Datasheet BVB01/Z0000/02 Specification

Page 1
IEC Connectors
Power Entry Modules
With over 26,000 combinations Bulgin’s mains power entry modules
oer a very adaptable and exible solution to panel design.
Power entry modules allow combinations of mains inlets and outlets,
ltered inlets, switches, fuseholders, voltage selectors and indicators
mounted in either horizontal or vertical format bezels ready for quick
Our range oers a ange xing alternative for designers who prefer the security of screw xing. All types and variations are available through Bulgin’s extensive distribution network.
268 IEC Connectors
Page 2
IEC Connectors
Power Entry Modules
Components used in Power Entry Modules.
Note: Components are Approved Individually (where applicable). Please see individual
component pages for full specications.
IEC Connectors Fuseholders and Voltage Selectors
Type
DX0928
FX0359
PF0011
PF0033
PX0575
PX0595
PX0695
PX0783
PX0598
VS0001
*Filtered options for 6.3mm tag versions only
Description
Neon Indicator
5 x 20mm Fuseholder
C14 Power Inlet with Integral 5 x 20mm
Fuseholder
C14 Power Inlet with Integral twin 5 x 20mm
Fuseholder
C14 Power Inlet, Cold condition
C16 Power Inlet, Hot Condition
Sheet F Power Outlet
Sheet F Shuttered Power Outlet
C20 Power Inlet
Voltage Selector marked 120/240V
Switches and Indicators
Rating
110V or 250V a.c./d.c. working
Max. rating 10A. 250V
See Page 192
Max. rating 10A. 250V a.c.
See Page 136
Max. rating 10A. 250V a.c.
See Page 137
Max. rating 10A. 250V a.c.
See Page 132
Max. rating 10A. 250V a.c.
See Page 138
Max. rating 10A. 250V a.c.
See Page 145
Max. rating 10A. 250V a.c.
See Page 146
Max. rating 16A, 250V a.c.
See Page 148
Max. rating 6.3A. 120/240V a.c.
See Page 114
Approvals
No Poles
Single Pole
Double Pole
For Mini Bezel: Single Pole
Double Pole
Indicator
RoHS
Power Entry Module range and all components are compliant
Illumination Circuit ApprovalsCurrent Ratings
Non-illuminated
High Inrush
Illuminated
Non-illuminated
High Inrush
Illuminated
Non-illuminated
Illuminated
Non-illuminated
High Inrush
Illuminated
Max. rating 16A Resistive, 4A Inductive, 250Vac.
Max. rating 16A Resistive, 4A Inductive, 250Vac. Inrush current, 150A to IEC65.
Max. rating 16A Resistive, 4A Inductive, 250Vac.
Max. rating 16A Resistive, 4A Inductive, 250Vac.
Max. rating 16A Resistive, 4A Inductive, 250Vac. Inrush current, 150A to IEC65.
Max. rating 16A Resistive, 4A Inductive, 250Vac. 250Vac Neon.
Max. rating 10A Resistive, 4A Inductive, 250Vac.
Max. rating 10A Resistive, 4A Inductive, 250Vac. 250Vac Neon.
Max. rating 10A Resistive, 4A Inductive, 250Vac.
Max. rating 10A Resistive, 4A Inductive, 250Vac. Inrush current, 85A to EN61058-1.
Max. rating 10A Resistive, 4A Inductive, 250Vac.
250Vac Neon.
250Vac neon lamp connected internally to
terminals.
15
15
15
15
15
15
15
15
15
15
15
15
IEC Connectors 269
Page 3
IEC Connectors
Power Entry Modules
Overview of Power Entry Modules
Style C14
Snap to Panel Vertical
Snap to Panel Horizontal
Flange Mount ­Vertical
With Single Pole switch Page 163
With other components Pages 164, 165, 166
Mini Bezel With Single Pole Switch Page 175
Mini Bezel With Double Pole Switch Page 175
C14 Fused
With Single Pole switch Page 161
With Double Pole Switch Page 162
With Single Pole switch Page 170
With Double Pole Switch Page 171
With Single Pole switch Page 176
C16 C20
With Single Pole switch Page 163
With other components Pages 164, 165, 166
With Single Pole switch Page 167
OutletsInlets
Sheet F
With Single Pole switch Page 169
Inlet/ Outet Combinations
C14
With other components Page 168
With Single Pole switch Page 177
C14 Fused
With Double Pole switch Page 173
No additional components Page 174
With Double Pole switch Page 177
270 IEC Connectors
Page 4
IEC Connectors
C14 IEC Fused Inlet - Vertical
Vertical Module Arrangement
BZV01/Z0000/01
How to order -
BZV XX
Type of Inlet / Outlet
Single Fused C14 Power Inlet (cold condition),
6.3 or 2.8mm tabs:
01 = PF0011/63 02 = PF0011/28
Twin Fused C14 Power Inlet (cold condition),
6.3 or 2.8mm tabs:
15 = PF0033/63 16 = PF0033/28
Fused Inlet with 2.8mm or
6.3mm tags Single Pole Switch Variations Filtered Inlet Option Options of I/O marked switches
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th characters from lter
ordering code see pages 179 -180
E.g. BZV01/A0620/01
Filtered or Non Filtered Inlet
Single Pole Switch:
01 = S.P. Switch
Single Pole Neon Switch:
02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch
Neon Indicator: 03 = Red Neon Indicator
Single Pole High Inrush Switch:
46 = S.P. High Inrush Switch
Single Pole Switch Marked I/O:
69 = S.P. Switch (I/O)
Single Pole Neon Switch Marked (I/O):
71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O)
Single Pole High Inrush Switch Marked (I/O):
98 = S.P. High Inrush Switch (I/O)
IEC Connectors 271
Page 5
IEC Connectors
C14 IEC Fused Inlet - Vertical
Vertical Module Arrangement
BZV01/Z0000/10
How to order -
BZV XX
Type of Inlet / Outlet
Single Fused C14 Power Inlet (cold condition),
6.3 or 2.8mm tabs:
01 = PF0011/63 02 = PF0011/28
Twin Fused C14 Power Inlet (cold condition),
6.3 or 2.8mm tabs:
15 = PF0033/63 16 = PF0033/28
Fused Inlet with 2.8mm or
6.3mm tags Double Pole Switch or Indicator Variations Filtered Inlet Option Options of I/O marked switches
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th characters from lter
ordering code see pages 179-180
E.g. BZV01/A0620/10
Combination of Other Components
Neon Indicator: D3 = Red Neon Indicator
Double Pole Switch:
10 = D.P. Switch
Double Pole Neon Switch:
11 = D.P. Red Neon Switch 12 = D.P. Green Neon Switch
Double Pole High Inrush Switch:
13 = D.P. High Inrush Switch
Double Pole Switch Marked I/O:
70 = D.P. Switch (I/O)
Double Pole Neon Switch Marked (I/O):
76 = D.P. Red Neon Switch (I/O) 77 = D.P. Green Neon Switch (I/O)
Double Pole High Inrush Switch Marked (I/O):
78 = D.P. High Inrush Switch (I/O) B1 = D.P. High Inrush Green Neon Switch
(I/O)
272 IEC Connectors
Page 6
IEC Connectors
C14 and C16 IEC Inlet - Vertical
Vertical Module Arrangement
BZV03/Z0000/02
How to order -
BZV XX
Type of Inlet / Outlet
C14 Power Inlet (cold condition), 6.3 or 2.8mm
tabs: 03 = PX0575/63 04 = PX0575/28
C16 Power Inlet (hot condition), 6.3 or 2.8mm
tabs: 05 = PX0595/63 06 = PX0595/28
Please note type 05 and 06 are not available in
ltered version
Inlet with 2.8mm or 6.3mm tags Single Pole Switch or Neon Indicator Variations Filtered Inlet Option Options of I/O marked switches Non Fused
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th characters from
lter ordering code see page 178 E.g. BZV03/A0120/02
Combination of Other Components
Single Pole Switch:
01 = S.P. Switch
Single Pole Neon Switch:
02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch
Neon Indicator: 03 = Red Neon Indicator Single Pole High Inrush Switch:
46 = S.P. High Inrush Switch
Single Pole Switch Marked I/O:
69 = S.P. Switch (I/O)
Single Pole Neon Switch Marked (I/O):
71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O)
Single Pole High Inrush Switch Marked (I/O):
98 = S.P. High Inrush Switch (I/O)
IEC Connectors 273
Page 7
IEC Connectors
C14 and C16 IEC Inlet - Vertical
Vertical Module Arrangement
How to order -
BZV XX
Type of Inlet / Outlet
C14 Power Inlet (cold condition),
6.3 or 2.8mm tabs:
03 = PX0575/63 04 = PX0575/28
C16 Power Inlet (hot
condition), 6.3 or
2.8mm tabs:
05 = PX0595/63 06 = PX0595/28
Please note type 05 and 06 are not available in
ltered version
Inlet with 2.8mm or 6.3mm tags Double Pole Switch/ Fuseholder/Indicator/ Voltage Selectors/ Blanking Plate Filtered Inlet Option Options of I/O marked switches
BZV03/Z0000/07
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th
to 9th characters from lter
ordering code see page 178
E.g. BZV03/A0120/07
Twin Fuseholder and Double Pole
Switch:
05 = 2 x FX0359 + D.P. Switch
Twin Fuseholder and Double Pole Neon
Switch: 06 = 2 x FX0359 + D.P. Red Neon Switch 09 = 2 x FX0359 + D.P. Green Neon Switch 19 = 2 x FX0359 + D.P. Red Neon Switch 125V
Twin Fuseholder and Neon Indicator: 07 = 2 x FX0359 + Red Neon
Indicator
Voltage Selector, Fuseholder and Double Pole Switch:
15 = 1 x VS0001 + 1 x FX0359 +
Double Pole switch
Voltage Selector, Fuseholder and Double Pole Neon Switch:
16 = 1 x VS0001 + 1 x FX0359 + D.P. Red Neon Switch 18 = 1 x VS0001 + 1 x FX0359 + D.P. Green Neon Switch
Voltage Selector, Fuseholder and Neon Indicator:
17 = 1 x VS0001 + 1 x FX0359 + Red
Neon Indicator
Twin Fuseholder and Double Pole High
Inrush Switch:
20 = 2 x FX0359 + D.P. High Inrush
Switch
Twin Fuseholder and Double Pole High
Inrush Neon Switch:
21 = 2 x FX0359 + 1 x D.P. High Inrush Green Neon Switch 22 = 2 x FX0359 + 1 x D.P. High Inrush Red Neon Switch
Combination of Other Components
Voltage Selector, Neon Indicator and Double Pole Switch
25 = 1 x VS0001 + 1 x DX0928/110V/Red + D.P. Switch 26 = 1 x VS0001 + 1 x DX0928/110V/Green + D.P. Switch 27 = 1 x VS0001 + 1 x DX0928/250V/Red + D.P. Switch 28 = 1 x VS0001 + 1 x DX0928/250V/Green + D.P. Switch
Voltage Selector, Neon Indicator and Double Pole High Inrush Switch:
29 = 1 x VS0001 + 1 x DX0928/250V/Red + D.P. High Inrush
Switch
30 = 1 x VS0001 + 1 x DX0928/250V/Green + D.P. High
Inrush Switch
Fuseholder, Neon Indicator and Double Pole Switch
31 = 1 x FX0359 + 1 x DX0928/110V/Red + D.P. Switch 32 = 1 x FX0359 + 1 x DX0928/110V/Green + D.P. Switch 33 = 1 x FX0359 + 1 x DX0928/250V/Red + D.P. Switch 34 = 1 x Fx0359 + 1 x DX0928/250V/Green + D.P. Switch
Fuseholder, Neon Indicator and Double Pole High Inrush Switch:
35 = 1 x FX0359 + 1 x DX0928/250V/Red + D.P. High Inrush
Switch
36 = 1 x FX0359 + 1 x DX0928/250V/Green + D.P. High
Inrush Switch
Fuseholder, Blanking Plate and Double Pole High Inrush Neon Switch:
47 = 1 x FX0359 + 1 x Blanking Plate (Right) + D.P. High Inrush Green Neon
Switch
Fuseholder, Blanking Plate and Double Pole Switch:
48 = 1 x FX0359 + 1 x Blanking Plate (Right) + D.P. Switch
274 IEC Connectors
Page 8
IEC Connectors
C14 and C16 IEC Inlet - Vertical
Vertical Module Arrangement
How to order -
BZV XX
Type of Inlet / Outlet
C14 Power Inlet (cold
condition), 6.3 or 2.8mm
tabs:
03 = PX0575/63 04 = PX0575/28
C16 Power Inlet (hot
condition), 6.3 or 2.8mm
tabs:
05 = PX0595/63 06 = PX0595/28
Please note type 05 and 06 are not available in
ltered version
BZV03/Z0000/07
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th
characters from lter ordering
code see page 178
E.g. BZV03/A0120/07
Inlet with 2.8mm or 6.3mm tags Double Pole Switch/ Fuseholder/Indicator/ Voltage Selectors/ Blanking Plate Filtered Inlet Option Options of I/O marked switches
Combination of Other Components
Twin Fuseholder and Double Pole Switch
Marked (I/O):
72 = 2 x FX0359 + D.P. Switch (I/O)
Twin Fuseholder and Double Pole Neon
Switch Marked (I/O): 73 = 2 x FX0359 + D.P. Red Neon Switch (I/O) 75 = 2 x FX0359 + D.P. Green Neon Switch(I/O) 82 = 2 x FX0359 + D.P. Red Neon Switch 125V(I/O)
Voltage Selector, Fuseholder and Double Pole Switch Marked (I/O):
79 = 1 x VS0001 + 1 x FX0359 +
Double Pole switch (I/O)
Voltage Selector, Fuseholder and Double Pole Neon Switch Marked (I/O):
80 = 1 x VS0001 + 1 x FX0359 + D.P. Red Neon Switch (I/O) 81 = 1 x VS0001 + 1 x FX0359 + D.P. Green Neon Switch (I/O)
Twin Fuseholder and Double Pole High
Inrush Switch Marked (I/O):
83 = 2 x FX0359 + D.P. High Inrush
Switch (I/O)
Twin Fuseholder and Double Pole High
Inrush Neon Switch Marked (I/O):
84 = 2 x FX0359 + 1 x D.P. High Inrush Green Neon Switch (I/O) 85 = 2 x FX0359 + 1 x D.P. High Inrush Red Neon Switch (I/O)
Voltage Selector, Neon Indicator and Double Pole Switch Marked (I/O):
86 = 1 x VS0001 + 1 x DX0928/110V/Red + D.P. Switch (I/O) 87 = 1 x VS0001 + 1 x DX0928/110V/Green + D.P. Switch
(I/O)
88 = 1 x VS0001 + 1 x DX0928/250V/Red + D.P. Switch (I/O) 89 = 1 x VS0001 + 1 x DX0928/250V/Green + D.P. Switch
(I/O)
Voltage Selector, Neon Indicator and Double Pole High Inrush Switch Marked (I/O):
90 = 1 x VS0001 + 1 x DX0928/250V/Red + D.P. High Inrush
Switch(I/O)
91 = 1 x VS0001 + 1 x DX0928/250V/Green + D.P. High
Inrush Switch(I/O)
Fuseholder, Neon Indicator and Double Pole Switch Marked (I/O)
92 = 1 x FX0359 + 1 x DX0928/110V/Red + D.P. Switch (I/O) 93 = 1 x FX0359 + 1 x DX0928/110V/Green + D.P. Switch
(I/O)
94 = 1 x FX0359 + 1 x DX0928/250V/Red + D.P. Switch (I/O) 95 = 1 x FX0359 + 1 x DX0928/250V/Green + D.P. Switch
(I/O)
Fuseholder, Neon Indicator and Double Pole High Inrush Switch Marked (I/O):
96 = 1 x FX0359 + 1 x DX0928/250V/Red + D.P. High Inrush
Switch (I/O)
97 = 1 x FX0359 + 1 x DX0928/250V/Green + D.P. High
Inrush Switch (I/O)
Fuseholder, Blanking Plate and Double Pole High Inrush Neon Switch Marked (I/O):
99 = 1 x FX0359 + 1 x Blanking Plate (Right) + D.P. High Inrush Green Neon
Switch (I/O)
Fuseholder, Blanking Plate and Double Pole Switch Marked (I/O):
A0 = 1 x FX0359 + 1 x Blanking Plate (Right) + D.P. Switch (I/O) B2 = 1 x VS0002 + 1 x Blanking Plate B3 = 1 x FX0359 + 1 x Blanking Plate + D.P. High Inrush Switch (I/O) B5 = 1 x VS0001 + 1 x Blanking Plate + D.P
Switch (I/O)
IEC Connectors 275
Page 9
IEC Connectors
C14 and C16 IEC Inlet - Vertical
Vertical Module Arrangement
BZV04/Z0000/04
How to order -
BZV XX
Type of Inlet / Outlet
C14 Power Inlet (cold condition), 6.3 or
2.8mm tabs:
03 = PX0575/63 04 = PX0575/28
C16 Power Inlet (hot condition), 6.3 or 2.8mm
tabs: 05 = PX0595/63 06 = PX0595/28
Please note type 05 and 06 are not available in
ltered version
Inlet with 2.8mm or 6.3mm tags Fuseholder/Voltage Selector/Indicator options/Blanking plate
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th characters from
lter ordering code see page 178 E.g. BZV03/A0120/04
Combination of Other Components
Twin Fuseholder: 04 = 2 x FX0359
Voltage Selector and Fuseholder:
14 = 1 x VS0001 + 1 x FX0359
Voltage selector and Neon:
37 = 1 x VS0001 + DX0928/110V/Red 38 = 1 x VS0001 + DX0928/110V/Green 39 = 1 x VS0001 + DX0928/250V/Red 40 = 1 x VS0001 + DX0928/250V/Green
Fuseholder and Neon:
41 = 1 x FX0359 + DX0928/110V/Red 42 = 1 x FX0359 + DX0928/110V/Green 43 = 1 x FX0359 + DX0928/250V/Red 44 = 1 x FX0359 + DX0928/250V/Green
Fuseholder and Blanking Plate:
45 = 1 x FX0359 + Blanking Plate
Voltage Selector and Blanking Plate:
B2 = 1 x VS0001 + Blanking Plate
276 IEC Connectors
Page 10
IEC Connectors
C20 IEC Inlet - Vertical
Vertical Module Arrangement
BZV49/Z0000/69
How to order -
BZV XX
Type of Inlet / Outlet
C20 Power Inlet (cold condition), 4.8 or
6.3mm tabs:
49 = PX0598/63 50 = PX0598/48
Inlet with 4.8mm or 6.3mm tags Single Pole Switch marked I/O Illuminated, red or green, switches High inrush non-illuminated switch
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Combination of Other Components
Single Pole Switch:
01 = S.P. Switch
Single Pole Switch Marked (I/O):
69 = S.P. Switch (I/O)
Single Pole Illuminated Switch:
02 = S.P. Illuminated Red 08 = S.P. Illuminated Green
Single Pole Non-illuminated High Inrush Switch Marked I/O:
98 = S.P. High Inrush Switch (I/O) Single Pole Illuminated (Red or Green 250v
Neon) Switch Marked I/O:
71 = S.P. Switch Illuminated Red (I/O) 74 = S.P. Switch Illuminated Green (I/O)
IEC Connectors 277
Page 11
IEC Connectors
C14 IEC Inlet/Sheet F IEC Outlet - Vertical
Vertical Module Arrangement
BZV09/Z0000/04
How to order -
BZV XX
Type of Inlet / Outlet
C14 Power Inlet (cold condition) and Sheet F
Non-shuttered Power Outlet, 2.8 or 6.3mm tabs:
09 = PX0575/63 + PX0695/63 10 = PX0575/28 + PX0695/28
C14 Power Inlet (cold condition) and Sheet F
Shuttered Power Outlet, 2.8 or 6.3mm tabs:
17 = PX0575/63 + PX0783/63 18 = PX0575/28 + PX0783/28
Inlet/Outlet Combination
2.8mm or 6.3mm tags Filtered Inlet and Blanking Plate options Shuttered or Non-shuttered Outlet Fused
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th characters from
lter ordering code see page 178 E.g. BZV09/A0120/04
Combination of Other Components
Twin Fuseholder: 04 = 2 x FX0359
Voltage Selector and Fuseholder:
14 = 1 x VS0001 + 1 x FX0359
Voltage selector and Neon:
37 = 1 x VS0001 + DX0928/110V/Red 38 = 1 x VS0001 + DX0928/110V/Green 39 = 1 x VS0001 + DX0928/250V/Red 40 = 1 x VS0001 + DX0928/250V/Green
Fuseholder and Neon:
41 = 1 x FX0359 + DX0928/110V/Red 42 = 1 x FX0359 + DX0928/110V/Green 43 = 1 x FX0359 + DX0928/250V/Red 44 = 1 x FX0359 + DX0928/250V/Green
Fuseholder and Blanking Plate:
45 = 1 x FX0359 + Blanking Plate
Voltage Selector and Blanking Plate:
B2 = 1 x VS0001 + Blanking Plate
278 IEC Connectors
Page 12
IEC Connectors
Sheet F IEC Outlet - Vertical
Vertical Module Arrangement
BZV45/Z0000/02
How to order -
BZV XX
Type of Inlet / Outlet
Sheet F Power Outlet (non shuttered), 6.3 or
2.8mm tabs:
45 = PX0695/63 46 = PX0695/28
Sheet F Power Outlet (shuttered), 6.3 or
2.8mm tabs:
47 = PX0783/63 48 = PX0783/28
Outlet with 2.8mm or 6.3mm tags Shuttered or Non-Shuttered Single Pole Switch or Neon Indicator I/O Marking Options
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Combination of Other Components
Single Pole Switch:
01 = S.P. Switch
Single Pole Neon Switch:
02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch
Neon Indicator:
03 = Red Neon Indicator
Single Pole High Inrush Switch:
46 = S.P. High Inrush Switch
Single Pole Switch Marked I/O:
69 = S.P. Switch (I/O)
Single Pole Neon Switch Marked (I/O):
71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O)
Single Pole High Inrush Switch Marked (I/O):
98 = S.P. High Inrush Switch (I/O)
IEC Connectors 279
Page 13
IEC Connectors
C14 IEC Fused Inlet - Horizontal
Horizontal Module Arrangement
BZH01/Z0000/01
How to order -
BZH XX
Type of Inlet / Outlet
Single Fused C14 Power Inlet (cold condition),
2.8 or 6.3mm tabs:
01 = PF0011/63 02 = PF0011/28
Twin Fused C14 Power Inlet (cold condition),
2.8 or 6.3mm tabs:
15 = PF0033/63 16 = PF0033/28
Fused Inlet with 2.8mm or
6.3mm tags Single Pole Switch Variations Filtered Inlet Option Options of I/O marked switches
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th characters from
lter ordering code see pages 179-180 E.g. BZH01/A0620/01
Combination of Other Components
Single Pole Switch:
01 = S.P. Switch
Single Pole Neon Switch:
02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch
Neon Indicator: 03 = Red Neon Indicator
Single Pole High Inrush Switch:
46 = S.P. High Inrush Switch
Single Pole Switch Marked I/O:
69 = S.P. Switch (I/O)
Single Pole Neon Switch Marked (I/O):
71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O)
Single Pole High Inrush Switch Marked (I/O):
98 = S.P. High Inrush Switch (I/O)
280 IEC Connectors
Page 14
IEC Connectors
C14 IEC Fused Inlet - Horizontal
Horizontal Module Arrangement
BZH01/Z0000/10
How to order -
BZH XX
Type of Inlet / Outlet
Single Fused C14 Power Inlet (cold condition),
2.8 or 6.3mm tabs:
01 = PF0011/63 02 = PF0011/28
Twin Fused C14 Power Inlet (cold condition),
2.8 or 6.3mm tabs:
15 = PF0033/63 16 = PF0033/28
Fused Inlet with 2.8mm or
6.3mm tags Double Pole Switch Variations Filtered Inlet Option Options of I/O marked switches
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th characters from
lter ordering code see pages 179-180 E.g. BZH01/A0620/10
Combination of Other Components
Neon Indicator: 03 = Red Neon Indicator
Double Pole Switch:
10 = D.P. Switch
Double Pole Neon Switch:
11 = D.P. Red Neon Switch 12 = D.P. Green Neon Switch
Double Pole High Inrush Switch:
13 = D.P. High Inrush Switch
Double Pole Switch marked I/O:
70 = D.P. Switch (I/O)
Double Pole Neon Switch Marked (I/O):
76 = D.P. Red Neon Switch (I/O) 77 = D.P. Green Neon Switch (I/O)
Double Pole High Inrush Switch Marked (I/O):
78 = D.P. High Inrush Switch (I/O) B1 = D.P. High Inrush Green Neon Switch
(I/O)
IEC Connectors 281
Page 15
IEC Connectors
C14 IEC Fused Inlet - Horizontal
Horizontal Module Arrangement
BZH09/Z0000/01
How to order -
BZH XX
Type of Inlet / Outlet
C14 Power Inlet (cold condition) and Sheet F
Non-shuttered Power Outlet, 2.8 or 6.3mm tabs:
09 = PX0575/63 + PX0695/63 10 = PX0575/28 + PX0695/28
C14 Power Inlet (cold condition) and Sheet F
Shuttered Power Outlet , 2.8 or 6.3mm tabs:
17 = PX0575/63 + PX0783/63 18 = PX0575/28 + PX0783/28
Inlet/Outlet Combination with 2.8mm or 6.3mm tags Shuttered or Non-Shuttered Outlet Single Pole Switch Variations Filtered Inlet Option Options of I/O marked switches
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th characters from
lter ordering code see page 178 E.g. BZH09/A0120/01
Combination of Other Components
Single Pole Switch:
01 = S.P. Switch
Single Pole Neon Switch:
02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch
Neon Indicator: 03 = Red Neon Indicator
Single Pole High Inrush Switch:
46 = S.P. High Inrush Switch
Single Pole Switch Marked I/O:
69 = S.P. Switch (I/O)
Single Pole Neon Switch Marked (I/O):
71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O)
Single Pole High Inrush Switch Marked (I/O):
98 = S.P. High Inrush Switch (I/O)
282 IEC Connectors
Page 16
IEC Connectors
C14 IEC Inlet/Sheet F IEC Outlet - Horizontal
Horizontal Module Arrangement
BZH11/Z0000/10
How to order -
BZH XX
Type of Inlet / Outlet
Single Fused C14 Power Inlet (cold condition) and
Sheet F Power Outlet, 2.8 or 6.3mm tabs:
11 = PF0011/63 + PX0695/63 12 = PF0011/28 + PX0695/28
Twin Fused C14 Power Inlet (cold condition) and Sheet F Power Outlet , 2.8 or 6.3mm tabs:
13 = PF0033/63 + PX0695/63 14 = PF0033/28 + PX0695/28
Single Fused C14 Power Inlet (cold condition) and
Sheet F Shuttered Power Outlet, 2.8 or 6.3mm tabs:
19 = PF0011/63 + PX0783/63 20 = PF0011/28 + PX0783/28
Twin Fused C14 Power Inlet (cold condition) and Sheet F Shuttered Power Outlet , 2.8 or 6.3mm tabs:
21 = PF0033/63 + PX0783/63 22 = PF0033/28 + PX0783/28
Inlet/Outlet Combination with 2.8mm or 6.3mm tags Single or Twin Fused Inlet Shuttered or Non-Shuttered Outlet Double Pole Switch Variations Filtered Inlet Option Options of I/O marked switches
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th characters from
lter ordering code see pages 179-180 E.g. BZH11/A0620/10
Combination of Other Components
Neon Indicator: D3 = Red Neon Indicator
Double Pole Switch:
10 = D.P. Switch
Double Pole Neon Switch:
11 = D.P. Red Neon Switch 12 = D.P. Green Neon Switch
Double Pole High Inrush Switch:
13 = D.P. High Inrush Switch
Double Pole Switch Marked I/O:
70 = D.P. Switch (I/O)
Double Pole Neon Switch Marked (I/O):
76 = D.P. Red Neon Switch (I/O) 77 = D.P. Green Neon Switch (I/O)
Double Pole High Inrush Switch Marked (I/O):
78 = D.P. High Inrush Switch (I/O) B1 = D.P. High Inrush Green Neon Switch (I/O)
IEC Connectors 283
Page 17
IEC Connectors
C14 IEC Inlet/Sheet F IEC Outlet - Horizontal
Horizontal Module Arrangement
BZH11/Z0000/00
How to order -
BZH XX
Type of Inlet / Outlet
Single Fused C14 Power Inlet (cold condition) and
Sheet F Non-shuttered Power Outlet, 2.8 or 6.3mm
tabs:
11 = PF0011/63 + PX0695/63 12 = PF0011/28 + PX0695/28
Twin Fused C14 Power Inlet (cold condition) and Sheet F Non-shuttered Power Outlet , 2.8 or 6.3mm
tabs:
13 = PF0033/63 + PX0695/63 14 = PF0033/28 + PX0695/28
Single Fused C14 Power Inlet (cold condition) and
Sheet F Shuttered Power Outlet, 2.8 or 6.3mm tabs:
19 = PF0011/63 + PX0783/63 20 = PF0011/28 + PX0783/28
Twin Fused C14 Power Inlet (cold condition) and Sheet F Shuttered Power Outlet , 2.8 or 6.3mm tabs:
21 = PF0033/63 + PX0783/63 22 = PF0033/28 + PX0783/28
Fused Inlet/Outlet Combination with 2.8mm or
6.3mm tags Filtered Inlet Option Single or Twin Fused
XXXXX XX
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th characters from
lter ordering code see pages 179-180 E.g. BZH11/A0620/00
Combination of Other Components
None
00 = None
284 IEC Connectors
Page 18
IEC Connectors
C14 IEC Inlet - Mini Bezel
Minimum Combined Bezel Size
BZM27/Z0000/57B
How to order -
BZM XX
Type of Inlet / Outlet
C14 Power Inlet (cold
condition), 6.3, 4.8 &
2.8mm tabs:
27 = PX0575/63 42 = PX0575/48 28 = PX0575/28
Filtered or Non Filtered Inlet
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th
characters from lter ordering
code see page 178
E.g. BZM27/A0120/57B
Inlet with 2.8, 4.8 or 6.3mm tags Horizontal Module Arrangement Single and Double Pole Switch Variations Filtered Inlet Option
XXXXX XX X
Switch Variation
Single Pole Switch, 4.8mm or solder tab, marked I/O: 53 = S.P. Switch, 4.8mm tab (I/O) 54 = S.P. Switch, solder tab (I/O)
Single Pole Illuminated Switch, 4.8mm or solder tab: 55 = S.P. Switch Illum. Red, 4.8mm tab 61 = S.P. Switch Illum. Green, 4.8mm tab 56 = S.P. Switch Illum. Red, solder tab 62 = S.P. Switch Illum. Green, solder tab
Double Pole Switch, 4.8mm or solder tab, marked I/O: 57 = D.P. Switch, 4.8mm tab (I/O) 58 = D.P. Switch, solder tab (I/O)
Double Pole Illuminated Switch, 4.8mm or solder tab: 59 = D.P. Switch Illum. Red, 4.8mm tab 63 = D.P. Switch Illum. Green, 4.8mm tab 60 = D.P. Switch Illum. Red, solder tab 64 = D.P. Switch Illum. Green, solder tab
Double Pole High Inrush, 4.8mm tabs: 65 = D.P. High Inrush Switch, 4.8mm tabs (S.P. format)
Double Pole High Inrush, 4.8mm tabs, marked I/O: 68 = D.P. High Inrush Switch, 4.8mm tabs, I/O (S.P.
format)
Single Pole Illuminated Switch, 4.8mm or solder tab,
Marked I/O:
A1 = S.P. Switch Illum. Red, 4.8mm tab (I/O) A5 = S.P. Switch Illum. Green, 4.8mm tab (I/O) A2 = S.P. Switch Illum. Red, solder tab (I/O) A6 = S.P. Switch Illum. Green, solder tab (I/O)
Double Pole Illuminated Switch, 4.8mm or solder tab,
Marked I/O:
A3 = D.P. Switch Illum. Red, 4.8mm tab A7 = D.P. Switch Illum. Green, 4.8mm tab A4 = D.P. Switch Illum. Red, solder tab A8 = D.P. Switch Illum. Green, solder tab
Panel Thickness
1.0mm = A
1.5mm = B
2.0mm = C
3.0mm = D
IEC Connectors 285
Page 19
IEC Connectors
C14 IEC Fused Inlet - Polyange
Vertical Module Arrangement
Vertical Module Arrangement
How to order -
BV X
Flange Type
BVA01/Z0000/02
BVB01/Z0000/01
XX XX
Type of Inlet / Outlet
Fused Inlet with 2.8mm or
6.3mm tags Screw Fixing to Panel Single Pole Switch Variations Filtered Inlet Option Options of I/O marked switches
Fused Inlet with 2.8mm or
6.3mm tags Screw Fixing to Panel Single Pole Switch Variations Filtered Inlet Option Options of I/O marked switches
XXXXX
Filtered or Non Filtered Inlet Combination of Other Components
A = Top xing
B = Side xing
Single Fused C14 Power Inlet
(cold condition), 6.3 or 2.8mm
tabs:
01 = PF0011/63 02 = PF0011/28
Twin Fused C14 Power Inlet (cold condition), 6.3 or 2.8mm
tabs:
15 = PF0033/63 16 = PF0033/28
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th
characters from lter ordering code see
pages 179-180
E.g. BVA01/A0620/01
Single Pole Switch:
01 = S.P. Switch
Single Pole Neon Switch:
02 = S.P. Red Neon Switch 08 = S.P. Green Neon Switch
Neon Indicator: 03 = Red Neon Indicator
Single Pole High Inrush Switch:
46 = S.P. High Inrush Switch
Single Pole Switch Marked I/O:
69 = S.P. Switch (I/O)
Single Pole Neon Switch Marked (I/O):
71 = S.P. Red Neon Switch (I/O) 74 = S.P. Green Neon Switch (I/O)
Single Pole High Inrush Switch Marked (I/O):
98 = S.P. High Inrush Switch (I/O)
286 IEC Connectors
Page 20
IEC Connectors
C14 IEC Fused Inlet - Polyange
Vertical Module Arrangement
Vertical Module Arrangement
How to order -
BV X
Flange Type
BVA01/Z0000/10
BVB01/Z0000/11
XX XXXXX XX
Type of Inlet / Outlet
Fused Inlet with 2.8mm or
6.3mm tags Screw Fixing to Panel Double Pole Switch Variations Filtered Inlet Option Options of I/O marked switches
Fused Inlet with 2.8mm or
6.3mm tags Screw Fixing to Panel Double Pole Switch Variations Filtered Inlet Option Options of I/O marked switches
Filtered or Non Filtered Inlet Combination of Other Components
A = Top xing
B = Side xing
Fused C14 Power Inlet (cold
condition), 6.3 or 2.8mm tabs:
01 = PF0011/63 02 = PF0011/28
Twin Fused C14 Power Inlet (cold condition), 6.3 or 2.8mm
tabs:
15 = PF0033/63 16 = PF0033/28
Z0000 = Non Filtered
Axxxx = Standard
For Filtered inlet use 6th to 9th
characters from lter ordering code see
pages 179-180
E.g. BVA01/A0620/10
Neon Indicator: D3 = Red Neon Indicator
Double Pole Switch:
10 = D.P. Switch
Double Pole Neon Switch:
11 = D.P. Red Neon Switch 12 = D.P. Green Neon Switch
Double Pole High Inrush Switch:
13 = D.P. High Inrush Switch
Double Pole Switch Marked I/O:
70 = D.P. Switch (I/O)
Double Pole Neon Switch Marked (I/O):
76 = D.P. Red Neon Switch (I/O) 77 = D.P. Green Neon Switch (I/O)
Double Pole High Inrush Switch Marked (I/O):
78 = D.P. High Inrush Switch (I/O) B1 = D.P. High Inrush Green Neon Switch
(I/O)
IEC Connectors 287
Page 21
IEC Connectors
C14 IEC Fused Inlet
EMI Filter Options
How to order -
B XXXX
Polysnap Part No.
From Polysnap Selection
BVA01/Z0000/10
A XX X X XX
Filter Type
A = Standard
For Polysnap modules BZV03, BZV04, BZV09, BZV10, BZV17, BZV18, BZH09, BZH10, BZH17, BZH18, BZM27, BZM28 PX0575 style IEC inlet
Using PS01/A style lter
Standard Attenuation Filter
Rating L/C Circuit
01 = 1A
03 = 3A
06 = 6A
10 = 10A
1 = Version 1
2 = Version 2
3 = Version 3
Additional Components
0 = None
Polysnap Part No.
From Polysnap Selection
Rating
1 AMP
“ “
3 AMP
“ “
6 AMP
“ “
10 AMP
“ “
Version
1 2 3
1 2 3
1 2 3
1 2 3
Filter Specication
Max. Working Voltage: Earth Leakage Current: Temperature Range: Max. Ambient Temp.: (@ Full Load) Test Voltage:
Approvals:
Attenuation Curves:
L1
2 x 2.8mH 2 x 10mH 2 x 10mH
2 x 0.75mH 2 x 1.8mH 2 x 1.8mH
2 x 0.3mH 2 x 0.7mH 2 x 0.7mH
2 x 0.17mH 2 x 0.35mH 2 x 0.17mH
250V a.c. 50-400Hz <0.35mA (250V. 50Hz) –25ºC to +85ºC 40ºC (derate linearly to 0A @ 85ºC)
2700V d.c. 2 secs. Lines to Earth 1100V d.c. 2 secs. Live to Neutral
See PS01/A lter, page 183
Cx
1 x 15nF 1 x 15nF 1 x 47nF
1 x 15nF 1 x 15nF 1 x 47nF
1 x 15nF 1 x 15nF 1 x 47nF
1 x 15nF 1 x 15nF 1 x 47nF
Cy
2 x 2.2nF 2 x 2.2nF 2 x 2.2nF
2 x 2.2nF 2 x 2.2nF 2 x 2.2nF
2 x 2.2nF 2 x 2.2nF 2 x 2.2nF
2 x 2.2nF 2 x 2.2nF 2 x 2.2nF
Part No. Example
BZV03/A0120/02
BZV style Polysnap module with PX0575 IEC
power inlet, lter rated at 1 amp, L/C circuit version 2 (L1 = 2 x 10mH, Cx = 1 x 15nF, Cy = 2 x 2.2nF) 6.3mm tabs and single pole red neon switch.
288 IEC Connectors
Page 22
IEC Connectors
C14 Inlet Single Fuse - Standard Filter
EMI Filter Options
How to order -
B XXXX
Polysnap Part No.
From Polysnap Selection
For Polysnap modules BZV01, BZV02, BZH01, BZH02, BZH11, BZH12, BZH19, BZH20, BVA01, BVA02, BVB01, BVB02 PF0011 style single fuse IEC inlet
Using PS21/A style lter
Standard Attenuation Filter
A XX X X XX
Filter Type
A = Standard
Rating L/C Circuit
01 = 1A
03 = 3A
06 = 6A
2 = Version 2
3 = Version 3
Additional Components
0 = None
Polysnap Part No.
From Polysnap Selection
Rating
1 AMP
“ “
3 AMP
“ “
6 AMP
“ “
10 AMP
“ “
Filter Specication
Max. Working Voltage: Earth Leakage Current: Temperature Range: Max. Ambient Temp.: (@ Full Load) Test Voltage:
Approvals:
Attenuation Curves:
Version
1 2 3
1 2 3
1 2 3
1 2 3
L1
2 x 12mH
2 x 1.8mH 2 x 6.5mH
2 x 0.7mH 2 x 2mH
250V a.c. 50-400Hz <0.35mA (250V. 50Hz) –25ºC to +85ºC 40ºC (derate linearly to 0A @ 85ºC)
2700V d.c. 2 secs. Lines to Earth 1100V d.c. 2 secs. Live to Neutral
See PS21/A lter, page 187
Cx
1 x 47nF
1 x 15nF 1 x 47nF
1 x 15nF 1 x 47nF
Cy
2 x 2.2nF
2 x 2.2nF 2 x 2.2nF
2 x 2.2nF 2 x 2.2nF
Part No. Example
BZV01/A0630/01
BZV style Polysnap module with PF0011 single
fused (5 x 20mm) IEC power inlet, lter rated at 6 amp, L/C circuit version 3 (L1 = 2 x 2.0mH, Cx = 1 x 47nF, Cy = 2 x 2.2nF), 6.3mm tabs and single pole switch.
IEC Connectors 289
Page 23
IEC Connectors
C14 Inlet Twin Fuse - Standard Filter
EMI Filter Option
How to order -
B XXXX
Polysnap Part No.
From Polysnap Selection
Rating
1 AMP
“ “
4 AMP
“ “
Version
1 2 3
1 2 3
For Polysnap modules BZV15, BZV16, BZH13, BZH14, BZH15, BZH16, BZH21, BZH22, BVA15, BVA16, BVB15, BVB16 PF0033 style twin fuse IEC inlet
Using PS26/A lter
Standard Attenuation Filter
A XX X X XX
Filter Type
A = Standard
L1
2 x 1.8mH
2 x 0.7mH
Cx
1 x 15nF
1 x 15nF
Rating L/C Circuit
02 = 2A
04 = 4A
Cy
2 x 2.2nF
2 x 2.2nF
2 = Version 2
Additional
Components
0 = None
Part No. Example
BZH13/A0420/00
BZH style Polysnap module with PF0033 twin
fused (5 x 20mm) IEC power inlet, lter rated at 4 amps, L/C circuit version 2 (L1 = 2 x 0.7mH, Cx = 1 x 15nF, Cy = 2 x 2.2nF) 6.3mm tabs and no additional components.
Polysnap Part No.
From Polysnap Selection
Filter Specication
Max. Working Voltage: Earth Leakage Current: Temperature Range: Max. Ambient Temp.: (@ Full Load) Test Voltage:
Approvals:
Attenuation Curves:
250V a.c. 50-400Hz <0.35mA (250V. 50Hz) –25ºC to +85ºC 40ºC (derate linearly to 0A @ 85ºC)
2700V d.c. 2 secs. Lines to Earth 1100V d.c. 2 secs. Live to Neutral
See PS26/A lter, page 189
290 IEC Connectors
Loading...