Datasheet IRKDL240-10S10 Specification

Page 1
Bulletin I27094 rev. C 10/06
IRK.L240 SERIES
FAST RECOVERY DIODES MAGN-A-pak
Fast recovery time characteristics Electrically isolated base plate Industrial standard package Simplified mechanical designs, rapid assembly High surge capability Large creepage distances 3000 V UL E78996 approved RoHS Compliant
isolating voltage
RMS
Description
The IRK.L240 Series of MAGN-A-paks uses fast re­covery power diodes in four basic configurations. The semiconductors are electrically isolated from the metal base, allowing common heatsinks and compact assemblies to be built. Application includes power supplies, battery chargers, welders, motor controls and general industrial current rectification. These modules are intended for those applications where fast recovery characteristics are required.
™™
™ Power Modules
™™
250A
Major Ratings and Characteristics
Parameters IRK.L240 Units
S10/S20 S30
I
F(AV)
@ T
C
I
F(RMS)
I
FSM
2
I
t@
2
I
√t 3220 2800 KA2√s
V
RRM
T
J
@ 50Hz 8000 7500 A @ 60Hz 8400 7850 A
50Hz 322 280 KA2s
@ 60Hz 294 2 56 KA
range -40 to 150
www.irf.com
250 240 A 100 100 ° C
392 377 A
up to 2500 V
2
s
o
C
1
Page 2
IRK.L240 Series
Bulletin I27094 rev. C 10/06
ELECTRICAL SPECIFICATIONS
Voltage Ratings
Type number Voltage t
rr
Code Code peak reverse voltage peak reverse voltage @ 150°C
06 S10 600 700 10 S10 1000 1100
IRK.L240 12 S20 1200 1300 50
14 S20 1400 1500 20 S30 2000 2100 25 S30 2500 2600
Forward Conduction
Parameter IRK.L240 Units Conditions
I
Max. average forward current 250 240 A 180o conduction, half sine wave
F(AV)
@ Case temperature 100 1 00 Max. RMS forward current 392 377 A as AC switch
I
F(RMS)
Max. peak, one-cycle forward, 8000 7500 A t = 10ms No voltage
I
FSM
non-repetitive surge current 840 0 78 50 t = 8.3ms reapplied
2
t Maximum I2t for fusing 322 2 8 0 KA2s t = 10ms No voltage Initial TJ = TJ max
I
2
I
√t Maximum I2√t for fusing 322 0 28 00 KA2√s t = 0.1 to 10ms, no voltage reapplied
V
Low level value of threshold
F(TO)1
voltage High level value of threshold
V
F(TO)2
voltage
r
Low level value of forward
f1
slope resistance
r
High level value of forward
f2
slope resistance Max. forward voltage drop 1.57 1.75 V
V
FM
V
, maximum repetitive V
RRM
, maximum non-repetitive I
RSM
RRM
VVmA
S10/S20 S30
o
C
675 0 630 0 t = 10ms 100% V 710 0 660 0 t = 8.3ms reapplied Sinusoidal half wave,
294 2 5 6 t = 8.3ms reapplied 228 1 98 t = 10ms 100% V 208 1 8 1 t = 8.3ms reapplied
0.98 0.98 V (16.7% x π x I
1.31 1.31 V (I > π x I
F(AV)
0.75 0.97 mΩ (16.7% x π x I
0.41 0.60 mΩ (I > π x I
F(AV)
I
= 800, TJ = 150 oC tp = 10 ms
FM
Av. power = V
RRM
RRM
< I < π x I
F(AV)
), TJ = TJ max.
< I < π x I
F(AV)
), TJ = TJ max.
x I
F(TO)
F(AV)
F(AV))TJ
F(AV))TJ
+ rf x (I
= TJ max
= TJ max
F(RMS)
2
)
max.
Blocking
I
RRM
V
INS
2
Max. peak reverse leakage current 50 mA T
= 150 oC, leakage current
J
RMS isolation voltage 3000 V 50Hz, circuit to base, all terminals shorted, 25°C, t = 1s
www.irf.com
Page 3
IRK.L240 Series
Bulletin I27094 rev. C 10/06
Thermal and Mechanical Specifications
TJMax. junction operating temperature -40 to 150 T
Max. storage temperature range -40 to 150
stg
Max. internal thermal resistance 0.125 K/W Per junction, DC operation
R
thJ-C
junction to case Thermal resistance, case Mounting surface flat, smooth and greased
R
thC-S
to heatsink Per module
0.02 K/W
T Mounting torque ±10%
MAP to heatsink 4 to 6 Nm be rechecked after a period of about 3 hours to allow for
the
Busbar to MAP 8 to 10 Nm spread of the compound
wt Approximate weight 850 (30) g (oz)
Case style MAGN-A-pak
o
C
o
C
A mounting compound is recommended and the torqshould
DR Conduction (per Junction)
(The following table shows the increment of thermal resistence R than DC)
Conduction angle Sinusoidal conduction Rectangular conduction Units Conditions
o
180 120
90 60 30
o
o
o
o
0.008 0.007 K/W TJ = TJ max.
0.010 0.011 K/W
0.013 0.015 K/W
0.019 0.020 K/W
0.032 0.033 K/W
when devices operate at different conduction angles
thJC
Recovery Characteristics
Test conditions Typ. values @ TJ = 150oC
Code
S10 500 100 5 0 135 100 S20 '' " " 250 145 S30 '' " " 360 200
I
pk
di/dt V
r
Q
rr
(A) (A/μs) (V) (μC) (A)
I
rr
I
FM
di dt
t
rr
t
Q
rr
I
(REC)
RM
Ordering Information Table
Device Code
1 - Module type 2 - Circuit configuration (See Outline Table) 3 - L = Fast recovery diode 4 - Current rating 5 - Voltage code: Code x 100 = VRRM (See Voltage Ratings Table) 6 - trr code (See Recovery Characteristics Table)
www.irf.com
IRK D L 240 - 25 S30
1 2 6
4
3
5
S10 = 1000 ns S20 = 2000 ns S30 = 3000 ns
3
Page 4
IRK.L240 Series
Bulletin I27094 rev. C 10/06
Outline Table
- All dimensions in millimeters (inches)
- Dimensions are nominal
- Full engineering drawings are available on request
- UL identification number for cathode wire: UL 1385
- UL identification number for package: UL 94V0
IRKD... IRKC... IRKJ... IRKE...
150
140
130
120
110
100
90
80
Max imum A ll owabl e Case Temperature (° C )
0 50 100 150 200 250 300
Av erage Forwar d Cu rrent (A)
Fig. 1 - Current Ratings Characteristics Fig. 2 - Current Ratings Characteristics
IRK. L2 40. . S10/ S20 Se ri e s R (DC) = 0.125 K/W
thJC
Conduction Angle
30°
60°
90°
120°
180°
4
150
140
130
120
110
100
90
80
Maximum Al lowable Case Temperature (°C)
0 50 100 150 200 250 300 350 400 450
Average F orwar d Cur r en t (A )
IRK.L240..S10/S20 Series R (DC) = 0.125 K/ W
thJC
30°
60°
90°
120°
Condu ction Peri od
180°
www.irf.com
DC
Page 5
IRK.L240 Series
Bulletin I27094 rev. C 10/06
400
180°
350
120°
90°
300
60° 30°
250
200
RMS Lim it
150
100
50
0
M axim um Av e rage Forwar d Pow er Loss (W )
0 50 100 150 200 250
Condu ction A ngle
IR K .L240..S 10/S20 Series Per Junc tion T = 150°C
Average Forward Curre nt (A)
Fig. 3 - Forward Power Loss Characteris­tics
8000
At Any Rated Load Condition And With
Rated V Appl ied Followi ng Surge.
7000
RRM
Initial T = 1 50 °C @ 60 Hz 0.0083 s
6000
@ 50 Hz 0.0100 s
5000
4000
600
DC
500
180° 120°
90°
400
60° 30°
300
RMS Limit
200
100
J
0
Maxi m um Average Forward Po we r L o ss ( W)
0 50 100 150 200 250 300 350 400
Conduction Per iod
IR K.L240..S 10/S 20 Series T = 150°C Per Junct ion
J
Averag e Fo rward Cu rren t ( A)
Fig. 4 - Forward Power Loss Characteristics
8500
Max imum Non Repeti tive Sur ge C urrent
J
7500
6500
Versus Pu lse Train Dur ation.
Initial T = 150°C
N o Voltage Reapplied
Rated V Reappli ed
J
RRM
5500
4500
3500
3000
IRK.L240..S10/S20 Series
Peak Half Sine Wave Forward Current (A)
Per Ju nc t ion
2000
110100
Number Of Eq ua l Amplitude Half Cycle Current Pulses (N)
Fig. 5 - Maximum Non-Repetitive Surge Current Fig. 6 - Maximum Non-Repetitive Surge Current
150
140
130
120
110
100
90
80
Maximu m Allowabl e Case Temper atu r e (°C)
0 50 100 150 200 250
Average Forward C urrent (A)
IRK.L240..S30 S eries R (DC) = 0.125 K/W
thJC
Con duction A n gle
30°
60°
Fig. 7 - Current Ratings Characteristics
www.irf.com
90°
120°
180°
2500
IRK.L240.. S10/S20 Series
Peak Half Sine Wave Forward Current (A)
Per Junction
1500
0.01 0.1 1 Pulse Train Duration (s)
150
140
130
120
110
100
90
80
Maximum A llowabl e C ase Temperature (°C)
0 50 100 150 200 250 300 350 400
Ave rage Forwar d C u rrent (A)
IRK.L240..S30 Series R (DC) = 0.12 5 K/ W
thJC
Condu ction Period
30°
60°
90°
120°
180°
Fig. 8 - Current Ratings Characteristics
DC
5
Page 6
IRK.L240 Series
Bulletin I27094 rev. C 10/06
400
180°
350
300
250
120°
90° 60° 30°
RMS Lim it
200
150
Conduction Angle
100
IRK.L 2 4 0..S30 Series
50
0
Max imum Av erage Forward Power Los s (W)
0 50 100 150 200 250
Per Junction T = 150°C
J
Average For war d C u rrent (A )
Fig. 9 - Forward Power Loss Characteristics
7000
6000
5000
4000
3000
Pea k Half Sine Wave Forward Cur r ent (A)
2000
At Any Ra ted Loa d Co ndition And With
Rated V Applied Following Surge.
RRM
IRK.L240..S30 S eries Per Junction
110100
Number Of Equa l Amplitude Half Cycle Current Pulses (N)
Initial T = 150°C
J
@ 60 Hz 0.0083 s @ 50 Hz 0.0100 s
550 500 450 400 350
DC 180° 120°
90°
60°
30°
300 250
RMS Lim it
200 150 100
50
0
Maxim u m A v erage Forward Power Loss (W)
0 50 100 150 200 250 300 350 400
IRK.L240..S30 Series Per Junc tion T = 150°C
J
Average Forward Curr ent ( A)
Fig. 10 - Forward Power Loss Characteristics
8000
Maximum Non Repetitive Surge Current
7000
6000
5000
4000
3000
IR K.L 240..S30 S eries
2000
Per Junction
Pea k Ha lf Sine Wave Forward Current (A)
1000
0.01 0.1 1
Versus Pulse Train Dur ation.
No Voltage Reapplied
R ated V R eapplied
Pulse Train Duration (s)
Fig. 11 - Maximum Non-Repetitive Surge Current Fig. 12 - Maximum Non-Repetitive Surge
Current
10000
IRK .L 2 40..S10/S20 Series Per Junction
10000
IRK.L240..S 30 Series Per Junct io n
Con ducti on Peri od
Initial T = 150°C
J
RRM
1000
T = 25°C
J
T = 150 ° C
I nstantaneous F orward Cu rrent (A )
100
1 1.5 2 2. 5 3 3.5
Instantaneous Forwar d Voltage (V)
J
Fig. 13 - Forward Voltage Drop Characteristics
6
1000
T = 25° C
J
T = 150 °C
I n stantaneous F orward Cu rrent (A)
100
0.5 1 1.5 2 2.5 3 3.5 4 4.5 I n stantaneous Forwar d V oltage (V)
J
Fig. 14 - Forward Voltage Drop Characteristics
www.irf.com
Page 7
IRK.L240 Series
Bulletin I27094 rev. C 10/06
150
IRK. L 240 ..S10
140 130
T = 150° C
J
I = 1000A
FM
120 110 100
90 80 70 60 50 40 30 20 10
10 20 30 40 50 60 70 80 90 100
Max imum Reverse Recovery Char ge - Qrr ( µC)
Rate O f Fal l Of Forw ard Cu rrent - di /dt ( A/µs)
Fig. 15 - Reverse Recovery Charge Characteristics
500 450
IR K .L 240..S 20 T = 150 °C
J
I = 1000A
FM
400 350 300 250 200 150 100
50
0
0 50 100 150 200
Maximum R everse R ecovery Charge - Qrr (µC)
Rate Of Fall Of Forw ard Cu rrent - di/dt (A/µ s)
Fig. 17 - Reverse Recovery Charge Characteris­tics
500 450 400
I = 1000A
FM
500A
350 300 250 200 150 100
50
0
0 50 100 150 200
Maximum Reverse R ecovery Charge - Qr r (µ C)
Rate Of Fall Of Forward Curr en t - di/dt (A /µs)
IR K .L240..S30 Series T = 150 °C
J
Fig. 19 - Reverse Recovery Charge Characteristics
500A
100A
500A
200A
100A
50A
200A
100A
50A
110
I = 1000A
100
90 80
FM
500A
200A
100A
50A
70 60 50 40 30 20 10
Maximum Reverse Rec overy Current - Irr (A)
10 20 30 40 50 60 70 80 90 100
IR K.L240..S10 Se ries
T = 150 °C
J
Rate O f Fal l Of For w ard Cu rre nt - di/dt (A/µs)
Fig. 16 - Reverse Recovery Current Characteristics
300
IRK.L 240..S 20
250
T = 150 °C
J
I = 1000A
FM
200
150
100
50
0
Maximum Reverse Recovery Cur rent - I r r (A)
0 50 100 150 200
Rate Of Fall Of Forward Current - di/dt (A/µs)
Fig. 18 - Reverse Recovery Current Characteristics
300
I = 1000A
FM
250
500A
200
150
100
50
0
Maximum Reverse Recovery Current - Irr (A)
0 50 100 150 200
IR K .L 240..S30 Series T = 150 °C
J
Rate Of Fall Of Forward Cur rent - di/dt (A/µs)
Fig. 20 - Reverse Recovery Current Characteristics
500A 200A
100A
50A
100A
www.irf.com
7
Page 8
IRK.L240 Series
4
Bulletin I27094 rev. C 10/06
1E5
1E4
1E3
0.01
0.02
0.04
0.1
0.2
0.4
4
2
1
20 joules per pulse
10
1E2
Peak For w ard Curren t (A)
1E1
IRK.L240..S10/ S20 Sin u soidal Pul se
tp
T = 150 °C
1E0
J
1E1 1E2 1E3 1E
Pulse Basewidth (µs)
Fig. 21 - Maximum Forward Energy Power Loss Characteristics
1E5
IRK.L240..S10/S 2 0 Sinusoidal Pulse
tp
T = 90 °C
C
1E4
1E3
20000
5000
1500
250010000
1000
200
Peak For ward Cur rent (A)
20 joules per pulse
10
4
2
1
0.4
0.2
0.1
0.04
0.02
0.01
IR K.L240..S10/S20 Trap ezoidal Pulse
tp
T = 150 °C
J
1E4
1E 1
E1 1E2 1E3 1E4
Pulse Basew id t h ( µs)
IRK.L240..S10/S20 Sinusoidal Pulse
tp
T = 100 °C
C
50 Hz400
1000
400
50 Hz
200150025001000020000 5000
1E2
1E1 1E2 1E3 1E4
1E4
E 1 1E2 1E 3 1E 4
1E1
Pulse Bas ewidth (µs)
Fig. 22 - Frequency Characteristics
1E5
IRK.L240..S10/ S20
Trapezoidal Pulse
tp
T = 90 °C
C
1E4
1E3
50 Hz400
Peak Forward Current (A)
1E2
1E11E21E31E4
1000
20015002500
1E 4
E1 1E2 1E3 1E4
1E 1
Pulse Ba sew id th (µs)
Fig. 23 - Frequency Characteristics
8
IR K.L240..S10/S20 Trapezoi dal Pul se
tp
T = 100 °C
C
Pulse Basew id th (µs )
2500
1500
1000
Pulse Basewidth (µs)
400
200
www.irf.com
50 Hz
Page 9
1E 5
4
20 joules per pulse
1E 4
1E 3
0.01
0.02
0.04
0.1
10
4
2
1
0.4
0.2
1E 2
Peak Forward Cur rent (A)
1E 1
IRK.L24 0..S30
Sinusoidal Pulse
tp
T = 150 °C
J
1E 0
1E 1 1E 2 1E3 1E
Pulse Basewidth (µs)
Fig. 24 - Maximum Forward Energy Power Loss Characteristics
IRK.L240 Series
Bulletin I27094 rev. C 10/06
20 joules per pulse
10
4
2
1
0.4
0.2
0.1
0.04
0.02
0.01
IRK.L240..S30 Trap ezoidal Pulse
tp
T = 150 °C
J
1E 4
E 1 1E2 1E3 1E 4
1E 1
Pulse Basewidth (µs)
1E 5
IRK.L240..S30
Sin uso id a l Pulse
tp
T = 90 °C
C
1E 4
1E 3
400
Peak Forward Cu r rent (A)
150025001000020000 5000
1000
1E 2
1E11E21E31E4
200
50 Hz
1E1
1E1 1E2 1E3 1E4
1E 4
Pulse Basewidth (µs)
Fig. 25 - Frequency Characteristics
1E 5
IRK.L24 0..S30 Trap ezoida l Pulse T = 90 °C
tp
C
1E 4
IR K.L240..S30 Sin uso id a l Pu lse T = 100 °C
tp
20000
10000
IRK.L240..S30 Trapezoidal Pulse T = 100 °C
tp
C
1500
2500
5000
Pulse Basewidth (µs)
C
1000
400
200
50 Hz
1E 3
Peak Forward Current (A)
150025005000
1000
400
200
1E 2
1E 1 1E 2 1E 3 1E 4
Pulse Base wid th (µs)
Fig. 26 - Frequency Characteristics
www.irf.com
50 Hz
1E4
1E1 1E 2 1E3 1E 4
1E1
5000
2500
1500
4001000
Pulse Basewidth (µs)
200
50 Hz
9
Page 10
IRK.L240 Series
Bulletin I27094 rev. C 10/06
1
Steady State Val u e : R = 0.125 K/ W
thJC
(DC Operati o n)
0.1
0.01
thJC
0.001
Transie n t Ther m al Impedance Z (K/W )
0.0001
0.0001 0.001 0.01 0.1 1 10 100 Square Wav e Pulse Durati on (s)
Fig. 27 - Thermal Impedance Z
IRK.L 2 40 .. Series Per Ju nction
Characteristics
thJC
10
www.irf.com
Page 11
IRK.L240 Series
Bulletin I27094 rev. C 10/06
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level.
Qualification Standards can be found on IR's Web site.