Timers - Asymmetric asher
ENYA series
7 time ranges
Wide input voltage range
1 change over contact
Width 17.5 mm
Installation design
Technical data
E1ZI10
Part No. 110101
1. Functions
Ip Asymmetric flasher pause first
Ii Asymmetric flasher pulse first
(A1-B1 bridged)
2. Time ranges
Time range Adjustment range
1s 50ms 1s
10s 500ms 10s
1min 3s 1min
10min 30s 10min
1h 3min 1h
10h 30min 10h
100h 5h 100h
3. Indicators
Green LED U/t ON: indication of supply voltage
Green LED U/t slow flashing: indication of time period t1
Green LED U/t fast flashing: indication of time period t2
Yellow LED R ON/OFF: indication of relay output
4. Mechanical design
Self-extinguishing plastic housing, IP rating IP40
Mounted on DIN-rail TS 35 according to EN 60715
Mounting position: any
Shockproof terminal connecting according to VBG 4 (PZ1 required),
IP rating IP20
Tightening torque: max. 1Nm
Terminal capacity:
1 x 0.5 to 2.5mm² with /without multicore cable end
1 x 4mm² without multicore cable end
2 x 0.5 to 1.5mm² with/without multicore cable end
2 x 2.5mm² flexible without multicore cable end
5. Input circuit
Supply voltage: terminals A1(+)-A2
12 to 240V AC/DC
Tolerance: -10% to +10%
Rated consumption: 4VA (1.5W)
Rated frequency: AC 48 to 63Hz
Duty cycle: 100%
Reset time: 100ms
Residual ripple to DC: 10%
Drop-out voltage: >30% of the supply voltage
Overvoltage category: III (in accordance with IEC 60664-1)
Rated surge voltage: 4kV
6. Output circuit
1 potential free change over contact
Rated voltage: 250V AC
Switching capacity: 2000VA (8A / 250V)
Fusing: 8A fast acting
Mechanical life: 20 x 106 operations
Elektrical life: 2 x 105 operations
at 1000VA resistive load
Switching frequency: max. 6/min at 1000VA resistive load
(in accordance with IEC 60947-5-1)
Overvoltage category: III (in accordance with IEC 60664-1)
Rated surge voltage: 4kV
7. Control input
Input not potential free: terminals A1-B1
Loadable: yes
Max. line length: 10m
Trigger level (sensitivity): automatic adaption to supply voltage
8. Accuracy
Base accuracy: ±1% maximum scale value
Adjustment accuracy: <5% maximum scale value
Repetition accuracy: <0.5% or ±5ms
Voltage influence: -
Temperature influence: ≤0.01% / °C
9. Ambient conditions
Ambient temperature: -25 to +55°C
Storage temperature: -25 to +70°C
Transport temperature: -25 to +70°C
Relative humidity: 15% to 85%
(in accordance with IEC 60721-3-3 class 3K3)
Pollution degree: 2, if built-in 3
(in accordance with IEC 60664-1)
10. Weight
Single packing: 72g
Package 10pcs: 670g per Package
www.tele-online.com

E1ZI10
Part No. 110101
Functions
Asymmetric asher pause rst (Ip)
When the supply voltage U is applied, the set interval t1 begins (green
LED U/t ashes slowly). After the interval t1 has expired, the output relay
R switches into on-position (yellow LED illuminated) and the set interval
t2 begins (green LED U/t ashes fast). After the interval t2 has expired,
the output relay switches into off-position (yellow LED not illumninated).
The output relay is triggered at the ratio of t1:t2 until the supply voltage
is interrupted.
U/t
LED
Asymmetric asher pulse rst (Ii)
When the supply voltage U is applied, the output relay R switches
into on-position (yellow LED illuminated) and the set interval t1 begins
(green LED U/t ashes slowly). After the interval t1 has expired, the
output relay switches into off-position (yellow LED not illuminated) and
the set interval t2 begins (green LED U/t ashes fast). After the interval
t2 has expired, the output relay switches into on-position (yellow LED
illuminated).
The output relay is triggered at the ratio of t1:t2 until the supply voltage
is interrupted.
U/t
LED
t2
t1
R
t2
t1
t1
Connections
Dimensions
A1 B1
Ii
Ip
A1 B1
Ii
45mm
44mm5mm
TELE Haase Steuergeräte Ges.m.b.H.
Vorarlberger Allee 38
AT-1230 Vienna, AUSTRIA
RELEASE 2017/01
Subject to alterations and errors
www.tele-online.com