Ultra-miniature, Highly Sensitive SPDT
Relay for Signal Circuits
■ Ultra-miniature at 12.5 x 7.5 x 10 mm (L x W x H).
■ Wide switching power of 1 mA to 1 A.
■ High sensitivity: 150-mW nominal coil power.
■ Fully sealed construction.
■ International 2.54-mm terminal pitch.
■ Conforms to FCC Part 68 requirements for coil to
contacts.
G5V-1 PCB Relay
RoHS Compliant
Refer to pages 16 to 17 for details.
Ordering Information
Classification Model
Contact form Contact type Contact material Structure
SPDT Single crossbar Ag + Au-Alloy Fully sealed G5V-1
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-1 12 VDC
Rated coil voltage
Model Number Legend
G5V - VDC
12
1. Contact Form
1: SPDT
2. Rated Coil Voltage
3, 5, 6, 9, 12, 24 VDC
Specifications
■ Coil Ratings
RC
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC
Rated current 50 mA 30 mA 25 mA 16.7 mA 12.5 mA 6.25 mA
Coil resistance 60
Coil inductance
(H) (ref. value)
Must operate voltage 80% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 200% of rated voltage at 23°C
Power consumption Approx. 150 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
Armature OFF 0.05 0.15 0.20 0.45 0.85 3.48
Armature ON 0.11 0.29 0.41 0.93 1.63 6.61
Ω 167 Ω 240 Ω 540 Ω 960 Ω 3,840 Ω
46

■ Contact Ratings
Load Resistive load (cosφ = 1)
Rated load 0.5 A at 125 VAC; 1 A at 24 VDC
Contact material Ag + Au-Alloy
Rated carry current 2 A
Max. switching voltage 125 VAC, 60 VDC
Max. switching current 1 A
Max. switching power 62.5 VA, 30 W
Failure rate (reference value)
(See note.)
Note: P level: λ60 = 0.1 x 10–6/operation
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 100
may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions.
■
Characteristics
1 mA at 5 VDC
G5V-1G5V-1
Ω. This value
Contact resistance (See note 1.) 100 m
Operate time (See note 2.) 5 ms max. (approx. 2.5 ms)
Release time (See note 2.) 5 ms max. (approx. 0.9 ms)
Max. operating frequency Mechanical: 36,000 operations/hr
Insulation resistance (See note 2.) 1,000 M
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between coil and contacts
Impulse withstand voltage 1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)
Vibration resistance Destruction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Shock resistance
Endurance Mechanical: 5,000,000 operations min. (at 18,000 operations/hr)
Ambient temperature Operating:
Ambient humidity Operating: 5% to 85%
Weight Approx. 2 g
Note: The values here are initial values.
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2. Values in parantheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter between coil and contacts and a 250-VDC megohm-
meter between contacts with the same polarity applied to the same parts as those used for checking the dielectric strength.
Approved Standards
■
Ω max.
Electrical: 1,800 operations/hr (under rated load)
Ω min. (at 500 VDC between coil and contacts, at 250 VDC between contacts of same
polarity.)
400 VAC, 50/60 Hz for 1 min between contacts of same polarity
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 100 m/s
Electrical: 100,000 operations min. (under rated load, at 1,800 operations/hr)
−40°C to 70°C (with no icing)
2
2
UL1950 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR31928)
Model Contact form Coil ratings Contact ratings
G5V-1 SPDT 3 to 24 VDC 0.5 A, 125 VAC (general use)
0.3 A, 110 VDC (resistive load)
1 A, 30 VDC (resistive load)
47

Engineering Data
G5V-1G5V-1
Maximum Switching Power Ambient Temperature vs.
Endurance
Maximum Coil Voltage
5,000
3,000
1,000
700
500
300
100
3
70
50
24-VDC resistive load
Rated coil voltage
Switching current (A)
Maximum coil voltage (%)
DC resistive load
AC
resistive
load
Endurance (x10 operations)
125-VAC
resistive
load
Switching voltage (V) Ambient temperature (°C)Switching current (A)
Note: The maximum coil voltage refers to the maxi-
mum value in a varying range of operating
power voltage, not a continuous voltage.
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Numbers in parentheses are reference values.
3. Tolerance: ±0.1
4. Orientation marks are indicated as follows:
12.5 max.
(12.3)*
10 max.
(9.9)
0.5
3.5
0.5
Terminal Arrangement/
7.5 max.
(7.3)*
0.30.3
0.5
Internal Connections
(Bottom View)
1
10
* Average value
2
5
69
Six, 1-dia. holes
Mounting Holes
(Bottom View)
(1.07)
2.54 7.62
10.16+0.1
(1.11)
5.08+0.1
(1.11)
(1.07)
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously for long periods (without switching) can lead to unstable
contacts, because the heat generated by the coil itself will affect
the insulation, causing a film to develop on the contact surfaces.
Be sure to use a fail-safe circuit design that provides protection
against contact failure or coil burnout.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K048-E1-02
48
Relay Handling
When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep the
solvent temperature to less than 40
°C. Do not put the Relay in a
cold cleaning bath immediately after soldering.