Pin 1 – ADJ.
Pin 2 – V
OUT
Case – V
IN
Q Package – TO254
Part K–Pack G/IG–Pack T–Pack V–Pack Q-Pack Temp.
Number (TO–3) (TO–257) (TO–220) (TO–218) (TO-254) Range
IP150A ✔✔ ✔-55 to +150°C
IP150 ✔✔ ✔ ”
LM150 ✔✔-55 to +150°C
IP350A ✔✔✔0 to 125°C
IP350 ✔✔✔ ”
IP150A SERIES
IP150A SERIES
IP350A SERIES
IP350A SERIES
LM150 SERIES
Prelim.9/00
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
Pin 1 – ADJ.
Pin 2 – V
IN
Case – V
OUT
K Package – TO–3
Pin 1 – ADJ.
Pin 2 – V
OUT
Pin 3 – V
IN
Case – V
OUT
V Package – TO–218
3 AMP
POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
V
I–O
Input - Output Differential Voltage
P
D
Power Dissipation
T
J
Operating Junction Temperature Range
T
STG
Storage Temperature
T
L
Lead Temperature (Soldering, 10 sec.)
35V
Internally limited
See Table Above
–65 to 150°C
300°C
ABSOLUTE MAXIMUM RATINGS (T
case
= 25°C unless otherwise stated)
FEATURES
• OUTPUT VOLTAGE RANGE OF 1.25 TO 35V
• 1% OUTPUT VOLTAGE TOLERANCE
(–A VERSIONS)
• 0.3% LOAD REGULATION
• 0.01%/V LINE REGULATION
• COMPLETE SERIES OF PROTECTIONS:
• CURRENT LIMITING
• THERMAL SHUTDOWN
• SOA CONTROL
Pin 1 – ADJ.
Pin 2 – V
OUT
Pin 3 – V
IN
Case – V
OUT
T Package – TO–220
Pin 1 – ADJ.
Pin 2 – V
OUT
Pin 3 – V
IN
Case – V
OUT*
G Package – TO–257
IG Package - TO-257
* Isolated case on IG Package
Note:
To order, add the package identifier to the part
number.
eg. IP150AQ
Order Information

V
REF
Reference Voltage
D
V
OUT
Line Regulation
1
D
I
OUT
D
V
OUT
Load Regulation
1
D
I
OUT
Thermal Regulation
Ripple Rejection
I
ADJ
Adjust Pin Current
D
I
ADJ
Adjust Pin Current
Change
I
MIN
Minimum Load
Current
I
CL
Current Limit
D
V
OUT
Temperature
D
TEMP Stability
D
V
OUT
Long Term Stability
D
TIME
e
n
RMS Output Noise
(% of V
OUT
)
R
q
JC
Thermal Resistance
Junction to Case
I
OUT
= 10mA
I
OUT
= 10mA to 3A
V
IN
– V
OUT
= 3V to 35V
P£30W T
J
= –55 to +150°C
V
IN
– V
OUT
= 3V to 35V
T
J
= –55 to +150°C
I
OUT
= 10mA to 3A V
OUT
£
5V
T
J
= –55 to +150°C
I
OUT
= 10mA to 3A V
OUT
³
5V
T
J
= –55 to +150°C
t
p
= 20ms TA= 25°C
C
ADJ
= 0
V
OUT
= 10V
C
ADJ
= 10mF
f = 120Hz
T
J
= –55 to +150°C
T
J
= –55 to +150°C
I
OUT
= 10mA to 3A
V
IN
– V
OUT
= 3V to 35V
T
J
= –55 to +150°C
V
IN
– V
OUT
= 35V
T
J
= –55 to +150°C
V
IN
– V
OUT
£
10V
T
J
= –55 to +150°C
V
IN
– V
OUT
= 30V
TJ= –55 to +150°C
T
A
= 125°C t = 1000 Hrs
f = 10 Hz to 10 kHz
T
A
= 25°C
K Package (TO–3)
G Package (TO–257)
1.238 1.25 1.262
1.225 1.250 1.270
0.005 0.010
0.020 0.050
515
15 50
0.1 0.3
0.3 1
0.002 0.010
65
66 86
50 100
0.2 5
3.5 5
3 4.5
0.3 1
12
0.3 1
0.001
1.5
34
1.200 1.250 1.300
0.005 0.010
0.020 0.050
515
20 50
0.1 0.3
0.3 1
0.002 0.010
65
66 86
50 100
0.2 5
3.5 5
3 4.5
0.3 1
1
0.3 1
0.001
1.5
34
V
V
% / V
mV
%
%/W
dB
dB
m
A
m
A
mA
A
A
%
%
%
°C/W
IP150A SERIES
IP150A SERIES
IP350A SERIES
IP350A SERIES
LM150 SERIES
Prelim.9/00
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications. Load regulation is measured from the bottom of the package
for the TO–3 package and on the back of the heat tab for the TO–218, TO–220 and TO–257 packages.
2) Test Conditions unless othewise stated: V
IN
– V
OUT
= 5V , TJ= 25°C , I
OUT
= 1.5A.
Although power dissipation is internally limited, these specifications apply for dissipations of 30W for the TO–3, TO–218 and
TO–257 packages, and 25W for the TO–220 package; I
MAX
= 3A.
LM150
IP150A IP150
Parameter Test Conditions Min. Typ. Max. Min. Typ. Max. Units

IP150A SERIES
IP150A SERIES
IP350A SERIES
IP350A SERIES
LM150 SERIES
Prelim.9/00
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications. Load regulation is measured from the bottom of the package
for the TO–3 package and on the back of the heat tab for the TO–218, TO–220 and TO–257 packages.
2) Test Conditions unless othewise stated: V
IN
– V
OUT
= 5V , TJ= 25°C , I
OUT
= 1.5A.
Although power dissipation is internally limited, these specifications apply for dissipations of 30W for the TO–3, TO–218 and
TO–257 packages, and 25W for the TO–220 package; I
MAX
= 3A.
IP350A IP350
Parameter Test Conditions Min. Typ. Max. Min. Typ. Max. Units
V
REF
Reference Voltage
D
V
OUT
Line Regulation
1
D
I
OUT
D
V
OUT
Load Regulation
1
D
I
OUT
Thermal Regulation
Ripple Rejection
I
ADJ
Adjust Pin Current
D
I
ADJ
Adjust Pin Current
Change
I
MIN
Minimum Load
Current
I
CL
Current Limit
D
V
OUT
Temperature
D
TEMP Stability
D
V
OUT
Long Term Stability
D
TIME
e
n
RMS Output Noise
(% of V
OUT
)
R
q
JC
Thermal Resistance
Junction to Case
I
OUT
= 10mA
I
OUT
= 10mA to 3A
V
IN
– V
OUT
= 3V to 35V
P£30W T
J
= 0 to +125°C
V
IN
– V
OUT
= 3V to 35V
T
J
= 0 to +125°C
I
OUT
= 10mA to 3A V
OUT
£
5V
T
J
= 0 to +125°C
I
OUT
= 10mA to 3A V
OUT
³
5V
T
J
= 0 to +125°C
t
p
= 20ms TA= 25°C
C
ADJ
= 0
V
OUT
= 10V
C
ADJ
= 10mF
f = 120Hz
T
J
= 0 to +125°C
T
J
= 0 to +125°C
I
OUT
= 10mA to 3A
V
IN
– V
OUT
= 3V to 35V
T
J
= 0 to +125°C
V
IN
– V
OUT
= 35V
T
J
= 0 to +125°C
V
IN
– V
OUT
£
10V
T
J
= 0 to +125°C
V
IN
– V
OUT
= 30V
TJ= 0 to +125°C
T
A
= 125°C t = 1000 Hrs
f = 10 Hz to 10 kHz
T
A
= 25°C
K Package (TO–3)
T Package (TO–220)
V Package (TO–218)
1.238 1.25 1.262
1.225 1.250 1.270
0.005 0.010
0.020 0.050
515
15 50
0.1 0.3
0.3 1
0.002 0.010
65
66 86
50 100
0.2 5
3.5 5
3 4.5
0.25 1
12
0.3 1
0.001
1.5
34
1.5
1.200 1.250 1.300
0.005 0.030
0.020 0.070
525
20 70
0.1 0.5
0.3 1.5
0.002 0.030
65
66 86
50 100
0.2 5
3.5 10
3 4.5
0.25 1
1
0.3 1
0.001
1.5
34
1.5
V
V
% / V
mV
%
%/W
dB
dB
m
A
m
A
mA
A
A
%
%
%
°C/W

IP150A SERIES
IP150A SERIES
IP350A SERIES
IP350A SERIES
LM150 SERIES
Prelim.9/00
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
-0.5
-0.4
-0.3
-0.2
-0.1
0
0.1
-75 -50 -25 0 25 50 75 100 125 150
Temperature (˚C)
Output Voltage Deviation (%)
I = 500mA
L
I = 1.5A
L
I = 3A
L
V = 10V
OUT
V = 15V
IN
0.0001
0.001
0.01
0.1
1
10
10
1
10
2
10
3
10
4
10
5
10
6
Frequency (Hz)
Output Impedance (
Ω
)
= 15V
IN
V
OUT
=10V
OUT
= 500mAI
V
ADJ
C= 0
OUT
C= 0
µ
F
ADJ
C = 10µF
OUT
C = 10
30
35
40
45
50
55
60
65
-75 -50 -25 0 25 50 75 100 125 150
Temperature (˚C)
Adjustment Current (
µ
A)
0.50
1.00
1.50
2.00
2.50
3.00
-75 -50 -25 0 25 50 75 100 125 150
Temperature (˚C)
Input – Ou tp ut Di ffe re n tia l (V )
∆V∆
V = 100mV
OUT
I = 3A
L
I = 2A
L
I = 500mA
L
I = 20mA
L
I = 200mA
L
-50 -25 0 25 50 75 100 125 150
1.23
1.24
1.25
1.26
1.27
Temperature (˚C)
Reference Voltage (V)
TJ= 25˚C
0 5 10 15 20 25 30 35 40
0
1
2
3
4
5
Input – Output Differential (V)
Qu iesc ent Curr e nt (mA )
TJ= 150˚C
TJ= -55˚C
0
20
40
60
80
100
0.01 0.1 1 10
Output Current (A)
Ripple Rejection (dB)
TJ= 25˚C
= 15V
IN
V
V
OUT
=10V
f = 120Hz
ADJ
C= 0
ADJ
C = 10µF
Output Voltage (A)
0 5 10 15 20 25 30 35
0
20
40
60
80
100
Ripple Rejection (dB)
-V
OUT
= 5V
IN
V
OUT
= 500mAI
f = 120Hz
T
J
= 25˚C
ADJ
C = 10µF
ADJ
C= 0
ADJ
C= 0
Frequency (Hz)
10 100
1k 10k 100k 1M
0
20
40
60
80
100
Ripple Rejection (dB)
ADJ
C = 10µF
V
OUT
=10V
= 15V
IN
V
OUT
= 500mAI
Load Regulation Output Impedance Adjustment Current
Droput Voltage Temperature Stability Minimum Operating Current
Ripple Rejection Ripple Rejection Ripple Rejection
TYPICAL PERFORMANCE CHARACTERISTICS

IP150A SERIES
IP150A SERIES
IP350A SERIES
IP350A SERIES
LM150 SERIES
Prelim.9/00
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
0 5 10 15 20 25 30 35
0
2
4
6
Ou tp u t C u rre n t (A )
TJ= 150˚C
TJ= -55˚C
TJ= 25˚C
Input – Output Differential (V)
V = 5V
OUT
V = 10V
IN
0.1 1 10 100
0
1
2
3
4
5
6
7
Ou tp u t C u rre n t (A )
T = 25˚C
CASE
PRELOAD = 0
PRELOAD = 1.5A
Time (ms)
-V
OUT
= 10V
IN
V
T = 25˚C
CASE
0.1 1 10 100
0
1
2
3
4
5
6
7
Ou tp u t C u rre n t (A )
PRELOAD CURRENT= 0
-V
OUT
= 15V
IN
V
-V
OUT
= 20V
IN
V
-V
OUT
= 30V
IN
V
Time (ms)
Current Limit Current Limit Current Limit
ADJ
C= 0
ADJ
C = 10µF
V
OUT
=10V
0.5
0.5
0
0.5
1
Output Voltage Deviation (V)
0 10203040
Input V oltage
Change (V)
1.5
0
1
1
L
C= 0
L
C= 1µF
= 50mA
OUT
I
= 25˚C
J
T
Time ( s)
µ
ADJ
C = 10µF
L
C= 1µF
ADJ
C= 0
V
OUT
=10V
L
C= 0
= 25˚C
J
T
0 10203040
Time ( s)
µ
Output Voltage D eviation (V)Load Current
(A)
0.5
0.5
0
0.5
1
1
1.5
1.5
1
0
1.5
VV = 15V
IN
PRELOAD = 50mA
Line Transient Response Load Transient Response
TYPICAL PERFORMANCE CHARACTERISTICS

IP150A SERIES
IP150A SERIES
IP350A SERIES
IP350A SERIES
LM150 SERIES
Prelim.9/00
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
Ω
µ
Ω
Ω
Ω
Ω
OUT
P
L
IN IN
IN
8
6
4
3
2
7
1
25
F1k5
121
25
383
5V
VV V
R
R
(Max Drop 300mV)
OUTPUT
RETURN
RETURN
V
LM301A
ADJ
IP350A
IN
OUT
IN OUT
1F
1k
121
1k
383
V
V
5V
ADJ
VV
2N3904
TTL
IP350A
Ω
Ω
Ω
µ
Ω
IN OUT
PP
1F
1%
249
39k
18k
100k
750
1%
3.24k
1%
ADJ
VV
To
To OE
READ
WRITE
BYTE ERASE
CHIP ERASE
+24V
V
IP350A
All gates 7406.
Ω
µ
Ω
Ω
Ω
Ω
Ω
OUTIN IN
1F
R1
121
C1
10 F
R2
383
VV
ADJ
V
5V
IP350A
Ω
µ
µ
Ω
THERMALLY
COUPLE
IN OUTIN
20k
50
10k
50k
12V
243
2N3906
1N4001
VVV
ADJ
IP350A
Ω
Ω
Ω
Ω
Ω
Remote Sensing 5V Regulator with Shut Down
Improving Ripple Rejection
Temperature Compensated Lead–Acid Battery Charger
OE V
PP
READ 0V 5V
WRITE
BYTE 5V 21V
CHIP ERASE 12V 21V
2816 EEPROM Supply Programmer for
Read/Write Control
APPLICATIONS INFORMATION
C1 improves ripple rejection.
X
C