Input
Input Voltage • 90-264 VAC
Input Frequency • 47 to 63 Hz
Input Current • 1.9A maximum
Output
Output Voltage: • See Tables
Output Current • See Tables
Output Power Range • 0 to 80 Watts
Ripple and Noise • 1% peak to peak max.
Overvoltage • Provided on output #1 only set at
Protection 112-132% of its nominal voltage
Overcurrent • All outputs protected to short
Protection: circuit conditions
Temperature • All outputs ±0.04%/°C
coefficient: maximum
Transient Response • Maximum excursion of 4% or better
on all models. Recovers to 1% of final
value within 500 µs after a 25% step
load change
General
Efficiency • 83% typical
Hold-up time • 12 msec minimum
Line Regulation • ±1% maximum at full load
Inrush Current • 15A max. at 115 VAC or
30A max. at 230 VAC cold start
Withstand Voltage • 3000 VAC from input to output
1500 VAC from input to ground
500 VAC from output to ground
Insulation Resistance • 100 Mohm minimum from
output to ground
Environmental
Operating • 0 °C to +70 °C, derate linearly from
Temperature 100% load at +40 °C to 50% load
at +70 °C
Storage • -40 °C to +85 °C
Temperature
MTBF • 100,000 hours minimum at full load
at 25 °C ambient
EMC & Safety
EMI Requirement • Meets conducted and radiated
limits of
a) FCC Part 15 Class B
b) CISPR 22 Class B
Safety Requirements • Approved to:
a) UL 1950
b) CSA C22.2 No. 234 per cUL
c) EN60950
80 Watts
HUP80 Series
AC/DC External Desktop
Specification
•
Intelligent Design Quality Product
XPiQ inc.
Meets EN61000-3-2
•
Built-in EMI Filter
•
100% Burn-in
•
Input Surge Current Protection
•
CE Mark
•
Approved to UL, CSA and TUV
Safety Standards
•
Wide Input Voltage 90-264 VAC
All specifications typical at nominal line, full load and 25°C
PH: 508 429.9883
FAX: 800 226.2100
Holliston, MA 01746 USA
www.XPiQ.com
71