Datasheet LM120G-12, LM120AR-05, LM120AK-15, LM120AK-12, LM120AK-05 Datasheet (Semelab Plc)

...
IP120A SERIES IP120 SERIES IP7900A SERIES IP7900 SERIES LM120 SERIES
Prelim. 2/99
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
OUT
Case – V
IN
K Package – TO–3
OUT
Case – V
IN
R Package – TO–66
12
3
3
12
IN
Pin 3 – V
OUT
SMD Package – SMD1
Ceramic Surface Mount
!
1.5 AMP
NEGATIVE
VOLTAGE REGULATOR
FEATURES
OUTPUT VOLTAGES OF -5, -12, -15V
0.01% / V LINE REGULATION
0.3% / A LOAD REGULATION
THERMAL OVERLOAD PROTECTION
SHORT CIRCUIT PROTECTION
OUTPUT TRANSISTOR SOA PROTECTION
1% VOLTAGE TOLERANCE OPTION (–A VERSIONS)
V
I
DC Input Voltage (for VO= -5, -12, -15V)
P
D
Power Dissipation
T
j
Operating Junction Temperature Range
T
stg
Storage Temperature
35V
Internally limited
–55 to 150°C –65 to 150°C
DESCRIPTION
The IP120A / LM120 / IP7900A / IP7900 series of 3 terminal regulators is available with several fixed output voltage making them useful in a wide range of applications.
The A suffix devices provide 0.01% / V line regulation,
0.3% / A load regulation and ±1% output voltage tolerance at room temperature.
Protection features include Safe Operating Area current limiting and thermal shutdown.
IN
Pin 3 – V
OUT
Case – V
IN
G Package – TO–257
IG Package– TO–257*
* isolated Case on IG package
1
23
J Package – 8 Pin Cerdip
45
1
2
3
8
7
6
GND
NC
NC
NC
NC
NC
V
OUT
V
IN
ABSOLUTE MAXIMUM RATINGS (T
case
= 25°C unless otherwise stated)
IP120A SERIES IP120 SERIES IP7900A SERIES IP7900 SERIES LM120 SERIES
Prelim. 2/99
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
IP7905A IP7905 , IP120–05
IP120A–05 LM120–05
Parameter Test Conditions Min. Typ. Max. Min. Typ. Max. Units
-4.9 -5 -5.1
-4.8 -5.2
-4.75 -5.25
325
350
125 250
10 75
425
750
1 1.9 12
0.2 0.4
0.2 0.5
0.1 0.4
0.1 1.0
40 400
54 80
54 80
1.1 2.3 5
0.6 1.2
2.4 3.3
0.2 2
-7.3
-4.95 -5 -5.05
-4.85 -5.15
-4.75 -5.15
310
310
14 112
10 25
415
725
1 1.9 12
0.2 0.4
0.2 0.5
0.1 0.4
0.1 0.5
40 400
66 80
66 80
1.1 2.3 5
0.6 1.2
2.4 3.3
0.2 2
-7.3
V
V
mV
mV
mA
mA
m
V
dB
V
m
W
A
mV
°C
V
V
O
Output Voltage
V
O
Low Supply
D
V
O
Line Regulation
D
V
O
Load Regulation
I
Q
Quiescent Current
D
I
Q
Quiescent Current Change
V
N
Output Noise Voltage
D
V
IN
Ripple Rejection
D
V
O
Dropout Voltage
R
O
Output Resistance
I
sc
Short Circuit Current
I
pk
Peak Output Current
Average Temperature
Coefficient of V
O
Input Voltage required to
maintain line regulation
I
O
= 500mA VIN= -10V
I
O
= 5mA to I
MAX
VIN= -7.5V to -20V
P
D
£
P
MAX
TJ= -55 to 150°C
I
O
= 5mA to I
MAX
PD£
P
MAX
VIN= -7V to -20V
V
IN
= -7V to -25V
I
O
= 0.5 I
MAX
VIN= -7.5V to -20V T
J
= -55 to 150°C
V
IN
= -8V to -12V
I
O
£
I
MAX
TJ= -55 to 150°C I
O
= 5mA to 1.5A
V
IN
= -10V
I
O
= 250mA to 750mA
I
O
= 5mA to I
MAX
VIN= -10V
T
J
= -55 to 150°C
I
O
£
0.5 I
MAX
VIN= -10V TJ= -55 to 150°C I
O
= 5mA to I
MAX
VIN= -10V TJ= -55 to 150°C
V
IN
= -7V to -25V
I
O
£
0.5 I
MAX
VIN= -8V to -25V T
J
= -55 to 150°C f = 10Hz to 100kHz V
IN
= -10V
I
O
£
I
MAX
f = 120Hz
I
O
£
0.5 I
MAX
VIN= -8V to -18V
T
J
= -55 to 150°C I
O
= I
MAX
f = 1 kHz
VIN= -35V
V
IN
= -10V
I
O
= 5mA
I
O
£
I
MAX
1) All characteristics are measured with a capacitor across the input of 0.22mF and a capacitor across the output of 0.1mF. All characteristics except noise voltage and ripple rejection ratio are measured using pulse techniques (t
p
£
10ms, 5%). Output
voltage changes due to changes in internal temperature must be taken into account separately.
2) Test Conditions unless otherwise stated:P
MAX
= 10W for TO–220SM ,P
MAX
= 1W for Cerdip, P
MAX
= 20W for all other package
devices I
MAX
= 1.0A , TJ= 25°C
IP120A SERIES IP120 SERIES IP7900A SERIES IP7900 SERIES LM120 SERIES
Prelim. 2/99
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
IP7912A IP7912 , IP120–12
IP120A–12 LM120–12
Parameter Test Conditions Min. Typ. Max. Min. Typ. Max. Units
V
O
Output Voltage
V
O
Low Supply
D
V
O
Line Regulation
D
V
O
Load Regulation
I
Q
Quiescent Current
D
I
Q
Quiescent Current Change
V
N
Output Noise Voltage
D
V
IN
Ripple Rejection
D
V
O
Dropout Voltage
R
O
Output Resistance
I
sc
Short Circuit Current
I
pk
Peak Output Current
Average Temperature
Coefficient of V
O
Input Voltage required to
maintain line regulation
I
O
= 500mA VIN= -19V
V
IN
= -14.8V to -27V PD£
P
MAX
IO= 5mA to I
MAX
TJ= -55 to 150°C
I
O
= 5mA to I
MAX
PD£
P
MAX
VIN= -14.5V to -27V
V
IN
= -14.5V to -30V
I
O
= 0.5 I
MAX
VIN= -14.8V to -27V T
J
= -55 to 150°C
I
O
£
I
MAX
VIN= -16V to -22V TJ= -55 to 150°C
I
O
= 5mA to 1.5A
V
IN
= -19V
I
O
= 250mA to 750mA
V
IN
= -19V IO= 5mA to I
MAX
TJ= -55 to 150°C
I
O
£
0.5 I
MAX
VIN= -19V TJ= -55 to 150°C I
O
= 5mA to I
MAX
VIN= -19V TJ= -55 to 150°C
V
IN
= -14.5V to -30V
I
O
£
0.5 I
MAX
VIN= -15V to -30V T
J
= -55 to 150°C f = 10Hz to 100kHz V
IN
= -19V
f = 120Hz I
O
£
I
MAX
VIN= -15V to IO£
0.5 I
MAX
-25V TJ= -55 to 150°C I
O
= I
MAX
f = 1 kHz
VIN= -35V
V
IN
= -19V
I
O
= 5mA
I
O
£
I
MAX
-11.88 -12 -12.12
-11.64 -12.36
-11.40 -12.36
418
418
14 29
12 32
419
860
0.2 0.4 12
0.2 0.4
0.2 0.5
0.1 0.4
0.1 0.5
75 960
58 72
58 72
1.1 2.3 8
0.6 1.2
2.4 3.3
0.5 4.8
-14.5
V
V
mV
mV
mA
mA
m
V
dB
V
m
W
A
mV
°C
V
-11.76 -12 -12.24
-11.52 -12.48
-11.40 -12.60
4 120
4 200
125 260
12 80
460
8 120
0.2 0.4 12
0.2 0.4
0.2 0.5
0.1 0.4
0.1 1.0
75 960
56 72
56 72
1.1 2.3 8
0.6 1.2
2.4 3.3
0.5 4.8
-14.5
1) All characteristics are measured with a capacitor across the input of 0.22mF and a capacitor across the output of 0.1mF. All characteristics except noise voltage and ripple rejection ratio are measured using pulse techniques (t
p
£
10ms, 5%). Output
voltage changes due to changes in internal temperature must be taken into account separately.
2) Test Conditions unless otherwise stated: P
MAX
= 10W for TO–220SM , P
MAX
= 1W for Cerdip, P
MAX
= 20W for all other package
devices I
MAX
= 1.0A , TJ= 25°C
IP120A SERIES IP120 SERIES IP7900A SERIES IP7900 SERIES LM120 SERIES
Prelim. 2/99
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
IP7915A IP7915 , IP120–15
IP120A–15 LM120–15
Parameter Test Conditions Min. Typ. Max. Min. Typ. Max. Units
V
O
Output Voltage
V
O
Low Supply
D
V
O
Line Regulation
D
V
O
Load Regulation
I
Q
Quiescent Current
D
I
Q
Quiescent Current Change
V
N
Output Noise Voltage
D
V
IN
Ripple Rejection
D
V
O
Dropout Voltage
R
O
Output Resistance
I
sc
Short Circuit Current
I
pk
Peak Output Current
Average Temperature
Coefficient of V
O
Input Voltage required to
maintain line regulation
I
O
= 500mA VIN= -23V
V
IN
= -17.9V to -30V PD£
P
MAX
IO= 5mA to I
MAX
TJ= -55 to 150°C
I
O
= 5mA to I
MAX
PD£
P
MAX
VIN= -17.5V to -30V
V
IN
= -17.5V to -30V
I
O
= 0.5 I
MAX
VIN= -17.9V to -30V T
J
= -55 to 150°C
I
O
£
I
MAX
VIN= -20V to -26V TJ= -55 to 150°C
I
O
= 5mA to 1.5A
V
IN
= -23V
I
O
= 250mA to 750mA
V
IN
= -23V IO= 5mA to I
MAX
TJ= -55 to 150°C
I
O
£
0.5 I
MAX
VIN= -23V TJ= -55 to 150°C I
O
= 5mA to I
MAX
VIN= -23V TJ= -55 to 150°C
V
IN
= -17.5V to -30V
I
O
£
0.5 I
MAX
VIN= -18.5V to -30V T
J
= -55 to 150°C f = 10Hz to 100kHz V
IN
= -23V
f = 120Hz I
O
£
I
MAX
VIN= -18.5V to IO£
0.5 I
MAX
-28.5V TJ= -55 to 150°C I
O
= I
MAX
f = 1 kHz
VIN= -35V
V
IN
= -23V
I
O
= 5mA
I
O
£
I
MAX
-14.85 -15 -15.15
-14.55 -15.45
-14.25 -15.45
422
422
210 530
12 35
421
975
1 1.9 12
0.2 0.4
0.2 0.5
0.1 0.4
0.1 0.5
90 1200
56 70
56 70
1.1 2.3 9
0.6 1.2
2.4 3.3
0.6 6
-17.5
V
V
mV
mV
mA
mA
m
V
dB
V
m
W
A
mV
°C
V
-14.7 -15 -15.3
-14.4 -15.6
-14.25 -15.75
4 150
4 250
275 5 150
12 80
475
9 150
1 1.9 12
0.2 0.4
0.2 0.5
0.1 0.4
0.1 1.0
90 1200
54 70
54 70
1.1 2.3 9
0.6 1.2
2.4 3.3
0.6 6
-17.5
1) All characteristics are measured with a capacitor across the input of 0.22mF and a capacitor across the output of 0.1mF. All characteristics except noise voltage and ripple rejection ratio are measured using pulse techniques (t
p
£
10ms, 5%). Output
voltage changes due to changes in internal temperature must be taken into account separately.
2) Test Conditions unless otherwise stated: P
MAX
= 10W for TO–220SM , P
MAX
= 1W for Cerdip, P
MAX
= 20W for all other package
devices I
MAX
= 1.0A , TJ= 25°C
IP120A SERIES IP120 SERIES IP7900A SERIES IP7900 SERIES LM120 SERIES
Prelim. 2/99
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk
GND
V
IN
V
OUT
C1*
2.2
µ
F
TANT.
C2** 1µF TANT.
INPUT OUTPUT
GND
V
IN
V
OUT
C1
2.2
µ
F
TANT.
INPUT OUTPUT
R1
R2
C2 1
µ
F
TANT.
R1
GND
V
IN
V
OUT
C1
2.2
µ
F
TANT.
INPUT
OUTPUT
I
OUT
C2 1µF TANT.
Fixed Output Regulator
* Required if the regulator is located far from
the power supply.
** Required for stability. 25mF electrolytic may
be substituted.
Current RegulatorAdjustable Output Regulator
APPLICATIONS INFORMATION
(R1+R2)
V
OUT
»
V
REG
R1
V
REG
I
OUT
=
+ I
Q
R1
Part K–Pack R–Pack G/IG–Pack SG–Pack J–Pack Temp. Number (TO–3) (TO–66) (TO–257) SMD1 8 Pin Cerdip Range
IP7900A ✔✔✔✔✔-55 to +150°C IP7900 ✔✔✔✔✔ IP120A ✔✔✔✔✔ IP120 ✔✔✔✔✔ LM120 ✔✔✔✔✔
Note:
To order, add the package identifier to the part number. eg. IP7900AK
IP120SG
Order Information
Loading...