IS3052
OPTICALLY COUPLED RANDOM
PHASE NON-ZERO CROSSING
TRIAC DRIVERS
DESCRIPTION
The IS3052 is an optically coupled isolator
consisting of a Gallium Arsenide infrared emitting diode coupled with a light activated silicon
bilateral switch performing the functions of a
triac mounted in a standard 6 pin dual-in-line
package. The IS3052 provides random phase
control of high current triacs or thyristors. The
IS3052 features greatly enhanced static dv/dt
capability to ensure stable switching performance of inductive loads.
FEATURE
l Options :-
10mm lead spread - add G after part no.
Surface mount - add SM after part no.
Tape&reel - add SMT&R after part no.
l High Isolation Voltage (5.3kV
l 550V Peak Blocking Voltage
l All electrical parameters 100% tested
l Custom electrical selections available
RMS
,7.5kV
APPLICATIONS
l Solenoid / Valve Controls
l Lamp Ballasts
l Static AC Power Switch
l Interfacing Microprocessors to 115 and
240Vac Peripherals
l Solid State Relays
l Incandescent Lamp Dimmers
l Temperature Controls
l Motor Controls
PK
Dimensions in mm
1
2 5
3
0.5
1.2
3.0
0.5
7.62
6.62
2.54
7.0
6.0
4.0
3.0
3.35
ABSOLUTE MAXIMUM RATINGS
(25 °C unless otherwise noted)
)
Storage Temperature -400C - +1000C
Operating Temperature -400C - +850C
Lead Soldering Temperature 2600C
(1.6mm from case for 10 seconds)
Input-to-output Isolation Voltage (Pk) 7500 Vac
(60 Hz , 1sec. duration)
INPUT DIODE
Forward Current 60mA
Reverse Voltage 3V
Power Dissipation 100mW
(derate linearly 1.33mW/0C above 250C)
OUTPUT PHOTO TRIAC
6
4
7.62
13°
Max
0.26
OPTION SM
SURFACE MOUNT
0.6
0.1
10.46
9.86
1.25
0.75
OPTION G
7.62
0.26
10.16
ISOCOM COMPONENTS LTD
Unit 25B, Park View Road West,
Park View Industrial Estate, Brenda Road
Hartlepool, TS25 1YD England Tel: (01429)863609
Fax : (01429) 863581 e-mail sales@isocom.co.uk
http://www.isocom.com
5/12/00
Off-State Output Terminal Voltage 550V
RMS Forward Current 100mA
Forward Current (Peak) 1.2A
Power Dissipation 300mW
(derate linearly 4.0mW/0C above 250C)
POWER DISSIPATION
Total Power Dissipation 330mW
(derate linearly 4.4mW/0C above 250C)
ISOCOM INC
1024 S. Greenville Ave, Suite 240,
Allen, TX 75002 USA
Tel: (214) 495-0755 Fax: (214) 495-0901
e-mail info@isocom.com
http://www.isocom.com
DB92762m-AAS/A1

ELECTRICAL CHARACTERISTICS ( TA = 25°C Unless otherwise noted )
PARAMETER MIN TYP MAX UNITS TEST CONDITION
Input Forward Voltage (VF) 1.2 1.5 V IF = 10mA
Reverse Current (IR) 100 µA VR = 3V
Output Peak Off-state Current ( I
Peak Blocking Voltage ( V
On-state Voltage ( V
TM
) 100 nA V
DRM
) 550 V I
DRM
= 550V (note 1 )
DRM
= 100nA
DRM
) 1.5 3.0 V ITM = 100mA ( peak )
Critical rate of rise of off-state
Voltage@ 400V ( dv/dt ) ( note 1 ) 1000 V/µs
Coupled Input Current to Trigger ( IFT )(note 2 ) 10 mA VD = 3V ( note 2 )
Holding Current , either direction ( IH ) 200 µA
Input to Output Isolation Voltage V
5300 V
ISO
7500 V
RMS
PK
See note 3
See note 3
Note 1. Test voltage must be applied within dv/dt rating.
Note 2. Guaranteed to trigger at an IF value less than or equal to max. I
between Rated I
Note 3. Measured with input leads shorted together and output leads shorted together.
and absolute max. I
FT
FT
.
, recommended IF lies
FT
5/12/00
DB92762m-AAS/A1

RMS On-state Current vs. Ambient Temperature
Normalised Repetitive Peak Off-state
Voltage vs. Ambient Temperature
1.4
0.1
(Arms)
T
0.05
RMS on-state current I
0
-30 0 25 50 75 100 125
Ambient temperature TA ( °C )
Forward Current vs. Ambient Temperature
80
70
60
(mA)
F
50
40
30
20
Forward current I
10
0
-30 0 25 50 75 100 125
Ambient temperature TA ( °C )
1.2
1.0
0.8
0.6
Normalised
to TA = 25°C
0.4
0.2
Normalised repetitive peak off-state voltage
0
-30 0 25 50 75 100
Ambient temperature TA ( °C )
On-state Voltage vs. Ambient Temperature
2.8
2.4
2.0
(V)
TM
1.6
1.2
0.8
On-state voltage V
0.4
0
-30 0 25 50 75 100
Ambient temperature TA ( °C )
5/12/00
Normalised Input Trigger Current
vs. Ambient Temperature
1.4
)
FT
1.2
1.0
0.8
0.6
Normalised
to TA = 25°C
0.4
0.2
Normalised input trigger current ( I
0
-30 0 25 50 75 100
Ambient temperature TA ( °C )
On-state Current vs. On-state Voltage
100
80
(mA)
TM
60
40
20
On-state current I
0
0 0.4 0.8 1.2 1.6 2.0
IF = 20mA
TA = 25°C
On-state voltage VTM (V)
DB92762m-AAS/A1