Datasheet IKA63-40, IKA40-40 Specification

Page 1
R
Installation contactors
Installation contactors
Installation contactors are electromagnetic switching devices for switching of all kind of electric loads. They have one position of rest, capable of making, carrying and breaking currents under normal circuit conditions including operating overload conditions.
Page 2
For universal switching
All kind of motors Electric heating Lights and lighting Electrical and electronic equipment
Switch
Installation contactors are the most flexible switching devices for use in all types of applications. In electronic system provide reliable, safe and efficient management of electrical equipment.
Advanced operation
Remote control Manual control
Other benefits
Silent hum-free AC/DC version with
overvoltage protection Available also standard AC version Fast switching Wide application Mounting on 35 mm rail Sealing terminal covers Control voltages up to 400 V
Installation contactors ............................................................................
Installation contactors with manual control ........................................
Installation contactors with manual momentary control...................
UL/CSA installation contactors .............................................................
Accessories ..............................................................................................
Installation switches and installation momentary switches .............
page 2 page 6 page 9 page 11 page 14 page 16
Ordering data ...........................................................................................
Technical characteristics ........................................................................
Dimensions ..............................................................................................
page 5, 8, 10, 13 page 18 page 38
1
Page 3
Installation Contactors
up to 32 A
AC-1 acc. to IEC/EN 60947-4-1 (2-pole, 1 module)
Type
IKA20-20 IKA20-20 IKA225-20 IKA225-20 IKA232-20 IKA232-20
IKA20-11 IKA20-11 IKA225-11 IKA225-11 IKA232-11 IKA232-11
IKA20-10 IKA20-10 IKA225-10 IKA225-10 IKA232-10 IKA232-10
IKA20-01 IKA20-01 IKA225-01 IKA225-01 IKA232-01 IKA232-01
IKA20-02 IKA20-02 IKA225-02 IKA225-02 IKA232-02 IKA232-02
Rated
current I
20 A 20 A 25 A 25 A 32 A 32 A
20 A 20 A 25 A 25 A 32 A 32 A
20 A 20 A 25 A 25 A 32 A 32 A
20 A 20 A 25 A 25 A 32 A 32 A
20 A 20 A 25 A 25 A 32 A 32 A
Control voltage
at 50/60 Hz
e
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
Wiring diagram
3
1
A1
4
2
A2
1
R3
A1
R4
2
A2
1
A1
2
A2
A1 R1
R2
A2
R3
A1
R1
R4
R2
A2
Ordering No.
30.046.005
30.046.021
30.046.714
30.046.711
30.046.833
30.046.834
30.046.009
30.046.022
30.046.715
30.046.712
30.046.835
30.046.836
30.046.457
30.046.837
30.046.713
30.046.710
30.046.838
30.046.839
30.046.716
30.046.840
30.046.841
30.046.842
30.046.843
30.046.844
30.046.010
30.046.023
30.046.845
30.046.846
30.046.847
30.046.848
Weight
(g)
130 130 130 130 130 130
130 130 130 130 130 130
125 125 125 125 125 125
125 125 125 125 125 125
130 130 130 130 130 130
Packaging
(pcs)
6
6
6
6
6
AC
AC-1 acc. to IEC/EN 60947-4-1 (4-pole, 2 modules)
Type
IKA25-40 IKA25-40 IKA432-40 IKA432-40
IKA25-31 IKA25-31 IKA432-31 IKA432-31
IKA25-30 IKA25-30 IKA432-30 IKA432-30
IKA25-22 IKA25-22 IKA432-22 IKA432-22
IKA25-04 IKA25-04 IKA432-04 IKA432-04
Other control voltages are on request - define type and voltage
Rated
current I
25 A 25 A 32 A 32 A
25 A 25 A 32 A 32 A
25 A 25 A 32 A 32 A
25 A 25 A 32 A 32 A
25 A 25 A 32 A 32 A
Control voltage
at 50/60 Hz
e
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
Wiring diagram
1
3
A1
2
1
2
1 365
2
1
R3
R4
2
R4
6
4
5
3
4
4
R5
R6
R5
A2
A1
A2
A1
A2
A1
A2
A1 R1 R3
A2 R2
Ordering No.
75
8
R7
R86
30.046.007
30.046.027
30.046.849
30.046.850
30.046.013
30.046.028
30.046.851
30.046.852
30.046.282
30.046.853
30.046.854
30.046.855
7
8
R7
R8R6
30.046.014
30.046.029
30.046.856
30.046.857
30.046.015
30.046.030
30.046.858
30.046.859
Weight
(g)
230 230 230 230
230 230 230 230
225 225 225 225
230 230 230 230
230 230 230 230
Packaging
(pcs)
AC
3
3
3
3
3
2
Page 4
Installation Contactors
from 20 A up to 63 A
AC-1 acc. to IEC/EN 60947-4-1 (4-pole, 3 modules)
Type
IKA40-40 IKA40-40 IKA63-40 IKA63-40
IKA40-31 IKA40-31 IKA63-31 IKA63-31
IKA40-30 IKA40-30 IKA63-30 IKA63-30
IKA40-22 IKA40-22 IKA63-22 IKA63-22
IKA40-04 IKA40-04 IKA63-04 IKA63-04
Rated
current I
40 A 40 A 63 A 63 A
40 A 40 A 63 A 63 A
40 A 40 A 63 A 63 A
40 A 40 A 63 A 63 A
40 A 40 A 63 A 63 A
Control voltage
at 50/60 Hz
e
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
AC-1 acc. to IEC/EN 60947-4-1 (4-pole, 2 modules)
Type
IK21-10
IK21-10
Rated
current I
20 A
20 A
Control voltage
at 50/60 Hz
e
220-240 V
24 V
Wiring diagram
1
3
A1
2
1
2
1 365
2
1
R3
R4
2
R4
6
4
5
3
4
4
R5
R6
R5
A2
A1
A2
A1
A2
A1
A2
A1 R1 R3
A2 R2
Wiring diagram
1
5
3
A1
2 4
A2
6
63 A
Ordering No.
75
8
R7
R86
30.045.518
30.045.595
30.045.522
30.045.711
30.045.597
30.045.598
30.045.533
30.045.599
30.045.517
30.045.600
30.045.521
30.045.601
7
8
R7
R8R6
30.045.519
30.045.602
30.045.523
30.045.603
30.045.511
30.045.604
30.045.605
30.045.606
Ordering No.
13
14
30.041.246
30.041.289
Weight
(g)
350 350 350 350
350 350 350 350
340 340 340 340
350 350 350 350
350 350 350 350
Weight
(g)
170
170
Packaging
(pcs)
Packaging
(pcs)
AC
5
5
5
5
5
20 A
SLIM CASE
AC
10
IK21-01
IK21-01
20 A
20 A
220-240 V
24 V
AC-1 acc. to IEC/EN 60947-4-1 (2-pole, 1 module)
Type
IKD20-20
IKD20-20
IKD225-20
IKD225-20
IKD232-20
IKD232-20
IKD20-11
IKD20-11
IKD225-11
IKD225-11
IKD232-11
IKD232-11
Rated
current I
20 A
20 A
25 A
25 A
32 A
32 A
20 A
20 A
25 A
25 A
32 A
32 A
Control voltage
at 50/60 Hz
e
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
1
3
A1
4
A2 2
6
Wiring diagram
3
1
A1
4
2
A2
1
R3
A1
R4
2
A2
215
30.041.245
170
10
22
30.041.249
Ordering No.
30.046.006
30.046.024
30.046.860
30.046.861
30.046.862
30.046.863
30.046.011
30.046.025
30.046.864
30.046.865
30.046.866
30.046.867
170
Weight
(g)
130
130
130
130
130
130
130
130
130
130
130
130
Packaging
(pcs)
6
6
AC
DC
32 A
HUM-FREE
Other control voltages are on request - define type and voltage
3
Page 5
Installation Contactors
up to 32 A
AC-1 acc. to IEC/EN 60947-4-1 (2-pole, 1 module)
Type
IKD20-10
IKD20-10
IKD225-10
IKD225-10
IKD232-10
IKD232-10
IKD20-01
IKD20-01
IKD225-01
IKD225-01
IKD232-01
IKD232-01
IKD20-02
IKD20-02
IKD225-02
IKD225-02
IKD232-02
IKD232-02
Rated
current I
20 A
20 A
25 A
25 A
32 A
32 A
20 A
20 A
25 A
25 A
32 A
32 A
20 A
20 A
25 A
25 A
32 A
32 A
Control voltage
at 50/60 Hz
e
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
Wiring diagram
1
A1
2
A2
A1 R1
R2
A2
R3
A1
R1
R4
R2
A2
Ordering No.
30.046.868
30.046.590
30.046.869
30.046.870
30.046.871
30.046.872
30.046.873
30.046.874
30.046.875
30.046.876
30.046.877
30.046.878
30.046.012
30.046.026
30.046.879
30.046.880
30.046.881
30.046.882
Weight
(g)
125
125
125
125
125
125
125
125
125
125
125
125
130
130
130
130
130
130
Packaging
(pcs)
6
6
6
AC
HUM-FREE
DC
AC-1 acc. to IEC/EN 60947-4-1 (4-pole, 2 modules)
Type
IKD25-40
IKD25-40
IKD432-40
IKD432-40
IKD25-31
IKD25-31
IKD432-31
IKD432-31
IKD25-30
IKD25-30
IKD432-30
IKD432-30
Other control voltages are on request - define type and voltage
Rated
current I
25 A
25 A
32 A
32 A
25 A
25 A
32 A
32 A
25 A
25 A
32 A
32 A
Control voltage
at 50/60 Hz
e
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
Wiring diagram
1
3
A1
2
1
2
1 365
2
6
4
5
3
4
4
A2
A1
A2
A1
A2
AC
HUM-FREE
Ordering No.
30.046.008
75
8
30.046.031
30.046.883
30.046.884
30.046.016
R7
R86
30.046.032
30.046.885
30.046.886
30.046.887
30.046.888
30.046.889
30.046.890
Weight
(g)
250
250
250
250
250
250
250
250
245
245
245
245
Packaging
(pcs)
3
3
3
DC
4
Page 6
Installation Contactors
from 32 A up to 63 A
AC-1 acc. to IEC/EN 60947-4-1 (4-pole, 2 modules)
Type
IKD25-22
IKD25-22
IKD432-22
IKD432-22
IKD25-04
IKD25-04
IKD432-04
IKD432-04
Rated
current I
25 A
25 A
32 A
32 A
25 A
25 A
32 A
32 A
Control voltage
at 50/60 Hz
e
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
230 V AC 220 V DC
24 V AC/DC
AC-1 acc. to IEC/EN 60947-4-1 (4-pole, 3 modules)
Type
IK40-40
IK40-40
IK63-40
IK63-40
IK40-31
IK40-31
IK63-31
IK63-31
IK40-30
IK40-30
IK63-30
IK63-30
IK40-22
IK40-22
IK63-22
IK63-22
IK40-04
IK40-04
IK63-04
IK63-04
Rated
current I
40 A
40 A
63 A
63 A
40 A
40 A
63 A
63 A
40 A
40 A
63 A
63 A
40 A
40 A
63 A
63 A
40 A
40 A
50 A
50 A
Control voltage
at 50/60 Hz
e
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
Wiring diagram
1
R3
A1
A2
A1 R1 R3
A2 R2
R5
R4
R6
2
R5
R4
Wiring diagram
1
3
A1
2
1
2
2
1
2
R4
6
4
5
3
4
1 365
4
R3
R5
R4
R6
R5
A2
A1
A2
A1
A2
A1
A2
A1 R1 R3
A2 R2
32 A
AC
Ordering No.
30.046.017
7
8
30.046.033
30.046.891
30.046.892
30.046.018
R7
R8R6
30.046.034
30.046.893
30.046.894
Weight
(g)
250
250
250
250
250
250
250
250
Packaging
(pcs)
3
3
DC
63 A
AC
Ordering No.
30.045.010
75
8
30.045.022
30.045.011
30.045.187
30.045.086
R7
R86
30.045.485
30.045.087
30.045.234
30.045.268
30.045.607
30.045.608
30.045.609
30.045.150
7
8
30.045.172
30.045.235
30.045.233
30.045.145
R7
R8R6
30.045.232
30.045.610
30.045.611
Weight
(g)
420
420
420
420
420
420
420
420
410
410
410
410
420
420
420
420
420
420
420
420
Packaging
(pcs)
5
5
5
5
5
DC
HUM-FREE
HUM-FREE
Other control voltages are on request - define type and voltage
Ordering data
IKA63 – 40 / 12 V
Control voltage
Version of contacts
Basic type
5
Page 7
Installation Contactors with Manual Control
up to 32 A
IKA*-R and IKD*-R are upgraded version of basic types of contactors. Besides basic functions they enable manual control with a handle. Description of the handle position: A: the contactor functions as an installation
contactor without manual control 0: permanently switched off control voltage I: at manual shifting the handle from position
A to I causes the contactor to close;
when control voltage is applied, the handle is
automatically set to position A.
Contactor with manual control enable:
switching demending on tariff (selection of the most convenient tariff) switching when control voltage is not applied
AC-1 acc. to IEC/EN 60947-4-1 (2-pole, 1 module)
Type
IKA20-20-R IKA20-20-R IKA225-20-R IKA225-20-R IKA232-20-R IKA232-20-R
IKA20-11-R IKA20-11-R IKA225-11-R IKA225-11-R IKA232-11-R IKA232-11-R
IKA20-10-R IKA20-10-R IKA225-10-R IKA225-10-R IKA232-10-R IKA232-10-R
IKA20-01-R IKA20-01-R IKA225-01-R IKA225-01-R IKA232-01-R IKA232-01-R
IKA20-02-R IKA20-02-R IKA225-02-R IKA225-02-R IKA232-02-R IKA232-02-R
Rated
current I
20 A 20 A 25 A 25 A 32 A 32 A
20 A 20 A 25 A 25 A 32 A 32 A
20 A 20 A 25 A 25 A 32 A 32 A
20 A 20 A 25 A 25 A 32 A 32 A
20 A 20 A 25 A 25 A 32 A 32 A
Control voltage
at 50/60 Hz
e
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
Wiring diagram
3
1
A1
4
2
A2
1
R3
A1
R4
2
A2
1
A1
2
A2
A1 R1
R2
A2
R3
A1
R1
R4
R2
A2
Ordering No.
30.046.265
30.046.268
30.046.895
30.046.896
30.046.897
30.046.898
30.046.266
30.046.269
30.046.899
30.046.900
30.046.901
30.046.902
30.046.496
30.046.903
30.046.904
30.046.905
30.046.906
30.046.907
30.046.908
30.046.909
30.046.910
30.046.911
30.046.912
30.046.913
30.046.267
30.046.270
30.046.914
30.046.915
30.046.916
30.046.917
Weight
(g)
130 130 130 130 130 130
130 130 130 130 130 130
125 125 125 125 125 125
125 125 125 125 125 125
130 130 130 130 130 130
Packaging
(pcs)
6
6
6
6
6
AC
Other control voltages are on request - define type and voltage
6
Page 8
AC-1 acc. to IEC/EN 60947-4-1 (4-pole, 2 module)
Type
IKA25-40-R IKA25-40-R IKA432-40-R IKA432-40-R
IKA25-31-R IKA25-31-R IKA432-31-R IKA432-31-R
IKA25-30-R IKA25-30-R IKA432-30-R IKA432-30-R
IKA25-22-R IKA25-22-R IKA432-22-R IKA432-22-R
IKA25-04-R IKA25-04-R IKA432-04-R IKA432-04-R
Rated
current I
25 A 25 A 32 A 32 A
25 A 25 A 32 A 32 A
25 A 25 A 32 A 32 A
25 A 25 A 32 A 32 A
25 A 25 A 32 A 32 A
Control voltage
at 50/60 Hz
e
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
230 V
24 V
Installation Contactors with Manual Control
up to 32 A
AC
(pcs)
3
3
3
3
3
Wiring diagram
1
3
A1
2
1
2
1 365
2
1
R4
2
R4
6
4
5
3
4
4
R3
R5
R6
R5
A2
A1
A2
A1
A2
A1
A2
A1 R1 R3
A2 R2
Ordering No.
75
8
R7
R86
30.046.271
30.046.275
30.046.918
30.046.919
30.046.272
30.046.276
30.046.920
30.046.921
30.046.922
30.046.923
30.046.924
30.046.925
7
8
R7
R8R6
30.046.273
30.046.277
30.046.926
30.046.927
30.046.274
30.046.278
30.046.928
30.046.929
Weight
(g)
230 230 230 230
230 230 230 230
225 225 225 225
230 230 230 230
230 230 230 230
Packaging
AC-1 acc. to IEC/EN 60947-4-1 (2-pole, 1 module)
Type
IKD20-20-R
IKD20-20-R
IKD225-20-R
IKD225-20-R
IKD232-20-R
IKD232-20-R
IKD20-11-R
IKD20-11-R
IKD225-11-R
IKD225-11-R
IKD232-11-R
IKD232-11-R
IKD20-10-R
IKD20-10-R
IKD225-10-R
IKD225-10-R
IKD232-10-R
IKD232-10-R
Rated
current I
20 A
20 A
25 A
25 A
32 A
32 A
20 A
20 A
25 A
25 A
32 A
32 A
20 A
20 A
25 A
25 A
32 A
32 A
Control voltage
at 50/60 Hz
e
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
Wiring diagram
3
1
A1
4
2
A2
1
R3
A1
R4
2
A2
1
A1
2
A2
Ordering No.
30.046.381
30.046.506
30.046.930
30.046.931
30.046.932
30.046.933
30.046.507
30.046.508
30.046.934
30.046.935
30.046.936
30.046.937
30.046.938
30.046.939
30.046.940
30.046.941
30.046.942
30.046.943
Weight
(g)
130
130
130
130
130
130
130
130
130
130
130
130
125
125
125
125
125
125
Packaging
(pcs)
6
6
6
AC
HUM-FREE
DC
Other control voltages are on request - define type and voltage
7
Page 9
Installation Contactors with Manual Control
up to 32 A
AC-1 acc. to IEC/EN 60947-4-1 (2-pole, 1 module)
Type
IKD20-01-R
IKD20-01-R
IKD225-01-R
IKD225-01-R
IKD232-01-R
IKD232-01-R
IKD20-02-R
IKD20-02-R
IKD225-02-R
IKD225-02-R
IKD232-02-R
IKD232-02-R
Rated
current I
20 A
20 A
25 A
25 A
32 A
32 A
20 A
20 A
25 A
25 A
32 A
32 A
Control voltage
at 50/60 Hz
e
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
AC-1 acc. to IEC/EN 60947-4-1 (4-pole, 2 modules)
Type
IKD25-40-R
IKD25-40-R
IKD432-40-R
IKD432-40-R
IKD25-31-R
IKD25-31-R
IKD432-31-R
IKD432-31-R
IKD25-30-R
IKD25-30-R
IKD432-30-R
IKD432-30-R
IKD25-22-R
IKD25-22-R
IKD432-22-R
IKD432-22-R
IKD25-04-R
IKD25-04-R
IKD432-04-R
IKD432-04-R
Rated
current I
25 A
25 A
32 A
32 A
25 A
25 A
32 A
32 A
25 A
25 A
32 A
32 A
25 A
25 A
32 A
32 A
25 A
25 A
32 A
32 A
Control voltage
at 50/60 Hz
e
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
230 V AC
220 V DC
24 V AC/DC
Wiring diagram
A1 R1
R2
A2
R3
A1
R1
R4
R2
A2
Wiring diagram
1
3
A1
2
1
2
2
1
2
R4
6
4
5
3
4
1 365
4
R3
R5
R4
R6
R5
A2
A1
A2
A1
A2
A1
A2
A1 R1 R3
A2 R2
Ordering No.
30.046.944
30.046.945
30.046.946
30.046.947
30.046.948
30.046.949
30.046.950
30.046.951
30.046.952
30.046.953
30.046.954
30.046.955
Ordering No.
30.046.509
75
8
30.046.510
30.046.956
30.046.957
30.046.958
R7
R86
30.046.959
30.046.960
30.046.961
30.046.962
30.046.963
30.046.964
30.046.965
30.046.966
7
8
30.046.967
30.046.968
30.046.969
30.046.970
R7
R8R6
30.046.971
30.046.972
30.046.973
Other control voltages are on request - define type and voltage
Weight
(g)
125
125
125
125
125
125
130
130
130
130
130
130
Weight
(g)
250
250
250
250
250
250
250
250
245
245
245
245
250
250
250
250
250
250
250
250
Packaging
(pcs)
6
6
Packaging
(pcs)
3
3
3
3
3
AC
AC
HUM-FREE
DC
HUM-FREE
DC
Ordering data
IKA20 – 20 – R / 12 V
8
Control voltage
Manual control
Version of contacts
Basic type
Page 10
Installation Contactors with Manual Momentary Control
up to 32 A
IKA*-T and IKD*-T are upgraded version of basic types of contactors. Besides basic functions they enable manual control with a handle. Description of the handle position: A: the contactor functions as an installation
contactor 0: permanently switched off control voltage I: momentary switch-on depending of manual activation
AC-1 acc. to IEC/EN 60947-4-1 (2-pole, 1 module)
Type
IKA20-20-T IKA225-20-T IKA232-20-T
IKA20-11-T IKA225-11-T IKA232-11-T
IKA20-10-T IKA225-10-T IKA232-10-T
IKA20-01-T IKA225-01-T IKA232-01-T
IKA20-02-T IKA225-02-T IKA232-02-T
Rated
current I
20 A 25 A 32 A
20 A 25 A 32 A
20 A 25 A 32 A
20 A 25 A 32 A
20 A 25 A 32 A
Control voltage
at 50/60 Hz
e
230 V 230 V 230 V
230 V 230 V 230 V
230 V 230 V 230 V
230 V 230 V 230 V
230 V 230 V 230 V
AC-1 acc. to IEC/EN 60947-4-1 (4-pole, 2 modules)
Type
IKA25-40-T
IKA432-40-T
Rated
current I
25 A
32 A
Control voltage
at 50/60 Hz
e
230 V
230 V
Wiring diagram
3
1
A1
4
2
A2
1
R3
A1
R4
2
A2
1
A1
2
A2
A1 R1
R2
A2
R3
A1
R1
R4
R2
A2
Wiring diagram
1
3
A1
A2
6
4
2
75
8
Ordering No.
30.046.974
30.046.975
30.046.976
30.046.977
30.046.978
30.046.979
30.046.980
30.046.981
30.046.982
30.046.983
30.046.984
30.046.985
30.046.986
30.046.987
30.046.988
Ordering No.
30.046.989
30.046.990
Weight
(g)
130 130 130
130 130 130
125 125 125
125 125 125
130 130 130
Weight
(g)
230
230
Packaging
(pcs)
6
6
6
6
6
Packaging
(pcs)
3
AC
AC
IKA25-31-T
IKA432-31-T
IKA25-30-T
IKA432-30-T
IKA25-22-T
IKA432-22-T
IKA25-04-T
IKA432-04-T
Other control voltages are on request - define type and voltage
25 A
32 A
25 A
32 A
25 A
32 A
25 A
32 A
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
1
A1
A2
2
A1
A2
1
A1
2
A2
A1 R1 R3
A2 R2
5
3
4
1 365
4
2
R3
R5
R4
R6
R5
R4
R7
30.046.991
230
3
R86
30.046.992
30.046.993
230
225
3
30.046.994
7
30.046.995
225
230
3
8
R7
30.046.996
30.046.997
230
230
3
R8R6
30.046.998
230
9
Page 11
Installation Contactors with Manual Momentary Control
up to 32 A
AC-1 acc. to IEC/EN 60947-4-1 (2-pole, 1 module)
Type
IKD20-20-T
IKD225-20-T
IKD232-20-T
IKD20-11-T
IKD225-11-T
IKD232-11-T
IKD20-10-T
IKD225-10-T
IKD232-10-T
IKD20-01-T
IKD225-01-T
IKD232-01-T
IKD20-02-T
IKD225-02-T
IKD232-02-T
Rated
current I
20 A
25 A
32 A
20 A
25 A
32 A
20 A
25 A
32 A
20 A
25 A
32 A
20 A
25 A
32 A
Control
voltage at 50 Hz
e
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
Wiring diagram
3
1
A1
4
2
A2
1
R3
A1
R4
2
A2
1
A1
2
A2
A1 R1
R2
A2
R3
A1
R1
R4
R2
A2
Ordering No.
30.046.999
30.047.000
30.047.001
30.047.002
30.047.003
30.047.004
30.047.005
30.047.006
30.047.007
30.047.008
30.047.009
30.047.010
30.047.011
30.047.012
30.047.013
Weight
(g)
130
130
130
130
130
130
125
125
125
125
125
125
130
130
130
Packaging
(pcs)
6
6
6
6
6
AC
HUM-FREE
DC
AC-1 acc. to IEC/EN 60947-4-1 (4-pole, 2 modules)
Type
IKD25-40-T
IKD432-40-T
IKD25-31-T
IKD432-31-T
IKD25-30-T
IKD432-30-T
IKD25-22-T
IKD432-22-T
IKD25-04-T
IKD432-04-T
Rated
current I
25 A
32 A
25 A
32 A
25 A
32 A
25 A
32 A
25 A
32 A
Control voltage
at 50/60 Hz
e
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
230 V AC
220 V DC
Ordering data
IKA20 – 20 – T / 12 V
Control voltage
Manual momentary control
Version of contacts
Basic type
Wiring diagram
1
3
A1
2
1
2
2
1
2
1
2
6
4
5
3
4
1 365
4
R3
R5
R4
R6
R3
R5
R4
R6
A2
A1
A2
A1
A2
A1
A2
A1
A2
75
Ordering No.
30.047.014
Weight
(g)
250
Packaging
(pcs)
3
8
R7
30.047.015
30.047.016
250
250
3
R86
30.047.017
30.047.018
250
245
3
30.047.019
7
30.047.020
245
250
3
8
7
30.047.021
30.047.022
250
250
3
8
Other control voltages are on request - define type and voltage
30.047.023
250
AC
HUM-FREE
DC
10
Page 12
UL/CSA Installation Contactors
from 20 A up to 63 A
Special designed installation contactors for markets who required UL and CSA approval.
R
General Use acc. to UL 60947-4-1 (2-pole, 1 module)
Type
IKA220-20 IKA220-20 IKA220-20
IKA220-11 IKA220-11 IKA220-11 IKA220-10 IKA220-10 IKA220-10
IKA220-01 IKA220-01 IKA220-01 IKA220-02 IKA220-02 IKA220-02
Rated
current I
20 A
20 A
20 A
20 A
20 A
Control voltage
at 50/60 Hz
e
230 V 120 V
24 V
230 V 120 V
24 V 230 V 120 V
24 V 230 V
120 V
24 V 230 V 120 V
24 V
General Use acc. to UL 60947-4-1 (4-pole, 2 modules)
Type
IKA425-40 IKA425-40 IKA425-40
IKA425-31 IKA425-31 IKA425-31
IKA425-30 IKA425-30 IKA425-30
IKA425-22 IKA425-22 IKA425-22
IKA425-04 IKA425-04 IKA425-04
Rated
current I
25 A
25 A
25 A
25 A
25 A
Control voltage
at 50/60 Hz
e
230 V 120 V
24 V 230 V
120 V
24 V 230 V
120 V
24 V 230 V
120 V
24 V 230 V
120 V
24 V
Wiring diagram
3
1
A1
4
2
A2
1
R3
A1
R4
2
A2
1
A1
2
A2
A1 R1
R2
A2
R3
A1
R1
R4
R2
A2
Wiring diagram
1
3
A1
2
1
2
2
1
2
R4
6
4
5
3
4
1 365
4
R3
R5
R4
R6
R5
A2
A1
A2
A1
A2
A1
A2
A1 R1 R3
A2 R2
20 A
Ordering No.
30.046.825
30.047.024
30.047.025
30.047.289
30.047.026
30.047.027
30.047.290
30.047.028
30.047.029
30.047.291
30.047.030
30.047.031
30.047.291
30.047.032
30.047.033
Weight
(g)
130 130 130
130 130 130 130 125 125
130 125 125 130 130 130
Packaging
(pcs)
AC
6
6
6
6
6
25 A
Ordering No.
75
30.046.827
30.047.034
8
R7
30.047.035
30.047.293
30.047.036
R86
30.047.037
30.047.294
30.047.038
30.047.039
7
30.047.295
30.047.040
8
R7
30.047.041
30.047.296
30.047.042
R8R6
30.047.043
Weight
(g)
230 230 230
230 230 230
225 225 225
230 230 230
230 230 230
Packaging
(pcs)
AC
3
3
3
3
3
Other control voltages are on request - define type and voltage
11
Page 13
UL/CSA Installation Contactors
from 20 A up to 63 A
General Use acc. to UL 60947-4-1 (4-pole, 3 modules)
Type
IKA440-40 IKA440-40 IKA440-40 IKA463-40 IKA463-40 IKA463-40
IKA440-31 IKA440-31 IKA463-31 IKA463-31 IKA463-31 IKA463-31
IKA440-30 IKA440-30 IKA463-30 IKA463-30 IKA463-30 IKA463-30
IKA440-22 IKA440-22 IKA463-22 IKA463-22 IKA463-22 IKA463-22
IKA440-04 IKA440-04 IKA463-04 IKA463-04 IKA463-04 IKA463-04
Rated
current I
40 A 40 A 40 A 63 A 63 A 63 A
40 A 40 A 40 A 63 A 63 A 63 A
40 A 40 A 40 A 63 A 63 A 63 A
40 A 40 A 40 A 63 A 63 A 63 A
40 A 40 A 40 A 63 A 63 A 63 A
Control voltage
at 50/60 Hz
e
230 V 120 V
24 V 230 V 120 V
24 V
230 V 120 V
24 V 230 V 120 V
24 V
230 V 120 V
24 V 230 V 120 V
24 V
230 V 120 V
24 V 230 V 120 V
24 V
230 V 120 V
24 V 230 V 120 V
24 V
Wiring diagram
1
3
A1
2
1
2
1 365
2
1
2
R4
6
4
5
3
4
4
R3
R5
R4
R6
R5
A2
A1
A2
A1
A2
A1
A2
A1 R1 R3
A2 R2
63 A
Ordering No.
30.045.700
75
8
30.045.612
30.045.613
30.045.592
30.045.614
30.045.615
30.045.701
R7
R86
30.045.616
30.045.617
30.045.702
30.045.618
30.045.619
30.045.703
30.045.620
30.045.621
30.045.704
30.045.622
30.045.623
30.045.705
7
8
30.045.624
30.045.625
30.045.706
30.045.626
30.045.627
30.045.707
R7
R8R6
30.045.628
30.045.629
30.045.708
30.045.630
30.045.631
Weight
(g)
350 350 350 350 350 350
350 350 350 350 350 350
340 340 340 340 340 340
350 350 350 350 350 350
350 350 350 350 350 350
Packaging
(pcs)
AC
5
5
5
5
5
General Use acc. to UL 60947-4-1 (2-pole, 1 module)
Type
IKD220-20
IKD220-20
IKD220-20
IKD220-11
IKD220-11
IKD220-11
IKD220-10
IKD220-10
IKD220-10
IKD220-01
IKD220-01
IKD220-01
IKD220-02
IKD220-02
IKD220-02
Rated
current I
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Control voltage
at 50/60 Hz
e
230 V AC 220 V DC 120 V AC 110 V DC
24 V AC/DC
230 V AC 220 V DC 120 V AC 110 V DC
24 V AC/DC
230 V AC 220 V DC 120 V AC 110 V DC
24 V AC/DC
230 V AC 220 V DC 120 V AC 110 V DC
24 V AC/DC
230 V AC 220 V DC 120 V AC 110 V DC
24 V AC/DC
Wiring diagram
3
1
A1
4
2
A2
1
R3
A1
R4
2
A2
1
A1
2
A2
A1 R1
R2
A2
R3
A1
R1
R4
R2
A2
Ordering No.
30.046.826
30.047.044
30.047.045
30.047.297
30.047.046
30.047.047
30.047.298
30.047.048
30.047.049
30.047.299
30.047.050
30.047.051
30.047.300
30.047.052
30.047.053
Weight
(g)
130
130
130
130
130
130
125
125
125
125
125
125
130
130
130
Packaging
(pcs)
6
6
6
6
6
AC
DC
20 A
HUM-FREE
Other control voltages are on request - define type and voltage
12
Page 14
UL/CSA Installation Contactors
from 20 A up to 63 A
General Use acc. to UL 60947-4-1 (4-pole, 2 modules)
Type
IKD425-40
IKD425-40
IKD425-40
IKD425-31
IKD425-31
IKD425-31
IKD425-30
IKD425-30
IKD425-30
IKD425-22
IKD425-22
IKD425-22
IKD425-04
IKD425-04
IKD425-04
Rated
current I
25 A
25 A
25 A
25 A
25 A
25 A
25 A
25 A
25 A
25 A
25 A
25 A
25 A
25 A
25 A
Control voltage
at 50/60 Hz
e
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
120 V AC
110 V DC
120 V AC
110 V DC
24 V AC/DC
Wiring diagram
1
3
A1
2
1
2
2
1
2
R4
6
4
5
3
4
1 365
4
R3
R5
R4
R6
R5
A2
A1
A2
A1
A2
A1
A2
A1 R1 R3
A2 R2
25 A
AC
Ordering No.
75
8
30.046.828
30.047.054
30.047.055
R7
R86
30.047.301
30.047.056
30.047.057
30.047.302
30.047.058
30.047.059
30.047.303
7
8
R7
R8R6
30.047.060
30.047.061
30.047.062
30.047.062
30.047.063
Weight
(g)
250
250
250
250
250
250
245
245
245
250
250
250
250
250
250
Packaging
(pcs)
6
6
6
6
6
DC
HUM-FREE
General Use acc. to UL 60947-4-1 (4-pole, 3 modules)
Type
IKD440-40
IKD440-40
IKD440-40
IKD463-40
IKD463-40
IKD463-40
IKD440-31
IKD440-31
IKD440-31
IKD463-31
IKD463-31
IKD463-31
IKD440-30
IKD440-30
IKD440-30
IKD463-30
IKD463-30
IKD463-30
Rated
current I
40 A
40 A
40 A
63 A
63 A
63 A
40 A
40 A
40 A
63 A
63 A
63 A
40 A
40 A
40 A
63 A
63 A
63 A
Control voltage
at 50/60 Hz
e
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
Wiring diagram
1
3
A1
2
1
2
2
6
4
5
3
4
1 365
4
A2
A1
A2
A1
A2
63 A
AC
Ordering No.
30.045.709
30.045.632
75
8
30.045.633
30.045.593
30.045.634
30.045.635
30.045.710
30.045.636
R7
R86
30.045.637
30.045.711
30.045.638
30.045.639
30.045.712
30.045.640
30.045.641
30.045.713
30.045.642
30.045.643
Weight
(g)
420
420
420
420
420
420
420
420
420
420
420
420
410
410
410
410
410
410
Packaging
(pcs)
5
5
5
DC
HUM-FREE
Other control voltages are on request - define type and voltage
13
Page 15
UL/CSA Installation Contactors
from 20 A up to 63 A
General Use acc. to UL 60947-4-1 (4-pole, 3 modules)
Type
IKD440-22
IKD440-22
IKD440-22
IKD463-22
IKD463-22
IKD463-22
IKD440-04
IKD440-04
IKD440-04
Rated
current I
40 A
40 A
40 A
63 A
63 A
63 A
40 A
40 A
40 A
Control voltage
at 50/60 Hz
e
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
230 V AC
220 V DC
120 V AC
110 V DC
24 V AC/DC
Ordering data
IKA440 – 40 / 12 V
Control voltage
Wiring diagram
1
R3
A1
A2
A1 R1 R3
A2 R2
R5
R4
R6
2
R5
R4
63 A
AC
Ordering No.
30.045.714
7
8
R7
R8R6
30.045.644
30.045.645
30.045.715
30.045.646
30.045.647
30.045.594
30.045.648
30.045.649
Weight
(g)
420
420
420
420
420
420
420
420
420
Other control voltages are on request - define type and voltage
Packaging
(pcs)
5
5
DC
HUM-FREE
Sealing cover for 2-pole, 1 module
Type
IK20-PP
Ordering No.
37.425.061
Sealing cover for 4-pole, 2 modules
Type
IK25-PP
Ordering No.
37.425.062
Version of contacts
Basic type
Installation Contactors
Accessories
Weight
(g)
1
Weight
(g)
2
Packaging
(pcs)
2
Packaging
(pcs)
2
Sealing cover for 4-pole, 3 modules
Type
IK40/63-PP
Ordering No.
37.423.463
14
Weight
(g)
3
Packaging
(pcs)
2
Page 16
Ventilation modul
Installation Contactors
Accessories
Type
IKV
Ordering No.
37.425.296
Weight
(g)
13
Auxilliary switch AC-15 acc. to IEC/EN 60947-5-1 (2-pole, module)
Type
IKN20 IKN11 IKN10 IKN01 IKN02
Rated
current I
6 A 6 A 6 A 6 A 6 A
-20
e
4333
44
34
Auxilliary switch Ratings acc. to UL 508 (2-pole, module)
Type
IKN20UL IKN11UL IKN02UL
Rating code
C300, Q300 C300, Q300 C300, Q300
Packaging
(pcs)
1
Wiring diagram
-11 -01 -10
31
4331
44
32
32
-20
4333
44
34
-02
33
31
41
34
42
32
Wiring diagram
-11
4331
44
32
Ordering No.
38.046.002
38.046.004
38.046.036
38.046.037
38.046.003
-02
31
41
42
32
Weight
(g)
30 30 25 30 30
1
2
Ordering No.
38.046.050
38.046.049
38.046.051
1
2
Packaging
Weight
(pcs)
1
Packaging
(g)
(pcs)
30 30
1
30
4-phase busbars for installation contactors up to 32 A - insulated
Type
L/32-8P L/32-12P L/32-16P L/32-20P L/32-24P
Module
width
4 6
8 10 12
Lenght
(mm)
66
98 138 173 208
Ordering No.
38.046.061
38.046.062
38.046.063
38.046.064
38.046.065
Weight
(g)
60
86 114 141 169
Packaging
(pcs)
10
Single pin terminals for installation contactors up to 32 A - insulated
Type
S/32-1P
Pin
lenght
13.5/32 (total)
Cross-section
rigid/flexible (mm )
6-25/4-16
2
Screw
PZ2
Ordering No.
38.046.066
Weight
(g)
12
Packaging
(pcs)
25
Double pin terminals for installation contactors 40 -63 A - insulated terminals for parallel connection
Type
S/63-2P
Pin
lenght
15
Cross-section
rigid/flexible (mm )
6-50/4-35
2
Screw
PZ2
Ordering No.
38.046.067
Weight
(g)
22
Packaging
(pcs)
25
15
Page 17
Installation Switches and
Installation Momentary Switches
IKS-R installation switches are designed for manual switching of loads with a handle in the same look as the installation contactors.
32 A
AC-21 acc. to IEC/EN 60947-3 (2-pole, 1 module)
Type
IKS220-20-R IKS225-20-R IKS232-20-R
IKS220-11-R IKS225-11-R IKS232-11-R
Rated
current I
20 A 25 A 32 A
20 A 25 A 32 A
e
Wiring diagram
1
3
4
2
Ordering No.
30.047.064
30.047.065
30.047.066
30.047.067
30.047.068
30.047.069
Weight
(g)
55 55 55
55 55 55
Packaging
(pcs)
6
6
AC-21 acc. to IEC/EN 60947-3 (4-pole, 2 modules)
Type
IKS420-40-R IKS425-40-R IKS432-40-R
IKS420-31-R IKS425-31-R IKS432-31-R
IKS420-22-R IKS425-22-R IKS432-22-R
Rated
current I
20 A 25 A 32 A
20 A 25 A 32 A
20 A 25 A 32 A
e
Wiring diagram
1
5
3
7
4
2
1
2
1
2
8
6
75
3
6
8
4
75
3
8
6
4
Ordering No.
30.047.070
30.047.071
30.047.072
30.047.073
30.047.074
30.047.075
30.047.076
30.047.077
30.047.078
Weight
(g)
105 105 105
105 105 105
105 105 105
Packaging
(pcs)
3
3
3
IKS-T installation momentary switches are designed for manual momentary switching of loads with a handle in the same look as the installation contactors.
32 A
AC-21 acc. to IEC/EN 60947-3 (2-pole, 1 module)
Type
IKS220-20-T IKS225-20-T IKS232-20-T
IKS220-11-T IKS225-11-R IKS232-11-T
Rated
current I
20 A 25 A 32 A
20 A 25 A 32 A
e
Wiring diagram
1
3
4
2
1
3
4
2
Ordering No.
30.047.079
30.047.080
30.047.081
30.047.082
30.047.083
30.047.084
Weight
(g)
55 55 55
55 55 55
Packaging
(pcs)
6
6
AC-21 acc. to IEC/EN 60947-3 (4-pole, 2 modules)
Type
IKS420-40-T IKS425-40-T IKS432-40-T
IKS420-31-T IKS425-31-T IKS432-31-T
IKS420-22-T IKS425-22-T IKS432-22-T
Rated
current I
20 A 25 A 32 A
20 A 25 A 32 A
20 A 25 A 32 A
e
Wiring diagram
1
5
3
7
4
2
1
2
1
2
8
6
75
3
6
8
4
75
3
8
6
4
Ordering No.
30.047.085
30.047.086
30.047.087
30.047.088
30.047.089
30.047.090
30.047.091
30.047.092
30.047.093
Weight
(g)
105 105 105
105 105 105
105 105 105
Packaging
(pcs)
3
3
3
16
Page 18
i
Technical characteristics
Dimensions
Page 19
Installation Contactors
up to 25 A
TECHNICAL DATA
Type
Standards Approvals Module width Number of poles Degree of protection Pollution degree Climatic conditions Ambient temperature (open) Storage temperature Maximum altitude
GENERALMAIN CIRCUIT
U and U is reduced for 1.2 % and I for 0.4 % for every additional 100 m
i e e
Number of contactors or switches side-by-side: <40 °C (40 … 55) °C Noise level (operation) Vibration resistance according to IEC/EN 60068-2-6 Shock resistance according to IEC/EN 6068-2-27 Maximum operating frequency with no load Mechanical endurance Weight Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1 coordination type 2 Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-1, AC-7a and AC-21 Operational power for AC-1, AC-7a and AC-21: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-1, AC-7a and AC-21 Electrical endurance for AC-1, AC-7a and AC-21 Rated operational current for AC-2 Operational power for AC-2: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-2 Electrical endurance for AC-2 Rated operational current for AC-22 Operational power for AC-22: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-22 Electrical endurance for AC-22 Rated operational current for AC-3, AC-7b and AC-23 Operational power for AC-3, AC-7b and AC-23: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-3, AC-7b and AC-23 Electrical endurance for AC-3, AC-7b and AC-23
1)
Available approvals only CE
2)
Rated operational voltage between two line (phase) conductors
Symbol
Unit
IK21
IKA20-R IKA20-T
IKD20-R
1)
IKD20-T
IEC/EN 61095, IEC/EN 60947-4-1, IEC/EN 60947-5-1
IKA20 IKD20
CE, EAC
CE, CB, NF, EAC 2 4
IP20 (IP40 when installed in installation box - distribution board)
3
95 % relative humidity °C °C
m
-15 … +55
-30… +80
2000
no limitation
a a
dB
g g
op. c./h
op. c.
g
switched off: 2 (Z and X axis) / switched on: 3 (Z axis) and 1 (X axis)
switched off: 10 (Z and X axis) / switched on: 15 (Z axis) and 2 (X axis)
170
130 130 130 130
20 203030 30
3.000
10.000.000 10.000.0003.000.000 3.000.000
>17 V; >50 mA
mm
W
A
I
A
v
2.0
40
1.7
3.6
1.7
20 20 20
U
V
i
U
kV
imp
U
V
e
Hz
f
I
A
th
I
A
e
P
kW
e
415
4
400
50/60 20 20
4
7.5 13
op. c./h
op. c.
I
A
e
P
kW
e
10
1.5
2.5
600
200.000
12
1.8 2.0
4.5
op. c./h
op. c.
I
A
e
P
kW
e
20
3.7
op. c./h
op. c.
I
A
e
P
kW
e
5
0.37
1.1
120
100.000
300
50.000 NO: 9 / NC: 6
NO: 1.3 / NC: 0.75
2.2
op. c./h
op. c.
3)
Rated operational voltage for versions of contacts -10 and-01 is 230 V
4)
Ambient temperature (open) -25...+55 °C for version with 2NO and 4NO contacts
600
300.000
IKA225 IKD225
IKA225-R
1)
IKA225-T
1 2
4)
max. 3 max. 2
2.0 2.0
72
25
440
2) 3)
400
1)
CE
25 25
5.4
14
25
4.6
IKD225-R IKD225-T
25
1)
18
Page 20
TECHNICAL DATA
Type
Rated operational current for AC-5a (at 230 V) Maximum operating frequency for AC-5a Electrical endurance for AC-5a Rated operational current for AC-5b (at 230 V) Maximum operating frequency for AC-5b Electrical endurance for AC-5b Rated operational current for AC-6a (at 230 V) Maximum operating frequency for AC-6a Electrical endurance for AC-6a Switching of capacitors AC-6b and AC-7c (at 230 V) Maximum operating frequency for AC-6b and AC-7c Electrical endurance for AC-6b and AC-7c Rated operational current for DC-1 (L/R < 1 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-1 Electrical endurance for DC-1 Rated operational current for DC-3 (L/R < 2 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC
MAIN CIRCUITAUXILIARY CIRCUIT
2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-3 Electrical endurance for DC-3 Rated operational current for DC-5 (L/R < 7.5 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-5 Electrical endurance for DC-5 Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1 coordination type 2 Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-15: single-phase 230 V single-phase 400 V Maximum operating frequency for AC-15 Electrical endurance for AC-15 Rated operational current for DC-13: 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC
Installation Contactors
up to 25 A
Symbol
I
e
I
e
I
e
C
I
e
I
e
I
e
S
I
v
U
i
U
imp
U
e
f
I
th
I
e
I
e
Unit
A
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
µF
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
2
mm
mm
Nm
mm
W
A
A
V
kV
V
Hz
A
A
op. c./h
op. c.
A
IK21
IKA20-R IKA20-T
IKD20-R IKD20-T
8.8 600
100.000
8.8 600
100.000
4
600
100.000
30 36
600
100.000
20/12/6/2/0.5 20/15/10/6/0.6 20/15/10/4/1.5 20/20/20/6/2.5 20/20/20/6/3.5
300
100.000
10/5/2/1/0.1 15/8/4/1.3/0.2
20/10/8/4/0.4 20/20/15/6/2.5 20/20/15/6/3.5
300
100.000
10/4/1/0.3/0.06 15/5/3/0.5/0.1
20/8/6/2/0.2
20/20/15/5/1.5
20/20/15/5/3
300
100.000
1 … 2.5 1 … 2.5
9
M3.5
1.2
>17 V; >50 mA
3.6
1.7 1.7
40
IKA20 IKD20
20
20 20
415
4
230/400
50/60
20
6 4
1200 600
200.000
6/4/1/0.3/0.05
6/6/4/1/0.1
6/6/6/3/1
6/6/6/4/2
IKA225 IKD225 IKA225-R IKA225-T
25/16/12/5.5/0.6
1 … 10
1 … 6
PZ1PZ2
2 22
72
25 25
440
300.000
IKD225-R IKD225-T
11.2
9.7
4.8
25/20/15/6/0,6 25/25/20/10/620/18/15/10/6
25/15/10/4/0.4
25
19
4
Page 21
Installation Contactors
up to 25 A
TECHNICAL DATA
Type
Maximum operating frequency for DC-13 Electrical endurance for DC-13 Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation
AUXILIARY CIRCUIT
Screw Screw head Tightening torque Range of control voltage for switch-on Range of control voltage for drop out Kind of voltage Standard control voltages
Frequency of AC control voltage Control mode Impulse duration of control voltage: minimum maximum Minimum duration between two impulses of control voltage Surge immunity withstand voltage 1.2/50 µs acc. to standard IEC/EN 61000-4-5
COIL
Coil consumption: switch-on operation Delays: make brake Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque MTTF - Mean time to failure MTTF = 1/λ = B10/(0.1 n ) MTTF - Mean time to failure dangerous
d
MTTFd = 1/λ = B10 /(0.1 n )
d d op
B10 - Number of operating cycles until 10 % of devices fail
B10 - Number of operating cycles until 10 % of device dangerous
d
B10 = B10/ratio of dangerous failures
d
SAFETY
Ratio of dangerous failures n - Operating cycles (operating cycles/h)
op
op
Symbol
S
U
c
U
c
U
c
f
Unit
op. c./h
op. c.
2
mm
mm
mm
% %
V
Hz
ms
kV
VA/W
ms
2
mm
mm
Nm
h
h
op. c.
op. c.
1/h
1/h
%
op. c./h
IK21
IKA20 IKD20
IKA20-R IKA20-T
IKD20-R IKD20-T
IKA225 IKD225 IKA225-R IKA225-T
300
200.000
1 … 2.5 1 … 2.5
1 … 10
1 … 6
9
M3.5
PZ2 PZ1
1.2
85 ... 110
AC: 75 … 20 / DC: 75 … 10 (where is applicable)
AC/DC AC/DCAC AC
12, 24, 48,
120, 230, 400
50/60 50/60
remote control with U / manual control only for types with -R and -T
c
12, 24, 48, 120, 230
40 … 500 40 … 500
permanent permanent
AC: 150 / DC: 500 (where is applicable)
2
30/25
5/1.5
7 … 20
12/10
2.8/1.2
15 … 25
2.1/2.1 2.1/2.1
2.1/2.1 2.1/2.1
15 … 45
12/10
2.8/1.2
15 … 25
10 … 20 10 … 30 20 … 50 20 … 5010 … 30
1 … 2.5 1 … 2.5
9
7
M3M3.5
PZ1PZ2
1.2
0.6 AC-1: 5.000 AC-3: 7.500 AC-1: 6.666
AC-3: 10.000 AC-1: 150.000 AC-3: 225.000 AC-1: 200.000 AC-3: 300.000
AC-1: 0.0002
AC-3: 0.000133
AC-1: 0.00015
AC-3: 0.0001
75
300
IKD225-R IKD225-T
15 … 45
20
Page 22
TECHNICAL DATA
Type
Standards Approvals Module width Number of poles Degree of protection Pollution degree Climatic conditions Ambient temperature (open) Storage temperature Maximum altitude
GENERALMAIN CIRCUIT
U and U is reduced for 1.2 % and I for 0.4 % for every additional 100 m
i e e
Number of contactors or switches side-by-side: <40 °C (40 … 55) °C Noise level (operation) Vibration resistance according to IEC/EN 60068-2-6 Shock resistance according to IEC/EN 6068-2-27 Maximum operating frequency with no load Mechanical endurance Weight Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1 coordination type 2 Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-1, AC-7a and AC-21 Operational power for AC-1, AC-7a and AC-21: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-1, AC-7a and AC-21 Electrical endurance for AC-1, AC-7a and AC-21 Rated operational current for AC-2 Operational power for AC-2: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-2 Electrical endurance for AC-2 Rated operational current for AC-22 Operational power for AC-22: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-22 Electrical endurance for AC-22 Rated operational current for AC-3, AC-7b and AC-23 Operational power for AC-3, AC-7b and AC-23: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-3, AC-7b and AC-23 Electrical endurance for AC-3, AC-7b and AC-23
1)
Available approvals only CE
2)
Rated operational voltage between two line (phase) conductors
Installation Contactors
up to 32 A
Symbol
Unit
IKA232 IKA232-R IKA232-T
IKD232 IKD232-R IKD232-T
IKA25
IKA25-R IKA25-T
1)
IKD25
IKD25-R
IKD25-T
IEC/EN 61095, IEC/EN 60947-4-1, IEC/EN 60947-5-1
CE, EAC
CE, CB, NF, EAC
1
2
IP20 (IP40 when installed in installation box - distribution board)
3
95 % relative humidity °C °C
m
-15 … +55
-30… +80
2000
max. 3 max. 2
a a
dB
g g
op. c./h
op. c.
g
30 20 20 2030 30
switched off: 2 (Z and X axis) / switched on: 3 (Z axis) and 1 (X axis)
switched off: 10 (Z and X axis) / switched on: 15 (Z axis) and 2 (X axis)
3.000
3.000.000 10.000.000 10.000.000 10.000.0003.000.000 3.000.000 130 130 230 250 250230
>17 V; >50 mA
mm
W
A
I
A
v
U
V
i
U
kV
imp
U
V
e
Hz
f
I
A
th
I
A
e
P
kW
e
2.5 2.5 2.5 2.5
72
2)3)
400
32 32 32 32
7
3.6
2.2 2.2
25
440
4
50/60
25 25
5.4 9
16
op. c./h
op. c.
I
e
P
e
NO: 150.000 / NC: 100.000
A
kW
16
2.4
600
200.000 150.000 14
2
3.6
6
op. c./h
op. c.
I
A
e
P
kW
e
32 32
5.9
120
100.000
25
4.6
8
13.8
op. c./h
op. c.
I
A
e
P
kW
e
NO: 9 / NC: 6
NO: 1.3 / NC: 0.75
op. c./h
op. c.
3)
Rated operational voltage for versions of contacts -10 and-01 is 230 V
4)
Ambient temperature (open) -25...+55 °C for version with 2NO and 4NO contacts
300.000 500.000
300
50.000
600
4)
25
1)
2 4
68
400
8.5
1.3
2.2 4
IKA432 IKA432-R IKA432-T
IKD432
IKD432-R
1)
IKD432-T
1)
CE
32
3232 32
7 12 21
16
2.4
4.1
7.2
5.9
10.2
17.7
21
Page 23
Installation Contactors
up to 32 A
TECHNICAL DATA
Type
Rated operational current for AC-5a (at 230 V) Maximum operating frequency for AC-5a Electrical endurance for AC-5a Rated operational current for AC-5b (at 230 V) Maximum operating frequency for AC-5b Electrical endurance for AC-5b Rated operational current for AC-6a (at 230 V) Maximum operating frequency for AC-6a Electrical endurance for AC-6a Switching of capacitors AC-6b and AC-7c (at 230 V) Maximum operating frequency for AC-6b and AC-7c Electrical endurance for AC-6b and AC-7c Rated operational current for DC-1 (L/R < 1 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-1 Electrical endurance for DC-1 Rated operational current for DC-3 (L/R < 2 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC
MAIN CIRCUITAUXILIARY CIRCUIT
2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-3 Electrical endurance for DC-3 Rated operational current for DC-5 (L/R < 7.5 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-5 Electrical endurance for DC-5 Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1 coordination type 2 Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-15: single-phase 230 V single-phase 400 V Maximum operating frequency for AC-15 Electrical endurance for AC-15 Rated operational current for DC-13: 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC
Symbol
I
e
I
e
I
e
C
I
e
I
e
I
e
S
I
v
U
i
U
imp
U
e
f
I
th
I
e
I
e
Unit
A
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
µF
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
2
mm
mm
Nm
mm
W
A
A
V
kV
V
Hz
A
A
op. c./h
op. c.
A
IKA232 IKA232-R IKA232-T
IKD232-R IKD232-T
13
IKD232
IKA25
IKA25-R IKA25-T
IKD25
IKD25-R
IKD25-T
11.2
IKA432 IKA432-R IKA432-T
IKD432-R IKD432-T
13
600
100.000
11
9.7
11
600
100.000
6 62.8
600
100.000
40 4036
600
100.000
32/25/15/6/0.6 32/32/20/10/6 32/32/20/10/6
25/20/15/6/0.6
25/25/20/10/6 25/25/25/20/15 25/25/25/20/15
32/25/15/6/0.6
32/32/32/20/15 32/32/32/20/15
300
100.000
20/10/4/1.3/0.2
32/18/12/5.5/0.6 32/18/12/5.5/0.6
25/16/12/5.5/0.6
25/25/25/15/3
25/25/25/20/8
20/10/4/1.3/0.215/8/4/1.3/0.2
32/32/25/15/3 32/32/25/20/8
300
100.000
18/6/3/0.5/0.1 15/5/3/0.5/0.1
32/16/10/4/0.4 32/16/10/4/0.4
25/15/10/4/0.4
25/25/20/12/2
25/25/25/15/5
18/6/3/0.5/0.1
32/28/20/12/2 32/32/25/15/5
300
100.000
1 … 10
1 … 6
9
M3.5
PZ1
1.2
>17 V; >50 mA
3.6
2.5 2.5
72
32
32
2.2 2.2
25
25
2.5 2.5
68
32
440
4
230/400
50/60
32 32
25
6 4
600
300.000
500.000
6/4/1/0.3/0.05
6/6/4/1/0.1
6/6/6/3/1
6/6/6/4/2
IKD432
32
22
4
Page 24
TECHNICAL DATA
Type
Maximum operating frequency for DC-13 Electrical endurance for DC-13 Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation
AUXILIARY CIRCUIT
Screw Screw head Tightening torque Range of control voltage for switch-on Range of control voltage for drop out Kind of voltage Standard control voltages
Frequency of AC control voltage Control mode Impulse duration of control voltage: minimum maximum Minimum duration between two impulses of control voltage Surge immunity withstand voltage 1,2/50 µs acc. to standard IEC/EN 61000-4-5
COIL
Coil consumption: switch-on operation Delays: make brake Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque MTTF - Mean time to failure MTTF = 1/λ = B10/(0.1 n ) MTTF - Mean time to failure dangerous
d
MTTFd = 1/λ = B10 /(0.1 n )
d d op
B10 - Number of operating cycles until 10 % of devices fail
B10 - Number of operating cycles until 10 % of device dangerous
d
B10 = B10/ratio of dangerous failures
d
SAFETY
Ratio of dangerous failures n - Operating cycles (operating cycles/h)
op
1)
Coil consumption for version -04 is 3.8 VA/3.8 W
op
Installation Contactors
up to 32 A
Symbol
S
U
c
U
c
U
c
f
Unit
op. c./h
op. c.
2
mm
mm
mm
% %
V
Hz
ms
kV
VA/W
ms
2
mm
mm
Nm
h
h
op. c.
op. c.
1/h
1/h
%
op. c./h
IKA232 IKA232-R IKA232-T
IKD232 IKD232-R IKD232-T
IKA25
IKA25-R IKA25-T
IKD25
IKD25-R
IKD25-T
300
200.000
1 … 10
1 … 6
9
M3.5
PZ1
1.2
85 ... 110
AC: 75 … 20 / DC: 75 … 10 (where is applicable)
AC/DC AC/DCAC AC/DC AC AC
12, 24, 48, 120, 230
50/60 50/60 50/60
40 … 500 40 … 500 40 … 500
remote control with U / manual control only for types with -R and -T
12, 24, 48
120, 230, 400
c
12, 24, 48
120, 230
permanent permanent
AC: 150 / DC: 500 (where is applicable)
2
12/10
2.8/1.2
2.1/2.1
2.1/2.1
15 … 25 15 … 45
33/25 33/25
5.5/1.6 5.5/1.6
10 … 30
2.6/2.6
2.6/2.6
15 … 45
10 … 30 20 … 50 10 … 30
1 … 2.5 1 … 2.5
7
M3
PZ1
0.6
AC-1: 5.000
AC-3: 7.500
AC-3: 12.500
AC-1: 6.666 AC-1: 5.000AC-1: 5.000
AC-3: 10.000
AC-1: 112.500 for NO
AC-3: 225.000
AC-1: 150.000 for NO
AC-1: 150.000
AC-1: 200.000 AC-1: 150.000
AC-3: 16.666
AC-3: 375.000
AC-3: 300.000 AC-3: 500.000
AC-1: 0.000266 for NO
AC-1: 0.0002
AC-3: 0.000133 AC-3: 0.00008
AC-1: 0.0002 for NO
AC-1: 0.00015 AC-1: 0.0002
AC-3: 0.00006AC-3: 0.0001
75
300
IKA432 IKA432-R IKA432-T
12, 24, 48,
120, 230, 400
1)
1)
10 … 30 10 … 30
IKD432 IKD432-R IKD432-T
12, 24, 48,
120, 230
2.6/2.6
2.6/2.6
15 … 45
20 … 7020 … 70
AC-1: 3.750AC-1: 3.750
AC-1: 112.500
AC-1: 0.000266
1)
1)
23
Page 25
Installation Contactors
up to 63 A
TECHNICAL DATA
Type
Standards Approvals Module width Number of poles Degree of protection Pollution degree Climatic conditions Ambient temperature (open) Storage temperature Maximum altitude
GENERALMAIN CIRCUIT
U and U is reduced for 1.2 % and I for 0.4 % for every additional 100 m
i e e
Number of contactors or switches side-by-side: <40 °C (40 … 55) °C Noise level (operation) Vibration resistance according to IEC/EN 60068-2-6 Shock resistance according to IEC/EN 6068-2-27 Maximum operating frequency with no load Mechanical endurance Weight Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1 coordination type 2 Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-1, AC-7a and AC-21 Operational power for AC-1, AC-7a and AC-21: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-1, AC-7a and AC-21 Electrical endurance for AC-1, AC-7a and AC-21 Rated operational current for AC-2 Operational power for AC-2: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-2 Electrical endurance for AC-2 Rated operational current for AC-22 Operational power for AC-22: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-22 Electrical endurance for AC-22 Rated operational current for AC-3, AC-7b and AC-23 Operational power for AC-3, AC-7b and AC-23: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-3, AC-7b and AC-23 Electrical endurance for AC-3, AC-7b and AC-23
1)
I (AC-1) for IK63-04 is 50 A
e
2)
Rated power (AC-1) for IK63-04:
single-phase 230 V = 10.9 kW three-phase 230 V = 18.9 kW three-phase 400 V = 32.9 kW
Symbol
a a
I
v
U
i
U
imp
U
e
f
I
th
I
e
P
e
I
e
P
e
I
e
P
e
I
e
P
e
Unit
IKA40 IK40 IK63IKA63
IEC/EN 61095, IEC/EN 60947-4-1, IEC/EN 60947-5-1
CE, CB, NF, EAC
3 4
IP20 (IP40 when installed in installation box - distribution board)
3
°C °C
m
dB
g g
op. c./h
op. c.
g
95 % relative humidity
-15 … +55
-30… +80
no limitation
max. 3 max. 2 max. 2
30 20 2030
switched off: 2 (Z and X axis) / switched on: 3 (Z axis) and 1 (X axis)
switched off: 10 (Z and X axis) / switched on: 15 (Z axis) and 2 (X axis)
3.000.000 10.000.000 10.000.0003.000.000 350 420 350 420
3)
2000
no limitation no limitationno limitation
3.000
>17 V; >50 mA
mm
W
A
A
4 4
176
63
63
3.6
40 40 63 63
440
6
400
50/60
kV
Hz
kW
V
V
A A
40 63 40
8.7 16 26
op. c./h
op. c.
A
kW
25
3.7
6.5
600
100.000
11.2
op. c./h
op. c.
A
kW
40 63
7.4
12.7
120
50.000
22.2
op. c./h
op. c.
A
kW
22
3.7
5.5
300
50.000
11
op. c./h
op. c.
3)
) Ambient temperature (open) -25...+55 °C for version with 4NO contacts
600
150.000
max. 3
8 8
240
80
1)
63
2)
13.3
2)
24
2)
40
32
4.8
8.3
14.4
11.6
20.1
34.9
30
5
8.5 15
80
24
Page 26
TECHNICAL DATA
Type
Rated operational current for AC-5a (at 230 V) Maximum operating frequency for AC-5a Electrical endurance for AC-5a Rated operational current for AC-5b (at 230 V) Maximum operating frequency for AC-5b Electrical endurance for AC-5b Rated operational current for AC-6a (at 230 V) Maximum operating frequency for AC-6a Electrical endurance for AC-6a Switching of capacitors AC-6b and AC-7c (at 230 V) Maximum operating frequency for AC-6b and AC-7c Electrical endurance for AC-6b and AC-7c Rated operational current for DC-1 (L/R < 1 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-1 Electrical endurance for DC-1 Rated operational current for DC-3 (L/R < 2 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC
MAIN CIRCUITAUXILIARY CIRCUIT
2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-3 Electrical endurance for DC-3 Rated operational current for DC-5 (L/R < 7.5 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-5 Electrical endurance for DC-5 Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1 coordination type 2 Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-15: single-phase 230 V single-phase 400 V Maximum operating frequency for AC-15 Electrical endurance for AC-15 Rated operational current for DC-13: 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC
Installation Contactors
up to 63 A
Symbol
Unit
I
A
e
op. c./h
op. c.
I
A
e
op. c./h
op. c.
I
A
e
op. c./h
op. c.
µF
C
op. c./h
op. c.
I
A
e
op. c./h
op. c.
I
A
e
op. c./h
op. c.
I
A
e
op. c./h
op. c.
mm
2
S
mm
Nm
mm
W
A
I
A
v
U
V
i
U
kV
imp
U
V
e
Hz
f
I
A
th
I
A
e
op. c./h
op. c.
I
A
e
IKA40 IK40 IK63IKA63
20 32
600
100.000
17.6 600
100.000
10.8
17.2
600
100.000
220 330
600
100.000
40/25/18/4/1.2 63/26/20/4/1.2 40/38/32/10/8
40/40/40/30/20
63/42/34/10/8
63/63/60/35/30
40/40/40/40/40 63/63/63/63/63
300
100.000
22/10/5/1.5/0.3 25/11/5/1.5/0.3
40/20/16/5/1
40/40/32/15/4
45/22/18/5/1
63/45/35/18/5
40/40/40/40/10 63/63/63/63/10
300
100.000
20/8/4/1/0.2 25/10/5/1/0.2
40/18/14/5/0.8
40/40/28/12/3
45/20/15/5/0.8
63/44/30/15/4
40/40/40/35/8 63/63/60/45/10
300
100.000
1.5 … 25
1.5 … 16 10
M5
PZ2
3.5
>17 V; >50 mA
3.6
4 4
8 8
176
63
63 80
40 40 63 63
440
4
230/400
50/60
40 63
6 4
1.200
150.000
6/4/1/0.3/0.05
6/6/4/1/0.1
6/6/6/3/1 6/6/6/4/2
22
240
80
25
4
Page 27
Installation Contactors
up to 63 A
TECHNICAL DATA
Type
Maximum operating frequency for DC-13 Electrical endurance for DC-13 Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw
AUXILIARY CIRCUIT
Screw head Tightening torque Range of control voltage for switch-on Range of control voltage for drop out Kind of voltage Standard control voltages
Frequency of AC control voltage Control mode Impulse duration of control voltage: minimum maximum Minimum duration between two impulses of control voltage Surge immunity withstand voltage 1.2/50 μs acc. to standard IEC/EN 61000-4-5
COIL
Coil consumption: switch-on operation Delays: make brake Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque MTTF - Mean time to failure MTTF = 1/λ = B10/(0.1 n ) MTTF - Mean time to failure dangerous
d
MTTFd = 1/λ = B10 /(0.1 n )
d d op
B10 - Number of operating cycles until 10 % of devices fail
B10 - Number of operating cycles until 10 % of device dangerous
d
B10 = B10/ratio of dangerous failures
d
SAFETY
Ratio of dangerous failures n - Operating cycles (operating cycles/h)
op
1)
Coil consumption for version -22 and -04 is 6.1 VA/6.1 W
op
Symbol
S
U
c
U
c
U
c
f
Unit
op. c./h
op. c.
2
mm
mm
mm
% %
V
Hz
ms
kV
VA/W
ms
2
mm
mm
Nm
h
h
op. c.
op. c.
1/h
1/h
%
op. c./h
IKA40 IK40 IK63IKA63
300
200.000
1.5 … 25
1.5 … 16 10
M5
PZ2
3.5
85 ... 110
AC: 75 … 20 / DC: 75 … 10 (where is applicable)
AC ACAC/DC AC/DC
12, 24, 48,
120, 230, 400
50/60 50/60
remote control with U / manual control only for types with -R
12, 24, 48,
120, 230
40 … 500 40 … 500
c
12, 24, 48,
120, 230, 400
permanent permanent
AC: 150 / DC: 500 (where is applicable)
2
15.4/6
7.7/3 7.7/3
10 … 20
5/5 5/5
15 … 20
1)
1)
15.4/6
10 … 20
10 … 15 35 … 45 35 … 4510 … 15
1 … 2.5 1 … 2.5
8
M3
PZ1
0.6 AC-1: 2.500 AC-3: 3.750 AC-1: 3.333 AC-3: 5.000
AC-1: 75.000 AC-3: 112.500 AC-1: 100.000 AC-3: 150.000
AC-1: 0.0004
AC-3: 0.000266
AC-1: 0.0003
AC-3: 0.0002
75
300
12, 24, 48,
120, 230
1)
5/5
1)
5/5
15 … 20
26
Page 28
Installation Contactors UL/CSA
TECHNICAL DATA
Symbol
Type
Standards Approvals Module width Number of poles Degree of protection Pollution degree Ambient temperature (closed) Storage temperature Maximum altitude
U and U is reduced for 1.2 % and I for 0.4 % for every additional 100 m
i e e
GENERALMAIN CIRCUIT
Number of contactors or switches side-by-side: <40 °C (40 … 55) °C Noise level (operation) Vibration resistance according to IEC/EN 60068-2-6 Shock resistance according to IEC/EN 6068-2-27 Maximum operating frequency with no load Mechanical endurance Weight Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1 coordination type 2
Maximum back-up fuse for short-circuit protection KS acc. to UL and CSA
Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-1, AC-7a and AC-21 Operational power for AC-1, AC-7a and AC-21: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-1, AC-7a and AC-21 Electrical endurance for AC-1, AC-7a and AC-21 Rated operational current for AC-2 Operational power for AC-2: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-2 Electrical endurance for AC-2 Rated operational current for AC-22 Operational power for AC-22: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-22 Electrical endurance for AC-22 Rated operational current for AC-3, AC-7b and AC-23 Operational power for AC-3, AC-7b and AC-23: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-3, AC-7b and AC-23 Electrical endurance for AC-3, AC-7b and AC-23
1)
Rated operational voltage between two line (phase) conductors
2)
Rated operational voltage for versions of contacts -10 and-01 is 230 V
3)
Rated voltage 240 V valid in acc. to UL and CSA
4)
Rated voltage 480 V valid in acc. to UL and CSA
5)
Ambient temperature (open) -13 ... 104 °F / -25 ... +40 °C for version with 2NO and 4NO contacts
Unit
m
dB
g
a
g
a
op. c./h
op. c.
g
W
A
I
A
v
I
A
v
U
V
i
U
kV
imp
U
V
e
Hz
f
I
A
th
I
A
e
P
kW
e
op. c./h
op. c.
I
A
e
P
kW
e
op. c./h
op. c.
I
A
e
P
kW
e
op. c./h
op. c.
I
A
e
P
kW
e
op. c./h
op. c.
up to 25 A
IKA220 IKD220
UL 60947-4-1A, C22.2 No. 60947-4-1A-07, IEC/EN 61095, IEC/EN 60947-4-1
CE, UL, CSA
1
2
IP20 (IP40 when installed in installation box - distribution board)
3
5 °F ... 104 °F / -5 °C … +40 °C
5)
-22 °F ... 176 °F / -30 °C … +80 °C
2000
no limitation
30 20 2030
switched off: 2 (Z and X axis) / switched on: 3 (Z axis) and 1 (X axis)
switched off: 10 (Z and X axis) / switched on: 15 (Z axis) and 2 (X axis)
3.000
3.000.000 10.000.000 10.000.0003.000.000 130 130 230 250
>17 V; >50 mA
0.118 in /3.6 mm
1.7 1.7
2 2
72
25 20 20 20 20
25 25
440
1) 2)
440 3)240
4
400/480
50/60
20 25
4
600
200.000
12
1.8
120
100.000
20
3.7
300
50.000
NO: 9 / NC: 6
NO: 1.3 / NC: 0.75
600
300.000 500.000
IKD425IKA425
2 4
68
25
4)
2020
5.4 9
16
14
2
3.6 6
25
4.6 8
13.8
8.5
1.3
2.2 4
27
4
Page 29
Installation Contactors UL/CSA
up to 25 A
TECHNICAL DATA
Symbol
Type
Rated motor power acc. to standards UL and CSA: single-phase 120 V single-phase 208 V single-phase 240 V three-phase 120 V three-phase 208 V three-phase 240 V three-phase 460 V Maximum operating frequency for motors acc. to UL and CSA Electrical endurance for motors according to UL and CSA General use according to standards UL and CSA: single-phase 240 V three-phase 480 V Maximum operating frequency for general use acc. to UL and CSA Electrical endurance for general use acc. to UL and CSA Switching of discharge lamps acc. to standards UL and CSA: single-phase 240 V - standard ballast three-phase 480 V - standard ballast Maximum operating frequency for discharge lamps acc. to UL and CSA Electrical endurance for discharge lamps acc. to UL and CSA Rated operational current for AC-5a (at 230 V) Maximum operating frequency for AC-5a Electrical endurance for AC-5a Rated operational current for AC-5b (at 230 V) Maximum operating frequency for AC-5b Electrical endurance for AC-5b Rated operational current for AC-6a (at 230 V) Maximum operating frequency for AC-6a Electrical endurance for AC-6a Switching of capacitors AC-6b and AC-7c (at 230 V) Maximum operating frequency for AC-6b and AC-7c Electrical endurance for AC-6b and AC-7c
MAIN CIRCUIT
Rated operational current for DC-1 (L/R < 1 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-1 Electrical endurance for DC-1 Rated operational current for DC-3 (L/R < 2 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-3 Electrical endurance for DC-3 Rated operational current for DC-5 (L/R < 7.5 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-5 Electrical endurance for DC-5 Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1
AUXILIARY CIRCUIT
coordination type 2
Unit
IKA220 IKD220
1/3 1/3 3/4
P
HP
e
1 1 1
op. c./h
op. c.
I
A
e
300.000
20
op. c./h
op. c.
I
A
e
20
op. c./h
op. c.
I
A
e
op. c./h
op. c.
I
A
e
op. c./h
op. c.
I
A
e
op. c./h
op. c.
µF
C
op. c./h
op. c.
20/15/10/6/0.6 25/20/15/6/0.6
I
A
e
25/18/15/10/6
op. c./h
op. c.
10/5/2/1/0.1 15/8/4/1.3/0.2
I
A
e
20/10/8/4/0.4
op. c./h
op. c.
10/4/1/0.3/0.06 15/5/3/0.5/0.1
I
A
e
20/8/6/2/0.2
op. c./h
op. c.
S
W
I
A
v
20 20
1/3
3/4 3/4 3/4
1 2 3 5
360
500.000
20
25
360
200.000
20
25
360
100.000
8.8
11.2
600
100.000
8.8 600
100.000
4
600
100.000
30 36
600
100.000
25/25/20/10/6 25/25/25/20/15 25/25/25/20/15
300
100.000
25/10/8/4/0.4
25/25/25/15/3
25/25/25/20/8
300
100.000
25/15/10/4/0.4
25/25/20/12/2
25/25/25/15/5
300
100.000
16 ... 10 AWG / 1 … 10 mm
16 ... 8 AWG / 1 … 6 mm
2
2
0.354 in / 9 mm M3.5
PZ1
10.62 lb-in / 1.2 Nm >17 V; >50 mA
0.118 in /3.6 mm
1.7
72
25
IKD425IKA425
1/3
1 1 2 3 5
25
25
9.7
4.8
2.2
68
25
28
Page 30
Installation Contactors UL/CSA
TECHNICAL DATA
Type
Maximum back-up fuse for short-circuit protection K5 acc. to UL and CSA Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-15: single-phase 230 V single-phase 400 V Maximum operating frequency for AC-15 Electrical endurance for AC-15 Switching of auxiliary loads according to standard UL and CSA Maximum operating frequency for auxiliary loads according to UL and CSA Electrical endurance for auxiliary loads according to UL and CSA Rated operational current for DC-13: 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC
AUXILIARY CIRCUIT
3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-13 Electrical endurance for DC-13 Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque Range of control voltage for switch-on Range of control voltage for drop out Kind of voltage Standard control voltages Frequency of AC control voltage Control mode Impulse duration of control voltage: minimum maximum Minimum duration between two impulses of control voltage Surge immunity withstand voltage 1.2/50 μs acc. to standard IEC/EN 61000-4-5 Coil consumption:
COIL AUXILIARY CIRCUIT
switch-on operation Delays: make brake Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque MTTF - Mean time to failure MTTF = 1/λ = B10/(0.1 n ) MTTF - Mean time to failure dangerous
d
MTTFd = 1/λ = B10 /(0.1 n )
d d op
op
B10 - Number of operating cycles until 10 % of devices fail
B10 - Number of operating cycles until 10 % of device dangerous
d
B10 = B10/ratio of dangerous failures
d
SAFETY
Ratio of dangerous failures n - Operating cycles (operating cycles/h)
op
1)
Coil consumption for contact version -04 is 3.8 VA / 3.8 W
Symbol
U U
U
U
U U
U
I
imp
f
th
I
I
S
f
i
i
e
e
e
c
c
c
Unit
V V
kV
V
Hz
A
A
op. c./h
op. c.
op. c./h
op. c.
A
op. c./h
op. c.
% %
V
Hz
ms
kV
VA/W
ms
h
h
op. c.
op. c.
1/h
1/h
%
op. c./h
up to 25 A
IKA220 IKD220
20 20
440
4
230/400
50/60
20 25
6 4
600
300.000 B300, P300
360
100.000
6/4/1/0.3/0.05
6/6/4/1/0.1
6/6/6/3/1 6/6/6/4/2
300
200.000
16…10 AWG / 1…10 mm
16… 8 AWG / 1…6 mm
0.354 in / 9 mm M3.5
PZ1
10.62 lb-in / 1.2 Nm 85 ... 110
AC: 75 … 20 / DC: 75 … 10 (where is applicable)
AC ACAC/DC AC/DC
12, 24, 48, 110, 120, 127, 208, 230, 240
50/60
remote control with U
permanent permanent
AC: 150 / DC: 500 (where is applicable)
2
12/10
2.8/1.2 5.5/1.6
15 … 25
2.1/2.1
2.1/2.1
15 … 45
10 … 30 20 … 50 20 … 7010 … 30
16 ... 14 AWG / 1 … 2.5 mm 16 ... 14 AWG / 1 … 2.5 mm
0.276 in / 7 mm M3
PZ1
5.31 lb-in / 0.6 Nm General Use: 4.166
Motor: 6.250
General Use: 5.555
Motor: 8.333
General Use: 150.000
Motor: 225.000
General Use: 200.000
Motor: 300.000
General Use: 0.00024
Motor: 0.00016
General Use: 0.00018
Motor: 0.00012
75
360
25 25
500.000
2
2
c
33/25
10 … 30
2
2
Motor: 10.416
Motor: 13.888
Motor: 375.000
Motor: 500.000
Motor: 0.000096
Motor: 0.000072
2.6/2.6
2.6/2.6
IKD425IKA425
1)
1)
15 … 45
29
4
Page 31
Installation Contactors UL/CSA
up to 63 A
TECHNICAL DATA
Symbol
Type
Standards Approvals Module width Number of poles Degree of protection Pollution degree Ambient temperature (open) Storage temperature Maximum altitude
U and U is reduced for 1.2 % and I for 0.4 % for every additional 100 m
i e e
GENERALMAIN CIRCUIT
Number of contactors or switches side-by-side: <40 °C (40 … 55) °C Noise level (operation) Vibration resistance according to IEC/EN 60068-2-6 Shock resistance according to IEC/EN 6068-2-27 Maximum operating frequency with no load Mechanical endurance Weight Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1 coordination type 2
Maximum back-up fuse for short-circuit protection KS acc. to UL and CSA
Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-1, AC-7a and AC-21 Operational power for AC-1, AC-7a and AC-21: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-1, AC-7a and AC-21 Electrical endurance for AC-1, AC-7a and AC-21 Rated operational current for AC-2 Operational power for AC-2: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-2 Electrical endurance for AC-2 Rated operational current for AC-22 Operational power for AC-22: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-22 Electrical endurance for AC-22 Rated operational current for AC-3, AC-7b and AC-23 Operational power for AC-3, AC-7b and AC-23: single-phase 230 V three-phase 230 V three-phase 400 V Maximum operating frequency for AC-3, AC-7b and AC-23 Electrical endurance for AC-3, AC-7b and AC-23
1)
Surrounding air temperature for 4NO contacts version -13 °F…104 °F / -25 °C … 40 °C, for others contacts version 5 °F ... 104 °F / -15 °C ... +40 °C
2)
Surrounding air temperature for 4NO contacts version -13 °F…95 °F / -25 °C … 35 °C, for others contacts version 5 °F ... 95 °F / -15 °C ... +35 °C
3)
Rated voltage 480 V valid only for UL and CSA
Unit
IKA440 IKD440
UL 60947-4-1A, C22.2 No. 60947-4-1A-07, IEC/EN 61095, IEC/EN 60947-4-1
CE, UL, CSA
3 4
IP20 (IP40 when installed in installation box - distribution board)
1)
3
-22 °F ... 176 °F / -30 °C … +80 °C
a a
m
dB
g g
op. c./h
op. c.
g
no limit
max. 3 max. 3
30 20 2030
switched off: 2 (Z and X axis) / switched on: 3 (Z axis) and 1 (X axis)
switched off: 10 (Z and X axis) / switched on: 15 (Z axis) and 2 (X axis)
3.000.000 10.000.000 10.000.0003.000.000 350 420 350 420
2000
3.000
>17 V; >50 mA
0.118 in /3.6 mm
W
A
I
A
v
4 4
176
63 63 80 40 40
I
A
v
U
V
i
U
kV
imp
U
V
e
Hz
f
I
A
th
I
A
e
P
kW
e
op. c./h
op. c.
I
A
e
P
kW
e
60 60
440
4
400/480
50/60
40 63
8.7 16
600
100.000
25
3.7
11.2
op. c./h
op. c.
I
A
e
P
kW
e
40
7.4
12.7
120
50.000
22.2
op. c./h
op. c.
I
A
e
P
kW
e
22
3.7
5.5
300
50.000
11
op. c./h
op. c.
600
150.000
IKD463IKA463
2)
no limit
8 8
240
80 63 63 70 70
3)
6340
13.3 24 4026
32
4.8
8.36.5
14.4
63
11.6
20.1
34.9
30
5
8.5 15
30
4
Page 32
Installation Contactors UL/CSA
TECHNICAL DATA
Type
Rated motor power acc. to standards UL and CSA: single-phase 120 V single-phase 208 V single-phase 240 V three-phase 120 V three-phase 208 V three-phase 240 V three-phase 460 V Maximum operating frequency for motors acc. to UL and CSA Electrical endurance for motors according to UL and CSA General use according to standards UL and CSA: single-phase 240 V three-phase 480 V Maximum operating frequency for general use acc. to UL and CSA Electrical endurance for general use acc. to UL and CSA Switching of discharge lamps acc. to standards UL and CSA: single-phase 240 V - standard ballast three-phase 480 V - standard ballast Maximum operating frequency for discharge lamps acc. to UL and CSA Electrical endurance for discharge lamps acc. to UL and CSA Rated operational current for AC-5a (at 230 V) Maximum operating frequency for AC-5a Electrical endurance for AC-5a Rated operational current for AC-5b (at 230 V) Maximum operating frequency for AC-5b Electrical endurance for AC-5b Rated operational current for AC-6a (at 230 V) Maximum operating frequency for AC-6a Electrical endurance for AC-6a Switching of capacitors AC-6b and AC-7c (at 230 V) Maximum operating frequency for AC-6b and AC-7c Electrical endurance for AC-6b and AC-7c
MAIN CIRCUIT
Rated operational current for DC-1 (L/R < 1 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-1 Electrical endurance for DC-1 Rated operational current for DC-3 (L/R < 2 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-3 Electrical endurance for DC-3 Rated operational current for DC-5 (L/R < 7.5 ms): 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-5 Electrical endurance for DC-5 Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1
AUXILIARY CIRCUIT
coordination type 2
Symbol
P
e
I
e
I
e
I
e
I
e
I
e
C
I
e
I
e
I
e
S
I
v
Unit
HP
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
µF
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
W
A
up to 63 A
IKA440 IKD440
1 1
2
2
3 3
33 7 1/2 7 1/2
7 1/2 7 1/2
15 15
360
150.000
40 40
360
100.000
30 30
360
100.000
20
600
100.000
17.6 600
100.000
10.8 600
100.000
220 330
600
100.000
40/25/18/4/1.2 63/26/20/4/1.2
40/38/32/10/8
40/40/40/40/40 63/63/63/63/63
300
100.000
22/10/5/1.5/0.3 25/11/5/1.5/0.3
40/20/16/5/1
300
100.000
20/8/4/1/0.2
40/18/14/5/0.8
300
100.000
14 ... 10 AWG / 1.5 … 25 mm
14 ... 4 AWG / 1.5 … 16 mm
0.394 in / 10 mm M5
PZ2
30.98 lb-in / 3.5 Nm >17 V; >50 mA
0.118 in /3.6 mm
4
176
63
63
40 40
2 3 3 5
5 10 10 20
63
40
63/42/34/10/8
63/63/60/35/3040/40/40/30/20
45/22/18/5/1
63/45/35/18/540/40/32/15/4
63/63/63/63/1040/40/40/40/10
25/10/5/1/0.2
45/20/15/5/0.8
63/44/30/15/440/40/28/12/3
63/63/60/45/1040/40/40/35/8
2
2
80 63 63
IKD463IKA463
2
5
5 10 10 20
63
40
32
22
17.2
8
240
80
31
Page 33
Installation Contactors UL/CSA
up to 63 A
TECHNICAL DATA
Symbol
Type
Maximum back-up fuse for short-circuit protection K5 acc. to UL and CSA Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-15: single-phase 230 V single-phase 400 V Maximum operating frequency for AC-15 Electrical endurance for AC-15 Switching of auxiliary loads according to standard UL and CSA Maximum operating frequency for auxiliary loads according to UL and CSA Electrical endurance for auxiliary loads according to UL and CSA Rated operational current for DC-13: 1 pole … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 2 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC
AUXILIARY CIRCUIT
3 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC 4 poles in series … 24 V DC/48 V DC/60 V DC/110 V DC/ 220 V DC Maximum operating frequency for DC-13 Electrical endurance for DC-13 Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque Range of control voltage for switch-on Range of control voltage for drop out Kind of voltage Standard control voltages Frequency of AC control voltage Control mode Impulse duration of control voltage: minimum maximum Minimum duration between two impulses of control voltage Surge immunity withstand voltage 1,2/50 μs acc. to standard IEC/EN 61000-4-5 Coil consumption:
COIL AUXILIARY CIRCUIT
switch-on operation Delays: make brake Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque MTTF - Mean time to failure MTTF = 1/λ = B10/(0.1 n ) MTTF - Mean time to failure dangerous
d
MTTFd = 1/λ = B10 /(0.1 n )
d d op
op
B10 - Number of operating cycles until 10 % of devices fail
B10 - Number of operating cycles until 10 % of device dangerous
d
B10 = B10/ratio of dangerous failures
d
SAFETY
Ratio of dangerous failures n - Operating cycles (operating cycles/h)
op
1)
Coil consumption for -22 and -04 is 6.1 VA/6.1 W
Unit
I
A
v
U
V
i
U
kV
imp
U
V
e
Hz
f
I
A
th
I
A
e
IKA440 IKD440
60 60
op. c./h
op. c.
op. c./h
op. c.
I
A
e
op. c./h
op. c.
S
U
%
c
U
%
c
AC ACAC/DC AC/DC
U
V
c
Hz
f
ms
kV
VA/W
15.4/6
7.7/3 7.7/3
ms
10 … 20 10 … 15 35 … 45 35 … 4510 … 15
h
h
op. c.
op. c.
1/h
1/h
%
op. c./h
440
70 70
4
230/400
50/60
40 63
6 4
1.200
150.000
B300, P300
360
100.000
6/4/1/0.3/0.05
6/6/4/1/0.1
6/6/6/3/1 6/6/6/4/2
300
200.000
4 …10 AWG / 1.5… 25 mm 4 … 10 AWG / 1.5…16 mm
2
2
0.394 in / 10 mm M5
PZ2
30.98 lb-in / 3.5 Nm 85 ... 110
AC: 75 … 20 / DC: 75 … 10 (where is applicable)
12, 24, 48, 110, 120, 127, 208, 230, 240
50/60
remote control with U
c
permanent permanent
AC: 150 / DC: 500 (where is applicable)
2
1)
5/5
1)
5/5
15 … 20
16 ... 14 AWG / 1 … 2.5 mm 16 ... 14 AWG / 1 … 2.5 mm
15.4/6
10 … 20
2
2
0.315 in / 8 mm M3
PZ1
5.31 lb-in / 0.6 Nm General Use: 2.083
Motor: 3.125
General Use: 2.777
Motor: 4.166
General Use: 75.000
Motor: 112.500
General Use: 100.000
Motor:150.000
General Use: 0.00048
Motor: 0.00032
General Use: 0.00036
Motor: 0.00024
75
360
IKD463IKA463
5/5 5/5
15 … 20
1)
1)
32
4
Page 34
IKN , IKN-UL – Auxiliary switch
TECHNICAL DATA
Type
Standards Approvals Module width Number of poles Degree of protection Pollution degree Climatic conditions Ambient temperature:
GENERALAUXILIARY CIRCUIT
open closed Storage temperature Maximum altitude
U and U is reduced for 1.2 % and I for 0.4 % for every additional 100 m
i e e
Mechanical endurance Weight Contact reliability Minimum distance of open contacts Power dissipation per pole Maximum back-up fuse for short-circuit protection gL and gG: coordination type 2
Maximum back-up fuse for short-circuit protection KS acc. to UL and CSA
Rated insulation voltage Rated impulse withstand voltage Rated operational voltage
Rated frequency Thermal current Rated operational current for AC-15: single-phase 230 V single-phase 400 V Electrical endurance for AC-15 Switching of auxiliary loads acc. to standard UL and CSA Electrical endurance for auxiliary loads acc. UL and CSA Rated operational current for DC-13: 1 pole ... 24 VDC/ 48 VDC / 60 VDC / 110 VDC / 220 VDC 2 poles in series ... 24 VDC/ 48 VDC / 60 VDC / 110 VDC / 220 VDC Electrical endurance for DC-13 Switching of auxiliary loads acc. to standard UL and CSA Electrical endurance for auxiliary loads acc. UL and CSA Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque MTTF - Mean time to failure MTTF = 1/λ = B10/(0.1 n ) MTTF - Mean time to failure dangerous
d
MTTFd = 1/λ = B10 /(0.1 n )
d d op
op
B10 - Number of operating cycles until 10 % of devices fail
B10 - Number of operating cycles until 10 % of device dangerous
d
B10 = B10/ratio of dangerous failures
d
SAFETY
Symbol
U
Installation Contactors
Accessories
Unit
IKN
IEC/EN 60947-5-1
UL508, C22.2 No. 14, IEC/EN 60947-5-1
CE, CB, NF, EAC
0.5 0.5 2 2
1)
IP20
3
95 % relative humidity
-25 °C ... +55 °C
-13 °F ... 104 °F / -25 °C … +40 °C
-22 °F ... 176 °F / -30 °C … +80 °C
m
op. c.
-30 °C ... +80 °C
2000 2000
3.000.000 3.000.000 30 g
>12 V; >5 mA >12 V; >5 mA
3.6 mm
W
I
A
v
I
A
v
U
V
i
kV
imp
U
V
e
0.3
6
500 500
4 4
230/400
UL: C300 (120 VAC, 240 VAC)
UL: Q300 (125 VDC, 250 VDC)
Hz
f
I
A
th
I
A
e
op. c.
50/60 50/60
6
6
50.000
op. c.
I
A
e
6/4/1/0.3/0.05
6/6/4/1/0.1 6/6/4/1/0.1
op. c.
50.000
op. c.
S
1 … 2.5 mm 1 … 2.5 mm
2
2
16 ... 14 AWG / 1 … 2.5 mm 16 ... 14 AWG / 1 … 2.5 mm
7 mm
M3 M3
PZ1 PZ1
0.8 Nm
h
h
op. c.
op. c.
1/h
833 694
1.666 1.388
25.000
50.000
0.0012
IKN-UL
CE, UL, CSA
IP20
3
0.08 lb / 30 g
0.142 in /3.6 mm
0.3 (at I = 6 A)
th
6 6
IEC: 230 /400
IEC: 6 ; UL: 2.5
6 44
50.000
C300, Q300
50.000
6/4/1/0.3/0.05
50.000
C300, Q300
50.000
0.276 in / 7 mm
7.08 lb-in / 0.8 Nm
25.000
50.000
0.00144
1)
2
2
Ratio of dangerous failures n - Operating cycles (operating cycles/h)
op
1)
IP40 when installed in installation box - distribution boards
1/h
%
op. c./h
0.0006
0.00072
50 50
300 360
33
Page 35
Installation Switches IKS-R
Installation Momentary Switches IKS-T
TECHNICAL DATA
Type
Standards Approvals Module width Number of poles Degree of protection Pollution degree Climatic conditions Ambient temperature (open) Storage temperature Maximum altitude
GENERALMAIN CIRCUIT
U and U is reduced for 1.2 % and I for 0.4 % for every additional 100 m
i e e
Number of contactors or switches side-by-side: <40 °C (40 … 55) °C Maximum operating frequency with no load Mechanical endurance Weight Contact reliability Minimum distance of open contacts Power dissipation per pole Overload current withstand capability: 10 s Maximum back-up fuse for short-circuit protection gL and gG: coordination type 1 Rated insulation voltage Rated impulse withstand voltage Rated operational voltage Rated frequency Thermal current Rated operational current for AC-1, AC-7a and AC-21 Operational power for AC-1, AC-7a and AC-21: single-phase 230 V three-phase 230 V Maximum operating frequency for AC-1, AC-7a and AC-21 Electrical endurance for AC-1, AC-7a and AC-21 Rated operational current for AC-22 Operational power for AC-22: single-phase 230 V three-phase 230 V Maximum operating frequency for AC-1, AC-7a and AC-21 Electrical endurance for AC-1, AC-7a and AC-21 Rated operational current for AC-5a (at 230 V) Maximum operating frequency for AC-5a Electrical endurance for AC-5a (at 230 V) Rated operational current for AC-5b (at 230 V) Maximum operating frequency for AC-5b Electrical endurance for AC-5b (at 230 V) Rated operational current for AC-6a (at 230 V) Maximum operating frequency for AC-6a Electrical endurance for AC-6a (at 230 V) Switching of capacitors AC-6b and AC-7c (at 230 V) Maximum operating frequency for AC-6b and AC-7c Electrical endurance for AC-6b and AC-7c Terminal capacity: rigid (solid and stranded) flexible Length of removed wire insulation Screw Screw head Tightening torque
Symbol
I
v
U
i
U
imp
U
e
f
I
th
I
e
P
e
I
e
P
e
I
e
I
e
I
e
C
S
Unit
°C °C
m
op. c./h
op. c.
g
mm
W
A
V
kV
V
Hz
A A
kW
op. c./h
op. c.
A
kW
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
A
op. c./h
op. c.
µF
op. c./h
op. c.
2
mm
mm
Nm
IKS220-R IKS220-T
IKS225-R IKS225-T
IKS232-R IKS232-T
IKS420-R IKS42-T
IKS425-R IKS425-T
IEC/EN 60947-3
CE 2 2
IP20 (IP40 when installed in installation box - distribution board)
3
95 % relative humidity
-25 … +55
-30… +80
2000
no limitation
600
1.000.000
55
>17 V; >50 mA
3.6
1.7 1.7
2 2
2.5 2.5
72
20 20
25 25
32 32
440
4
230
50/60 20 20
4
25 25
5.4
32 32
7
20 20
4 7
300
100.000
20
3.7
25
4.6
32
5.9 5.9
20
3.7
6.2
300
50.000
8.8
11
13
8.8
300
100.000
8.8
9.7
11
8.8
300
100.000
4
4.8
6
4
300
100.000
30
36
40
30
300
100.000
1 … 10
1 … 6
9
M3.5
PZ1
1.2
105
68
25 25
5.4
25
4.6
11
9.7
4.8
36
IKS432-R IKS432-T
4 4
32 32
7
9
12
32
8
10.2
13
11
6
40
34
4
Page 36
Diagram 1
Installation Contactors
Electrical Endurance
AC-1/230V/1-phase for IKA20, IKD20, IKA220 (UL), IKD220 (UL), IKA225, IKD225, IKA232, IKD232, IKA440 (UL), IKD440 (UL), IKA463 AC-1/400V/3-phase for IK21, IKA25, IKD25, IKA425 (UL), IKD425 (UL), IKA432, IKD432, IKA40, IK40, IKA63, IK63
Millions of operating cycles
3
2
1
0,5
0,2 0,15
0,1
(UL), IKD463 (UL)
0,01
25
30
1
1,5
3
5
10
IK21 IKA20 IKD20 IKA220 (UL) IKD220 (UL)
20
IKA225 IKD225 IKA25 IKD25 IKA425 (UL) IKD425 (UL)
32
IKA232 IKD232 IKA432 IKD432
40
50 60
IKA40 IK40 IKA440 (UL) IKD440 (UL)
Breaking current [A]
70
63
IKA63 IK63 IKA463 (UL) IKD463 (UL)
35
Page 37
Installation Contactors
Electrical Endurance
Diagram 2
AC-3/400V/3-phase for IK21, IKA25, IKD25, IKA425 IKA432, IKD432, IKA40, IKA63, Ik63, IKA440 (UL), IKD425 (UL), (UL), IKD440 (UL), IKA463 (UL), IKD463 (UL)
Millions of operating cycles
3
2
1
0,3
0,15
0,1
1
Diagram 3
AC-3/230V/1-phase for IKA20, IKD20, IKA220 IKA225, IKD225, IKA232, IKD232 (UL), IKD220 (UL),
Millions of operating cycles
3
2
5
2,2
IK21
10
8,5
4
IKA25 IKD25 IKA425 (UL) IKD425 (UL) IKA432 IKD432
20
22
11
IKA40 IK40 IKA440 (UL) IKD440 (UL)
30
15
IKA63 IK63 IK463 (UL) IKD463 (UL)
Rated current [A]
40
Rated motor power [kW]
36
0,3
0,1
1
6
1
6
0,75
NC
contacts
1,3
NO
contacts
Rated current [A]
10
9
Rated motor power [kW]
4
Page 38
Mounting positions of accessories
Installation Contactors
Mounting Positions of Accessories
SEALING
COVER
IKV
IKN
IKA25
37
4
Page 39
Operating Position, Dimensions
Operation position
Installation Contactors
IKA20/225/232/ 25/432/ 40/ 63
IKA220/425/ 440/ 463 (UL)
180°
IKA20/225/232-R/-T IKA25/432-R/-T
180°
All installation contactors
15°
15°
IKA/D20/225/232-R/-T IKD20/225/232-R/-T IKA/D25/432-R/-T IKD25/432-R/-T
15°
15°
IKD20/225/232/ 25/432 IK40/63, IKD220/425/440/463 (UL)
15°
15°
15°
15°
NOTE: IK21 and IKS-R/-T have no limitation
Dimension (in milimeters)
IK21 IKA20, IKD20 IKA25, IKD25
IKA225, IKD225 IKA432, IKD432 IKA232, IKD232
50
35
4.75
4.1
85
45
17.5
85
45
57
39
17.7
4,5
62
43.5
35
38
4
60
44
35
5
Page 40
Dimensions (in milimeters unless otherwise stated)
IK40, IK63 IKA40, IKA63
84
45
Installation Contactors
Dimensions
60
35
53.5
IKA20-R, IKD20-R IKA225-R, IKD225-R IKA232-R, IKD232-R
17.5
IKA20-T, IKD20-T IKA225-T, IKD225-T
85
45
IKA232-T, IKD232-T
IKS220-R, IKS225-R IKS232-R
IKS220-T, IKS225-T IKS232-T
IKA220 (UL) IKA425 (UL) IKD220 (UL) IKD425 (UL)
5.5
43
IKA25-R, IKD25-R IKA432-R, IKD432-R IKS420-R, IKS425-R, IKS432-R IKS420-T, IKS425-T, IKS432-T
35
85
45
35
60
44
5
5
IKA440 (UL), IKD440 (UL) IKA463 (UL), IKD463 (UL)
17.5
(0.689 in)
35
(1.378 in)
35 (1.4 in)
60 (2.362 in)
44 (1.732 in)
5 (0.197 in)
85 (3.346 in)
45 (1.7717 in)
53.5 (2.1063 in)
35 (1.4 in)
4
60 (2.362 in)
43 (1.693 in)
5.5 (0.216 in)
84 (3.307 in)
45 (1.7717 in)
39
Page 41
Installation Contactors
Dimensions
Dimensions (in milimeters unless otherwise stated)
IKN IKN-UL
IKV
85
45
60
44
9
9
45
9 (0.3543 in)
60 (2.362 in)
44 (1.732 in)
85 (3.346 in)
45 (1.7717 in)
65.5
40
4
Loading...