Datasheet DMF-50174ZNB-FW Datasheet (OPTREX)

Page 1

LCD Module Specification

First Edition
Apr 25, 2000
Final Revision
*******
Approved by
Checked by
Checked by
Production Div.
Design Engineering Div.
Type No.
DMF-50174ZNB-FW
DMF-50174ZNB-FW
DMF-50174ZNB-FWDMF-50174ZNB-FW
Table of Contents
Prepared by
1. General Specifications .............................................................................2
2. Electrical Specifications...........................................................................3
3. Optical Specifications..............................................................................8
4. I/O Terminal...........................................................................................10
5. Test..........................................................................................................12
6. Appearance Standards............................................................................13
7. Code System of Production Lot ..........................................................16
8. Type Number..........................................................................................16
9. Applying Precautions .............................................................................16
10. Precautions Relating Product Handling................................................17
11. Warranty..................................................................................................18
Revision History
Rev. Date Page Comment
Production Div.
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 1/18
OPTREX
Page 2

1.General Specifications

Operating Temp.
Storage Temp.
Dot Pixels
Dot Size
Dot Pitch
Viewing Area
Outline Dimensions
W eight
LCD Type
Viewing Angle
Data Transfer
Backlight
Drawings
min. 0℃ ~ max. 50℃
min. -20℃ ~ max. 60℃
320 (W) × 240 (H) dots
0.33 (W) × 0.33 (H) mm
0.36 (W) × 0.36 (H) mm
122.0 (W) × 92.0 (H) mm
*
174.0
(W) × 112.0 (H) × 14.0 max. (D) mm
* Without CFL Cable
300g max.
NTD-11437
( STN / Blue-mode / Transmissive )
6:00
4-bit parallel data transfer
Cold Cathode Fluorescent Lamp (CFL) × 1
Dimensional Outline UE-20762A
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 2/18
OPTREX
Page 3

2.Electrical Specifications

2.1.Absolute Maximum Ratings
Parameter Symbol Conditions Min. Max. Units
=0V
V
SS
Supply Voltage
(Logic)
Supply Voltage
(LCD Drive)
Input Voltage VI
2.2.DC Characteristics
Parameter Symbol Conditions Min. Typ. Max. Units
Supply Voltage
(Logic)
Supply Voltage
(LCD Drive) VCC-V
VCC-VSS
VCC-VEE
VCC-VSS
VCC-VEE
ADJ
-0.3 7.0 V
0 35.0 V
-0.3 VCC+0.3 V
Ta=25℃, V
4.5 - 5.5 V
27.1 - 32.0 V
SS
=0V
Shown in 3.1 V
High Level
VIH VCC=5.0V±10% 0.8×VCC
Input Voltage
Low Level
VIL VCC=5.0V±10% 0 - 0.2×VCC V
Input Voltage
ICC VCC-VSS=5.0V Supply Current I
VCC-V
EE
ADJ
=23.3V
V
6.0 15.0 mA
5.5 10.0 mA
V
CC
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 3/18
OPTREX
Page 4
2.3.AC Characteristics
Parameter Symbol Min. Max. Units
=5.0V±10%
V
CC
CP Frequency Clock Pulse Width Load Pulse Width Data Setup Time Data Hold Time Clock Pulse Setup Time Clock Pulse Hold Time Rise/Fall Time FLM Setup Time FLM Hold Time
f
CP
t
50 - ns
WC
t
63 - ns
WL
t
30 - ns
SETUP
t
30 - ns
HOLD
t
80 - ns
CL
t
0 - ns
LC
t
r, tf
t
100 - ns
FDS
t
100 - ns
FDH
6.0 MHz
Note 1 ns
Note 1:The rise and fall times (tr, tf ) must satisfy the following relationships (①and ②).
t
r, tf
t
r, tf< 50 ns
1 -
2fCP
t
WC
LOAD
t
t
r
WL
t
CL
t
f
t
LC
CP
t
WC
t
t
r
f
t
SETUP
D0D3
t
FDS
t
FDH
FLM
This module contain these capacitors. Please be careful about timing characteristics.
FLM
1000pF
LP
M
VSS
470pF
t
WC
t
HOLD
1000pF
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 4/18
OPTREX
Page 5
2.4.Timing Chart
LP
CP
D0
D3
FLM
LP
(Reduction)
FLM
(Reduction)
M
313
SEGSEG SEGSEG SEGSEG SEGSEG
317
320316 84320316 84
1
2.5.Comparison of Display and Data
SEG1 SEG320
#1
#240
D2D3
T=0.0595ms typ.
5
240×T
D0D1 D0D1
#1 DATA
TOP VIEW
D0~D3
313
317
1
5
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 5/18
OPTREX
Page 6
2.6.Power Supply ON/OFF Sequence
2.6.1.ON Sequence
SIGNAL
LEVEL VCC
VCC
0≦t
SIGNAL
0≦t
VSS
VCC
VSS
VCC
VADJ
VEE
DISPOFF
0≦t
VSS VADJ VEE
VCC
VSS
2.6.2.OFF Sequence
LEVEL
VCC
SIGNAL
VSS
VCC
VSS
VCC
0≦t
VCC
0≦t
SIGNAL
VSS
VADJ
VEE
VCC
VSS
0≦t
VADJ VEE
DISPOFF
Please maintain the above sequence when turning on and off the power supply of the module. If DISPOFF is supplied to the module
hile internal alternate signal for LCD driving (M) is
w
unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module.
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 6/18
OPTREX
Page 7
2.7.Lighting Specifications
Ta=25℃
Parameter Symbol Conditions Min. Typ. Max. Units Notes Lamp Voltage VL Lamp Current IL Starting Voltage VS
4.0 5.0 6.0 mArms 2
220 - Vrms 1
630 - Vrms 3
Surface Luminance L IL=5.0mA 40 50 - cd/㎡ 4 Average Life TAL I
=5.0mA 10000 15000 - hrs 5
L
Note 1 : The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for
3 minutes .
Note 2 : The current ( r.m.s. ) to flow through the lamp with the electric discharge. It i s mea s ured after
lighting for 3 minutes . Note 3 : The voltage at starting the electric discharge when the voltage is increased gradually from 0V. Note 4 : Surface Luminance is specified by the initial data of luminance measured at the center of display
surface after 20 minutes power on. ( All ON pattern ) Note 5 : CFL life is defined as the time for which the initial luminance is attenuated by 50% of the
luminance value. Average Life representes the time elapsed at the point of time when the residual
ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life
mentioned above.
I N V
VS VL
C
F L
CFL Testing Circuit
IL
Recommended Inverter : S-12561 ( Produced by ELEVAM ) CXA-L10L ( Produced by TDK)
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 7/18
OPTREX
Page 8

3.Optical Specifications

(
)
(
)
3.1.LCD Driving Voltage
Parameter Symbol Conditions Min. Typ. Max. Units
Recommended Ta= 0℃
LCD Driving Voltage VCC-V
Ta=25℃ 21.7 23.3 24.9 V
ADJ
27.1 V
Note 1 Ta=50℃ 19.9 -
Note 1 : Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of
minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range.
3.2.Optical Characteristics
Ta=25℃, 1/240 Duty, 1/14 Bias, V
=23.3V (Note 4), θ= 0゚, φ=-゚
D
Parameter Symbol Conditions Min. Typ. Max. Units
Contrast Ratio Note 1 CR
= 0゚, φ=-゚
θ
4 -
Viewing Angle Shown in 3.3 Response Rise Note 2 TON
Time Decay Note 3 T
OFF
100 200 ms
360 540 ms
Note 1 : Contrast ratio is definded as follows.
CR = L
L
: Luminance of the ON segments
ON
L
: Luminance of the OFF segments
OFF
ON
/ L
OFF
Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON
signal is applied.
Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF
signal is applied.
Note 4 : Definition of Driving Voltage V
V
D=VCC-VADJ-VBE
D
Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage V as the voltage V
when the contrast ratio (CR=LON / L
O-P
) is at its maximum.
OFF
O-P
V
1 /
×
f
F
A
1 /
f
F
B-2
×
ON SIGNAL
OFF SIGNAL
is definded
D
O-P
/ B
V
V
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 8/18
OPTREX
Page 9
3.3.Definition of Viewing Angle and Optimum Viewing Area
Point ● shows the point where contrast ratio is measured. : θ= 0゚, φ=-゚
180
Driving condition : 1/240 Duty, 1/14 Bias, V
90
135
10 20 30 40 50
225
270
Area shows typ. CR≧2
θ
45
315
φ
=23.3V,
D
(φ= 0 ゚)
3.4.System Block Diagram
Temperature Chamber
Photometer
#1980A WB
Computer
Control Unit & Waveform Generator
f
=70Hz
F
180
270
Rotation Table (θ,φ)
φ
θ
θ
90
φ
0
LCD
Optical Fiber
Halogen bulb
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 9/18
OPTREX
Page 10

4.I/O Terminal

4.1.Pin Assignment
CN1,CN2
No. Symbol Level Function
10 11 12 13 14
CN3
FLM H / L First Line Marker
1
LP H / L Data Latch Signal
2
CP H / L Clock Signal for Shifting Data
3
M H / L Alternate Signal for LCD Drive
4
V
5
V
6
V
7
V
8
D0 H / L Display Data
9
ADJ
CC
SS
EE
Voltage Level for LCD Contrast Adjustment
Power Supply for Logic
Power Supply (0V, GND)
Power Supply for LCD Drive
D1 H / L Display Data D2 H / L Display Data D3 H / L Display Data DISPOFF H / L Display Control Signal H : Display on L : Display off NC - Non-connection
No. Symbol Level Function
1 FL HOT - Power Supply for CFL (HOT) 2 NC - Non-connection 3 NC - Non-connection 4 FL GND - Power Supply for CFL (GND)
4.2.Example of Power Supply
It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence.
VCC
MODULE
VADJ
VEE
VCC (+Voltage)
R1
VR
R2
VEE (-Voltage)
VSS VSS (0V)
R1+R2+VR=10~20K
Ω
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 10/18
OPTREX
Page 11
4.3.Block Diagram
FLM
Row Driver
LC79431D × 3
or equivalent
240
L C D P
320 × 240 dots
LP
DISPOFF
M
CP
D0D3
3
3
Column Driver
LC79401D × 4
or equivalent
4
320
M Circuit
VCC
VSS
To LSIBias Circuit
VADJ
VEE
FL HOT
CFL Backlight
FL GND
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 11/18
OPTREX
Page 12

5.Test

No change on display and in operation under the following test condition.
No. Parameter Conditions Notes
1 High Temperature Operating 50℃±2℃, 96hrs (operation state) 2 Low Temperature Operating 0℃±2℃, 96hrs (operation state) 3 3 High Temperature Storage 60℃±2℃, 96hrs 4 4 Low Temperature Storage -20℃±2℃, 96hrs 3, 4 5 Damp Proof Test 40℃±2℃, 90~95%RH, 96hrs 3, 4 6 Vibration Test Total fixed amplitude : 1.5mm 5
Vibration Frequency : 10~55Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes
7 Shock Test To be measured after dropping from 60cm high on
the concrete surface in packing state.
E
B
D
G
A
60cm
Con crete Surface
Note 1 : Unless otherwise specified, tests will be conducted under the following condition.
Temperature : 20±5℃
Humidity : 65±5% Note 2 : Unless otherwise specified, tests will be not conducted under functioning state. Note 3 : No dew condensation to be observed. Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity
after removed from the test chamber.
Note 5 : Vibration test will be conducted to the product itself without putting it in a container.
Dropping method corner dropping
F
C
A corner : once
Edge dropping
B,C,D edge : once
Face dropping
E,F,G face : once
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 12/18
OPTREX
Page 13

6.Appearance Standards

6.1.Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.
The distance between the eyes and the sample shall be more than 30cm.
All directions for inspecting the sample should be within 45゚against perpendicular line.
6.2.Definition of applicable Zones
45
A Zone B Zone
C Zone
Bezel Flame
A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts
A Zone + B Zone = Validity viewing area
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 13/18
OPTREX
Page 14
6.3.Standards
No. Parameter Criteria
1 B lack and (1) Round Shape White Spots, Zone Acceptable Number Foreign Substances Dimension (mm) A B C D ≦0.1 * * *
0.1
0.2
D ≦0.2 3 5 *
D ≦0.25 2 3 *
0.25< D ≦0.3 0 1 *
0.3
D 0 0 *
D = ( Long + Short ) / 2 * : Disregard (2) Line Shape
Zone Acceptable Number X (mm) Y (mm) A B C - 0.03≧W * * *
2.0≧L 0.05≧W 3 3 *
1.0≧L 0.1 ≧W 3 3 * - 0.1 <W In the same way (1) X : Length Y : Width * : Disregard Total defects shall not exceed 5.
2 Air Bubbles (between glass Zone Acceptable Number & polari zer) Dimension (mm) A B C D ≦ 0.3 * * *
0.3
0.4
0.6
D ≦ 0.4 3 * *
D ≦ 0.6 2 3 *
D 0 0 *
* : Disregard Total defects shall not exceed 3.
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 14/18
OPTREX
Page 15
No. Parameter Criteria
3 The Shape of Dot (1) Dot Shape (with Dent)
0.15
As per the sketch of left hand.
(2) Dot Shape (with Projection)
Should not be connected to next dot.
(3) Pin Hole
X
(X+Y) / 2≦0.2mm (Less than 0.1mm is no counted.)
Y
(4) Deformation
(X+Y) / 2≦0.2mm
Y
X
Total acceptable number : 1/dot, 5/cell (Defect number of (4) : 1pc.)
4 Polarizer Scratches Not to be conspicuous defects.
5 Polarizer Dirts If the stains are removed easily from LCDP surface, the module is not defective.
6 Complex Foreign Black spots, line shaped foreign substances or air bubbles between Substance Defects glass & polarizer should be 5pcs maximum in total.
7 Distance between D≦0.2 : 20mm or more Different Foreign 0.2<D : 40mm or more Substance Defects
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 15/18
OPTREX
Page 16

7.Code System of Production Lot

The production lot of module is specified as follows.
□ □ □ □
Production Year (Lower 2 digits)

8.Type Number

The type number of module is specified on the back of module as follows.
DMF-50174

9.Applying Precautions

Please contact us when questions and/or new problems not specified in this specifications arise.
Factory Number (Numeral)
Factory Code (Alphabet)
Production Week (1~5)
Producti on Month (1~9, X, Y, Z)
ZNB-FW
Stamp
Etching or Printing
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 16/18
OPTREX
Page 17

10.Precautions Relating Product Handling

The Following precautions will guide you in handling our product correctly.
1) Liquid crystal display devices
The liquid crystal display device panel used in the liquid crystal display module is made of plate
glass. Avoid any strong mechanical shock. Should the glass break handle it with care.
The polarizer adhering to the surface of the LCD is made of a soft material.
Guard against scratching it.
2) Care of the liquid crystal display module against static electricity discharge.
When working with the module, be sure to ground your body and any electrical equipment you may
be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock.
Avoid t he use of work clothing made of synthetic fibers . We recommend cotton clothing or other
conductivity-treated fibers.
Slowly and carefully remove the protective film from the LCD module, since this operation can
generate static electricity.
3) When the LCD module alone must be stored for long periods of time:
Protect the modules from high temperature and humidity.
Keep the modules out of direct sunlight or direct exposure to ultraviolet rays.
Protect the modules from excessive external forces.
4) Use the module with a power supply that is equipped with an overcurrent protector circuit, since the module is not provided with this protective feature.
5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap.
6) Conduc1tivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity.
7) For models which use CFL:
High voltage of 1000V or greater is applied to the CFL cable connector area.
Care should be taken not to touch connection areas to avoid burns.
Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn.
The use of CFLs for extended periods of time at low temperatures will significantly shorten their
service life.
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 17/18
OPTREX
Page 18
8) For models which use touch panels:
Do not stack up modules since they can be damaged by components on neighboring modules.
Do not place heavy objects on top of the product. This could cause glass breakage.
9) For models which use COG,TAB,or COF:
The mechanical strength of the product is low since the IC chip faces out unprotected from the rear.
Be sure to protect the rear of the IC chip from external forces.
Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical
damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact.
10) Models which use flexible cable, heat seal, or TAB:
In order to maintain reliability, do not touch or hold by the connector area.
Avoid any bending, pulling, or other excessive force, which can result in broken connections.

11.Warranty

This product has been manufactured to your company’s specifications as a part for use in your company’s general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement.
We cannot accept responsibility for any defect, which may arise from additional manufacturing of
the product (including disassembly and reassembly), after product delivery.
We cannot accept responsibility for any defect, which may arise after the application of strong
external force to the product.
We cannot accept responsibility for any defect, which may arise due to the application of static
electricity after the product has passed your company’s acceptance inspection procedures.
When the product is in CFL models, CFL service life and brightness will vary according to the
performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise.
We cannot accept responsibility for intellectual property of a third party, which may arise through the
application of our product to your assembly with exception to those issues relating directly to the structure or method of manufacturing of our product.
Optrex will not be held responsible for any quality guarantee issue for defect products judged as
Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later.
DMF-50174ZNB-FW (AT) No.2000-0166 OPTREX CORPORATION Page 18/18
OPTREX
Loading...