DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 2
BA TRON
BTHQ 42008VSS-01
DOCUMENT REVISION HISTORY 1:
2/11
DOCUMENT
REVISION
FROM TO
A 2002.02.01 First Release. PHILIP
DATE DESCRIPTION CHANGED
BY
CHENG
CHECKED
BY
M.Y.LU
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 3
BA TRON
BTHQ 42008VSS-01
CONTENTS
Page No.
1. GENERAL DESCRIPTION 4
2. MECHANICAL SPECIFICATIONS 4
3. INTERFACE SIGNALS 6
4. ABSOLUTE MAXIMUM RATINGS 7
4.1
4.2 ENVIRONMENTAL CONDITION 7
5. ELECTRICAL SPECIFICATIONS 8
5.1 TYPICAL ELECTRICAL CHARACTERISTICS 8
5.2 TIMING SPECIFICATIONS 9
5.3 TIMING DIAGRAM OF VDD AGAINST V0 11
ELECTRICAL MAXIMUM RATINGS (Ta=25°C)
7
3/11
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 4
BA TRON
BTHQ 42008VSS-01
1. General Description
4/11
Specification
of
LCD Module Type
Item No.: BTHQ 42008VSS-01
• 20 characters (5 x 8 dots) x 4 lines STN Positive Yellow Transflective LCD Character Module.
• Viewing Angle: 6 O’clock direction.
• Driving duty: 1/16 Duty, 1/5 bias.
• ‘SAMSUNG’ KS0066UP-10BCC(Die form) LCD Controller & Driver or equivalent.
• ‘SAMSUNG’ KS0065B-PCC(Die form) LCD Segment Drivers or equivalent.
• Yellow-green LED04 backlight.
2. Mechanical Specifications
The mechanical detail is shown in Fig. 1 and summarized in Table 1 below.
Table 1
Parameter Specifications Unit
Outline dimensions 146.0(W) x 62.5(H) x 14.0 MAX.(D) mm
Effective viewing area 123.0(W) x 42.5(H) mm
Display format 20 characters x 4 lines Character size 4.84(W) x 9.22(H) (5 x 8 dots) mm
Character spacing 1.16(W) x 0.53(H) mm
Character pitch 6.00(W) x 9.75(H) mm
Dot size 0.956(W) x 1.139(H) mm
Dot spacing 0.015(W) x 0.015(H) mm
Dot pitch 0.971(W) x 1.154(H) mm
Weight Approx. 123 grams
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 5
BA TRON
BTHQ 42008VSS-01
5/11
Figure 1: Module Specification
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 6
BA TRON
BTHQ 42008VSS-01
3. Interface signals
Pin No. Symbol Description
1 VSS Ground (0V).
2 VDD Power supply for logic (+5.0V).
3 V0 Power supply for LCD driver.
4 RS Register Select Input:
5 R/W Read/Write signal:
6 E Enable.
7 DB0 Data input/output (LSB)
8 DB1 Data input/output
9 DB2 Data input/output
10 DB3 Data input/output
11 DB4 Data input/output
12 DB5 Data input/output
13 DB6 Data input/output
14 DB7 Data input/output (MSB)
A LED(+) Anode of LED Backlight
K LED(-) Cathode of LED Backlight
Table 2
”High’ for Data register (for read and write).
”Low” for Instruction register (for write),
Busy flag, address counter (for read).
‘High’ for Read mode.
‘Low’ for Write mode.
Start signal for data read /write.
6/11
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 7
A
H
V
H
BA TRON
BTHQ 42008VSS-01
4. Absolute Maximum Ratings
4.1 Electrical Maximum Ratings(Ta = 25 ºC)
ParameterSymbolMin.Max.Unit
Power Supply voltage (Logic)VDD-VSS-0.3+7.0V
Power Supply voltage
(LCD drive)
Input voltageVin-0.3VDD+0.3V
Note:
Table 3
VLCD
=VDD-V0
-0.3+15.0V
7/11
The modules may be destroyed if they are used beyond the absolute maximum ratings.
All voltage values are referenced to VSS = 0V.
4.2 Environmental Condition
Table 4
Item
mbient Temperature
umidity
ibration (IEC 68-2-6)
cells must be mounted
on a suitable connector
Shock (IEC 68-2-27)
alf-sine pulse shape
Operating
Temperature
(Topr)
Min. Max. Min. Max.
0°C +50°C -10°C +60°C
95% max. RH for Ta ≤ 40°C
< 95% RH for Ta > 40°C
Frequency: 10 ∼ 55 Hz
Amplitude: 0.75 mm
Duration: 20 cycles in each direction.
Pulse duration : 11 ms
Peak acceleration: 981 m/s2= 100g
Number of shocks : 3 shocks in 3
mutually perpendicular axes.
Storage
Temperature
(Tstg)
Remark
Dry
no condensation
3 directions
3 directions
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 8
BA TRON
BTHQ 42008VSS-01
8/11
5. Electrical Specifications
5.1 Typical Electrical Characteristics
At Ta = 25 °C, VDD = 5V±5%, VSS=0V.
Table 5
Parameter Symbol Conditions Min. Typ. Max. Unit
Supply voltage (Logic) VDD -VSS 4.75 5.0 5.25 V
Supply voltage (LCD) VLCD
=VDD –V0
V
”H” level 2.2 - VDD V Input signal voltage 1
IH1
for E,DB0-DB7,R/W,RS.
for OSC1.
Supply Current
V
” L” level -0.3 - 0.6 V
IL1
V
” H” level VDD –1 - VDD V Input signal voltage 2
IH2
V
” L” level -0.2 - 1.0 V
IL2
IDD Character mode,
(Logic & LCD)
Supply Current (LCD) I0 Character mode,
VDD = 5V,
Note (1)
VDD=5V, Note 1
7.2 7.7 8.2 V
- 2.4 3.6 mA
- 1.5 2.3 mA
VDD=5V, Note 1
Supply Voltage of
yellow-green LED04
VLED Forward current
=540 mA
3.9 4.1 4.3 V
backlight
Number of LED die
= 2x54
=108
Note (1) : There is tolerance in optimum LCD driving voltage during production and it will be within
the specified range.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 9
BA TRON
BTHQ 42008VSS-01
5.2 Timing Specifications
At Ta = 0 °C To +50 °C , VDD = +5V±5%, VSS = 0V.
Refer to Fig. 2, the bus timing diagram for write mode.
Table 6
Parameter Symbol Min. Max. Unit
E Cycle Time tc 500 - ns
E Rise/Fall Time tR,tF - 20 ns
E Pulse Width(high, low) tW 230 - ns
R/W and RS Setup Time t
40 - ns
SU1
R/W and RS Hold Time tH1 10 - ns
Data Set-up Time t
80 - ns
SU2
Data Hold Time tH2 10 - ns
9/11
Refer to Fig. 3, the bus timing diagram for read mode.
Table 7
Parameter Symbol Min. Max. Unit
E Cycle Time tc 500 - ns
E Rise/Fall Time tR,tF - 20 ns
E Pulse Width(high, low) tW 230 - ns
R/W and RS Setup Time tSU 40 - ns
R/W and RS Hold Time tH 10 - ns
Data Output Delay Time tD - 120 ns
Data Hold Time tDH 5 - ns
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 10
BA TRON
BTHQ 42008VSS-01
10/11
Figure 2: Write Mode Timing Diagram
Figure 3: Read Mode Timing Diagram
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 11
BA TRON
BTHQ 42008VSS-01
5.3 Timing Diagram of VDD Against V0.
Power on sequence shall meet the requirement of Figure 4, the timing diagram of VDD against V0.
LOGIC SUPPLY
VOLTAGE
95%
11/11
VDD
0V
OV
LCD SUPPLY
VOLTAGE
50ms(typical)
V0
Figure 4: Timing Diagram of VDD Against V0.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.