Parameter
Symbol
Rating
Unit
BXP2N65U/D
BXP2N65N
Drain-Source Voltage
V
DSS
650
V
Drain Current Continuous (TC= 25°C)
I
D
2
A
Continuous (TC= 100°C)
1.21
A
Drain Current
Pulsed (Note1)
I
DM
8
A
Gate-Source Voltage
V
GSS
±30
V
Avalanche Energy
Single Pulse (Note2)
E
AS
75
mJ
Repetitive (Note1)
E
AR
6.5
mJ
Avalanche Current (Note1)
I
AR
1.1
A
Peak Diode Recovery dv/dt (Note3)
dv/dt
5
V/ns
Power Dissipation (Note
2)
TC=25°C
P
D
44
3
W
Derate above 25°C
0.35
0.024
W/°C
Maximum Junction Temperature
T
J
150
°C
Storage Temperature Range
T
STG
-55 to 150
°C
Product Name
Marking
Package
Packaging
BXP2N65N
BXP2N65
SOT-223-3L
Reel
BXP2N65U
BXP2N65
TO-251L
Tube
BXP2N65D
BXP2N65
TO-252
Tube/Reel
FEATURES
·RDSON≤5Ω @Vgs=10V, Id=1A
·Excellent R
DS(ON)
and Low Gate Charge
·Fast switching capability
·Lead free product is acquired
General Description
BXP2N65 is Bridgelux high voltage MOSFET family based on
advanced planar stripe DMOS technology. This advanced
MOSFET family has optimized on-state resistance, and also
provides superior switching performance and higher avalanche
energy strength. This device family is suitable for high efficiency
switch mode power supplies.
SYMBOL
SOT-223-3L TO-251L TO-252
ASSEMBLY MESSAGE
BXP2N65
ABSOLUTE MAXIMUM RATINGS
(TC=25°C unless otherwise noted)
Note1. Repetitive Rating: Pulse width limited by maximum junction temperature
2. L=37.5mH, VDD=50V, RG=25 Ω, Starting TJ = 25°C
3. ISD≤ 2.0A, di/dt ≤ 300A/µs, VDD≤ BV
, Starting TJ = 25°C
DSS
Page 2
B r i d g e l u x W u X i R & D C O . , L T D
Brid g el u x WuX i R & D C O . , LTD Page
2
of 11 Version: 2.2
Halogen Free
Parameter
Symbol
Max.
Unit
BXP2N65U/D
BXP2N65N
Thermal Resistance, Junction-to-Case
R
θJC
2.85
41.7
°C / W
Thermal Resistance, Junction-to-Ambient
R
θJA
110
100
°C / W
Parameter
Symbol
Test Condition
Min.
Typ.
Max.
Unit
OFF CHARACTERISTICS
Drain-Source Breakdown Voltage
BV
DSS
VGS=0V, ID=250µA
650
V
Zero Gate Voltage Drain Current
I
DSS
VDS=650V, VGS=0V
1
uA
VDS=520V, TC = 125°C
100
uA
Gate-Body Leakage Current, Forward
I
GSS
VGS=30V
100
nA
Gate-Body Leakage Current, Reverse
VGS=-30V
-100
nA
Breakdown Voltage Temperature
Coefficient
BVDSS/
TJ
ID = 250 µA
0.62
V/
ON CHARACTERISTICS
Gate Threshold Voltage
V
GS(TH)
VDS=VGS, ID=250µA
24V
Drain-Source On-State Resistance
R
DS(ON)
VGS=10V, ID=1A
4.25Ω
Forward Transconductance (Note4)
gFSVDS = 50V, ID = 1A
1.8
S
DYNAMIC PARAMETERS
Input Capacitance
C
ISS
VDS=25V, VGS=0V,
f=1.0MHz
325
pF
Output Capacitance
C
OSS
30
pF
Reverse Transfer Capacitance
C
RSS
5.2
pF
SWITCHING PARAMETERS
Turn-ON Delay Time
t
D(ON)
VDD=325V, ID=2 A, VGS =
10V ,RG=10Ω
(Note4,5)
7
ns
Turn-ON Rise Time
tR5
ns
Turn-OFF Delay Time
t
D(OFF)
26
ns
Turn-OFF Fall-Time
tF10.5
ns
Total Gate Charge(Note5)
Q
G
VDS =520V, VGS =10V, ID
=2A
(Note4,5)
8.5
nC
Gate Source Charge
QGS1.5
nC
Gate Drain Charge
QGD4
nC
SOURCE- DRAIN DIODE RATINGS AND CHARACTERISTICS
Drain-Source Diode Forward Voltage
VSDIS=2A, VGS=0V
1.4
V
Diode Continuous Forward Current
IS2
A
Pulsed Drain-Source Current
ISM8
A
Reverse Recovery Time
t
RR
VGS = 0 V, ISD = 2A
di/dt=100 A/µs (Note4,5)
400
ns
Reverse Recovery Charge
QRR1.15
uC
THERMAL CHARACTERISTICS
BXP2N65
ELECTRICAL CHARACTERISTICST
=25,unless otherwise Noted
J
Note
4. Pulse Test : Pulse width ≤ 300µs, Duty cycle ≤ 2%
5. Essentially independent of operating temperature
Page 3
B r i d g e l u x W u X i R & D C O . , L T D
Brid g el u x WuX i R & D C O . , LTD Page
3
of 11 Version: 2.2
Halogen Free
Id,Drain-to-SourceCurrent(A)
Rds(on),Drain-to-Source Resistance(Ω)
Id,Drain Current(A)
Is,Reverse Drain Current(A)
C,Capacitance(pF)
V
GS
,Gate-to-Source Voltage(V)
TYPICAL CHARACTERISTICS
Figure1. Typical Output Characteristics Figure2. Typical Transfer Characteristics
BXP2N65
Figure3. On-Resistance versus Drain Current Figure4. Diode forward voltage versus Current
Figure5. Typical Capacitance versus V
DS
Figure6. Typical Gate Charge versus V
GS
Page 4
B r i d g e l u x W u X i R & D C O . , L T D
Brid g el u x WuX i R & D C O . , LTD Page
4
of 11 Version: 2.2
Halogen Free
BVDSS,(Normalized)
Drain-to-Source Breakdown Voltage(V)
Rds(on),(Normalized)
Drain-to-Source on Resistance
Id,Drain Current(A)
Id,Drain Current(A)
TYPICAL CHARACTERISTICS(Cont.)
BXP2N65
Figure7. BV
Figure9. Maximum Safe Operating Area Figure10. Maximum Continuous Drain Current
Variation with Temperature Figure8. On-Resistance Variation with Temperature
DSS
versus Case Temperature
Page 5
B r i d g e l u x W u X i R & D C O . , L T D
Brid g el u x WuX i R & D C O . , LTD Page
5
of 11 Version: 2.2
Halogen Free
TEST CIRCUITS AND WAVEFORMS
BXP2N65
Page 6
B r i d g e l u x W u X i R & D C O . , L T D
Brid g el u x WuX i R & D C O . , LTD Page
6
of 11 Version: 2.2
Halogen Free
TEST CIRCUITS AND WAVEFORMS(Cont.)
BXP2N65
Page 7
B r i d g e l u x W u X i R & D C O . , L T D
Brid g el u x WuX i R & D C O . , LTD Page
7
of 11 Version: 2.2
Halogen Free
Dimensions In Millimeters
Symbol
Min
Max
Note
A
6.20
6.60
e
2.28-2.30typ
b
0.66
0.82
b1
2.90
3.10
B
3.30
3.70
B1
6.83
7.15
C
1.45
1.80
C1
0.00
0.15
C2
0.20
0.35
L
0.76
1.16
θ0°10°
SOT-223-3L Package
BXP2N65
Page 8
B r i d g e l u x W u X i R & D C O . , L T D
Brid g el u x WuX i R & D C O . , LTD Page
8
of 11 Version: 2.2
Halogen Free
Symbol
Dimensions In Millimeters
Dimensions In Inches
min.
max.
min.
max.
A
6.00
6.20
0.235
0.245
B
6.45
6.70
0.253
0.264
C
2.05
2.55
0.080
0.101
D
0.70
0.90
0.027
0.036
E
0.49
0.53
0.019
0.021
E1
0.97
1.20
0.038
0.048
e
2.28
2.31
0.089
0.091
L
9.11
9.55
0.358
0.376
L1
0.92
1.55
0.036
0.062
W
0.65
0.95
0.025
0.038
W1
0.75
1.35
0.029
0.054
TO-251 Package
BXP2N65
Page 9
B r i d g e l u x W u X i R & D C O . , L T D
Brid g el u x WuX i R & D C O . , LTD Page
9
of 11 Version: 2.2
Halogen Free
Symbol
Dimensions In Millimeters
Dimensions In Inches
min.
max.
min.
max.
A
6.50
6.70
0.255
0.264
A1
5.25
5.38
0.206
0.212
B
9.80
10.40
0.385
0.410
B1
6.00
6.20
0.236
0.245
B2
2.70
3.10
0.106
0.123
C
0.49
0.52
0.019
0.021
D
2.20
2.40
0.086
0.095
E
2.18
2.39
0.085
0.095
F
0.74
0.80
0.029
0.032
H
0.00
0.30
0.000
0.012
h
0.00
0.13
0.000
0.006
L
6.50
6.70
0.255
0.264
φP
1.10
1.30
0.043
0.052
TO-252 Package
BXP2N65
Page 10
B r i d g e l u x W u X i R & D C O . , L T D
Brid g el u x WuX i R & D C O . , LTD Page
10
of 11 Version: 2.2
Halogen Free
Date
Revision
Changes
16-Mar-2021
1.0
First release
28-Jul-2021
1.1
Corrected parameter
18-Aug-2021
1.2
Add POD
11-Oct-2021
2.0
Update package type
11-Nov-2021
2.1
Update POD
5-Jan-2022
2.2
Update parameter
Revision history
Document revision history
BXP2N65
Page 11
B r i d g e l u x W u X i R & D C O . , L T D
Brid g el u x WuX i R & D C O . , LTD Page
11
of 11 Version: 2.2
Halogen Free
BXP2N65
Disclaimers:
Bridgelux WuXi has made reasonable commercial efforts to ensure that the information given in this data sheet is correct.
However, it must clearly be understood that such information is for guidance only and does not constitute any representation
or form part of any offer or contract.
For documents and material available from this data sheet, Bridgelux WuXi does not warrant or assume any legal liability or
responsibility for the accuracy, completeness, or usefulness of any information, product, technology or process disclosed
hereunder.
Bridgelux WuXi reserves the rights to at its own discretion to make any changes or improvements to this data sheet. Unless
said data sheet is incorporated into the formal contract, any customer should not rely on the information as any specification
or product parameters duly committed by Bridgelux WuXi. Customers are hereby advised to verify that the information
contained herein is current and complete before the entering of any contract or acknowledgement of any purchase order.
Accordingly, all products specified hereunder shall be sold subject to Bridgelux WuXi’s terms and conditions supplied at the
time of order acknowledgement. Except where agreed upon by contractual agreement, testing of all parameters of each
product is not necessarily performed.
Bridgelux WuXi does not warrant or convey any license either expressed or implied under its patent rights, nor the rights of
others. Reproduction of information contained herein shall be only permissible if such reproduction is without any modification
or alteration. Reproduction of this information with any alteration is an unfair and deceptive business practice. Bridgelux WuXi
is not responsible or liable for such altered documentation.
Resale of Bridgelux WuXi’s products with statements different from or beyond the parameters stated by Bridgelux WuXi for
that product or service voids all express or implied warrantees for the associated Bridgelux WuXi’s product or service and is
unfair and deceptive business practice. Bridgelux WuXi is not responsible or liable for any such statements.
Bridgelux WuXi’s products are not authorized for use as critical components in life support devices or systems without the
express written approval of Bridgelux WuXi. As used herein:
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b)
support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result in a significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Loading...