Input
Input Voltage • 90-132 VAC, 180 to 264 VAC
(auto-ranging)
Input Frequency • 47-63 Hz
Input Current • 5.0 A max 115 VAC
2.5 A at 230 VAC
Leakage Current • 3.5 mA at 230 VAC
Output
Output Voltage • See Tables
Output Current • See Tables
Hold Up Time • 20 ms min at 125 VAC/80% load
Ripple & Noise • 1% pk-pk max
Overvoltage • Set at 110-135% of maximum
Protection output voltage (on output #1 only)
Overcurrent • All outputs protected to short
Protection: circuit conditions
Temperature • ±0.1%/°C maximum
Coefficient:
Transient Response • Maximum excursion of 5% recovering
to 1% of final value in less than
500 µs after a 50% step load
change
General
Line Regulation • ±1% maximum at full load
Inrush Current • 35 A at 115 VAC or 70 A at 230 VAC
at +25 °C cold start
Withstand Voltage • 3000 VAC from input to output
1500 VAC from input to ground
Switching Frequency • 42 kHz
Environmental
Operating • 0 °C to +70 °C
Temperature Derate linearly from 100% load at
Cooling 50 °C to 50% load at 70 °C
Storage • -20 °C to +85 °C
Temperature
Relative Humidity • 5% to 90% non condensing
MTBF • 100,000 hrs (MIL-HDBK-217D)
EMC & Safety
Safety Approvals • UL1950, CSA C22.2 No. 234
IEC 950 (EN60950)
EMI • In compliance with CISPR22
(EN55022), Class B and
FCC Class B
150 Watts
HUL150 Series
AC/DC U-Channel
Specification
•
Intelligent Design Quality Product
XPiQ inc.
Meets EN61000-3-2, -3
•
Meets 1U, Low Profile Requirements
•
Quad Outputs With 3.3V and 5V
•
100W with Convection Cooling
•
International Safety Approvals
•
CE Marked - LVD
PH: 508 429.9883
FAX: 800 226.2100
Holliston, MA 01746 USA
www.XPiQ.com