• Switches are Designed to withstand Electro-Magnetic Pulse (EMP)
• Functions and Operates from -55°C to +125°C in Military Environments
• Processed and Screened to Mil-STD-883 Specifications
The CT2100-400 is a microprocessor controlled, quad solid state relay that incorporates fully isolated switch
control and built-in test. The hybrid provides 600 Volts isolation between control inputs and switch outputs.
Internal control and status registers provide analog switch function which operates via simple I/O commands.
CIRCUIT TECHNOLOGY
www.aeroflex.com/act1.htm
PRESET/CLEAR1-4
WRITE
INIT
CS
A0
A
1
0-7
8 Bit
DATA
READ
Block Diagram
4
Smart Switch
4
8
Switch
Control
Latch
ON/OFF
and
TRIP
Switch
Status
4
600 Volt
Isolation
ON/OFF
2
&
8
TRIP
1
TRIP
Sense
Smart Switch
2
Smart Switch
3
S1+
1–
S
2+
S
S
2–
3+
S
3–
S
eroflex Circuit
Technology
Smart Switch
4
– SCDCT2100 REV B 10/1/98
4+
S
4–
S
Page 2
DESCRIPTION
The CT2100-400 is a quad solid
state relay. The device has been
designed to provide an interface
which operates as a simple
computer I/O port. The switches
are controlled by a single data
word which the processor writes to
an internal control latch. In
addition to the basic switch
function ON/OFF and Trip flags
provide the operational status of
each of the four switches. These
signals are internally contained in
an 8 bit status register which is
accessible by an I/O read
command. The switches may also
be controlled asynchronously
(without write strobes) by use of
separate initialization pins. These
may also be used for Power-Up
control in a microprocessor based
system.
SWITCH CONTROL
The CT2100-400 has four
independent fully isolated
switches which may be used as
high side or low side drivers. The
isolated design allows the user
to parallel devices or place them
in series as required for the
specific application. Control of
the switch is via I/O write
(Address 0) or asynchronous
control lines. The CT2100-400
has an internal switch control
latch which is updated via
subsystem I/O write as
illustrated in Figure 2. Once the
I/O write is completed the switch
is latched into the OFF or ON
state. The switch may also be
controlled via individual
PRESET and CLEAR lines.
These lines asynchronously
drive the switch control latch
without the need for a write
strobe. The PRESET/CLEAR
inputs are enabled by the
initializepin.
SWITCH STATUS
Each switch in the CT2100-400
is monitored for circuit Trip and
ON/OFF. This data is contained
in a 8 bit status register which is
accessible via an I/O read
(Address0) command. The
timing for the I/O read is shown
in Figure 1. The Trip and
ON/OFF flags are provided to
the system to assess the
operational capability of the
switch versus the status of the
controlled load. The Trip bit is
set high when the switch has
conducted between 1.1 to 3
amps of current based on the
time to trip curve in Figure 3.
The over current DC trip point is
typically 1.3 amps.
Table 1 — Absolute Maximum Ratings
Supply Voltage (VCC) — Pin 20-0.5 to +7.0 Volts DC
Supply Voltage (V
Logic Input Voltage — Pins 2-9, 12-19-0.5 to V
Switch Point Voltage — Pins 39-40, 29-32, 21-22
Storage Temperature Range-65°C to +150 °C
Supply Voltage (VCC) — Pin 20+5.0 VDC ±10%
Supply Voltage (V
Logic Input Maximum Voltage (High) — Pins 2-9, 12-19+3.3 V
Logic Input Minimum Voltage (Low) — Pins 2-9, 12-19+0.8 V
Switch Point Voltage — Pins 39-40, 29-32, 21-2260 VDC
) — Pin 1-.5 to +18 Volts DC
EE
+.5 Volts DC
CC
-600 to +600 Volts (200 ns)
80 Volts DC
Table 2 — Recommended Operating Conditions
) — Pin 1+14.25 to +15.75 VDC
EE
Operating Temperature Range-55°C to +125 °C
Aeroflex Circuit TechnologySCDCT2100 REV B 10/1/98 Plainview NY (516) 694-6700
2
Page 3
Timing Waveforms
SWITCH
CONTROL
DATA
/ CS
WRITE
Parameter
Pulse WidthT
Data DelayT
T
h
READ
STATUS
DATA
T
/ CS
T
Figure 2
VALID
T
su
T
pw
Figure 1
Table 3 — Timing Characteristics
READ CycleWRITE Cycle
Sym
PW
D
MinMaxUnits
100-nsecPulse WidthTPW100-nsec
-50nsecSet-up TimeTS25-nsec
Parameter
SymMinMaxUnits
d
pw
VALID
T
h
Hold TimeT
Parameter
DC Continous Rated CurrentIC-1Amps
DC Trip Current
(For Time to Trip Refer to Figure 3)
On ResistanceR
Output Leakage Current at 80 VDCI
Switch Turn-on TimeT
IsolationV
D
10-nsecHold TimeTH10-nsec
Table 4 — Switch Data
SymMinMaxUnits
I
OT1.11.5Amps
ON-0.6Ohms
L-40µA
SD-2msec
ISO600-Volts
Aeroflex Circuit TechnologySCDCT2100 REV B 10/1/98 Plainview NY (516) 694-6700
3
Page 4
Table 5 — Bus Bit Definition
ADDRESS = 0
BITWRITE CYCLEREAD CYCLE
D0S1 ON/OFF 0 = ONS1 ON/OFF status (Bit = 0)(When switch on)
D1Not UsedS1 TRIP status (Bit = 1)(When short circuit protection active))
D2S2 ON/OFF 0 = ONS2 ON/OFF Status
D3Not UsedS2 TRIP Status
D4S3 ON/OFF 0 = ONS3 ON/OFF Status
D5Not UsedS3 TRIP Status
D6S4 ON/OFF 0 = ONS4 ON/OFF Status
D7Not UsedS4 TRIP Status
ADDRESS = 1 (Wrap Around)
D0 – D7Bit = 1 or 0Whatever was written in the write cycle will be read
ADDRESS = 2
D0X \1
D1XNot Used
D2X0 = Command On (Signal being sent from the control side to Isolation Driver)
D3XNot Used
D4X0 = Command On (Signal being sent from the control side to Isolation Driver)
D5XNot Used
D6X0 = Command On (Signal being sent from the control side to Isolation Driver)
D7XNot Used
\1
X = Don’t care. During a write cycle (Address 2) it shall be considered as if the INIT is enabled.
0 = Command On (Signal being sent from the control side to Isolation Driver)
Table 6 —Built-in Test Status (BIT)
Switch Control
(Closed/OPEN)
101Normal (OFF)
TRIP StatusON/OFF StatusConclusion
000Normal (ON)
011Switch Tripped off due to excessive load current
Note: All other TRIP and ON/OFF status combinations are indicative of switch, BIT or load failures