Datasheet CD241202 Datasheet (POWEREX)

Page 1
Dimension Inches Millimeters
A 2.106 53 B 1.705±0.008 43.3±0.2 C 1.437 36.5 D 1.299 33 E 0.925 23.5 F 0.866 22 G 0.551 14 H 0.354 9 J 0.315 8 K 0.276 7
L 0.236 R R6 M 0.209 5.3 N 0.209 Dia. Dia. 5.3
P 0.177 4.5 Q 0.138 3.5 R M4 Metr ic M4
Description:
Powerex Fast Recovery Dual Diode Modules are designed for use in applications requiring fast switching.The modules are isolat­ed for easy mounting with other components on common heatsinks.
Features:
M Isolated Mounting M Planar Chips
Applications:
M Free Wheeling
Ordering Information:
Select the complete eight digit module part number you desire from the table below. Example: CD241202 is a 1200 Volt, 20 Ampere Fast Recovery Dual Diode Module.
Voltage Current Rating
Type Volts (x100) Amperes (x10)
CD24 06 02
12
D-25
Powerex,Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Fast Recovery Dual Diode Modules
20 Amperes/600-1200 Volts
CD240602 CD241202
Outline Drawing
CD240602, CD241202 Fast Recovery Dual Diode Modules
20 Amperes/600-1200 Volts
A B
J
J
J
(3 TYP.)
D
M
(2 TYP.)
QQ
C
L
K
F
P
H
N - DIA.
R - M4 THD
(3 TYP.)
H
G
E
Page 2
D-26
Powerex,Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272
CD240602, CD241202 Fast Recovery Dual Diode Modules
20 Amperes/600-1200 Volts
Absolute Maximum Ratings
Characteristics Symbol CD240602 CD241202 Units
Peak Reverse Blocking Voltage V
RRM
600 1200 Volts
Transient Peak Forward Blocking Voltage (Non-Repetitive), t < 5ms V
RSM
720 1350 Volts
DC Reverse Blocking Voltage V
R(DC)
480 960 Volts
DC Output Current, TC= 114°C I
F(DC)
20 20 Amperes
Peak One-Cycle Surge (Non-Repetitive) On-State Current (60Hz) I
FSM
400 400 Amperes
Peak One-Cycle Surge (Non-Repetitive) On-State Current (50Hz) I
FSM
365 365 Amperes I2t (for Fusing), 8.3 milliseconds I2t 667 667 A2sec Storage Temperature T
STG
-40 to 125 -40 to 125 °C
Operating Temperature T
j
-40 to 150 -40 to 150 °C Maximum Mounting Torque M5 Mounting Screw — 17 17 in.-lb. Maximum Mounting Torque M4 Terminal Screw — 12 12 in.-lb. Module Weight (Typical) — 90 90 Grams V Isolation V
RMS
2500 2500 Volts
Page 3
D-27
Powerex,Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272
CD240602, CD241202 Fast Recovery Dual Diode Modules
20 Amperes/600-1200 Volts
Electrical and Thermal Characteristics, Tj= 25°C unless otherwise specified
Characteristics Symbol Test Conditions CD240602/CD241202 Units
Blocking State Maximums
Reverse Leakage Current, Peak I
RRM
Tj= 150°C, V
RRM
= Rated 5.0 mA
Conducting State Maximums
Peak On-State Voltage V
FM
IFM= 20A 1.5 Volts
Switching Maximums
Reverse Recovery Time t
rr
IFM= 20A, Tj= 150°C 0.8 ms
di/dt =-50A/ms, VR = 1/2V
RM
Reverse Recovery Charge Q
rr
IFM= 20A, Tj= 150°C 15 mC
di/dt =-50A/ms, VR = 1/2V
RM
Thermal Maximums
Thermal Resistance, Junction-to-Case R
u(J-C)
Per Module 1.2 °C/Watt
Thermal Resistance, Case-to-Sink (Lubricated) R
u(C-S)
Per Module 0.4 °C/Watt
Page 4
D-28
Powerex,Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272
CD240602, CD241202 Fast Recovery Dual Diode Modules
20 Amperes/600-1200 Volts
INSTANTANEOUS ON-STATE CURRENT, IFM,
(AMPERES)
MAXIMUM
ON-STATE CHARACTERISTICS
0.2 10
-1
0.6
1.4
1.8
2.2
2.6
10
0
10
1
10
2
INSTANTANEOUS ON-STATE VOLTAGE, V
FM
, (VOLTS)
1.0
Tj = 25oC
CYCLES AT 60 HZ
MAXIMUM PEAK SURGE (NON-REPETITIVE)
CURRENT, I
FSM
, (AMPERES)
MAXIMUM ALLOWABLE PEAK SURGE
(NON-REPETITIVE) CURRENT
0
100
200
300
400
500
10
0
10
1
10
2
MAXIMUM
ALLOWABLE CASE TEMPERATURE
AVERAGE ON-STATE CURRENT, I
F(AV)
,
(AMPERES)
MAXIMUM ALLOWABLE CASE TEMPERATURE, T
C
, (
o
C)
02010
100
110
120
130
140
150
DC
515
MAXIMUM
ON-STATE POWER DISSIPATION
AVERAGE ON-STATE CURRENT, I
F(AV)
,
(AMPERES)
MAXIMUM POWER DISSIPATION, P
AV(MAX)
, (WATTS)
02010
0
40
5
10
15
20
25
30
35
DC
515
INSTANTANEOUS ON-STATE CURRENT, IFM,
(AMPERES)
REVERSE RECOVERY
CHARACTERISTICS
10
0
10
1
10
2
I
rr
, (AMPERES), Q
rr
, (µC)
10
0
10
1
10
2
t
rr,
(µs)
10
-1
10
0
10
1
t
rr
I
rr
Q
rr
VR = 600V di/dt = -50A/µs
Tj = 25oC T
j
= 150oC
TIME, t, (SECONDS)
TRANSIENT THERMAL IMPEDANCE
CHARACTERISTICS (JUNCTION-TO-CASE)
0
10
-3
0.4
0.8
1.2
1.6
2.0
10
-2
10
-1
10
0
TRANSIENT THERMAL IMPEDANCE, Z
u(J-C)
(t), (
o
C/WATT)
10
0
10
1
Loading...