Datasheet DRP-480-24 Specification

Page 1
480W Single Output Industrial DIN RAIL with PFC Function
DRP-480 series
SPECIFICATION
MODEL
DC VO LTAG E
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
NOTE
EFFICIENCY (Typ.)
AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT
VIBRATION SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSIONOTHERS
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃ https://www.meanwell.com/serviceDisclaimer.aspx Product Liability Disclaimer For detailed information, please refer to
Features :
Built-in passive PFC function compliance to EN61000-3-2High efficiency 89% and low dissipationProtections: Short circuit / Overload / Over voltage /
Over temperature
Cooling by free air convectionBuilt-in constant current limiting circuitCan be installed on DIN rail TS-35/7.5 or 15UL 508(industrial control equipment)approvedEN61000-6-2(EN50082-2) industrial immunity level100% full load burn-in test3 years warranty
DRP-480-24
24V
20A
0 ~ 20A
480W
Note.2
120mVp-p
24 ~ 28V
±1.0% ±0.5% ±1.0%
1200ms, 40ms/230VAC at full load
16ms/230VAC at full load
180 ~ 264VAC 250 ~ 370VDC
47 ~ 63Hz
0.7
89%
4A/230VAC COLD START 40A/230VAC
<3.5mA / 240VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
30 ~ 36V
Protection type : Shut down o/p voltage, re-power on to recover
100 5 (TSW : detect on heatsink of power switch)℃± ℃
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃ ℃)0.03%/ (0 ~ 50 Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL508, UL60950-1 approved
I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020
180.9Khrs min. MIL-HDBK-217F (25 )
227*125.2*100mm (W*H*D)
2.4Kg; 6pcs/15Kg/1.46CUFT
, EAC TP TC 004
/ 25 / 70% RH
DRP-480-48
48V
10A
0 ~ 10A
480W
120mVp-p
48 ~ 53V
±1.0% ±0.5% ±1.0%
54 ~ 60V
UL508
User’s Manual
UL60950 1-
TPTC004
File Name:DRP-480-SPEC 2021-09-15
Page 2
480W Single Output Industrial DIN RAIL with PFC Function
DRP-480 series
Mechanical Specification
35
ADMISSIBLE DIN-RAIL: TS35/7.5 OR TS35/15
227100
TB1 TB2
312
LED
+V ADJ.
Case No.930 Unit:mm
125.2
34
21
Terminal Pin No. Assignment (TB1)
Pin N o.
Assignment
1
AC/L(DC+)
2
AC/N(DC-)
3
FG
Terminal Pin No. Assignment (TB2)
Pin N o.
Assignment
DC OUTPUT +V
1,2
DC OUTPUT -V
3,4
Block Diagram
RECTIFIERS
&
FILTER
DETECTION
CIRCUIT
CURRENT
LIMIT
O.V.P.
FG
I/P
EMI PASSIVE
FILTER PFC
RECTIFIERS
&
FILTER
O.L.P.
O.T.P.
SWITCHING
PWM
CONTROL
POWER
Derating Curve Output Derating VS Input Voltage
100
80
60
40
LOAD (%)
20
-20010203040506070 (VERTICAL)
100
90
80
70
60
50
LOAD (%)
40
180 190 200 264
fosc : 70KHz
+V
-V
AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz
File Name:DRP-480-SPEC 2021-09-15
Loading...