Datasheet DMS-40LCD-1-2-9, DMS-40LCD-1-2-5B, DMS-40LCD-1-2-5, DMS-40LCD-0-1-9B, DMS-40LCD-0-1-9 Datasheet (DATEL)

...
Page 1
DATEL, Inc., Mansfield, MA 02048 (USA) • Tel: (508)339-3000, (800) 233-2765 Fax: (508)339-6356 Email: sales@datel.com • Internet: www.datel.com
4½ Digit, LCD Display
Low-Power, Miniature
Digital Panel Voltmeters
DMS-40LCD Series
Figure 1. DMS-40LCD Series Simplified Schematic
••
••
Scientific-grade accuracy, ±2 counts
••
••
Low power, typically 12.5mW
••
••
Miniature size:
2.17" x 0.92" x 0.43" 55mm x 23mm x 11mm
••
••
Large (0.4"/10.2mm), enhanced­contrast, LCD display
••
••
Backlit displays optional
••
••
Epoxy-encapsulated, 12-pin DIP
••
••
Panel or pc-board mountable
••
••
3 differential, dual, input voltage ranges
••
••
Single +5V supply or 9V battery
••
••
User-selectable decimal point placement
••
••
Low-battery "BAT" annunciator
••
••
0 to +50°C temperature range
••
••
Low Cost
Offering a unique combination of low cost, scientific-grade accuracy (±2 counts), component-like convenience and outstanding reliability, DMS-40LCD Series 4½ Digit DPM's provide the ultimate combination of price, precision and convenience. These miniature (2.17" x 0.92" x 0.43") digital voltmeters combine an advanced, autozeroing A/D converter, a precision reference circuit and a large (0.4"/10.2mm high), easy-to­read LCD display in a single, fully encapsulated, 12-pin DIP package. All models incorporate a built-in bezel and are easily mounted in either panels or pc boards.
Each DMS-40LCD meter has a dual-range, differential, input configuration (±200mV/±2V, ±2V/±20V or ±20V/±200V) and is available with a backlit or non-backlit display. Input impedance is a minim um 800k , and CMRR is typically 86dB (dc to 60Hz). CMV is ±2V, and all models are overvoltage protected to ±250V (on their non­inverting inputs).
All DMS-40LCD meters are fully functional and operate from a single +5V supply (drawing 3.5mA max.) or a single 9V supply/battery (drawing 2.5mA max.). All models feature autopolarity changeover and overrange indication. A displa y HOLD function is standard on all non-backlit models.
Thanks to their rugged epoxy-based encapsulation and their advanced, factory­calibrated A/D converters, DMS-40LCD meters are able to withstand the harshest environments and never require adjustment or calibration. Plug-in convenience, long­term stability and wide operating temperature range (0 to +50°C) make DMS-40LCD meters the right solution for any high-accuracy DPM requirement.
Features
Actual Size
(+) INPUT HI
(–) INPUT L
O
ANALOG COMMON
REFERENCE IN/OUT
+5V SUPPLY/
+BATTERY
R1
DP 1
DP 2
DP 3
6
5
4
9
11
12
10
8
7
1
3
DC/DC
CONVERTER
2
5V RETURN/
–BATTERY
+5V
–5V
+5V
1.23V REF.
R2
»
+2.2V
DATA
V+
V–
A/D
CONVERTER
0 Vdc
0.01µF
J1
BAT
R1 = 100k on ±200mV/±2V (-0/1) models and 909k on all other models. R2 is not used on ±200mV/±2V (-0/1) models. R2 = 101k on ±2V/±20V (-1/2) models and 9.2k on ±20V/±200V (-2/3) models.
HOLD/ BACKLIGHT
BAT
➁ DC/DC converter is not used on 9V-powered models,
J1 is connected.
RANGE
SELECT
DP 4
➂ Hold function is not available on backlit models.
®®
www.datel.com
Page 2
2
DMS-40LCD - 0/1 - 5
Each model in the DMS-40LCD Series offers two input voltage ranges that are user-selectable via pin strapping. 5V-powered models can be used to perform either differential or single-ended measurements. 9V­powered models can only be used for differential measurements.
Applies for transient or continuous overvoltages applied to (+) INPUT HI (pin 11) with (–) INPUT LO (pin 12) properly connected. Pin 12 is not overvoltage protected (see Figure 1). Voltages applied to pin 12 should not exceed the supply voltage.
Listed spec applies to 5V-powered models only. For 9V-powered models, both (–) INPUT LO (pin 12) and (+) INPUT HIGH (pin 11) must always be at least 1.5V above –BATTERY (pin 3) and at least 1.5V below +BATTERY (pin 1).
See Technical Notes.
Performance/Functional Specifications
Typical at TA = +25°C and supply voltage = +5V (using the single-ended input circuit) or +9V (using the differential input circuit), unless otherwise noted.
DMS-40LCD
T echnical Notes
1. Input V oltage Range Selection: Each model in the DMS-40LCD
Series offers two, user-selectable, input voltage ranges as indicated in the Perfor mance/Functional Specifications Table and the Ordering Information. To select the higher range of any device (such as the ±2V range for the DMS-40LCD-0/1), connect pin 2 (RANGE SELECT) to pin 1 (+5V SUPPLY/+BATTERY). To select the lower range, leave pin 2 open.
2. Decimal Point Placement: The location of the decimal point is user-selectable, and the decimal point control pins (DP1-DP4) are active low functions. Select the appropriate decimal point by tying the appropriate pin (pin 4, 5, 6 or 8) to pin 3 (5V RETURN/ –BATTERY). Unused decimal point location pins should be left open. For 5V-powered models, the decimal location pins are TTL compatible and may be hard wired as described above or driven with 5V TTL logic gates.
3. Low Battery Annunciator: The "BAT" annunciator in the upper left-hand corner of the display turns on when the supply voltage for 5V-powered models falls below approximately +3.75V or when the supply voltage for 9V-powered models falls below approxi­mately 7.2V. This function can not be disabled.
Leave blank for standard models. Add B for backlit models.
Power Source:
5 = +5V 9 = +9V
Accessories:
DMS-30-CP Panel cutout punch DMS-BZL1 DMS-40 bezel assembly DMS-BZL2 DMS-40 bezel assembly with sealing gasket DMS-EB Application/evaluation board with standard
MOLEX connector, decimal point solder pads and attenuation resistor pads.
4½ DIGIT, LCD DISPLAY DIGITAL PANEL VOLTMETERS
Ordering Information
Input Ranges:
0/1 = ±200mV/±2V 1/2 = ±2V/±20V 2/3 = ±20V/±200V
A panel-mount retaining clip is supplied with each model.
Analog Inputs Min. Typ. Max. Units Full Scale Input Range:
DMS-40LCD-0/1 -- ±200/±2 -- mV/V DMS-40LCD-1/2 -- ±2/±20 -- V/V DMS-40LCD-2/3 -- ±20/±200 -- V/V
Input Impedance:
DMS-40LCD-0/1 100 1000 -- M
DMS-40LCD-1/2 0.8 1 -- M
DMS-40LCD-2/3 0.8 1 -- M
Overvoltage Protection
-- -- ±250 Volts
Common Mode Voltage Range
-- -- ±2 Volts
CMRR (dc to 60Hz) -- 86 -- dB Control Inputs Decimal Point Placement (Pins 4-6, 8):
Functionality Tie to pin 3 to activate Logic Compatibility TTL (on 5V-powered models)
Hold/Backlight Functionality (Pin 9):
Backlit Models Tie to pin 3 to turn on backlight Non-backlit Models Tie to pin 3 to hold last reading
Performance Sampling Rate 2.5 samples per second Accuracy (3 minute warm-up):
DMS-40LCD-0/1 (VIN = +0.19/1.9V) -- ±2 ±3 Counts DMS-40LCD-1/2 (VIN = +1.9V) -- ±2 ±3 Counts DMS-40LCD-1/2 (VIN = +19V) -- ± 3 ±4 Counts DMS-40LCD-2/3 (VIN = +19/190V) -- ±3 ±4 Counts
Zero Reading (VIN = 0 Volts) "–0001" "0000" "0001" Temperature Drift (0 to +50°C):
DMS-40LCD-0/1 -- ±0.4 ±0.8 Cnts/°C DMS-40LCD-1/2 -- ±0.6 ±1 Cnts/°C DMS-40LCD-2/3 -- ±0.6 ±1 Cnts/°C
Power Supply Requirements (5V Models) Supply Voltage +4.75 +5.00 +5.25 Volts Supply Current:
Standard Models -- +2.5 +3.5 mA Backlit Models -- +37 +45 mA
Power Supply Requirements (9V Models
)
Supply Voltage +7.5 +9.0 +14.0 Volts Supply Current:
Standard Models -- +1.5 +2.5 mA Backlit Models -- +37 +45 mA
Display Display Type and Size 4½ Digit LCD, 0.4"/10.2mm high Polarity Indication Autopolarity ("–" for negative VIN) Overrange Indication "–1____" for negative VIN
"1____" for positive V IN
Physical/Environmental Operating Temperature 0--+50°C Storage Temperature 20 -- +75 °C Humidity (Non-condensing) 0 -- 95 % Case Material Polycarbonate Weight 0.75 ounces (21 grams)
Order on-line at www.datel.com
Page 3
2
RSeries = Ohms
+12.6 – 9.2V
0.035
R
Series = Ohms
+BATTERY – 9.2V
0.035
Example: If +BATTERY (pin 1 with respect to pin 3) is +12.6V,
R
Series = 97 Ohms
Applications
4½ DIGIT, LCD DISPLAY DIGITAL PANEL VOLTMETERS
DMS-40LCD
1. Single-Ended Input Configurations: True single-ended
measurements can only be made with 5V-powered meters. The circuit of Figure 2 avoids problems normally associated with ground loop currents. Separate ground runs should be used for 5V RETURN (pin 3) and (–) INPUT LO (pin 12).
DMS-40LCD meters are available in either 5V-powered or 9V­powered models. 9V devices operate directly from 7.5V to 14V supplies (usually batteries) without the need for external voltage regulators. 9V devices, however, can not be used to measure voltages referenced to the negativ e battery terminal (pin 3) because the minus input to the meter (pin 12, (–) INPUT LO) must always be at least 1.5V above pin 3. 9V-powered meters can only be used to make differential and not single-ended measurements.
5V-powered devices operate from any well-regulated +5V supply and will accurately measure voltages both above and below pin 3 (5V RETURN) in either single-ended or differential configurations.
9. Suggested Mating Connectors:
Panel mounted:
Connector housing DATEL P/N 39-2079400 Terminal type DATEL P/N 39-2099090 Crimping tool DATEL P/N 39-2099000 Wire size 22 to 26 AWG Insulation diameter 0.062" (1.57mm) maximum Stripping length 0.100 to 0.125" (2.54 to 3.17mm)
Board mounted:
Socket DATEL P/N 39-2359625
4. HOLD/BACKLIGHT (Pin 9) Function: For non-backlit models, connecting pin 9 (HOLD/BACKLIGHT) to pin 3 (5V RETURN/ –BATTERY) will hold (continuously display) the last reading. If not used, pin 9 should be left open for these models.
For backlit models, grounding pin 9 (i.e. connecting it to pin 3) turns on the backlighting LED's. 9V-powered backlit models function with supply voltages up to +14V, however, activating the backlight with voltages greater than 9.2V can damage the meter. Therefore, a 1/4 Watt series resistor must be installed between pins 3 and 9 in these situations. The value of the series resistor is determined using the following formula:
In any backlit application, including those with supply voltages < 9.2V, the current drawn by the backlight (and therefore the current drawn by the meter) can be reduced by installing a 1/4 Watt resistor between pins 3 and 9. The brightness of the backlight will be reduced proportionately.
5. ANALOG COMMON (Pin 10): This pin is connected to an internal, low-noise, "relative" ground. It is used in certain floating measurements as described in the Applications section of this data sheet and Ap Note 3 of the DATEL Panel Meter Catalog. Pin 10 should not be connected to pin 3 (5V
RETURN/–BATTERY) or to your system’s analog ground.
6. REFERENCE IN/OUT (Pin 7): This pin accesses the meter's
internal reference and is used during the factory calibration procedure. Pin 7 should be left open in most common applica­tions. It can be used in certain "ratiometric" applications in which it is desireable for the meter's reference to track an external reference. See the Applications section of the DATEL Panel Meter Catalog for more details.
7. Gain Adjust: There is a gain-adjust potentiometer on the back of each meter. It has approximately ±150 counts of adjustment range. Since these devices essentially have no zero/offset errors, a gain adjustment is effectively an overall accuracy adjustment. Though they may be performed at any point (except zero), accuracy adjustments are most effectiv e when performed with higher level input signals.
8. Soldering Methods: All models in the DMS-40LCD Series easily withstand most common wave soldering operations. We recommend, however, you evaluate the effects your particular soldering techniques may have on the meter's plastic case and high-precision electrical performance. We recommend the use of water-soluble solders and thorough cleaning procedures.
Figure 2. Single-Ended Input Configuration
(5V- Powered Models)
1
12
3
+5V SUP
(–) IN LO
5V RET
DATEL
UPA-5/500
120 VAC
11
(+) IN HI
6
DP1
+
AC to DC Converter
V
IN
DMS-40LCD-0/1-5
2
RANGE
Page 4
4
2. Differential Input Configurations: Differential measurements can be made with either 5V-powered or 9V-po wered meters. Figure 3, though not a practical real-world application, uses a voltage divider to demonstrate the concept of a differential input signal. Be careful not to exceed the ±2V common mode voltage limitation for 5V-powered meters.
4. Floating Signal Source Measurements: Floating signals can be measured using the circuits shown in Figures 5 and 6. Figure 5 uses a 5V-powered meter. Figure 6 uses a 9V-powered meter. Both figures show a DMS-40LCD-0/1 with pin 2 tied to pin 1 yielding a ±2V input range. Connecting pin 10 (ANALOG COMMON) to (–) INPUT LO (pin 12) provides the reference point for the meter’s input.
A "floating" input is a signal that has no galvanic connection to the meter's power supply. In the figures below, the 1.5V battery illustrates a true floating input.
DMS-40LCD
4½ DIGIT, LCD DISPLAY DIGITAL PANEL VOLTMETERS
Figure 5. Floating Input Measurements
(5V- Powered Models)
Figure 6. Floating Input Measurements
(9V- Powered Models)
Applications
Figure 3. Differential Input Configuration
(5V-Powered Models)
3. Engineering Scaling: For measuring voltages greater than the
full scale input range of a given meter, the input signal must be attenuated. A simple voltage divider (similar to that shown in Figure 4) will scale the input to within the range of the selected meter. R1 and R2 should be precision, ±1%, metal film resistors with absolute TCR's less than 50ppm/°C . See Ap Note 4 for more information on engineering scaling.
50k
< R1 + R2 < 10M
R2
R1 + R2
x VIN = Reading
Figure 4. Input Attenuation Circuit
1
12
3
+5V SUP
(–) IN LO
5V RET
DATEL
UPA-5/500
120 VAC
11
(+) IN HI
6
DP1
AC to DC Converter
R2
R1
R3
1k
1k
1k
2
RANGE
DMS-40LCD-0/1-5
R2
11 12
3
(+) IN HI (–) IN L O 5V RET
V
IN
R1
+
DMS-40LCD-0/1-5
1
3
+5V SUP 5V RET
DATEL
UPA-5/500
120 VAC
6
DP1
AC to DC Converter
2
RANGE
12
(–) IN LO
10
ANA COMM
11
(+) IN HI
1.5V
C
ELL
+
DMS-40LCD-0/1-5
13
+ BAT
–BAT
9V
BATTERY
6
DP1
2
RANGE
12
(–) IN LO
10
ANA COMM
11
(+) IN HI
1.5V
C
ELL
+
+
DMS-40LCD-0/1-9
Page 5
4
6. Power Supply Monitoring: A popular application for DATEL's
low-power LCD meters is monitoring the supply voltage in battery-operated portable equipment. Figure 8 demonstrates how a 9V-powered DMS-40LCD can be used to monitor its own supply. The meter used is the DMS-40LCD-0/1-9 configured for its ±2V input range (pin 2 connected to pin 1). A three-resistor voltage divider is used to attenuate the battery voltage and also to satisfy the requirement that the input voltages applied to pins 12 and 11 be at least 1.5 Volts above and below the battery voltage applied to pins 1 (+BATTERY) and 3 (–BATTERY).
The divider should be designed so that 1/10th the battery voltage
falls across the inputs to the meter.
Therefore, the 9V battery voltage appears to the meter inputs as
0.9V. With the decimal point moved to its DP2 position (pin 5 tied to pin 3), the meter reads 9.000 Volts.
The circuit can be calibrated by first measuring the actual battery voltage with another meter and then adjusting the gain-adjust potentiometer on the back of the DMS-40LCD until a similar reading is obtained. If possible, the resistors in the divider should be ±1% metal-film types with TCR’s less than 50ppm/°C.
4½ DIGIT, LCD DISPLAY DIGITAL PANEL VOLTMETERS
DMS-40LCD
R2 (R1 + R2 + R3)
= 0.1
5. Process Control (4-to-20mA) Measurements: In many common process-control applications, a 4-to-20mA current loop is used to transmit information. Because DMS-40LCD meters have such high input impedance, a simple shunt resistor across the meters input can be used to convert the loop current to a voltage. See Figure 7. The value of the shunt resistor is a function of the scaling requirements of the particular application and can be calculated using the following equation:
Figure 7. 4-to-20mA Current Loop Operation
(5V-Powered Models)
Figure 8. Power Supply Monitor
(9V- Powered Models)
Applications
To calibrate the circuit of Figure 7, perform the following:
1. With 4mA applied, adjust the 50kΩ potentiometer (R2) to display a reading of "0000" (assuming that is the desired reading).
2. With 20mA applied, adjust the gain-adjust potentiometer on the back of the meter to display a reading of "19999". For different full scale readings, alter the value of RShunt accordingly.
R
Shunt = R1 = VFsr/IFsr
Where: VFsr = Full scale reading (in Volts)
I
Fsr = Relative full scale current (in Amps)
Example: For a meter with a 2V full scale input (1.999 full scale reading) and a desired full scale display reading of 1000 (with an input of 20mA), VFsr = 1.000 Volts
R
Shunt = 1.000V/(0.020 – 0.004)A
RShunt = 1.000V/0.016A = 62.5 Ohms
1
3
+5V SUP
5V RET
DATEL
UPA-5/500
120 VAC
AC to DC Converter
2
RANGE
12
(–) IN LO
10
ANA COMM
11
(+) IN HI
R1
+
4
-20mA
50k
R2
DMS-40LCD-0/1-5
1
12
3
+BAT
(–) IN LO
–BAT
11
(+) IN HI
5
DP2
R2
R1
R3
45.3k
10.1k
2
RANGE
45.3k
9V
BATTERY
+
DMS-40LCD-0/1-9
Page 6
DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 Internet: www.datel.com Email: sales@datel.com Data sheet fax back: (508) 261-2857
DATEL (UK) LTD. Tadley, England Tel: (01256)-880444 DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 01-34-60-01-01 DATEL GmbH München, Germany Tel: 89-544334-0 DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-354-2025
DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL, Inc. trademark.
®®
ISO 9001
ISO 9001
REGISTERED
DS-0283B 1/98
DMS-40LCD
4½ DIGIT, LCD DISPLAY DIGITAL PANEL VOLTMETERS
MECHANICAL DIMENSIONS: Inches (mm) TOLERANCES: 2 PL DEC ±0.02 (±0.51)
3 PL DEC ±0.010 (±0.254) LEAD DIMENSIONS: 0.025 (0.635) x 0.025 (0.635) NOMINAL RECOMMENDED PC BOARD FINISHED HOLE DIAMETER:
0.042 ±0.003 (1.067 ±0.076)
Mechanical Specifications


BEZEL INSTALLATION


#2-56 INSERT
0.156 (3.96) DEEP
FRONT VIEW
1.270
(32.26)
0.187 (4.75)
OPTIONAL BEZEL (DMS-BZL1 and DMS-BZL2)
2.35 (59.69)
2.118 (53.80)
0.093 (2.362) DIAMETER (4 REQUIRED) ONLY WHEN USING OPTIONAL BEZEL ASSEMBLY
RECOMMENDED DRILL AND PANEL CUTOUT DIMENSIONS
INTERNAL CORNER RADII:
0.032 (0.81) MAX.
1.07
(27.18)
0.878
(22.30)
0.096 (2.44)
0.116 (2.95)
2.55 (64.77)
PANEL CUTOUT
RETAINING CLIP INSTALLATION

MADE IN USA
DMS-40LCD-X/X-XX
FRONT VIEW
+5V SUPPLY/ +BATTERY
RANGE SELECT
5V RETURN/ –BATTERY
DP3 DP2 DP1
1 2 3 4 5 6
(–) INPUT LO (+) INPUT HI ANALOG COMMON HOLD/BACKLIGHT DP4 REFERENCE IN/OUT
12 11 10
9 8 7
DP1 DP2 DP3 DP4
2.17
(55.1)
2.09
(53.1)
1.80
(45.7)
0.25 (6.4) TYP.
0.15 (3.7) TYP.
0.10 (2.5) TYP.
0.040 (1.02)
0.17 (4.3) TYP.
0.50
(12.7)
0.84
(21.3)
0.92
(23.4)
PIN #1
IDENTIFIER
0.430 (10.92) STANDARD
0.560 (14.22) BACKLIT
®
®
0.040 (1.02)
0.325 (8.26)
0.290 (7.37)
PIN 1
CALIBRATION POTENTIOMETER HOLE LOCATION
0.125 (3.175) DIAMETER
(USE ONLY WHEN PC BOARD MOUNTING)
0.040 (1.02)
Loading...