Datasheet BTHQ 42003AV-07 Datasheet (BATRON)

Page 1
Specification for BTHQ 42003AV-SRE-06 W.C. (KS 0073)
BA TRON
Version June 2003
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
0
www.data-modul.de
Page 2
JUNE/2003
PAGE 2 OF 12
DOCUMENT REVISION HISTORY 1:
DOCUMENT
DATE DESCRIPTION CHANGED
REVISION
FROM TO
A 2003.06.20 First Release.
(Based on Test Specification: VL-TS-BTHQ 42003AV-XX, REV. D, 2003.05.27).
CHECKED
BY
BY
SUNNY LEE LU MIN
YUAN
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 3
JUNE/2003
PAGE 3 OF 12
CONTENTS
Page No.
1. GENERAL DESCRIPTION 4
2. MECHANICAL SPECIFICATIONS 4
3. INTERFACE SIGNALS 7
4. ABSOLUTE MAXIMUM RATINGS 8
4.1
ELECTRICAL MAXIMUM RATINGS (Ta=25qC)
4.2 ENVIRONMENTAL CONDITION 8
5. ELECTRICAL SPECIFICATIONS 9
5.1 TYPICAL ELECTRICAL CHARACTERISTICS 9
5.2 TIMING SPECIFICATIONS 10
6. CHARACTER GENERATOR ROM (KS0073-00) 12
8
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 4
JUNE/2003
PAGE 4 OF 12
Specification
of
LCD Module Type
Model No.: BTHQ 42003AV-07
1. General Description
x 20 characters(5x8 dots) x 4 lines STN Positive Reflective Yellow Dot Matrix LCD module. xViewing Angle: 6 O’clock direction. x Driving duty: 1/33 Duty, 1/5 bias. x SAMSUNG’ KS0073P-00CC (Die form) LCD Controller & Driver. x ‘SAMSUNG’ KS0065B-PCC (Die form) LCD Segment Driver or equivalent. x Temperature compensation. x Connector CON-16X1-35: 16 pins x 1 row, pitch=1.00mm, SMD
(“FULLCONN”, P/N:T03-2000-2160).
2. Mechanical Specifications
The mechanical detail is shown in Fig. 1 and summarized in Table 1 below.
Table 1
Parameter Specifications Unit Outline dimensions 65.0(W) x 28.4(H) x 9.0 MAX.(D) (Excluded connector) mm Viewing area 46.0(W) x 18.4(H) mm Display format 20 characters x 4 lines ­Character size 1.85(W) x 3.153(H) (5 x 8 dots) mm Character spacing 0.30(W) x 1.097(H) mm Character pitch 2.15(W) x 4.250(H) mm Dot size 0.358(W) x 0.381(H) mm Dot spacing 0.015(W) x 0.015(H) mm Dot pitch 0.373(W) x 0.396(H) mm Weight Approx. 16.0 grams
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 5
JUNE/2003
PAGE 5 OF 12
Figure 1: Outline Drawing
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 6
JUNE/2003
PAGE 6 OF 12
VSS
VDD
V0
RS
8
R/W
E
BTHQ 42003AV LCD DISPLAY
8
DB0~
DB7
LED(+)
LED(-)
8
LCD CONTROLLER/
DRIVER
'SAMSUNG'
KS0073P-00CC
(DIE FORM)
8
20 CHARACTERS (5 X 8 DOTS) X 4 LINES
8
60
40
LCD SEGMENT
DRIVER
'SAMSUNG'
KS0065B
(DIE FORM)
LED BACKLIGHT
(OPTIONAL)
Figure 2: Block Diagram
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 7
JUNE/2003
PAGE 7 OF 12
3. Interface signals
Table 2
Pin No. Symbol Description
1 VSS Ground (0V). 2 VDD Power supply for logic (+5.0V) 3 V0 Inputs voltage to the booster to generate the liquid crystal display
drive voltage. It is the reference voltage and power supply for the booster.
4 RS Register Select Input:
“High” for Data register (for read and write) “Low” for Instruction register (for write), Busy flag, address counter (for read)
5 R/W Read/Write signal:
‘High’ for Read mode. ‘Low’ for Write mode.
6 E Enable.
Start signal for data read /write. 7 DB0 Data input/output (LSB) 8 DB1 Data input/output 9 DB2 Data input/output
10 DB3 Data input/output 11 DB4 Data input/output 12 DB5 Data input/output 13 DB6 Data input/output 14 DB7 Data input/output (MSB) 15 LED(+) Anode of LED Backlight (Optional). 16 LED(-) Cathode of LED Backlight (Optional).
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 8
A H
V
H
(BTHQ 42003AV-SRE-06 W.C. (KS 0073))
JUNE/2003
PAGE 8 OF 12
4. Absolute Maximum Ratings
4.1 Electrical Maximum Ratings (Ta = 25 ºC)
Table 3
Parameter Symbol Min. Max. Unit Power Supply voltage (Logic) VDD - VSS -0.3 +7.0 V Power Supply voltage (LCD drive) VLCD -0.3 +15.0 V Input voltage Vin -0.3 VDD+0.3 V
Note:
The modules may be destroyed if they are used beyond the absolute maximum ratings.
All voltage values are referenced to VSS = 0V.
4.2 Environmental Condition
Table 4
Item
Operating
Temperature
(Topr)
Storage
Temperature
(Tstg)
Remark
Min. Max. Min. Max. mbient Temperature umidity
0q C +50qC -10qC +60qC
95% max. RH for Ta d 40qC
Dry no condensation
< 95% RH for Ta > 40qC
ibration (IEC 68-2-6)
cells must be mounted on a suitable connector
Shock (IEC 68-2-27)
alf-sine pulse shape
Frequency: 10 a 55 Hz
Amplitude: 0.75 mm Duration: 20 cycles in each direction. Pulse duration : 11 ms
Peak acceleration: 981 m/s2= 100g
3 directions
3 directions
Number of shocks : 3 shocks in 3 mutually perpendicular axes.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 9
JUNE/2003
PAGE 9 OF 12
5. Electrical Specifications
5.1 Typical Electrical Characteristics
At Ta = 25 qC, VDD = 5Vr5%, VSS=0V.
Table 5
Parameter Symbol Conditions Min. Typ. Max. Unit Supply voltage (Logic) VDD -VSS 4.75 5.0 5.25 V Supply voltage (LCD) (Built-in)
VLCD =VDD-V5
Ta =0 qC,
VDD = 5V, Note (1)
Ta = 25 qC
- 5.5 - V
4.9 5.3 5.7 V
VDD = 5V, Note (1)
Ta = 50 qC
- 5.0 - V
VDD = 5V, Note (1)
for E,DB0-DB7,R/W,RS
(Logic & LCD)
V
IH
V
IL
IDD
“High” level 0.7VDD - VDD V Input signal voltage “Low” level -0.3 - 0.6 V
Character mode,
- 2.3 3.5 mA Supply Current VDD = 5V Checker board mode,
- 2.3 3.5 mA VDD = 5V
Note (1) : There is tolerance in optimum LCD driving voltage during production and it will be within
the specified range.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 10
JUNE/2003
PAGE 10 OF 12
5.2 Timing Specifications
At Ta = 0qC To +50qC , VDD = +5Vr5%, VSS = 0V.
Refer to Fig. 3, the bus timing diagram for write mode.
Table 6
Parameter Symbol Min. Max. Unit E Cycle Time tC 500 - ns E Pulse Width (High, Low) tW 230 - ns E Rise time tR - 20 ns E Fall time tF - 20 ns R/W and RS Setup Time t
40 - ns
SU1
R/W and RS Hold Time tH1 10 - ns Data setup time t
60 - ns
SU2
Data hold time tH2 10 - ns
Figure 3: The bus timing diagram for write mode.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 11
JUNE/2003
PAGE 11 OF 12
Refer to Fig. 4, the bus timing diagram for read mode.
Table 7
Parameter Symbol Min. Max. Unit E Cycle Time tC 500 - ns E Pulse Width (High, Low) tW 230 - ns E Rise time tR - 20 ns E Fall time tF - 20 ns R/W and RS Setup Time tSU 40 - ns R/W and RS Hold Time tH 10 - ns Data Output Delay Time tD - 160 ns Data Hold Time tDH 5 - ns
Figure 4: The bus timing diagram for read mode.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
Page 12
JUNE/2003
PAGE 12 OF 12
6. Character Generator ROM (KS0073-00)