Datasheet DMF-50961NF-SFW Datasheet (OPTREX)

Page 1
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 1/18
OPTREX
Type No.
*******
Mar 8, 1999
First Edition
Quality Assurance Div.
Production Div.
Checked by
Checked by
Approved by
Production Div.
Design Engineering Div.
Prepared by
LCD Module Specification
DMF-50961NF-SFW
DMF-50961NF-SFWDMF-50961NF-SFW
DMF-50961NF-SFW
Table of Contents
1. General Specifications .............................................................................2
2. Electrical Specifications...........................................................................3
3. Optical Specifications..............................................................................8
4. I/O Terminal...........................................................................................10
5. Test..........................................................................................................12
6. Appearance Standards............................................................................13
7. Code System of Production Lot ..........................................................16
8. Type Number..........................................................................................16
9. Applying Precautions .............................................................................16
10. Precautions Relating Product Handling................................................17
11. Warranty..................................................................................................18
Revision History
Rev. Date Page Comment
Page 2
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 2/18
OPTREX
1.General Specifications
Operating Temp.
min. 0℃ ~ max. 50℃
Storage Temp.
min. -20℃ ~ max. 60℃
Dot Pixels
640×480 (H) dots
Dot Size
0.21 (W) × 0.21 (H) mm
Dot Pitch
0.23 (W) × 0.23 (H) mm
Viewing Area
153.0 (W) × 115.4 (H) mm
Outline Dimensions
201.0
*
(W) × 141.0 (H) × 6.5 max. (D) mm
* Without CFL Cable and mounting holes.
W eight
230g max.
LCD Type
NTD-12708
(F-STN / Black
&White-mode / Transflective )
Viewing Angle
6:00
Data Transfer
4-bit parallel data transfer × 2
Backlight
Cold Cathode Fluorescent Lamp (CFL) × 1
Drawings
Dimensional Outline UE-300170A
Page 3
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 3/18
OPTREX
2.Electrical Specifications
2.1.Absolute Maximum Ratings
V
SS
=0V
Parameter Symbol Conditions Min. Max. Units
Supply Voltage
(Logic)
VCC-VSS
-0.3 7.0 V
Supply Voltage
(LCD Drive)
VHH-VSS
-0.3 32.0 V
Input Voltage VI
-0.3 VCC+0.3 V
2.2.DC Characteristics
Ta=25℃, V
SS
=0V
Parameter Symbol Conditions Min. Typ. Max. Units
Supply Voltage
(Logic)
VCC-VSS
2.5 - 5.5 V
Supply Voltage
(LCD Drive)
VHH-VSS Shown in 3.1 V
High Level
Input Voltage
VIH VCC=2.5~5.5V 0.8×VCC
V
CC
V
Low Level
Input Voltage
VIL VCC=2.5~5.5V 0 - 0.2×VCC V
Supply Current
ICC VCC-VSS=5.0V
2.0 5.0 mA
I
HH
VHH-VSS=21.8V
7.0 20.0 mA
Page 4
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 4/18
OPTREX
2.3.AC Characteristics
V
CC
=2.5~5.5V
Parameter Symbol Min. Max. Units
Clock Pulse Cycle Time
t
WCK
152 - ns
Clock Pulse Hi gh Level Width
t
WCKH
65 - ns
Clock Pulse Low Level Width
t
WCKL
65 - ns
Latch Pulse High Level Width
t
WLPH
65 - ns
CP→LP Rise Time
t
LD
0 - ns
CP→LP Fall Time
t
SL
65 - ns
LP→CP Rise Time
t
LS
65 - ns
LP→CP Fall Time
t
LH
65 - ns
Clock Pulse Rise/Fall Time
t
r, tf 50 ns
Data Setup Time
t
DS
50 - ns
Data Hold Time
t
DH
40 - ns
DISPOFF Low Level Width
t
WDL
1.2 -
μ
s
DISPOFF Cancellation Time
t
SD
100 - ns
t
WDL
t
SD
t
r
t
f
t
DH
t
DS
t
WCKL
t
LH
t
SL
CP
t
LD
t
LS
LP
DISPOFF
D0~D3
t
WLPH
TOP DATALAST DATA
t
WCK
t
WCKH
Page 5
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 5/18
OPTREX
2.4.Timing Chart
2.5.Comparison of Display and Data
T=0.0595ms typ.
240×T
FLM
reduction
reduction
LP
FLM
DU3
DU0
CP
LP
#1 DATA
SEGSEG SEGSEG SEGSEG SEGSEG
640636 84640636 84
637
633
5
1
637
633
5
1
DL3
DL0
#241 DATA
SEGSEG SEGSEG SEGSEG SEGSEG
12801276 648644 12801276 648644
1277
1273
645
641
1277
1273
645
641
SEG1 SEG640
#241
#1
#240
#480
DU2DU3
DU0~DU3
DL0~DL3
SEG641 SEG1280
DU0DU1 DU0DU1
DL2DL3 DL0DL1 DL0DL1
Page 6
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 6/18
OPTREX
2.6.Power Supply ON/OFF Sequence
2.6.1.ON Sequence
2.6.2.OFF Sequence
Please maintain the above sequence when turning on and off the power supply of the module. If DISPOFF is supplied to the module
w
hile internal alternate signal for LCD driving (M) is unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module.
VSS
VCC
VSS
VSS
VCC
VSS
VCC
DISPOFF
VHH
VCC
0≦t
0≦t
SIGNAL
SIGNAL
LEVEL
VHH
0≦t
VSS
VCC
VSS
VSS
VCC
VSS
VCC
DISPOFF
VHH
VCC
0≦t
0≦t
SIGNAL
SIGNAL
LEVEL
VHH
0≦t
Page 7
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 7/18
OPTREX
2.7.Lighting Specifications
Ta=25℃
Parameter Symbol Conditions Min. Typ. Max. Units Notes
Lamp Voltage VL
315 - Vrms 1
Lamp Current IL
4.5 5.0 5.5 mArms 2
Starting Voltage VS
420 -
Vrms 3 Surface Luminance L IL=5.0mA 40 50 - cd/㎡ 4 Average Life TAL I
L
=5.0mA 10000 -
hrs 5
Note 1 : The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for
3 minutes .
Note 2 : The current ( r.m.s. ) to flow through the lamp with the electric discharge. It i s mea s ured after
lighting for 3 minutes . Note 3 : The voltage at starting the electric discharge when the voltage is increased gradually from 0V. Note 4 : Surface Luminance is specified by the initial data of luminance measured at the center of display
surface after 20 minutes power on. ( All ON pattern ) Note 5 : CFL life is defined as the time for which the initial luminance is attenuated by 50% of the
luminance value. Average Life representes the time elapsed at the point of time when the residual
ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life
mentioned above.
V
N
I
CFL Testing Circuit
L
F
C
VS VL
IL
Page 8
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 8/18
OPTREX
3.Optical Specifications
3.1.LCD Driving Voltage
Parameter Symbol Conditions Min. Typ. Max. Units
Recommended Ta= 0℃
24.8 V
LCD Driving Voltage VHH-VSS Ta=25℃ 20.3 21.8 23.3 V
Note 1 Ta=50℃ 18.9 -
V
Note 1 : Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of
minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range.
3.2.Optical Characteristics
Ta=25℃, 1/240 Duty, 1/14 Bias, V
D
=21.8V (Note 4), θ= 0゚, φ=-゚
Parameter Symbol Conditions Min. Typ. Max. Units
Contrast Ratio Note 1 CR
θ
= 0゚, φ=-゚
6 - Viewing Angle Shown in 3.3 Response Rise Note 2 TON
180 270 ms
Time Decay Note 3 T
OFF
220 330 ms
Note 1 : Contrast ratio is definded as follows.
CR = L
ON
/ L
OFF
L
ON
: Luminance of the ON segments
L
OFF
: Luminance of the OFF segments
Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON
signal is applied.
Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF
signal is applied.
Note 4 : Definition of Driving Voltage V
D
Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage V
D
is definded
as the voltage V
O-P
when the contrast ratio (CR=LON / L
OFF
) is at its maximum.
V
O-P
1 /
f
F
(
B-2
)
×
V
O-P
/ B
1 /
(
f
F
×
A
)
OFF SIGNAL
ON SIGNAL
Page 9
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 9/18
OPTREX
3.3.Definition of Viewing Angle and Optimum Viewing Area
Point ● shows the point where contrast ratio is measured. : θ= 0゚, φ=-゚
Driving condition : 1/240 Duty, 1/14 Bias, V
D
=21.8V,
f
F
=70Hz
Area shows typ. CR≧2
3.4.System Block Diagram
0
90
180
270
θ
φ
270
135
315
225
45
180
90
θ
= 0 ゚)
φ
10 20 30 40 50
φ
Halogen bulb
Computer
Rotation Table (θ,φ)
Temperature Chamber
LCD
Optical Fiber
Waveform Generator
Control Unit &
#1980A WB
Photometer
θ
Page 10
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 10/18
OPTREX
4.I/O Terminal
4.1.Pin Assignment
CN1
No. Symbol Level Function
1
FLM H / L First Line Marker
2
LP H / L Data Latch Signal
3
CP H / L Clock Signal for Shifting Data
4
DISPOFF H / L Display Control Signal H : Display on L : Display off
5
V
CC
Power Supply for Logic
6
V
SS
Power Supply (0V, GND)
7
V
HH
Power Supply for LCD Drive
8
DU0 H / L Display Upper Data
9
DU1 H / L Display Upper Data
10
DU2 H / L Display Upper Data
11
DU3 H / L Display Upper Data
12
DL0 H / L Display Lower Data
13
DL1 H / L Display Lower Data
14
DL2 H / L Display Lower Data
15
DL3 H / L Display Lower Data
CN2
No. Symbol Level Function
1 CFL2 (GND) - Power Supply for CFL (GND) 2 NC - Non-connection 3 NC - Non-connection 4 CFL1 (HOT) - Power Supply for CFL (HOT)
4.2.Example of Power Supply
It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence.
MODULE
VCC
VHH
VSS
VCC (+Voltage)
VHH (+Voltage)
R1+R2+VR=1020KΩ
VSS (0V)
R2
R1
VR
Tr
Page 11
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 11/18
OPTREX
4.3.Block Diagram
CFL2(GND)
CFL1(HOT)
VHH
VSS
VCC
DU0~DU3
FLM
LP
DISPOFF
CP
or
equivalent
LH1561 × 3
M Cir.
M
Common Driver
or
equivalent
LH1542 × 8
Segment Driver
L C D P
640
240
4
640 × 480 dots
To LSI Logic
CFL Backlight
or
equivalent
LH1542 × 8
Segment Driver
640
240
4
Bias Circuit To LSI
or
equivalent
LH1561 × 3
Common Driver
DL0~DL3
Page 12
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 12/18
OPTREX
5.Test
No change on display and in operation under the following test condition.
No. Parameter Conditions Notes
1 High Temperature Operating 50℃±2℃, 96hrs (operation state) 2 Low Temperature Operating 0℃±2℃, 96hrs (operation state) 3 3 High Temperature Storage 60℃±2℃, 96hrs 4 4 Low Temperature Storage -20
℃±2℃
, 96hrs 3, 4 5 Damp Proof Test 40℃±2℃, 90~95%RH, 96hrs 3, 4 6 Vibration Test Total fixed amplitude : 1.5mm 5
Vibration Frequency : 10~55Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes
7 Shock Test To be measured after dropping from 60cm high on
the concrete surface in packing state.
Note 1 : Unless otherwise specified, tests will be conducted under the following condition.
Temperature : 20±5℃
Humidity : 65±5% Note 2 : Unless otherwise specified, tests will be not conducted under functioning state. Note 3 : No dew condensation to be observed. Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity
after removed from the test chamber.
Note 5 : Vibration test will be conducted to the product itself without putting it in a container.
E
A
G
D
C
F
60cm
Con crete Surface
Dropping method corner dropping
E,F,G face : once
B,C,D edge : once
A corner : once
Face dropping
Edge dropping
B
Page 13
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 13/18
OPTREX
6.Appearance Standards
6.1.Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.
The distance between the eyes and the sample shall be more than 30cm.
All directions for inspecting the sample should be within 45゚against perpendicular line.
6.2.Definition of applicable Zones
A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts
A Zone + B Zone = Validity viewing area
45
X
A Zone B Zone
C Zone
C Zone
X=151.0mm Y=113.4mm
Bezel Flame
Page 14
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 14/18
OPTREX
6.3.Standards
No. Parameter Criteria
1 Black and (1) Round Shape White Spots, Zone Acceptable Number Foreign Substances Dimension (mm) A B C D ≦0.1 * * *
0.1
D ≦0.2 3 5 *
0.2
D ≦0.25 2 3 *
0.25< D ≦0.3 0 1 *
0.3
D 0 0 * D = ( Long + Short ) / 2 * : Disregard (2) Line Shape Zone Acceptable Number X (mm) Y (mm) A B C - 0.03≧W * * *
2.0≧L 0.05≧W 3 3 *
1.0≧L 0.1 ≧W 3 3 * - 0.1 <W In the same way (1) X : Length Y : Width * : Disregard Total defects shall not exceed 5.
2 Air Bubbles (between glass Zone Acceptable Number & polarizer ) Dimension (mm) A B C D ≦ 0.3 * * *
0.3
D ≦ 0.4 3 * *
0.4
D ≦ 0.6 2 3 *
0.6
D 0 0 * * : Disregard Total defects shall not exceed 3.
Page 15
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 15/18
OPTREX
No. Parameter Criteria
3 The Shape of Dot (1) Dot Shape (with Dent)
As per the sketch of left hand.
(2) Dot Shape (with Projection)
Should not be connected to next dot.
(3) Pin Hole
(X+Y) / 2≦0.2mm (Less than 0.1mm is no counted.)
(4) Deformation
(X+Y) / 2≦0.2mm
Total acceptable number : 1/dot, 5/cell (Defect number of (4) : 1pc.)
4 Polarizer Scratches Not to be conspicuous defects. 5 Polarizer Dirts If the stains are removed easily from LCDP surface, the module is not
defective.
6 Complex Foreign Black spots, line shaped foreign substances or air bubbles between
Substance Defects glass & polarizer should be 5pcs maximum in total.
7 Distance between D≦0.2 : 20mm or more Different Foreign 0.2<D : 40mm or more Substance Defects
0.15
Y
X
X
Y
Page 16
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 16/18
OPTREX
7. Code System of Production Lot
The production lot of module is specified as follows.
□ □ □ □
Factory Number (Numeral)
Factory Code (Alphabet)
Production Week (1~5)
Producti on Month (1~9, X, Y, Z)
Production Year (Lower 2 digits)
8.Type Number
The type number of module is specified on the back of module as follows.
DMF-50961NF-SFW
Stamp or Label
9.Applying Precautions
Please contact us when questions and/or new problems not specified in this specifications arise.
Page 17
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 17/18
OPTREX
10.Precautions Relating Product Handling
The Following precautions will guide you in handling our product correctly.
1) Liquid crystal display devices
The liquid crystal display device panel used in the liquid crystal display module is made of plate
glass. Avoid any strong mechanical shock. Should the glass break handle it with care.
The polarizer adhering to the surface of the LCD is made of a soft material.
Guard against scratching it.
2) Care of the liquid crystal display module against static electricity discharge.
When working with the module, be sure to ground your body and any electrical equipment you may be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock.
Avoid t he use of work clothing made of synthetic fibers . We recommend cotton clothing or other conductivity-treated fibers.
Slowly and carefully remove the protective film from the LCD module, since this operation can generate static electricity.
3) When the LCD module alone must be stored for long periods of time:
Protect the modules from high temperature and humidity.
Keep the modules out of direct sunlight or direct exposure to ultraviolet rays.
Protect the modules from excessive external forces.
4) Use the module with a power supply that is equipped with an overcurrent protector circuit, since the module is not provided with this protective feature.
5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap.
6) Conduc1tivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity.
7) For models which use CFL:
High voltage of 1000V or greater is applied to the CFL cable connector area. Care should be taken not to touch connection areas to avoid burns.
Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn.
The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life.
Page 18
DMF-50961NF-SFW (AB) No.99-0053 OPTREX CORPORATION Page 18/18
OPTREX
8) For models which use touch panels:
Do not stack up modules since they can be damaged by components on neighboring modules.
Do not place heavy objects on top of the product. This could cause glass breakage.
9) For models which use COG,TAB,or COF:
The mechanical strength of the product is low since the IC chip faces out unprotected from the rear. Be sure to protect the rear of the IC chip from external forces.
Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact.
10) Models which use flexible cable, heat seal, or TAB:
In order to maintain reliability, do not touch or hold by the connector area.
Avoid any bending, pulling, or other excessive force, which can result in broken connections.
11.Warranty
This product has been manufactured to your company’s specifications as a part for use in your company’s general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement.
We cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery.
We cannot accept responsibility for any defect, which may arise after the application of strong external force to the product.
We cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your company’s acceptance inspection procedures.
When the product is in CFL models, CFL service life and brightness will vary according to the performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise.
We cannot accept responsibility for industrial property, which may arise through the use of your product, with exception to those issues relating directly to the structure or method of manufacturing of our product.
Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later.
Loading...