1. General Specifications..................................................................................................................................2
5. Test ................................................................................................................................................................... 11
7. Code System of Production Lot ............................................................................................................... 16
8. Type Number..................................................................................................................................................16
ParameterSymbolConditionsMin.Typ.Max.Units
Contrast Ratio Note 1CRθ= 0°,φ =-°-5-
Viewing AngleShown in 3.3
ResponseRise Note 2TON--80160ms
TimeDecay Note 3TOFF--110200ms
Note 1 :Contrast ratio is definded as follows.(CR = LOFF / LON)
LON : Luminance of the ON segments
LOFF : Luminance of the OFF segments
Measuring Spot:0.9mmφ
Note 2 :The time that the luminance level reaches 90% of the saturation level from 0%
when ON signal is applied.
Note 3 :The time that the luminance level reaches 10% of the saturation level from 100%
when OFF signal is applied.
Note 4 :Definition of Driving Voltage VOD
VOD=VCC-VADJ-VBE
Assuming that the typical driving waveforms shown below are applied to the LCD
Panel at 1/A Duty - 1/B Bias (A: Duty Number, B: Bias Number). Driving voltage
VOD is definded as follows.
VOD = (Vth1+Vth2) / 2
Vth1: The voltage VO-P that should provide 70% of the saturation level in the
luminance at the segment which the ON signal is applied to.
Vth2: The voltage VO-P that should provide 20% of the saturation level in the
luminance at the segment which the OFF signal is applied to.
1LED (A)LED Anode Terminal
2LED (K)LED Cathode Terminal
3VSSPower Supply (0V, GND)
4VCCPower Supply for Logic
5VEEPower Supply for LCD Drive
6RSRegister Select Signal
7R/WRead/Write Select Signal H : Read L : Write
8EEnable Signal (No pull-up Resister)
9DB0Data Bus Line / Non-connection at 4-bit operation
10DB1Data Bus Line / Non-connection at 4-bit operation
11DB2Data Bus Line / Non-connection at 4-bit operation
12DB3Data Bus Line / Non-connection at 4-bit operation
13DB4Data Bus Line
14DB5Data Bus Line
15DB6Data Bus Line
16DB7Data Bus Line
The LCD shall be inspected under 40W white fluorescent light.
The distance between the eyes and the sample shall be more than 30cm.
All directions for inspecting the sample should be within 45°against perpendicular line.
45
6.2. Definition of applicable Zones
X : Maximum Seal Line
A Zone : Active display area
B Zone : Out of active display area ~ Maximum seal line
C Zone : Rest parts
The total number of chipped glass defects shall be up to 5 spots.
The chipped glass shall be judged only from the size of the defect.
If the chipped area touches the seal line, the LCD is not acceptable.
The Following precautions will guide you in handling our product correctly.
1) Liquid crystal display devices
1. The liquid crystal display device panel used in the liquid crystal display module is
made of plate glass. Avoid any strong mechanical shock. Should the glass break
handle it with care.
2. The polarizer adhering to the surface of the LCD is made of a soft material.
Guard against scratching it.
2) Care of the liquid crystal display module against static electricity discharge.
1. When working with the module, be sure to ground your body and any electrical
equipment you may be using. We strongly recommend the use of anti static mats
( made of rubber ), to protect work tables against the hazards of electrical shock.
2. Avoid the use of work clothing made of synthetic fibers. We recommend cotton
clothing or other conductivity-treated fibers.
3. Slowly and carefully remove the protective film from the LCD module, since this
operation can generate static electricity.
3) When the LCD module alone must be stored for long periods of time:
1. Protect the modules from high temperature and humidity.
2. Keep the modules out of direct sunlight or direct exposure to ultraviolet rays.
3. Protect the modules from excessive external forces.
4) Use the module with a power supply that is equipped with an overcurrent protector
circuit, since the module is not provided with this protective feature.
5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module.
Should hands or clothing come in contact with LCD fluid, wash immediately with soap.
6) Conductivity is not guaranteed for models that use metal holders where solder
connections between the metal holder and the PCB are not used. Please contact
us to discuss appropriate ways to assure conductivity.
7) For models which use CFL:
1. High voltage of 1000V or greater is applied to the CFL cable connector area.
Care should be taken not to touch connection areas to avoid burns.
2. Protect CFL cables from rubbing against the unit and thus causing the wire jacket
to become worn.
3. The use of CFLs for extended periods of time at low temperatures will significantly
shorten their service life.
8) For models which use touch panels:
1. Do not stack up modules since they can be damaged by components on neighboring
modules.
2. Do not place heavy objects on top of the product. This could cause glass breakage.
9) For models which use COG,TAB,or COF:
1. The mechanical strength of the product is low since the IC chip faces out
unprotected from the rear.
Be sure to protect the rear of the IC chip from external forces.
2. Given the fact that the rear of the IC chip is left exposed, in order to protect the unit
from electrical damage, avoid installation configurations in which the rear of the IC
chip runs the risk of making any electrical contact.
10) Models which use flexible cable, heat seal, or TAB:
1. In order to maintain reliability, do not touch or hold by the connector area.
2. Avoid any bending, pulling, or other excessive force, which can result in broken
connections.
11) In case of buffer material such as cushion / gasket is assembled into LCD module,
it may have an adverse effect on connecting parts ( LCD panel-TCP / HEAT SEAL /
FPC / etc., PCB-TCP / HEAT SEAL / FPC etc., TCP-HEAT SEAL, TCP-FPC, HEAT
SEAL-FPC, etc.,) depending on its materials.
Please check and evaluate these materials carefully before use.
12) In case of acrylic plate is attached to front side of LCD panel, cloudiness ( very
small cracks ) can occur on acrylic plate, being influenced by some components
generated from polarizer film.. Please check and evaluate those acrylic materials
carefully before use.
11. Warranty
This product has been manufactured to your company’s specifications as a part for use
in your company’s general electronic products. It is guaranteed to perform according to
delivery specifications. For any other use apart from general electronic equipment, we
cannot take responsibility if the product is used in medical devices, nuclear power
control equipment, aerospace equipment, fire and security systems, or any other
applications in which there is a direct risk to human life and where extremely high levels
of reliability are required. If the product is to be used in any of the above applications,
we will need to enter into a separate product liability agreement.
1. We cannot accept responsibility for any defect, which may arise from additional
manufacturing of the product (including disassembly and reassembly), after product
delivery.
2. We cannot accept responsibility for any defect, which may arise after the application
of strong external force to the product.
3. We cannot accept responsibility for any defect, which may arise due to the application
of static electricity after the product has passed your company’s acceptance
inspection procedures.
4. When the product is in CFL models, CFL service life and brightness will vary according
to the performance of the inverter used, leaks, etc. We cannot accept responsibility
for product performance, reliability, or defect, which may arise.
5. We cannot accept responsibility for intellectual property of a third party, which may
arise through the application of our product to your assembly with exception to those
issues relating directly to the structure or method of manufacturing of our product.
6. Optrex will not be held responsible for any quality guarantee issue for defect products
judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one)
year from Optrex, Optrex America, Optrex Europe delivery which ever comes later.