The CL431 is an adjustable shunt regulat or designed t o act as
an open-loop error amplifier with a 2.5V temperature
compensated reference. Its highly accurate 0.5% bandgap
reference is perfect for applications requiring stability and
accuracy over temp er atur e and life.
Sharp turn-on characteristics and a low temperature
coefficient make the CL431 an excellent replacement for
many zener diode applications, programmable to any value
greater than 2.5V and up to 36V by using two external
resistors. As a combination error amplifier and reference, it
can be used to manage contr ol loops suc h a s s w itchin g p ower
supplies.
The CL431 can be used as a direct replacement for the
standard TL431.
ORDERING INFORMATION
PartPackageTemperature Range
o
CL431LPTO-920 to 105
CL431D8-Pin Plastic SOI C0 to 105
CL431SSOT-890 to 105
C
o
C
o
C
TO-92 (LP)
CATHODE
ANODE
REFERENCE
1G-33
CATHODE
ANODE
ANODE
N/C
SOIC (D)
1
2
3
4
8
REFERENCE
7
ANODE
6
ANODE
5
N/C
1G-34
SOT-89 (S)
CATHODE
ANODE
REFERENCE
1G-35
CALOG IC CORPOR AT ION, 237 Whitney Place, Fremont, California 94539, Telephone: 510-656-2900, FAX: 510-651-3025
Page 2
CL431
CORPORATION
ABSOLUTE MAXIMUM RATINGS
SYMBOLPARAMETERRATINGUNITS
V
KA
I
AK
I
KA
I
REF
P
D
T
J
T
STG
T
L
Exceeding ABSOLUTE MAXIM UM RATINGS may cause perm anen t damage. Extende d operat ion of the device at these or any other conditions
above those indicated in the operational sections of this specification is not recommended as it may adversely affect reliability and performance.
RECOMMENDED CONDITIONS
SYMBOLP ARAMETERRATINGUNIT
V
KA
I
K
Cathode-Anode Reverse Breakdown37V
Anode-Cathode Forward Current1A
Operating Cathode Current250mA
Reference Inp ut Current10mA
Continuou s Power at 25oC
TO-92
8L SOIC
SOT-89
775
750
1000
Junction Temperature150
Storage Temperature–65 to 150
Lead Temperature, Soldering 10 Seconds300
TYPICAL THERMAL RESISTANCE
Cathode VoltageV
to 20V
REF
Cathode Current10mA
PACKAGEθ
TO-92160
SOIC175
SOT-89110
JA
o
C/W80oC/W6.3mW/oC
o
C/W45oC/W5.7mW/oC
o
C/W8oC/W9.1mW/oC
θ
JC
mW
mW
mW
o
C
o
C
o
C
TYPICAL DERATING
FUNCTIONAL BLOCK DIAGRAM
CATHODE (K)
REFERENCE (R)
+
–
2.5V
ANODE (A)
1G-36
CALOG IC CORPOR ATION, 237 Whitney Place, Fremont, California 94539, T elephone: 510-656-2900, FAX: 510-651-3025
Page 3
CL431
CORPORATION
ELECTRICAL CHARACTERISTICS
Electrical Charact eristics are guarant ee d over full junct ion tempe ratu re ran ge (0 to 105oC). Ambient tempera ture must be derated based on
power dissipation and package thermal characteristics. The conditions are: V
SYMBOLPARAMETER
V
REF
TC∆V
∆V
REF
∆V
K
I
REF
∆I
REF
I
K(MIN)
I
K(OFF)
Z
KA
Reference Voltage
with Temp.*0.070.20mV/oC1
REF
Ratio of Change in V
Cathode Voltage
Reference Input Current0.74µA2
I
Temp Deviation0.41.2µA2Over Temp.
REF
Min IK for Regulation0.41mA1
Off State Leakage0.04250nA3V
Dynamic Output Impedance0.150.5Ω1f ≤ 1kHz, IK = 1 to 150mA
REF
to
CL431 (0.5%)
MINTYPMAX
2.4902.5032.515V1T
2.4692.536V1Over Temp.
–2.7–1.0
–2–0.40.310V to 36V
KA
= V
and IK = 10mA unless otherwise stated.
REF
UNIT
TEST
CIRCUIT
mV/V2
TEST CONDITION
= 25oC
A
V
to 10V
REF
= 0V, VKA = 36V
REF
*CALCULAT ING AVERAGE TEMPERATURE COEFFICIENT (TC)
%
ppm
000
0.55000
mV
∆V
REF
∆T
–10
0153045607590105
TEMPERATURE (˚C)
0.07 mV/˚C
0.003 %/˚C
27 ppm/˚C
1G-37
TEST CIRCUITS
V
V
IN
I
REF
V
= V
KA
REF
I
K
IN
R
(V)
REF
R
1
I
REF
2
∆V
(mV)
• TC in mV/oC =
• TC in %/oC =
• TC in ppm/oC =
V
KA
I
K
V
IN
REF
∆T
A
∆V
REF
V
at 25
REF
V
REF
∆T
∆V
REF
at 25oC
∆T
V
I
K(OFF)
o
C
A
KA
x 100
x 10
A
6
1G-38
1G-39
1G-40
TEST CIRCUIT 1TEST CIRCUIT 2TEST CIRCUIT 3
CALOG IC CORPOR ATION, 237 Whitney Place, Fremont, California 94539, T elephone: 510-656-2900, FAX: 510-651-3025
Page 4
CL431
2.54
2.46
–60
1G-44
TEMPERATURE COEFFICIENT AS
A FUNCTION OF TRIM VALUE
–30
2.47
2.48
2.49
2.50
2.51
2.52
2.53
0
306090120
V
REF
– REFERENCE VOLTAGE (V)
– AMBIENT TEMPERATURET
A
V
KA
= V
REF
I
K
= 10mA
V
REF
= 2.503V AT 25˚C
TYPICAL PERFORMANCE CU R VES
CORPORATION
LOW CURRENT OPERATING
900
800
700
600
500
400
300
200
100
– CATHODE CURRENT (µA)
0
K
I
–100
–200
–1.03.0
100
10
1
CHARACTERISTICS
V= V
REFKA
TEMPERATURE RANGE: –55 to 125˚C
125˚C
25˚C
–55˚C
1.002.0
VKA– CATHODE VOLTAGE (V)
OFF STATE LEAKAGE
VKA= 36V
= 0V
V
REF
1G-41
HIGH CURRENT OPERATING
CHARACTERISTICS
VKA= V
REF
TEMPERATURE RANGE: –55 to 125˚C
–23
– CATHODE VOLTAGE (V)V
KA
– CATHODE CURRENT (mA)
I
K
150
125
100
75
50
25
0
–25
–50
–75
–100
210–1
1G-42
CURRENT (nA)
– OFF STATE CATHODEI
0.1
off
Z
0.01
–300 306090120
–60
– AMBIENT TEMPERATURE (˚C)T
A
3.0
R1 = 10kΩ
R2 = ∞
2.5
I
K
2.0
1.5
1.0
CURRENT (µA)
– REFERENCE INPUTI
REF
0.5
0
–60
TA– AMBIENT TEMPERATURE (˚C)
= 10mA
–300 306090120
REFERENCE
INPUT CURRENT
1G-43
1G-45
0
–10
–20
–30
VOLTAGE (mV)
– CHANGE IN REFERENCEV
–40
REF
IK= 10mA
TEMPERATURE RANGE: –55 to 125˚C
–50
030
REFERENCE VOLTAGE
LINE REGULATION
–55˚C
0˚C
25˚C
75˚C
125˚C
3 6 9 12 15 18 21 24 27
– CATHODE VOLTAGE (V)V
KA
1G-46
CALOG IC CORPOR ATION, 237 Whitney Place, Fremont, California 94539, T elephone: 510-656-2900, FAX: 510-651-3025
Page 5
CORPORATION
TYPICAL PERFORMANCE CU R VES (cont in ued)
NOISE VOLTAGE
VKA= V
REF
I
= 10mA
K
= 25˚C
T
A
f – FREQUENCY (Hz)
10k1k100
NOISE VOLTAGE nV/ Hz
70
60
50
40
30
20
10
0
10
100k
1G-47
– DYNAMIC IMPEDANCE (Ω)
KA
Z
LOW FREQUENCY DYNAMIC
0.150
0.125
0.100
0.075
0.050
0.025
0.0
OUTPUT IMPEDANCE
VKA= V
REF
= 1 TO 100mA
I
KA
f ≤ 1kHz
–300 306090120
–60
– FREE AIR TEMPERATURET
A
CL431
1G-48
70
60
50
40
100
1.0
0.1
– DYNAMIC IMPEDANCE (Ω)
KA
Z
0.01
SMALL SIGNAL GAIN
vs FREQUENCY
TA= 25˚ C
= 10mA
I
K
TA= 25˚C
10
1k
DYNAMIC OUTPUT
IMPEDANCE
= 1 TO 100mAI
K
f – FREQUENCY (Hz)
9µF
10M
15k
1G-49
OUT
I
K
230Ω
1M100k10k
GAIN (dB)
– SMALL SIGNAL VOLTAGE
V
A
30
20
10
8.25k
GND
1H-01
0
1k
100k10k
f – FREQUENCY (Hz)
1M
10M
1G-50
CALOG IC CORPOR ATION, 237 Whitney Place, Fremont, California 94539, T elephone: 510-656-2900, FAX: 510-651-3025
Page 6
CL431
1H-03
GND
OUT
220
Ω
INPUT
MONITOR
50
Ω
fP= 100kHz
TYPICAL PERFORMANCE CU R VES (cont in ued)
CORPORATION
6
PULSE RESPONSE
INPUT
5
4
3
OUTPUT
2
1
0
INPUT AND OUTPUT VOLTAGES (V)
–1
0
t – TIME (µs)
STABILITY BOUNDARY
100
A: VKA= V
B: VKA= 5V AT IK= 10mA
90
C: V
80
D: V
70
60
50
40
30
20
– CATHODE CURRENT (mA)
K
I
10
TA= 25˚C
0
1010
CONDITIONS
REF
= 10V AT IK= 10mA
KA
= 15V AT IK= 10mA
KA
STABILITY
REGION
– LOAD CAPACITANCE (pF)C
L
A
B
D
121234567891011
1H-02
150Ω
I
K
C
C
L
10k
1H-05
7
6543210
101010101010
1H-04
CALOG IC CORPOR ATION, 237 Whitney Place, Fremont, California 94539, T elephone: 510-656-2900, FAX: 510-651-3025
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.