Datasheet DMS-20PC-1-AS, DMS-20PC-3-YS, DMS-20PC-3-RSH, DMS-20PC-3-RS, DMS-20PC-3-RL Datasheet (DATEL)

...
Page 1
DATEL, Inc., Mansfield, MA 02048 (USA) • Tel: (508)339-3000, (800) 233-2765 Fax: (508)339-6356 E-mail: sales@datel.com • Internet: www.datel.com
Features
DMS-20PC Series, 3½ Digit, LED Display, Digital Panel Voltmeters combine a precision A/D converter; a factory-trimmed, highly stable, voltage reference; and a large (0.37"/9.4mm), easy-to-read LED display in a single package that is only slightly larger than the display itself. Displays are offered in either red, orange, amber, yellow or green colors. High-intensity and low-power (35mW total) red LED's are also optional.
The meters come with one of four, differential, input voltage ranges: ±200mV, ±2V ±20V or ±200V. Input impedance is a minimum 800k. CMRR is typically 86dB (dc to 60Hz), and CMV is ±2V. Input overvoltage protection (on the non-inverting input) is ±250V. Devices are fully calibrated at the factory to an accuracy of ±1 count (±0.05% of full scale range) and never require calibration or adjustment.
A DISPLAY ENABLE function permits the display to be disabled for "power­down" operation. All models have a DISPLAY TEST function. Standard red LED models offer an optional DISPLAY HOLD function.
Small size, low cost and adjustment-free reliability make the DMS-20PC Series the best choice for all your 3½ digit, LED, DPM applications.
Figure 1. DMS-20PC Series Simplified Schematic
••
••
Lowest-cost LED meters
••
••
Subminiature size:
1.38" x 0.88" x 0.48" 35mm x 22mm x 12mm
••
••
Large (0.37"/9.4mm) LED display
••
••
Choice of 5 LED colors
••
••
High-intensity or low-power (7mA) red LED's optional
••
••
Epoxy-encapsulated, 12-pin DIP package with built-in color filter and bezel
••
••
4 differential input voltage ranges
••
••
Factory calibrated, ±1 count accuracy
••
••
Single +5V power supply
••
••
User-selectable decimal point placement
••
••
DISPLAY ENABLE function for "power-down" mode
••
••
DISPLAY TEST and HOLD (optional) functions
••
••
0 to +60°C temperature range
3½ Digit, LED Display
Low-Cost, Subminiature
Digital Panel Voltmeters
DMS-20PC Series
Actual Size
(+) INPUT HI
(–) INPUT LO
ANALOG COMMON
REFERENCE OUT
REFERENCE IN
+5V SUPPLY
R1
DP 1
DP 2
DP 3
6
5
4
11
12
10
8
7
1
3
DC/DC
CONVERTER
2
5V RETURN
+5V
–5V
R2
»
+2.0V
DATA
909k
V+
V–
A/D
CONVERTER
0 Vdc
0.01 µF
9
DISPLAY
ENABLE
+5V
R2 is not used on ± 2 0 0 mV (-0) models or ±2V (-1) mode ls. R2 = 100k on ±20V (-2) models and 9.1k on ±200V (-3) models.
Only used on ±200mV (-0) and ±2V (-1) models.
DISPLAY TEST/HOLD
11
Pin 9 is DISPLAY TEST on all but eight models. On those models
(
-H option), it is DISPLAY HO L D.
1
2
3
2
1
3
®®
www.datel.com
Page 2
2
DMS-20PC
3½ DIGIT, LED DISPLAY DIGITAL PANEL VOLTMETERS
Performance/Functional Specifications
Typical at TA = +25°C and supply voltage = +5V using the single-ended input circuit, unless otherwise noted.
Applies for transient or continuous overvoltages applied to (+) INPUT HI (pin 11) with (–) INPUT LO (pin 12) properly connected. Pin 12 is not overvoltage protected (see Figure 1). Voltages applied to pin 12 should not exceed the supply voltage.
See Technical Notes.
The DISPLAY HOLD function is optional on standard red and green LED models only. See Ordering Information.
Leave blank for standard models. Add -H for DISPLAY HOLD option (available on standard red and green LED models only).
DMS-20PC-1- RS
LED Color:
AS = Standard Amber GS = Standard Green OS = Standard Orange RS = Standard Red
YS = Standard Yellow RH = High-Intensity Red RL = Low-Power Red
Accessories:
DMS-20-CP Panel cutout punch DMS-BZL3 DMS-20 bezel assembly DMS-BZL4 DMS-20 bezel assembly with sealing gasket DMS-EB2 Application/evaluation board with standard
MOLEX connector, decimal point solder pads and attenuation resistor pads.
T echnical Notes
1. REFERENCE OUTPUT (Pin 8) and INPUT (Pin 7): Pin 8 is a
precision reference actively trimmed at the factory. In normal operation, pin 8 must be tied to pin 7 to achieve all listed accuracy and drift specifications.
2. ANALOG COMMON (Pin 10): This pin is connected to an internal, low-noise, "relative" ground. It is used in certain differential and "floating" measurements as described in the Applications section of this data sheet and Ap Note 3 of the DATEL Panel Meter Catalog.
Pin 10 should not be connected to pin 3 (5V RETURN) or to your system’s analog ground.
3. Decimal Point Placement: The location of the decimal point is
user-selectable, and the decimal point control pins (DP1-DP3) are active low functions. Select the appropriate decimal point by tying the appropriate pin (pin 4, 5 or 6) to pin 3 (5V RETURN). Unused decimal point location pins should be left open.
Hard wiring is preferable, however, you can use logic gates to exercise dynamic control over the location of the decimal point if the following drive conditions are met:
Model Applied "0" Voltage Load Current* DMS-20PC-X-RL +0.05V max. 0.7mA max. All Others +0.4V max. 6mA max.
* The driving gates must be able to sink this much current
(I
OL) with a logic "0" output.
Ordering Information
Input Range:
0 = ±200mV 1 = ±2V 2 = ±20V 3 = ±200V
A panel-mount retaining clip is supplied with each model.
Analog Inputs Min. Typ. Max. Units Full Scale Input Range:
DMS-20PC-0 -- ±200 -- m V DMS-20PC-1 -- ±2 -- Volts DMS-20PC-2 -- ±20 -- Volts DMS-20PC-3 -- ±200 -- Volts
Input Impedance:
DMS-20PC-0, -1 100 1000 -- M
DMS-20PC-2, -3 0.8 1 -- M
Overvoltage Protection
-- -- ±250 Volts
Common Mode Voltage Range -- -- ±2 Volts CMRR (dc to 60Hz) -- 86 -- dB Control Inputs ➁ ➂ Decimal Point Placement (Pins 4-6) Tie to pin 3 to activate Display Test (Pin 9) Tie to pin 1 to activate all segments Display Hold (Pin 9)
Tie to pin 1 to hold last reading
Performance Sampling Rate 2.5 samples per second Accuracy (3 minute warm-up):
DMS-20PC-0 (VIN = +0.19V) -- ±1 ±3 Counts DMS-20PC-1 (VIN = +1.9V) -- ±1 ±3 Counts DMS-20PC-2 (VIN = +19V) -- ±2 ±3 Counts DMS-20PC-3 (VIN = +190V) -- ±2 ±3 Counts
Zero Reading (VIN = 0 Volts) "–001" "000" "001" Temperature Drift (0 to +60°C) -- ±0.2 ±0.4 Cnts/°C Power Supply Requirements Supply Voltage + 4.75 +5.00 +5.25 Volts Supply Current:
DMS-20PC-X-RS -- +60 +90 mA DMS-20PC-X-RL -- +7 +12 mA DMS-20PC-X-AS -- +90 +120 mA DMS-20PC-X-GS -- +90 +120 mA DMS-20PC-X-OS -- +90 +120 mA DMS-20PC-X-YS -- +90 +120 mA DMS-20PC-X-RS-H -- +60 +90 mA DMS-20PC-X-GS-H -- +90 +120 mA DMS-20PC-X-RH -- +6 0 +90 mA
Display Display Type and Size 3½ Digit LED, 0.37"/9.4mm high Polarity Indication Autopolarity ("–" for negative VIN) Overrange Indication "–1___" for negative VIN
"1___" for positive VIN
Physical/Environmental Operating Temperature 0--+60°C Storage Temperature 40 -- +75 °C Humidity (Non-condensing) 0 -- 95 % Case Material Polycarbonate Weight 0.4 ounces (11 grams)
Order on-line at www.datel.com
Page 3
3
3½ DIGIT, LED DISPLAY DIGITAL PANEL VOLTMETERS
DMS-20PC
Applications
Figure 2. Single-Ended Input Configuration
8. Suggested Mating Connectors:
Panel mounted:
Connector housing DATEL P/N 39-2079400 Terminal type DATEL P/N 39-2099090 Crimping tool DATEL P/N 39-2099000 Wire size 22 to 26 AWG Insulation diameter 0.062" (1.57mm) maximum Stripping length 0.100 to 0.125" (2.54 to 3.17mm)
Board mounted:
Socket DATEL P/N 39-2359625
DMS-20PC meters are highly versatile devices that can be used in hundreds of applications. The application circuits chosen for this section are ones that have historically received many inquiries.
The schematic in Figure 1 shows that the meter's high-impedance input consists of an op amp powered from a ±5Vdc power supply (the –5V is internally generated). One can easily see why input signals applied to (–) INPUT LO and (+) INPUT HI have to be kept within the power supply rails of ±5V. Also note that only pin 11 has a current-limiting 909k
series resistor. High input voltages that have a common ground with pin 3 (5V RETURN) should only be applied to pin 11 ((+) INPUT HI) and never to pin 12. In these high-voltage cases, pin 12 should always be tied to pin 3 (5V RETURN).
The schematic also shows that pin 3 is the meter's zero-volt reference point regardless of the type of power or signal source used. This is an important point to keep in mind when a digital or analog multimeter is used to make system measurements. The multimeter's negative lead (usually the black one) must be connected to pin 3 (5V RETURN).
1. Single-Ended Input Configurations: True single-ended
measurements can be made with any DMS-20PC meter. The circuit of Figure 2 avoids problems normally associated with ground-loop currents. Separate ground runs should be used for 5V RETURN (pin 3) and (–) INPUT LO (pin 12).
4. DISPLAY TEST/HOLD (Pin 9) Function: Pin 9 is a dual-function pin. On all standard models (without "-H" suffix), tying pin 9 to pin 1 (+5V SUPPLY) activates the meter's DISPLAY TEST feature. All display segments, except the decimal points, will be illuminated. The display will show "1888" ("–1888" if a negative input signal is present). Do not leave the meter in the test
mode for more than 10 seconds as this will cause the meter's operating temperature to rise and possibly affect its performance. Pin 9 must be left open when the test function is
not being used. On models with the "-H" suffix (DMS-20PC-1-RS-H for example),
pin 9 serves as a DISPLAY HOLD control pin. Tying pin 9 to +5V SUPPLY (pin 1) on these models will hold or "freeze" the current display reading indefinitely. Pin 9 must also be left open when the hold function is not being used. After disabling DISPLAY HOLD, allow the meter a full 10 seconds to resume normal calibrated operation before holding a new reading.
The DISPLAY TEST or DISPLAY HOLD pin should normally be connected, via a selector switch, to pin 1 (+5V SUPPLY). If automatic, logic-controlled operation is desired, only PNP or MOSFET transistors should be used. The base or gate of these transistors should be driven sufficiently hard to bring pin 9 within
0.05V of +5V SUPPLY.
5. DISPLAY ENABLE (Pin 2) Function: On all models, tying pin 2 to pin 1 (+5V SUPPLY) applies full power to the LED display. This is the normal mode of operating the meter. Leaving DISPLAY ENABLE open (no connection), only turns off the LED display. The meter's analog-to-digital converter continues to sample the input signal. Total current consumption with the display off is approximately 400µA (0.4mA). This is a very useful feature if the meter is used in battery-powered equipment.
With the exception of the low-power red LED models (DMS­20PC-X-RL), a regulated voltage lower than +5V SUPPLY can be used to dim the display intensity. Display intensity control is best performed with the high brightness, red LED, DMS-20PC-X-RH model. All lo w-power red LED models must have DISPLAY ENABLE tied directly to pin 1 (+5V SUPPLY). Voltages applied to DISPLAY ENABLE must never be greater than +5V SUPPLY.
6. Gain Adjust: There is a gain-adjust potentiometer on the back of each meter. It has approximately ±50 counts (±2.5%) range of adjustment. Since these devices essentially have no zero/offset errors, a gain adjustment is effectively an overall accuracy adjustment. Though they may be performed at any point (except zero), accuracy adjustments are most effectiv e when performed with higher level input signals. The circuit shown in Figure 10 provides ±10% range of adjustment.
7. Soldering Methods: All models in the DMS-20PC Series easily withstand most common wave soldering operations. We recommend, however, that you evaluate the effects your particular soldering techniques may have on the meter’s plastic case and high-precision electrical performance. We recommend the use of water-soluble solders and thorough cleaning procedures.
1
12
3
+5V SUP
(–) IN LO
5V RET
DATEL
UPA-5/500
120 VAC
11
(+) IN HI
6
DP1
+
AC to DC Converte r
V
IN
DMS-20PC-1
7
REF OUT
REF IN
8
2
DISPLAY ENABLE
Page 4
4
DMS-20PC
3½ DIGIT, LED DISPLAY DIGITAL PANEL VOLTMETERS
Figure 3. Differential Input Configuration
Figure 6. Floating Input Measurements
(Alternate Configuration)
RShunt = R1 = VFsr /IFsr
Where: VFsr = Full scale reading (in Volts)
I
Fsr = Relative full scale current (in Amps)
R2
R1 + R2
x VIN = Reading
50k
< R1 + R2 < 10M
Figure 4. Input Attenuation Circuit
Figure 5. Floating Input Measurements
Applications
to (–) INPUT LO (pin 12) provides the reference point for the meters input.
A "floating" input is a signal that has no galvanic connection to the meter's power supply. In the figures below, the 1.5V battery illustrates a true floating input.
5. Process Control (4-to-20mA) Measurements: In many common process-control applications, a 4-to-20mA current loop is used to transmit information. Because DMS-20PC meters have such high input impedance, a simple shunt resistor across the meter's input can be used to convert the loop current to a voltage. See Figure 7. The value of the shunt resistor is a function of the scaling requirements of the particular application and can be calculated using the following equation:
4. Floating Signal Source Measurements: Floating signals can be measured using the circuits shown in Figures 5 and 6. Connecting pin 10 (ANALOG COMMON) or pin 3 (5V RETURN)
3. Engineering Scaling: For measuring voltages greater than the full scale input range of a given meter, the input signal must be attenuated. A simple voltage divider (similar to that shown in Figure 4) will scale the input to within the range of the selected meter. R1 and R2 should be precision, ±1%, metal-film resistors with absolute TCR's less than 50ppm/°C . See Ap Note 4 for more information on engineering scaling.
2. Differential Input Configurations: Differential measurements can be made with all DMS-20PC meters. Figure 3, though not a practical real-world application, uses a voltage divider to demonstrate the concept of a differential input signal. Be careful not to exceed the ±2V common mode voltage limitation for 5V­powered meters.
1
12
3
+5V SUP
(–) IN LO
5V RET
DATEL
UPA-5/500
120 VAC
11
(+) IN HI
6
AC to DC Converte r
DMS-20PC-1
R2
R1
R3
1k
1k
1k
8
7
REF IN
DP1
REF OUT
2
DISPLAY ENABLE
DMS-20PC-1
R2
11
12
(+) IN HI
(–) IN LO
V
IN
R1
+
1
3
+5V SUP 5V RET
DATEL
UPA-5/500
120 VAC
AC to DC Converter
8
7
REF OUT
REF IN
2
DISPLAY ENABLE
1
3
+5V SUP
DATEL
UPA-5/500
120 VAC
6
DP1
AC to DC Converter
DMS-20PC-1
12
(–) IN LO
11
(+) IN HI
1.5V
CELL
+
8
7
REF OUT
REF IN
2
DISPLAY ENABLE
5V RET
DMS-20PC-1
12
(–) IN LO
10
ANA COMM
11
(+) IN HI
1.5V
C
ELL
+
8
7
REF OUT
REF IN
1
3
+5V SUP
DATEL
UPA-5/500
120 VAC
6
DP1
AC to DC Converte r
2
DISPLAY ENABLE
5V RET
Page 5
5
Applications
3½ DIGIT, LED DISPLAY DIGITAL PANEL VOLTMETERS
DMS-20PC
Figure 8. 4.5V-18V Power Supply Monitor
Figure 10. External Gain Adjustment
Figure 7. 4-to-20mA Current Loop Operation
To calibrate the circuit of Figure 7, perform the following:
1. With 4mA applied, adjust the 50kΩ potentiometer (R2) to display a reading of "000" (assuming that is the desired reading).
2. With 20mA applied, adjust the gain-adjust potentiometer on the back of the meter to display a reading of "1000". For different full scale readings, alter the value of R
Shunt accordingly.
Figure 9. DC Ammeter Circuit
The LM-2931 was chosen because it has the following on-chip protection features: reverse polarity, short circuit and thermal runaway. When using other, higher-power, DMS-20PC models with three-terminal regulators, be sure to consult the regulator manufacturer's data sheet to ensure the regulator is being utilized safely and correctly.
7. Digital Ammeter: Digital ammeters are finding ever-increasing usage because analog-style ammeters (moving-vane types) now cost roughly the same as their digital counterparts. Additionally, analog ammeters are not nearly as rugged as modern digital panel voltmeters. Figure 9 illustrates a typical ammeter application. The circuit uses a ±200mV input meter the preferred range for most ammeters to measure the voltage developed across a 0.1
current shunt. The circuit shown represents a basic ammeter connection diagram. A detailed application note describing digital dc ammeters is included in DATEL's new Digital Panel Meter Databook.
8. External Gain Adjustment: Connect REFERENCE OUT (pin 8) to REFERENCE IN (pin 7) for normal, factory calibrated, operation. Use the circuit shown in Figure 10 for applications needing external gain adjustment. Calibration is performed with a precise, near-full-scale, input voltage.
6. Power Suppl y Monitoring: One of the most common digital panel meter applications involves monitoring the output voltage of the system power supply often this supply also powers the meter itself. The low-power, red LED DMS-20PC-2-RL can be configured to allow power supply monitoring over the range of
4.5-18Vdc. The circuit in Figure 8 uses a low-drop-out, three­terminal regulator (LM-2931Z-5, available from National Semiconductor) to provide regulated 5V-power to the meter.
Example: For a meter with a 2V full scale input (1.999 full scale reading) and a desired display reading of "1000" (with an input of 20mA), V
Fsr = 1.000 Volts
R
Shunt = 1.000V/(0.020 – 0.004)A
RShunt = 1.000V/0.016A = 62.5 Ohms
13
+5V SUP 5V RET
DATEL
UPA-5/500
120 VAC
AC to DC Converte r
DMS-20PC-1
12
(–) IN LO
10
ANA COMM
11
(+) IN HI
R1
+
4-20mA
50k
R2
8
7
REF OUT
REF IN
2
DISPLAY ENABLE
5
7
8
+
DMS-20PC-2-RL
12
11
1
4.5 - 18Vdc
LM2931Z-5
GND
IN
OUT
+5V SUP
3
DP2
REF
IN
REF
OUT
(–) IN LO
5V RET
2
DISP EN
(+) IN HI
22µF
10V
+
6
3
+
DMS-20PC-0
11
0.150V
1
1.5 Amp (Load Current)
5Vdc
7
8
+5V SUP
5V RET
DP1
(+) IN HI
REF OU
T
REF IN
2
DISP EN
0.1
W
R
Shunt
Load
(3.3 )
12
(–) IN LO
W
12
VOLTAGE
CALIBRATOR
OUT
10
(+) IN HI
(–) IN LO
ANA
COMM
= 10 to 20 Turns
7
REF
IN
11
732, 1%
8.06k, 1%
5V RET
Connections
for ±2V, ±20V
and ±200V models
Connections
for ±200mV
models
COM
17.4k, 1%
2k
24.3k, 1%
3
12
DMS-20PC-1
8
NC
200
+5V IN
1
1
1
1
Page 6
DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 Internet: www.datel.com Email: sales@datel.com Data sheet fax back: (508) 261-2857
DATEL (UK) LTD. Tadley, England Tel: (01256)-880444 DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 01-34-60-01-01 DATEL GmbH München, Germany Tel: 89-544334-0 DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-354-2025
DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL, Inc. trademark.
®®
ISO 9001
ISO 9001
REGISTERED
DS-0271B 1/98
DMS-20PC
3½ DIGIT, LED DISPLAY DIGITAL PANEL VOLTMETERS
MADE IN USA
DMS-20PC-X-XX
FRONT VIEW
DP1 DP2 DP3
PIN #1
IDENTIFIER
+5V SUPPLY
DISPLAY ENABLE
5V RETURN
DP3 DP2 DP1
1 2 3 4 5 6
(–) INPUT LO (+) INPUT HI ANALOG COMMON DISPLAY TEST/HOLD REFERENCE OUT REFERENCE IN
12 11 10
9 8 7
0.80
(20.3)
0.15 (3.8) TYP.
0.50
(12.7)
0.10 (2.5)
TYP.
0.040 (1.02)
0.040 (1.02)
1.10
(27.9)
0.10 (2.5) TYP.
0.25 (6.4) TYP.
0.475 (12.07)
0.040
(1.02)
1.30
(33.0)
1.38
(35.1)
0.88
(22.4)
®®
0.170 (4.32)
0.150 (3.81)
PIN 1
0.125 (3.175) DIAMETER (USE ONLY WHEN PC BOARD MOUNTING)
CALIBRATION POTENTIOMETER HOLE LOCATION
Mechanical Specifications
MECHANICAL DIMENSIONS: Inches (mm) TOLERANCES: 2 PL DEC ±0.02 (±0.51)
3 PL DEC ±0.010 (±0.254) LEAD DIMENSIONS: 0.025 (0.635) x 0.025 (0.635) NOMINAL RECOMMENDED PC BOARD FINISHED HOLE DIAMETER:
0.042 ±0.003 (1.067 ±0.076)
#2-56 INSERT
0.156 (3.96) DEEP
FRONT VIEW
1.280
(32.51)
0.187
(4.75)
OPTIONAL BEZEL (DMS-BZL3 and DMS-BZL4)
RECOMMENDED DRILL AND PANEL CUTOUT DIMENSIONS
1.826 (46.38)
0.838
(21.29)
1.336 (33.93)
1.626 (41.30)
1.07
(27.18)
INTERNAL CORNER RADII:
0.032 (0.81) MAX.
0.145 (3.68)
0.093 (2.362) DIAMETER (4 REQUIRED) ONLY WHEN USING OPTIONAL BEZEL ASSEMBLY
0.116
(2.95)
BEZEL INSTALLATION


RETAINING CLIP INSTALLATION

Loading...