FASTRECOVERY RECTIFIER DIODE
VERYHIGHREVERSEVOLTAGECAPABILITY
VERYLOW REVERSE RECOVERYTIME
VERYLOW SWITCHING LOSSES
LOW NOISETURN-OFF SWITCHING
BYT 30P-1000
Cathode connectedto case
SUITABLEAPPLICATIONS
SOD93
(Plastic)
FREE WHEELING DIODE IN CONVERTERS
AND MOTORCONTROL CIRCUITS
RECTIFIERIN S.M.P.S.
ABSOLUTE MAXIMUMRATINGS
Symbol Parameter Value Unit
V
RRM
V
RSM
I
FRM
I
F (RMS)
I
F(AV)
I
FSM
P Power Dissipation T
T
stg
T
Repetitive Peak Reverse Voltage 1000 V
Non RepetitivePeak Reverse Voltage 1000 V
Repetive Peak Forward Current
RMS Forward Current 70 A
Average Forward Current Tc=85°C
Surge non Repetitive Forward Current tp= 10ms
Storage and Junction TemperatureRange - 40 to +150
j
s
t
≤10µ
p
= 0.5
δ
Sinusoidal
=85°C60W
c
375 A
30 A
200 A
- 40 to +150
THERMALRESISTANCE
C
°
Symbol Parameter Value Unit
R
th (j - c)
October 1999 - Ed: 2A 1/5
Junction-case 1
C/W
°

BYT 30P-1000
ELECTRICAL CHARACTERISTICS
STATIC CHARACTERISTICS
Synbol Test Conditions Min. Typ. Max. Unit
I
R
V
F
Tj=25°C
T
= 100°C 5mA
j
Tj=25°C
T
= 100°C
j
V
R=VRRM
I
= 30A 1.9
F
100
1.8
RECOVERYCHARACTERISTICS
Symbol Test Conditions Min. Typ. Max. Unit
t
rr
Tj=25°CI
=1A diF/dt = - 15A/µsVR= 30V
F
I
= 0.5A IR=1A Irr= 0.25A 70
F
165
TURN-OFF SWITCHING CHARACTERISTICS(Without Series Inductance)
Symbol Test Conditions Min. Typ. Max. Unit
V
t
I
IRM
RM
diF/dt = - 120A/µs
di
/dt = - 240A/µs
F
diF/dt = -120A/µs
/dt = - 240A/µs
di
F
= 200V IF= 30A
CC
L
0.05µHT
≤
p
See figure11
= 100°C
j
TURN-OFF OVERVOLTAGECOEFFICIENT(With SeriesInductance
120
)
200 ns
19.5 A
22
µA
V
ns
Symbol Test Conditions Min. Typ. Max. Unit
V
RP
C=
Tj= 100°CV
V
diF/dt = - 30A/µsLp=5µH See figure12
CC
= 200V IF=I
CC
F(AV)
4.5
To evaluatethe conductionlosses use thefollowing equation:
V
= 1.47+ 0.010 I
F
F
Figure1. Low frequency power losses versus
P =1.47 x I
F(AV)
+ 0.010I
F2(RMS)
Figure2. Peak currentversus form factor
average current
2/5

BYT 30P-1000
Figure 3. Non repetitive peak surge current
versus overloadduration
Figure 4. Thermal impedance versus pulse
width
Figure5. Voltagedrop versusforwardcurrent Figure 6. Recoverychargeversus di
F/dt-
Figure7. Recovery time versusdiF/d
t-
Figure8. Peak reversecurrentversus diF/d
t-
3/5

BYT 30P-1000
Figure9. Peak forwardvoltage versusdiF/d
t-
Figure 10. Dynamic para meters v ersus
junctiontemperature.
Figure11. Turn-off switchingcharacteristics(without series inductance).
Figure 12. Turn-off switchingcharacteristics(with series inductance)
4/5

PACKAGE MECHANICAL DATA
SOD93Plastic
DIMENSIONS
REF.
Millimeters
Inches
Min. Typ. Max. Min. Typ. Max.
A 4.70 4.90 0.185 0.193
C 1.17 1.37 0.046 0.054
D 2.50 0.098
D1 1.27 0.050
E 0.50 0.78 0.020 0.031
F 1.10 1.30 0.043 0.051
F3 1.75 0.069
G 10.80 11.10 0.425 0.437
H 14.70 15.20 0.578 0.598
L 12.20 0.480
L2 16.20 0.638
L3 18.0 0.709
L5 3.95 4.15 0.156 0.163
L6 31.00 1.220
O 4.00 4.10 0.157 0.161
Cooling method: by conduction (method C)
Marking: type number
Weight:4.3g
Recommended torque value:80cm. N
Maximum torque value: 100cm. N
Informationfurnishedis believed to beaccurate and reliable. However,STMicroelectronics assumes no responsibility for the consequencesof
use ofsuch information nor forany infringement of patents or other rights of thirdparties which may resultfrom its use.No license is granted
by implication orotherwise under any patentor patent rightsof STMicroelectronics. Specifications mentioned in this publication are subjectto
change without notice. This publication supersedes and replacesall information previously supplied.
STMicroelectronicsproducts arenotauthorizedforuse ascriticalcomponentsinlifesupportdevicesor systems withoutexpress writtenapproval
of STMicroelectronics.
The STlogo isa registeredtrademark of STMicroelectronics
1999STMicroelectronics - Printed in Italy - All rights reserved.
Australia - Brazil - China - Finland - France -Germany - Hong Kong - India - Italy - Japan - Malaysia
Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - U.S.A.
STMicroelectronics GROUP OF COMPANIES
http://www.st.com
5/5