Datasheet DVS58 DataSheet (Pepperl Fuchs)

Page 1
Singleturn absolute encoder DVS58
Technical data
General specifications
Detection type photoelectric sampling Device type Singleturn absolute encoder
Functional safety related parameters
MTTFd 80 a Mission Time (TM) 20 a L
1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load
10
Diagnostic Coverage (DC) 0 %
Electrical specifications
Model Number
DVS58
Features
• Industrial standard housing Ø58 mm
•16 Bit singleturn
• Galvanically isolated DeviceNet interface
•Servo or clamping flange
Description
In addition to the CANopen, PROFIBUS and AS­Interface rotary encoders, we have broadened our product line of bus-capable absolute encoders with the DVS58 for DeviceNet. Absolute encoders deliver an absolute step value for each angle setting. All these values are represented by code samples of one or more code disks. The code disks are screened by an infrared LED and the bit obtained sample is detected by means of an optical array. Its signals are electronically amplified and are forwarded on to the interface for processing. The absolute encoder has a maximum basic resolution of 65536 steps per revolution (16 Bits). The integrated CAN bus interface of the absolute encoder supports all DeviceNet functions. The following operating modes can be programmed, and can selectively be turned on or off:
Polled mode
•Cyclic Mode
Change of state mode
The device is designed for shaft mounting and is available in servo flange or clamping flange design.
Operating voltage U No-load supply current I
Time delay before availability t Linearity ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0,5 LSB at 12 Bit Output code binary code Code course (counting direction) cw ascending (clockwise rotation, code course ascending)
Interface
Interface type DeviceNet Resolution
Single turn up to 16 Bit Overall resolution up to 16 Bit
Transfer rate max. 0.5 MBit/s
Connection
Terminal compartment in removable housing cover
Standard conformity
Degree of protection DIN EN 60529, IP65
Climatic testing DIN EN 60068-2-30 , no moisture condensation Emitted interference DIN EN 61000-6-4 Noise immunity DIN EN 61000-6-2 Shock resistance DIN EN 60068-2-27, 100 g, 6 ms Vibration resistance DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz
Ambient conditions
Operating temperature -40 ... 85 °C (-40 ... 185 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Material
Combination 1 housing: powder coated aluminum
Combination 2 (Inox) housing: stainless steel
Mass approx. 550 g (combination 1)
Rotational speed max. 12000 min Moment of inertia 30 gcm Starting torque 3 Ncm (version without shaft seal) Shaft load
Axial 40 N Radial 110 N
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source
B
0
v
10 ... 30 V DC max. 230 mA at 10 V DC
max. 100 mA at 24 V DC < 250 ms
cw descending (clockwise rotation, code course descending)
IP66 (with shaft seal)
flange: aluminum shaft: stainless steel
flange: stainless steel shaft: stainless steel
approx. 1000 g (combination 2)
-1
2
Release date: 2017-07-06 13:09 Date of issue: 2017-07-06 t49156_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Page 2
Singleturn absolute encoder DVS58
Dimensions
30 L
10
18
1
10h8
ø 58
ø 53
36f7
3 3.5
* Singleturn: L = 69, Multiturn : L = 80 ** Aluminum: d = 59, stainless steel: d = 61
4
6f6
ø 58
ø 50f7
10
d**
3
25
L
d**
12.7
27.5
27.5
ø 58
ø 58
3 x 120°
63
M4 x 0.7 6
M3 x 0.5 6
63
88
TK ø 48
M4 x 0.7 6
TK ø 42
15°
3 x 120°
40 60
3 x 120°
3
3
25
* Singleturn: L = 69, Multiturn : L = 80 ** Aluminum: d = 59, stainless steel: d = 61
-
12.7
40 60
Electrical connection
Terminal Cable M12 x 1 Connector Explanation
- - Ground connection for power supply
(+) Red 2 Power supply
(-) Black 3 Power supply
CG - 1 CAN ground
CL Blue 5 CAN low
CH White 4 CAN high
CG - - CAN ground
CL Blue - CAN low
CH White - CAN high
1
5
2
4
LEDs
3
Indicating and operating elements
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Release date: 2017-07-06 13:09 Date of issue: 2017-07-06 t49156_eng.xml
Page 3
Singleturn absolute encoder DVS58
Termination resistor
Supply voltage
R
T
ON
RS 485 interface
Error indicator LED green
LLH
-+
0
9 1
8 7
4
6
5
Bus In
Baud rate
2
G
H
G
0
0
9 1
9 1
2
2
8
3
7
2
8
3
3
7
4
4
6
6
5
5
x1
x10Bd
Bus Out
Addressing
Adjusting the participant address
The participant address can be adjusted with the rotary switches. The address can be defined between 1 and 63, and may only be assigned once.
Adjusting the termination resistor
R
The terminating resistor R of the switch:
(121 ) can be connected to the circuit by means
T
ON
T
participant X last participant
Baud rate adjustment
Baud rate [kBit/s] Switch position
125 0 250 1 500 2 125 3
reserved 4 ... 9
LED-indicators
LED red LED green Meaning
off off No voltage supply off on Encoder ready, boot-up message not transmitted, yet. Possible reasons:
- no further participant present
- wrong baud rate
- encoder in prepared status
flashing on Boot-up message transmitted, Device configuration possible.
on on Normal operation mode, encoder in operational status.
Status indicator
LED green
StaErr
'
& %
$
#
'
!
"
&
!
%
"
$
#
N N
R
T
ON
Release date: 2017-07-06 13:09 Date of issue: 2017-07-06 t49156_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3
Page 4
Singleturn absolute encoder DVS58
Programmable CAN operating modes
Mode Explanation
Polled mode
Cyclic mode
Change of state mode
Programmable rotary encoder parameters
Parameter Explanation
Operating parameter
Resolution per revolution
Preset value
Accessories
The connected host requests the current actual position value via a telegram. The absolute encoder reads in the current position, calculates all parameters that may have been set and then sends back the actual process value.
The absolute encoder sends the current process value depending on a programmable timer. This can cause the bus load to be reduced since the member on the network only sends a message after a specific amount of time without a prompt from the master.
The absolute encoder monitors the current process value and transfers the current value by itself if there is any change in the value. This can cause the bus load to be reduced, since the member on the network only sends a message if there has been a change.
The direction of rotation (complement) can be specified by parameter as the operating parameter. This parameter determines the direction of rotation in which the output code will be rising or descending.
The "Resolution" parameter is used to program the rotary encoder so that a desired number of steps can be implemented in reference to a revolution.
The preset value is the desired position value that must be achieved for a specific physical setting of the axis. The preset value parameter is used to set the actual position value to the desired actual process value.
For type Accessories Name/defining feature Order code
D1: Ø10 mm, D2: Ø10 mm 9401
Couplings
Measurement wheels with
DVS58N-011
DVS58N-032
For additional information on the accessories, please see the "Accessories" section.
circumference of 500 mm
Measurement wheels with circumference of 200 mm
Mounting aids
Couplings
Mounting aids
D1: Ø10 mm, D2: Ø10 mm 9404
D1: Ø10 mm, D2: Ø10 mm 9409
D1: Ø10 mm, D2: Ø10 mm KW
Plastic 9101, 10
Pimpled rubber 9102, 10
Knurled aluminium 9103, 10
Knurled plastic 9112, 10
Plastic 9108, 10
Pimpled rubber 9109, 10
Knurled aluminium 9110, 10
Knurled plastic 9113, 10
Mounting bracket 9203
Mounting bracket 9213
D1: Ø6 mm, D2: Ø6 mm 9401
D1: Ø6 mm, D2: Ø6 mm 9402
D1: Ø6 mm, D2: Ø6 mm 9404
D1: Ø6 mm, D2: Ø6 mm 9409
D1: Ø6 mm, D2: Ø6 mm KW
Mounting bracket and set 9300 and 9311-3
Eccentric clamping elements 9310-3
Release date: 2017-07-06 13:09 Date of issue: 2017-07-06 t49156_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4
Page 5
Singleturn absolute encoder DVS58
Order code
DVS5 8 R0BN– 0 0
Number of bits singleturn
12 4096 (standard)
13 8192
16 65536
Option 2
N Not expanded
Output code
B Binary
Option 1
0 No option
Exit position
R Radial
Connection type
AG Removable housing cover with terminal compartment
AN Removable housing cover with connectors M12x1
Shaft dimension/flange version
011 Shaft Ø10 mm x 20 mm with clamping flange
032 Shaft Ø6 mm x 10 mm with servo flange
Housing material
N Aluminium, powder coated
I Inox
W Aluminium, powder coated with shaft seal
Principle of operation
S Singleturn
Shaft version
V Solid shaft
Data format
D DeviceNet
Release date: 2017-07-06 13:09 Date of issue: 2017-07-06 t49156_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
5
Loading...