Datasheet E4 Datasheet (OMRON)

Page 1
E4 Tens Massager
Low-Frequency Electronic Pulse Massager
E4 Tens
Instruction manual page 01
Page 2
E4 English
Table of contents Page
1 Safety precautions 2 2Overview 2
2.1 Control functions 3
3 How to obtain a correct treatment 4
3.1 Program 4
3.2 Settings 5
4Preparation 5
4.1 Insert batteries 5
4.2 To use the massager for the first time 6
4.3 Attach Long Life pads 7
5Operation 8
5.1 Treatment program 8
5.2 Setting 8
6 End of treatment and care 9 7Storage 10 8Troubleshooting and maintenance 11
8.1 Maintenance and spare parts 11
8.2 Replace batteries 11
9Technical data 12
Introduction
1
Page 3
1. Safety precautions
A
E C
F
H
B
D
G
E4 English
General
• Do not let children or infirm people have access to the massager.
• Do not apply Long Life pad during treatment on other person.
Do not use the massager under the following circumstances:
• Persons with medical implants, e.g. heart pacemakers.
•Simultaneously with other medical devices, e.g. respirators and electrocardiographs.
• Any condition where your doctor deems low frequency electrotherapy inappropriate.
•While driving.
•While sleeping.
Consult your doctor:
• During an acute, contagious or infectious disease.
•When suffering from a malignant tumour.
• During pregnancy or during menstruation.
•When suffering from cardiac dysfunction or abnormal blood pressure.
2. Overview
•Varicose veins.
•When having high fever.
• During medical treatment, especially those that are leading to discomfort.
Tips for use
• Do not apply ointment to the skin.
• Do not apply the Long Life pads near the heart, above the neck, on the head, around the mouth.
•Do not apply the Long Life pads on skin with disorders.
•Treat one part of the body for maximum 30 minutes.
Caution
• Do not drop the massager.
• Put the Long Life pads only on skin or on the Long Life pads holder to avoid damage of the adhesive surfaces of the pads.
• Do not use the massager in a sauna or while taking a bath or shower.
• Keep cellular phones 5 meters out of range during treatment.
A Main unit B Electrode cord with safety plug C Red connector D White connector
2
E Long Life pads F Long Life pads holder G Battery compartment H Soft fabric storage case
Page 4
2.1 Control functions
E4 English
J
J1
J2
K
Q
W2
W1
W4
J3
J4
M
L
N
P
S
R
T
U V
W
W3
J Display:
J1 Minutes to go during treatment, J2 Blinking bar shows frequency, J3 Indication Point, J4 Indication Wide.
K Low frequency button: to select treatment for
stiff muscles.
L High frequency button: to select treatment for
acute pain.
M On/Off and Adjustment Dial Switch: to turn
on/off the power and to adjust the intensity.
N Display shows on/off, intensity 0 to 10. P Part of the body button: to select region. Q Indication Part of the body button (shoulder,
joint, arm, sole, leg, back).
R Massage button: to select favourite massage
method.
S Indication massage method (tap, knead, push
and rub).
T Hyper button: to select gradual increase of
intensity.
U Soft button: to select soft stimulation. V Repeat button: to repeat favourite stimulation. WPoint/Wide:
W1 Left (red) Long Life pad, W2 Pulse is applied on one point, W3 Right (white) Long Life pad, W4 Pulse is applied on a wider surface.
3
Page 5
E4 English
3. How to obtain a correctt treatment
3.1 Program
To obtain a correct treatment you have available twelve treatment programs (see table below). A treatment program runs during 15 minutes.
Complaint Program Effect
1 Stiff muscles, Different combinations of vibrations on a low
numbness frequency to promote blood circulation. This program
is effective over a long period
2 Acute pain High frequency vibrations relieve acute pain promptly
3 Stiff shoulders Different vibrations promote blood circulation
and relieve fatigue
4 Acute elbow High frequency vibrations relieve pain promptly
or knee pain
5 Arm fatigue Different vibrations promote blood circulation
6 Swelling and Different vibrations promote circulation of blood
foot fatigue and body fluid in the feet
7 Swelling and Different vibrations promote circulation of blood
calf fatigue and body fluid in the limbs
8 Back pain or Low frequency vibrations promote circulation of
lower back blood and relieve pain (neuralgia) stiffness
9
10
Various symptoms Your favourite massage method (tap, knead, push
11 or rub) relieves stiffness, pain and fatigue
12
4
Page 6
E4 English
1
10
1
4. Preparation3.2 Settings
Several settings can be made to get your favourite treatment. You can compose your favourite treat­ment at the beginning of the treatment program and you can change it any time.
Hyper mode and Soft mode
You can select either Hyper mode or Soft mode. Hyper mode increases gradual stimulation during treatment and relieves stiffness effectively. Soft mode stimulates without giving the feeling of irritation and relieves stiffness comfortably.
Treatment surface
The treatment can be applied on a specific point or to a wider surface of the Long Life pads.
Intensity
4.1 Insert batteries
OFF
"Click"
1 Turn the On/Off-switch OFF.
2 Remove the battery cover.
The intensity level of the massage is adjustable with a dial switch.
Repeat
You can repeat your favourite stimulation. If the repeat button is activated the device will repeat the last part of the selected treatment program. The device will continue with the treatment program if the repeat button is deactivated.
3 Insert two batteries in the battery compartment.
Caution! Use two identical batteries!
5
Page 7
E4 English
4 Put the battery cover on the battery
compartment.
4.2 To use the massager for the first time
OFF
"Click"
Caution! Make sure the device is turned off and that the batteries are inserted correctly!
2 Take the Long Life pads out of the sealed package.
3 Connect the electrode cord to the Long Life pads.
4 Remove the film from the Long Life pads and
attach the pads directly onto your skin. Caution! Do not damage the adhesive surfaces of the Long Life pads!
1 Pinch the safety plug and connect it to the main
unit.
6
Page 8
4.3 Attach Long Life pads
Caution! Always use clean Long Life pads! Caution! Do not fold the Long Life pads! Caution! Avoid the Long Life pads touching any
metal object, such as belt buckle or necklace!
• Attach the Long Life pads on both shoulders with the backbone in the centre.
E4 English
•Attach both Long Life pads on the upper arm where you feel pain.
•Attach one Long Life pad to the sole of the foot that feels cold and the other one on the calf. Caution! Do not simultaneously attach the Long Life pads on the soles of both feet!
• Attach the Long Life pads on both sides of the joint where you feel pain.
• Attach both Long Life pads on the calf where you feel pain.
• Attach both Long Life pads on the lower back with the backbone in the centre.
7
Page 9
E4 English
1
10
1
1
10
1
1
10
1
1
10
1
1
10
1
5. Operation
Caution! Make sure that the components are
connected well and the Long Life pads are fixed on the part of the body you wish to treat! Caution! Do not pull on the electrode cord during treatment!
Note: Turn Adjustment Dial-switch for intensity (1-10) if required.
5.1 Treatment program 1 Turn On/0ff-switch to level 1.
ON
1
"Click"
5.2 Setting
1 Select Hyper mode or Soft mode.
For selecting Hyper mode press 3 seconds Hyper button.
2 Select point pulse or wide pulse.
2 Select one of the twelve programs according to
1
your complaint.
8
3 Press repeat button to have previous treatment
program start over.
Treatment program runs for 15 minutes.
Page 10
6. End of treatment and care
After 15 minutes the massager stops automatically.
E4 English
OFF
"Click"
1 Stop program if required. Caution! Stop treatment when you want to
change the treatment program! Caution! Stop treatment when you want to move a Long Life pad! Caution! Stop treatment when you feel discomfort with your body or skin! Caution! Stop treatment when the massager is not functioning properly or you feel discomfort!
3 Pinch the safety plug and remove it from the
main unit.
4 Disconnect the electrode cord from the Long
Life pads.
5 Wash the pads softly with your fingertips under
slow running water for about 3 seconds.
Caution! Do not use hot water!
2 Remove the Long Life pads and place the pads
on the Long Life pads holder.
9
Page 11
6 Sufficiently dry the Long Life pads.
-20
+60
Caution! Do not wipe the adhesive surfaces! Caution! Let the adhesive surfaces of the
Long Life pads air-dry! Caution! Adhesive surface sides up during drying!
E4 English
9 Use a soft, slightly moistened cloth to clean the
main unit. Caution! Do not wash and do not use petrol, thinners or similar solvents!
7. Storage
7 Connect the electrode cord on the Long Life
pads and place the pads on the pad holder.
8 Wrap the electrode cord around the pad holder.
10
• Put the massager and the pad holder in the soft storage case.
•Store the massager on a dry, closed place with a temperature between -20º and 60ºC. Caution! Remove the batteries for a long time storage (more than three months)!
Page 12
E4 English
8. Troubleshooting & Maintenance
Problem Cause Rectification
Device will not Batteries inserted in wrong Insert batteries in correct direction turn on direction Power turns off Long Life pads not attached Attach Long Life pads correctly to the skin too soon correctly to the skin Power turns off Batteries weak/exhausted Fit two new identical 1.5V alkaline while using massager batteries type AAALR03
Treatment period of 15 Restart treatment or turn off minutes is over and power the massager turns off automatically
Electrode cord broken Replace electrode cord It is difficult to attach Transparent film not peeled off Peel off film on the adhesive Long Life pad to surface of Long Life pad the skin Long Life pad applied Sufficiently dry Long Life pad
immediately after washing
Adhesive surface of Long Replace Long Life pad
Life pad damaged Adhesive surface Use of Long Life pad of Long Life pad during perspiring is sticky Long Life pad washed too Leave Long Life pad in
long and/or too frequently freezer for overnight
Long Life pads stored under
high temperature, high
humidity, direct sunshine It is difficult to Long Life pads not attached Attach Long Life pad firmly feel stimulation correctly to the skin to the skin
Long Life pads overlap each Reattach Long Life pads with no overlap
other
Electrode cord not Connect electrode cord correctly
connected correctly
Applied intensity too weak Increase the intensity by turning the dial switch The skin turns Adhesive surface of Long Wash adhesive surface of Long Life pads red or the skin Life pads dirty or dry softly with your fingertips for about 3 seconds feels irritated under slow running water
Adhesive surface of Long Replace Long Life pads
Life pads damaged
8.1 Maintenance and spare parts
• Do not carry out repairs of any kind yourself. If a defect occurs consult the customer service or authorised dealer of Omron.
8.2 Replace batteries
• Remove the batteries from the battery compartment and insert two new identical batteries.
Attention! Disposal of batteries and the Omron E4 Tens massager should be carried out in accordance with the national regulations for the disposal of electronic products.
11
Page 13
E4 English
9. Technical Data
Product Name OMRON E4 TENS massager Model HV-F128-E Power supply 3 VDC (2 1.5V alkaline batteries type AAALR03) Battery life Approx. 3 months: when used 15 minutes a day continuously
Frequency generation Approx. 1 to 1200 Hz Power consumption Approx. 85 mA Operating temperature and humidity 10°C to 40°C, 30 to 85% RH Storage temperature and humidity -20°C to 60°C, 10 to 95% RH Main unit dimensions 60 (W) x 199 (H) x 21 (D) mm Weight Approx. 155 g (including batteries) Accessories Electrode cord
Specifications may be changed without prior notice.
Type BF = 0197
Read the instructions in this manual carefully.
Approx. 2 months: when used 15 minutes a day continuously under Hyper mode
Set of Long Life pads Batteries for monitor (2 identical 1.5V alkaline batteries type AAALR03) Long Life pad holder Soft fabric case Instruction manual
This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive).
Manufacturer Omron Matsusaka Co. LTD., Japan. EU-representative OMRON HEALTHCARE EUROPE B.V.,
Affiliate Companies OMRON HEALTHCARE (UK) LTD, 18-20 The Business Park
12
Kruisweg 577, 2132 NA Hoofddorp Postbus 13, NL 2130 AA Hoofddorp, The Netherlands www.omron-healthcare.com
Henfield, West Sussex, BN5 9SL England. Tel: 0845 130 8050, Fax: 01273 495123, Email: information@eu.omron.com
OMRON MEDIZINTECHNIK, Handelsgesellschaft mbH Windeckstraße 81a, D-68163 Mannheim, Germany PZN: 30 98 577 Artikel nummer 053 000 000, www.omron-medizintechnik.de
Loading...