Features
1. Less sensitive to a fluorescent lamp driven by inverter
2. Various B.P.F. (Band Pass Filter) frequency
3. Built-in voltage regulator circuit
Applications
1. TVs
2. VCRs
3. Audio equipment
4. Air conditioners
5. CATV set top boxes
6. BS receivers
7. Multi-media equipments
Absolute Maximum Ratings
Parameter Symbol Rating Unit
Supply voltage
*1
Operating temperature
Storage temperature T
*2
Soldering temperature
*1 No dew formation *2 For 5 seconds
V
CC
T
opr
stg
T
sol
(
0 to 6.3 V
- 10 to + 70
- 20 to + 70 260 ˚C
Outline Dimensions
13.25
3.6
2
+
0.5
15.4
-
0.3
2.542.542.1
2 2 2
2
5.5
± 0.5
* Tolerance0.3mm
1 Detector center2 The dimension of connector base
(
Unit : mm
15
1
7.5
3.65
1
1 Vout 2 Vcc 3 GND
2.4
Recommended drilling as viewed from the soldering face.
12 3
14.2 1.4
3-
φ
0.8
12 3
2.54
)
Rib
4.3
1.72.54
)
˚C ˚C
Recommended Operating Conditions
Parameter Symbol Value Unit
Supply voltage V
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
4.7 to 5.3 V
CC
Page 2
GP1U58Y Series
Electrical Characteristics
Parameter Symbol MIN. TYP. MAX. Unit Dissipation current I High level output voltage V Low level output voltage V High level pulse width T Low level pulse width T B.P.F. center frequency f
*3 The burst wave as shown in the following figure shall be transmitted by the transmitter shown in Fig. 1. *4 Diversified models with a different B.P.F frequency, as shown in a separate table, are also available.
600µ s600 µ s
The value of fO is shown in a separate table. Duty 50%
CC
OH
OL
1
2
O
Conditions
No input light
*3
-
Model Line-up
Model No. B.P.F. frequency Unit
GP1U58Y GP1U580Y GP1U581Y GP1U582Y GP1U583Y GP1U587Y
40 36 38
36.7
32.75
56.8
kHz
(
Ta= 25˚C, V
CC
- - 5.0 mA
VCC- 0.5
--V
- - 0.45 V 400 - 800 400 - 800
*4
- - kHz
40
= +5V
µ
s
)
Internal Block Diagram
Amp
Vout
B.P.F.Limiter
ComparatorIntegratorDemodulator
Vcc GND
Page 3
Performance
Using the transmitter shown in Fig. 1, the output signal of the light detecting unit is good enough to meet the following items in the standard optical system in Fig. 2. (1)
Linear reception distance characteristics
When L= 0.2 to 8m, Ee<10 lx and φ = 0˚ in Fig. 2, the output signal shall meet the electrical characteristcs in the attached list.
(2)
Sensitivity angle reception distance characteristics
When L= 0.2 to 6m, Ee<10 lx and φ <=30˚ in Fig. 2, the output signal shall meet the electrical characteristics in the attached list.
(3)
Anti outer peripheral light reception distance characteristics
When L=0.2 to 4m, Ee<=300 lx and φ = 0˚ in Fig. 2, the output signal shall meet the electrical characteristics in the attached list.
GP1U58Y Series
20cm
Transmitter (GL521 used Duty 50 % Center frequency (fo depends on the attached model list.
)
)
PD49PI
10k
10k
+ 5V
10µF
Vout
Oscilloscope
Fig. 1. Transmitter
In the above figure, the transmitter should be set so that the output V out can be 40mV However, the PD49PI to be used here should be of the short-circuit current I
= 2.6µ A at EV=
SC
100 lx. (
E
is an illuminance by CIE standard light source A (tungsten lamp).
V
Reception distance : L
)
Light detector face illuminance : Ee
φ φ
Vout
.
PP
Transmitter
(
φ indicates horizontal and
vertical directions.
)
Fig. 2. Standard optical system
Page 4
Precautions for Use
(1)
Use the light emitting unit (remote control transmitter), in consideration of performance,
characteristics and operating condition of light emitting device and the characteristics of the light detecting unit.
(2)
Pay attention to a malfunction of the light detecting unit when the surface is stained with
dust and refuse. Care must be taken not to touch the light detector surface. If it should be dirty, wipe off with soft cloth so as to prevent scratch. In case some solvents are required, use metyl alcohol, ethyl alcohol or isoprophyl alcohol. Also, protect the light detecting unit against flux and others.
(3)
The shield case shall be grounded on PWB pattern.
(4)
Do not apply unnecessary force to the terminals and case form outside.
(5)
Do not push the light detector surface (photodiode) from outside.
(6)
To avoid the electorstatic breakdown of IC, handle the unit under the condition of ground-
ing with human body, soldering iron, etc.
(7)
In case of adopting the infrared light detecting unit for the wireless remote control, use it
in accordance with the transmission scheme and the signal format recommended in“Coun­termeasures for malfunction prevention of home appliances with infrared remote control” issued form Japan Association of Electrical Home Appliances (AEHA) in July 1987.
(8)
As for other general cautions, refer to the chapter “ Precautions for Use”(Page 78 to 93).