Datasheet H12WD4890 Specification

Page 1
H1 SERIES | H12WD
PANEL MOUNT
PRODUCT SELECTION
Features
• Ratings from 25A to 125A @ 48-660 VAC
Low off-state leakage current (snubberless)
• SCR output for heavy industrial loads
• Zero Voltage or instantaneous turn-on outputs
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• DC control
• Direct bond copper substrate
EMC Compliant to Level 3
• Direct power lead frame
• Epoxy free design
For Generation 3 datasheet click here
Control Voltage
4-32 VDC
ORDERING OPTIONS
H1 2WD 48 25 K P G H -10
Serires
H1
Transient Overvoltage
2WD: 1200 Vpk
Operating Voltage
48: 48-660 VAC
Rated Load Current
25: 25 Amps 90: 90 Amps 50: 50 Amps 125: 125 Amps 75: 75 Amps
Termination
Blank: Screw F: Quick Connect (Up to 50 Amps only) (1) K: Hex standoffs (2)
Overvoltage Protection
Blank: Not Included P: Included (3)
Input Status LED
Blank: Not Included G: Included
Thermal Pad
Blank: Not Included H: Included
Switching Type
Blank: Zero Voltage Turn-On
-10: Instantaneous Turn-On (4)
25A
H12WD4825
50A
H12WD4850
75A
H12WD4875
Required for valid part number For options only and not
required for valid part number
90A
H12WD4890
Note: Not all part number combinations are available. Contact Crydom Technical support for information on the availability of a specific part number.
125A
H12WD48125
Page 1
Copyright © 2018 Sensata Technologies, Inc.
www.sensata.com
Page 2
OUTPUT SPECIFICATIONS
(5)
Operating Voltage (47-440Hz) [Vrms] 48-660 48-660 48-660 48-660 48-660 Transient Overvoltage [Vpk] 1200 1200 1200 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 1.0 1.0 1.0 1.0 1.0 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 500 500 500 500 Maximum Load Current [Arms] (6)(3) 25 50 75 90 125 Minimum Load Current [mArms] 150 150 150 150 150 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 239/250 597/625 954/1000 1145/1200 1670/1750 Maximum On-State Voltage Drop @ Rated Current [Vrms] 1.15 1.15 1.15 1.15 1.15 Thermal Resistance Junction to Case (Rjc) [°C/W] 0.8 0.45 0.3 0.27 0.22 Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 285/259 1779/1621 4555/4150 6560/5976 13950/12709 Minimum Power Factor (at Maximum Load) (7) 0.5 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS
(5)
Description DC Control
125A90A75A50A25ADescription
Control Voltage Range 4-32 VDC Minimum Turn-On Voltage (7) 4.0 VDC Must Turn-Off Voltage 1 .0 VDC Maximum Reverse voltage -32 VDC Minimum Input Current 7 mADC Maximum Input Current 12 mADC Nominal Input Impedance Current Regulated Maximum Turn-On Time [msec] (8) 1/2 Cycle Maximum Turn-Off Time [msec] 1/2 Cycle
GENERAL SPECIFICATIONS
(5)
Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.6 oz (74.9 g) Housing Material 94 V-0 Baseplate Material Aluminum Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7 Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2.0-2.2 SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2.0-2.2 Input/Load Terminal Screw Torque Range (in-lb/Nm)
(3) w/”K” option 8-10 / 0.9-1.13
Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC Humidity per IEC60068-2-78 93% non-condensing LED Input Status Indicator w/”G” option (green)
MTBF (Mean Time Between Failures) at 40°C ambient temperature (9)
11,641,553 hours (1,328 years)
MTBF (Mean Time Between Failures) at 60°C ambient temperature (9)
9
10
Ohm
7,210,376 hours (823 years)
WIRING DIAGRAM
AC
V
Load (10)
1 ( ) 2 ( )
2
OUTPUT
1
SOLI D ST AT E R ELA Y
4
INPUT
3
4 (–) 3 (+)
Copyright © 2018 Sensata Technologies, Inc.
Terminals
Input
Output
Recommended Wire Sizes
Wire Size
(Solid / Stranded)
24 AWG (0.2 mm
2 x 12 AWG (3.3 mm
20 AWG (0.5 mm
2 x 10 AWG (5.3 mm
2 x 8 AWG (8.4 mm
2
) / 0.2 [minimum]
2
2
) / 0.518 [minimum]
2
2
) / 8.4 [maximum]
) / 3.3 [maximum]
) / 5.3
www.sensata.com
Wire Pull-Out
Strength (lb)[N]
10 [44.5]
90 [400]
30 [133]
110 [490]
90 [400]
Input Current vs Input Voltage
Standard Regulated DC Input
25
20
15
10
Input Current (mA)
5
0
0 5 10 15 20 25 30
DC Input Voltage
Page 2
Page 3
EQUIVALENT CIRCUIT BLOCK DIAGRAM
4
-
DC
3
+DC
MECHANICAL SPECIFICATIONS
Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters]
Screw Termination
1.1
1.88
[47.6]
[27.9]
0.49
[12.4]
OUTPUT
1
S OLID ST AT E RELA Y
4
INPUT
1.0
[25.4]
1.75
[44.5]
Mounting Hole/Slot
0.19 [4.9] DIA.
2
1.7
[43.2]
3
Current
Limiter
(11)
(5)
0.89
[22.6]
2.25
[57.3]
Trigger Circuit
1.88
[47.6]
1
AC
(12)
2
AC
Hex Standoff Termination (“K” Option)
1.1
[27.9]
0.49
[12.4]
OUTPUT
1
S OLID ST AT E RELA Y
4
INPUT
1.0
[25.4]
1.75
[44.5]
Mounting Hole/Slot
0.19 [4.9] DIA.
2
[43.2]
3
1.70
(3)
1.04
[26.4]
0.93
[23.6]
(4 places)
1.0
[25.4]
(2 places)
2.25
[57.3]
Quick Connect Termination (“F” Option) - Up to 25 Amp (2)
Mounting Hole/Slot
0.19 [4.9] DIA.
1.88
[47.6]
1.58
[40.2]
0.49
[12.4]
OUTPUT
1
S OLID ST AT E RELA Y
4
INPUT
1.40
[35.6]
1.75
[44.5]
Faston Terminal(13)
0.25 x 0.032
(2 places)
2
3
Faston Terminal(13)
1.7
[43.2]
0.187 x 0.020
(2 places)
1.31
[33.4]
1.25
[31.8]
2.25
[57.3]
Quick Connect Termination (“F” Option) - Up to 50 Amp (2)
Faston Terminal(13)
[11.4]
(2 places)
2
3
Faston Terminal(13)
0.25 x 0.032
(4 places)
0.45
1.7
[43.2]
0.187 x 0.020
(2 places)
Mounting Hole/Slot
0.19 [4.9] DIA.
1.88
[47.6]
1.58
[40.2]
0.63
[16.0]
OUTPUT
1
S OLID ST AT E RELA Y
4
INPUT
0.49
[12.4]
1.40
[35.6]
1.75
[44.5]
1.31
[33.4]
2.25
[57.3]
1.25
[31.8]
Copyright © 2018 Sensata Technologies, Inc.
Page 3
www.sensata.com
Page 4
SURGE CURRENT INFORMATION
250
200
150
100
50
Surge Current (Amp)
0
0.01 0.1 1 10
900 800 700 600 500 400 300 200
Surge Current (Amp)
100
0
0.01 0.1 1 10
Non repetitive peak surge current at Tj initial 40ºC.
25 A
Surge Duration (Secs)
75 A
Surge Duration (Secs)
1800 1600 1400 1200 1000
800 600 400
Surge Current (Amp)
200
0
0.01 0.1 1 10
600
500
400
300
200
100
Surge Current (Amp)
125 A
Surge Duration (Secs)
50 A
0
0.01 0.1 1 10
Surge Duration (Secs)
90 A
1200
1050
900
750
600
450
300
Surge Current (Amp)
150
0
0.01 0.1 1 10
Surge Duration (Secs)
THERMAL DERATE INFORMATION
25 A
1.5ºC/W
25
20
15
10
5
Load Current (Amps)
0
20 30 40 50 60 70 80
2ºC/W
Ambient Temperature (ºC)
Load Current (Amps)
3ºC/W
90 A
0.5ºC/W
90 80 70 60 50 40 30 20 10
0
20 30 40 50 60 70 80
0.7ºC/W
Ambient Temperature (ºC)
50 A
0.7ºC/W
50
40
30
20
10
Load Current (Amps)
0
20 30 40 50 60 70 80
1ºC/W
1ºC/W
1.5ºC/W
Ambient Temperature (ºC)
1.5ºC/W
2ºC/W
0.5ºC/W
75
60
45
30
15
Load Current (Amps)
0
20 30 40 50 60 70 80
125 A
0.5ºC/W
120
100
80
60
40
20
Load Current (Amps)
0
20 30 40 50 60 70 80
0.7ºC/W
Ambient Temperature (ºC)
75 A
0.7ºC/W
Ambient Temperature (ºC)
1ºC/W
1ºC/W
1.5ºC/W
Copyright © 2018 Sensata Technologies, Inc.
Page 4
www.sensata.com
Page 5
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 600068-2-6: Vibration 0.33mm and 0.75mm Amplitude over 10-55 Hz IEC 600068-2-27: Shock Resistance 15g/11ms
E116949 (25, 50, 75 and 90A) E116950 (125A) LR81689 10143 UG
ACCESORIES
Protective Cover & Hardware Kits
Recommended Accessories
Protective Cover
Part number: KS101
Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment.
Hardware Kit
Part number: HK4
Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals.
Cover Hardware
Kit
KS101 HK1
HK4
Heat Sink
Part No.
HS501DR
HS301 / HS301DR
HS251
HS202 / HS202DR
HS201 / HS201DR
HS172
HS151 / HS151DR
HS122 / HS122DR
HS103 / HS103DR
HS101
HS073
HS072
HS053
HS033
HS023
Thermal Resistance
[ºC/W]
5.0
3.0
2.5
2.0
2.0
1.7
1.5
1.2
1.0
1.0
0.7
0.7
0.5
0.36
0.25
Lug Terminal Thermal Pad
TRM1
TRM6
HSP-1
HSP-2
GENERAL NOTES
(1)
Single pair (up to 25A) Double pair* (50A model only). *Caution: User must connect to both pairs
(2) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50 Amps.
For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support.
(3)
O
utput will self trigger between 900-1200Vpk, Min. power factor 0.7 or higher, not suitable for capacitive loads.
(4) Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only. (5)
All parameters at 25°C unless otherwise specified.
(6) Heat sinking required, see derating curves. (7) Increase minimum voltage by 1V for operations from -20 to -40°C. (8) Turn-on time for Instantaneous turn-on versions is 0.02 msec.
(9)
All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(10)
Load can be wired to either SSR output terminal 1 or 2.
(11) Elective Input Status LED, “G” option. (12) Elective Overvoltage Protection, “P” option. (13)
Mechanical dimensions vary from G3 models.
For additional information or specific questions, contact Crydom Technical Support.
Copyright © 2018 Sensata Technologies, Inc.
Page 5
www.sensata.com
Page 6
WARNINGS
www.sensata.comCopyright © 2018 Sensata Technologies, Inc.
RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
• The product’s side panels may be hot, allow the product to cool before touching
• Follow proper mounting instructions including torque values
• Do not allow liquids or foreign objects to enter this product
Failure to follow these instructions can result in serious injury, or equipment damage.
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
• Disconnect all power before installing or working with this
equipment
• Verify all connections and replace all covers before turning on
power
Failure to follow these instructions will result in death or serious injury
Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA.
Rev. 021218 ECN 20395 FDE-07-01 Rev. B
Page 6
CONTACT US
Americas
+1 (877) 502 5500 – Option 2 sales.crydom@sensata.com
Europe, Middle East & Africa
+44 (1202) 416170 ssr-info.eu@sensata.com
Asia Pacific
sales.isasia@list.sensata.com
China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006
ext 2808