inserts
10
enclosures in aluminum alloy
painted with grey RAL 7040
JCVI LP / JCVP LP enclosures with one lever in zinc-plated steel and a cover in self-extinguishing thermoplastic material
IP65 degree of protection in accordance with EN 60529
for inserts size 44.27, 57.27, 77.27, 104.27
JCVI LP dimensions in mm
type ABCDEF
JCVP 06 LP 53 40 52 91 70 82 JCVP 10 LP 57 40 52 94 82 93.5 JCVP 16 LP 63 45 57 94 105 117 JCVP 24 LP 63 45 57 94 132 144
JCVP LP dimensions in mm
Ø 5.5
A
B
29
45.5 6
A
B C
E
F
Pg/M
Pg/M
D
4
type ABCD
JCVI 06 LP 82.5 89 52 70 JCVI 10 LP 95.5 94 65 83 JCVI 16 LP 115.5 94 86 103 JCVI 24 LP 142.5 94 112 130
C
35
Ø 4.5
panel cut-out for bulkhead housings in mm
D
32
JCV enclosures for multipole inserts
11
bulkhead mounting housings with lever and thermoplastic cover
may be combined with: hoods with pegs for one lever
CD CT CDD CQE CN-CNE CT CMSE CP CX MIXO JCNE
CTS CCE CTSE CMCE package
standard version (10A) CSE (16A)
JCVI 06 LP
size 44.27
-- -- 24 10 6 6 -- -- -- 2* 6 5/20
JCVI 10 LP
size 57.27
-- -- 42 18 10 10 3+2 -- 8/24 3* 10 5/20
JCVI 16 LP
size 77.27
40 40 72 32 16 16 6+
2
6 4* 16
5/20
JCVI 24 LP
size 104.27
64 64 108 46 24 24 10+2 -- 4/8 6* 24 5/20
* = number of modules that may be mounted via frames
= CX 4/0, CX 4/2, CX 6/36, CX 12/2
Pg threading - wall-mounting housings with lever and thermoplastic cover
may be combined with: hoods with pegs for one lever
CD CDD CQE CN-CNE CMSE CP CX MIXO JCNE
CCE CMCE package
standard version CSE
JCVP 06 LP
size 44.27
- Pg 16 -- 24 10 6 -- -- -- 2* 6 5/10
JCVP 10 LP
size 57.27
- Pg 16 -- 42 18 10 3+2 -- 8/24 3* 10 5/10
JCVP 16 LP
size 77.27
- Pg 21 40 72 32 16 6+
2
6 4* 16
5/10
JCVP 24 LP
size 104.27
- Pg 21 64 108 46 24 10+2 -- 4/8 6* 24 5/10 * = number of modules that may be mounted via frames
= CX 4/0, CX 4/2, CX 6/36, CX 12/2
- enclosures with metric threading upon request
- high enclosures upon request
- characteristics of other inserts, not belonging to the Jei series, in the CN catalogue
JCH enclosures for multipole inserts
12
enclosures in aluminum alloy
painted with grey RAL 7040
JCHO L / JCHV L enclosures with 2 pegs for 1-lever enclosures
IP65 degree of protection in accordance with EN 60529
for inserts size 44.27, 57.27, 77.27 104.27
JCHO L dimensions in mm
JCHV L dimensions in mm
Pg/M
43
A
type AB
JCHO 06 L16 60 47 JCHO 10 L 73 52 JCHO 16 L 93.5 63 JCHO 24 L 120 63
type ABC JCHV 06 L16 60 40 53 JCHV 10 L 73 45 58 JCHV 16 L 93.5 45 58 JCHV 24 L 120 55 69.5
B
Pg/M
43
A
B
C
JCH enclosures for multipole inserts
13
Pg threading - side entry hoods - with pegs
may be combined with: bulkhead or wall-mounting housings with lever
hoods with lever closing covers with lever
CD CDD CQE CN-CNE CMSE CP CX MIXO JCNE
normal CCE CMCE package
standard version CSE
JCHO 06 L16
size 44.27
- Pg 16 -- 24 10 6 -- -- -- 2* 6 100
JCHO 10 L
size 57.27
- Pg 16 -- 42 18 10 3+2 -- 8/24 3* 10 100
JCHO 16 L
size 77.27
- Pg 21 40 72 32 16 6+2 6 4* 16 100
JCHO 24 L
size 104.27
- Pg 21 64 108 46 24 10+2 -- 4/8 6* 24 80 * = number of modules that may be mounted via frames
= CX 4/0, CX 4/2, CX 6/36, CX 12/2
- enclosures with metric threading upon request
- high enclosures upon request
- characteristics of other inserts, not belonging to the Jei series, in the CN catalogue
Pg threading - top entry hoods - with pegs
may be combined with: bulkhead or wall-mounting housings with lever
hoods with lever closing covers with lever
CD CDD CQE CN-CNE CMSE CP CX MIXO JCNE
normal CCE CMCE package
standard version CSE
JCHV 06 L16
size 44.27
- Pg 16 -- 24 10 6 -- -- -- 2* 6 100
JCHV 10 L
size 57.27
- Pg 16 -- 42 18 10 3+2 -- 8/24 3* 10 100
JCHV 16 L
size 77.27
- Pg 21 40 72 32 16 6+2 6 4* 16 80
JCHV 24 L
size 104.27
- Pg 21 64 108 46 24 10+2 -- 4/8 6* 24 80 * = number of modules that may be mounted via frames
= CX 4/0, CX 4/2, CX 6/36, CX 12/2
- enclosures with metric threading upon request
- high enclosures upon request
- characteristics of other inserts, not belonging to the Jei series, in the CN catalogue
CR accessories for multipole connectors
14
code pins and guides
single pin - in steel - for 6 variants
CR 20 D for connector inserts 50
double pin - in steel - for 16 variants CRM D male - for connector inserts 50 CRF D female - for connector inserts 50
drawing ILME description package
part No.
1
4
2
3
5
8
6
7
9
12
10
11
13
16
14
15
1
423
5
867
9
1210 11
13
1614 15
3
4
1
2
5
6
9
10
7
8
11
12
13
14
15
16
application with double inserts
application with single insert
female code pin
(CRF D)
male code pin
(CRM D) + normal fixing screw M = male insert F = female insert
M
F
1
M
F
2
M
F
3
4
M
F
5
M
F
6
M
F
1
423
5
867
9
1210 11
1
2
3
4
5
6
1
423
5
867
9
1210 11
13
1614 15
3
M
M
F
F
4
M
M
F
F
1
M
M
F
F
2
M
M
F
F
5
M
M
F
F
6
M
M
F
F
3
4
1
2
5
6
7
8
application with double inserts
code pin (CR 20 D) + normal fixing screw M = male insert F = female insert
application with single insert
selection using single code pins selection using double code pins
M
M
M
M
M
F
F
F
F
F
M
F
M
F
M
F
M
F
M
F
M
F
M
F
M
F
M
F
M
F
M
F
M
M
M
M
M
M
M
M
F
M
M
M
M
M
M
M
M
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
Loading...