Datasheet D1D12 Specification

Page 1
Series 1-DC
• D1D to D5D series SSRs; MOSFET output
• Ratings from 7A to 40A @ 200 VDC, and from 7A to 10A @ 500 VDC
• DC Control
• Relays are easily paralleled for higher-current applications
• CE Compliant to EN60950-1
Load Voltage 7A 10A 12A 20A 40A
100 VDC D1D07 D1D12 D1D20 D1D40 200 VDC D2D07 D2D12 D2D40 400 VDC D4D07 D4D12 500 VDC D5D07 D5D10
OUTPUT SPECIFICATIONS (1)
Description 7A 12A 20A 40A 7A 12A 40A 7A 12A 7A 10A
Operating Voltage Range 0-100 0-100 0-100 0-100 0-200 0-200 0-200 0-400 0-400 0-500 0-500 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.2 0.3 0.3 0.1 0.3 0.3 0.3 0.3 0.2 0.3 Maximum Load Current (3) [Adc] 7 12 20 40 7 12 40 7 12 7 10 Minimum Load Current [mA] 1 1 1 1 1 1 1 1 1 1 1 Maximum Surge Current [Adc] (10ms) 15 28 42 106 22 27 106 17 36 19 29 Maximum On-State Voltage Drop @ Rated Current [Vdc] 2.0 1.6 2.1 2.1 2.0 2.8 2.1 4.2 4.2 5.7 5.5 Thermal Resistance Junction to Case (Rjc) [°C/W] 2.2 1.34 1.06 0.83 1.5 1.06 0.83 1.06 0.8 1.0 0.8 Maximum On-State Resistance [RDS-ON][Ohms] 0.29 0.13 0.10 0.05 0.29 0.23 0.05 0.6 0.35 0.8 0.55
INPUT SPECIFICATIONS (1)
Description DC Control
Control Voltage Range 3.5-32 VDC Minimum Turn-On Voltage 3.5 VDC Minimum Turn-Off Voltage 1.0 VDC Minimum Input Current @ 5VDC 1.6 mA Maximum Input Current @ 32VDC 28 mA Nominal Input Impedance See Note 4 Maximum Turn-On Time [µsec] 100 Maximum Turn-Off Time [msec] 1.0
GENERAL SPECIFICATIONS
Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz) 2500 VRMS Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output 50 pF Ambient Operating Temperature Range -20 to 80°C Ambient Storage Temperature Range -20 to 125 °C Weight (typical) 3.0 oz (86.5g) Encapsulation Thermally conductive Epoxy Terminals Screws and Saddle Clamps Furnished, Unmounted Recommended Terminal Screw Torque Range: 6-32 Screws - 10 in lbs. 8-32 and 10-32 Screws -20 in. lbs. (Screws dry without grase)
GENERAL NOTES
1) All parameters at 25°C and per section unless otherwise specified.
2) Dielectric strength and insulation resistance are measured between input and output
3) Heat sinking required, for derating curves see page 3.
4) Input circuitry version incorporates active current limiter.
109 Ohm
Page 2
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
Page 3
WIRING DIAGRAM
MAXIMUM SURGE VS DURATION
AGENCY APPROVALS
EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Designed in accordance with the requirements of IEC 62314
UL E116950 (100 Volt Models 1-DC Only )
Rev. 120711
Page 4
Page 5
ANNEX - ENVIROMENTAL INFORMATION
Loading...