Datasheet IP3R07V, IP3R07K, IP3R07AV, IP1R07AK-883B, IP1R07AK Datasheet (Semelab Plc)

...
LAB
SEME
IP1R07A IP3R07A IP1R07A
IP3R07A
Semelab plc. Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Prelim. 4/96
Pin 1 – V
Pin 2 – V
C
Pin 3 – N/C Pin 4 – ADJ. Case – V
O
K Package – TO–3
Pin 1 – V
C
Pin 2 – N/C Pin 3 – V
O
Pin 4 – V
Pin 5 – ADJ.
V Package – TO–218
3 AMP
LOW DROPOUT
POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
Control Input to Output Voltage Power Input to Output Voltage
P
D
Power Dissipation
T
J
Operating Junction Temperature Range
T
STG
Storage Temperature
T
L
Lead Temperature (Soldering, 10 sec.)
35V 15V
Internally limited
See Order Information Table
–65 to +150°C
+300°C
ABSOLUTE MAXIMUM RATINGS (T
case
= 25°C unless otherwise stated)
FEATURES
• 1% OUTPUT VOLTAGE TOLERANCE (–A VERSIONS)
• 0.3% LOAD REGULATION
• 0.01%/V LINE REGULATION
• 0.8V DROPOUT VOLTAGE AT 3A
• COMPLETE SERIES OF PROTECTIONS:
• CURRENT LIMITING
• THERMAL SHUTDOWN
• SOA CONTROL
12
5
4
3
12 534
Pin 1 – V
C
Pin 2 – N/C Pin 3 – V
O
Pin 4 – V
Case – ADJ.
T Package – TO–220
Pin 1 – V
C
Pin 2 – V
Pin 3 – ADJ. Case – V
O
G Package – TO–257
345
12
1
23
Description
The IP3R07A series of low dropout adjustable voltage regulators are capable of supplying 3A of output current with an input-to-output voltage of just 0.8V. In applications where high efficiency is necessary it is now possible to obtain a low cost, single chip solution. These regulators are exceptionally easy to use, requiring only two external resistors to set the output voltage.
The IP3R07A exhibits an initial ±1% output voltage tolerance, and over all operating conditions the reference voltage is guaranteed not to vary more than ±2%. These devices include internal current limiting, thermal overload protection, and power device safe operating area compensation.
LAB
SEME
IP1R07A IP3R07A IP1R07A
IP3R07A
Semelab plc. Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Prelim. 4/96
Part K–Pack G–Pack T–Pack V–Pack Temp. Number (TO–3) (TO–257) (TO–220) (TO–218) Range
IP1R07A ✔✔ -55 to +150°C
IP1R07 ✔✔ ” IP3R07A ✔✔0 to 125°C IP3R07 ✔✔
Note:
To order, add the package identifier to the part number.
eg. IP1R07AK
Order Information
BIAS
VOLTAGE
REFERENCE
THERMAL
SHUTDOWN
CURRENT
LIMIT
POWER INPUT
CONTROL INPUT
INTERNAL PASS TRANSISTOR
CURRENT
LIMIT
SENSE
RESISTOR
A
V
OUTPUT
ADJUST
BLOCK DIAGRAM
121
ADJ
IP3R07A
1µF
6V 3A
V
P
V
C
1µF
10V
50mA
GND
10µF *
360
1µF **
5V 3A
V
O
V
OUT
Improves Ripple Rejection. Improves Transient Response.
*
**
R1
R2
NOTE:
V
O
= 1.25V
1 +
R2 R1
TYPICAL APPLICATION
LAB
SEME
IP1R07A IP3R07A IP1R07A
IP3R07A
Semelab plc. Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Prelim. 4/96
V
REF
Reference Voltage
V
OUT
Line Regulation
1
I
OUT
V
OUT
Load Regulation
1
I
OUT
Thermal Regulation
Ripple Rejection
Dropout Voltage (Power Input)
I
ADJ
Adjust Pin Current
I
ADJ
Adjust Pin Current Change
I
MIN
Minimum Load Current
I
CL
Current Limit
R
θJC
Thermal Resistance Junction to Case
I
O
= 10mA
I
O
= 10mA to 3A
V
C
– VO= 3V to 35V
V
– VO= 1.5V to 7V
P 20W T
J
= Over Temp. Range
1
VC– VO= 3V to 35V
T
J
= Over Temp. Range
1
IO= 10mA to 3A
T
J
= Over Temp. Range
1
tp= 20ms
C
ADJ
= 0
V
O
= 10V
C
ADJ
= 10µF
f = 120Hz
T
J
= Over Temp. Range
1
VO= 50mV
TJ= Over Temp. Range
1
IO= 10mA to 3A V
– VO= 1.5V to 7V
V
C
– VO= 3V to 35V
T
J
= Over Temp. Range
1
VC– VO= 35V T
J
= Over Temp. Range
1
VP– VO≤ 7V T
J
= Over Temp. Range
1
K Package Power Transistor V Package Control Circuitry T Package Power Transistor G Package Control Circuitry
1.238 1.250 1.262
1.225 1.250 1.270
0.005 0.010
0.020 0.050
0.10 0.30
0.30 1.0
0.002 0.010 65
66 86
0.8 1.0
50 100
0.2 5
3.5 5
3 4.5
1.2
0.5
2.3
0.7
1.20 1.25 1.30
0.005 0.030
0.020 0.070
0.10 0.50
0.30 1.5
0.002 0.030 65
66 86
0.8 1.0
50 100
0.2 5
3.5 10
3 4.5
1.2
0.5
2.3
0.7
V
V
% / V
%
%/W
dB
dB
V
µA
µA
mA
A
°C/W
IP1R07A IP1R07 IP3R07A IP3R07
Parameter Test Conditions
2
Min. Typ. Max. Min. Typ. Max. Units
Notes
1) Applies over full temperature range :– T
J
= –55 to +150°C for IP1R07A / IP1R07
T
J
= 0 to +125°C for IP3R07A / IP3R07
All other specifications apply at T
J
= 25°C unless otherwise stated.
2) Test conditions unless otherwise stated :–
VC- VO= 5V , VP- VO= 3V , I
OUT
= 3A.
Although Power Dissipation is internally limited, these specifications apply for Power Dissipation up to 50W.
3) Load and Line regulation are electrically independent and are measured using pulse techniques at low duty cycle in order to maintain constant junction temperature. To determine the effects on the output voltage due to device heating, refer to thermal regulation specification.