Datasheet BTA41-800BRG, BTA41-600BRG Specification

Page 1
A2
A1
G
A1
G
A2
A2
TOP3 Isolated
TOP3
A1
G
A2
RD91
G
A1
A2
BTA40, BTA41, BTB41
Datasheet
800 V and 600 V, 40 A standard Triacs in TOP3 and RD91 package
High current Triac
Low thermal resistance
BTA40 and BTA41 UL1557 recognized components (file ref: 81734)
RoHS (2002/95/EC) compliant packages
UL-94, V0 flammability package resin compliance
Applications
On/off function in static relays, heating regulation, induction motor starting circuits
Phase control operations in light dimmers and motor speed controllers
Product status link
BTA40 RD91 package
BTA41
TOP3 isolated
package
BTB41 TOP3 package
Product summary
I
T(RMS)
V
DRM/VRRM
I
GT
40 A
600 V to 800 V
50 mA
Description
Available in power packages, the BTA40, BTA41 and BTB41 are suitable for general purpose AC switching.
When used with the properly dimensioned heatsink, the BTA40, BTA41 and BTB41 can enable AC switching systems up to 9 kW. Refer to ST Application Note AN533 for thermal management of Triacs.
The BTA40, BTA41 and BTB41 provides an insulated tab (rated at 2500 V rms). They are recognized by UL. Representative samples of these components have been evaluated by UL and meet applicable UL requirements for UL 1557 standard (File Ref. 81734).
DS2111 - Rev 11 - March 2021 For further information contact your local STMicroelectronics sales office.
www.st.com
Page 2

1 Characteristics

Symbol Parameters Value Unit
I
T(RMS)
I
TSM
I2t I2t value for fusing
dl/dt
V
, V
DSM
I
GM
P
G(AV)
T
stg
T
RMS on-state current (180° conduction angle)
Non repetitive surge peak on-state current (full cycle, Tj initial = 25 °C)
Critical rate of rise of on-state current
IG = 2 x IGT , tr ≤ 100 ns
Non repetitive surge peak off-state voltage
RSM
Peak gate current
Average gate power dissipation
Storage junction temperature range -40 to +150 °C
Operating junction temperature range -40 to +125 °C
j
Table 1. Absolute maximum ratings
BTA40, BTA41
BTB41
tp = 10 ms
f = 120 Hz
tp = 20 ms Tj = 25 °C V
tp = 20 µs Tj = 125 °C
BTA40, BTA41, BTB41
Characteristics
Tc = 80 °C
Tc = 95 °C
tp = 16,7 ms
tp = 20 ms
Tj = 125 °C
Tj = 125 °C
40 A
420
400
1000
50 A/µs
, V
DRM
RRM
8 A
1 W
+ 100
A
A2s
V
Table 2. Electrical characteristics (Tj = 25 °C, unless otherwise specified) - standard (4 quadrants)
Symbol
(1)
I
GT
V
GT
V
GD
(2)
I
H
I
L
dV/dt
(dV/dt)c
VD = 12 V, RL = 33 Ω
VD = V
, RL = 3.3 kΩ, Tj = 125 °C
DRM
IT = 500 mA
IG = 1.2 I
(2)
VD = 67 % V
(2)
(dI/dt)c = 20 A/ms, Tj = 125 °C
GT
DRM
1. Minimum IGT is guaranteed at 5 % of IGT max.
2. For both polarities of A2 referenced to A1
Parameters Quadrant Values Unit
I - II - III
IV
Max.
100
I - II - III Max. 1.3 V
I - II - III Min. 0.2 V
Max. 80 mA
I - III - IV Max. 70
II Max. 160
gate open, Tj = 125 °C
Min. 500 V/µs
Min. 10 V/µs
Table 3. Static electrical characteristics
Symbol
(1)
V
TM
(1)
V
TO
(1)
R
D
I
DRM/IRRM
1. For both polarities of A2 referenced to A1
ITM = 60 A, tp = 380 µs
threshold on-state voltage 125 °C Max. 0.85 V
Dynamic resistance 125 °C Max. 10
VT = V
DRM
Test conditions
, VT = V
RRM
T
j
Value Unit
25 °C Max. 1.55 V
25 °C
125 °C 5 mA
Max.
5 µA
50
mA
mA
DS2111 - Rev 11
page 2/12
Page 3
BTA40, BTA41, BTB41
Characteristics
Table 4. Thermal resistance
Symbol Parameters Value Unit
R
R
th(j-c)
th(j-a)
Junction to case (AC)
Junction to ambient BTA40 / BTA41 / BTB41 50
BTA40 / BTA41 0.9
BTB41 0.6
°C/W
DS2111 - Rev 11
page 3/12
Page 4

1.1 Characteristics (curves)

0 5 10 15 20 25 30 35 40
0
10
20
30
40
50
P(W)
I
T(RMS)
(A)
180°
α
α
I
T(RMS)
(A)
0
5
10
15
20
25
30
35
40
45
0 25 50 75 100 125
α=180°
BTA40 BTA41
BTB41
TC(°C)
E-031. 1.E-02 E-011. E+001. E+011. E+021. E+031.
E-031.
E-021.
E-011.
E+001.
K=[Zth/R
th
]
t
p
(s)
Z
th(j-a)
BTA / BTB41
Z
th(j-c)
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
1
10
100
400
ITM(A)
V
TM
(V)
Tj= 25°C.
T max.
V = 0.85V
j
to
R = 10 mdΩ
j
T = Tjmax.
1 10010 1000
0
50
100
150
200
250
300
350
400
450
I
TSM
(A)
Number of cycles
t=20ms
One cycle
Non repetitive Tjinitial=25°C
Repetitive
T
C
=70°C
0.01 0.10 1.00 10.00
100
1000
10000
I
TSM
(A), I²t (A²s)
tp(ms)
Pulse width tp < 10 ms
j
T initial=25 °C
I
TSM
dI/dt limitation:
50A/µs
BTA40, BTA41, BTB41
Characteristics (curves)
Figure 1. Maximum power dissipation versus on-state
RMS current (full cycle)
Figure 3. Relative variation of thermal impedance versus
pulse duration
Figure 2. RMS on-state current versus case temperature
(full cycle)
Figure 4. On-state characteristics (maximum values)
Figure 5. Surge peak on-state current versus number of
cycles
DS2111 - Rev 11
Figure 6. Non-repetitive surge peak on-state current for a
sinusoidal pulse
page 4/12
Page 5
-40 -20 0 20 40 60 80 100 120 140
0.0
0.5
1.0
1.5
2.0
2.5
Tj(°C)
I
GT
IH& I
L
GT
I ,HI ,LI [jT ] / IGT,IH,IL[Tj=25°C]
Typical values
0.1 1.0 10.0 100.0
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
(dV/dt)c (V/µs)
(dI/dt)c [(dV/dt)c] / specified (dI/dt)c
0 25 50 75 100 125
0
1
2
3
4
5
6
(dI/dt)c [Tj] / (dI/dt)c [Tjspecified]
Tj(°C)
BTA40, BTA41, BTB41
Characteristics (curves)
Figure 7. Relative variation of gate trigger current, holding
and latching current versus junction temperature
Figure 9.
Relative variation of critical rate of decrease of main current versus junction temperature
Figure 8. Relative variation of critical rate of decrease of
main current versus (dV/dt)c (typical values)
(typical values)
DS2111 - Rev 11
page 5/12
Page 6

2 Package information

In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK packages, depending on their level of environmental compliance. ECOPACK specifications, grade definitions and product status are available at: www.st.com. ECOPACK is an ST trademark.

2.1 TOP3 insulated and non-insulated package information

Epoxy meets UL94, V0
Lead-free packages
Recommended torque: 1.05 N·m (max. torque: 1.2 N·m)
Figure 10. TOP3 insulated and non-insulated package outline
BTA40, BTA41, BTB41
Package information
DS2111 - Rev 11
page 6/12
Page 7
BTA40, BTA41, BTB41
TOP3 insulated and non-insulated package information
Table 5. TOP3 insulated and non-insulated mechanical data
Dimensions
Ref.
mm
Min. Typ. Max. Min. Typ. Max.
A
4.40 4.60 0.1732 0.1812
B 1.45 1.55 0.0570 0.0611
C 14.35 15.60 0.5649 0.6142
D 0.50 0.70 0.0196 0.0276
E 2.70 2.90 0.1062 0.1142
F 15.80 16.50 0.6220 0.6497
G 20.40 21.10 0.8031 0.8308
H 15.10 15.50 0.5944 0.6103
J 5.40 5.65 0.2125 0.2225
K 3.40 3.65 0.1338 0.1438
L 4.08 4.17 0.1606 0.1642
M 1.20 1.40 0.0472 0.0552
R 4.60 0.1811
1. Inches given for reference only
Inches
(1)
DS2111 - Rev 11
page 7/12
Page 8

2.2 RD91 package information

A
E 3
N2
N1
B
F
I
A1
B 1
L1
A2
L2
B 2
C
C2 C1
E
E2
Epoxy meets UL94, V0
Cooling method: Conduction
Recommended torque: 0.9 to 1.2 N·m
BTA40, BTA41, BTB41
RD91 package information
Figure 11. RD91 package outline
DS2111 - Rev 11
page 8/12
Page 9
BTA40, BTA41, BTB41
RD91 package information
Table 6. RD91 mechanical data
Dimensions
Ref.
mm
Min. Typ. Max. Min. Typ. Max.
A
40.00 1.575
A1 30.10 30.30 1.185 1.193
A2 22.00 0.867
B 27.00 1.063
B1 13.50 16.50 0.531 0.650
B2 24.00 0.945
C 14.00 0.552
C1 3.50 0.138
C2 1.90 2.10 0.074 0.083
E 6.10 6.50 0.240 0.256
E2 4.80 5.20 0.188 0.205
E3 0.70 0.90 0.027 0.036
F 4.00 4.30 0.157 0.170
I 11.20 11.60 0.440 0.536
L1 3.10 3.50 0.122 0.138
L2 1.70 1.90 0.066 0.075
N1 33° 43° 33° 43°
N2 28° 38° 28° 38°
1. Inches given for reference only
Inches
(1)
DS2111 - Rev 11
page 9/12
Page 10

3 Ordering information

BT A 40 - 600 B RG
Triac series
Insulation A = Insulated B = Non-insulated
Current
40 = 40 A in RD91 41 = 40 A in TOP3 or TOP3 insulated
Package
Voltage 600 = 600 V
Blank = Bulk
RG = Tube
800 = 800 V Sensitive and type
B = 50 mA standard
Figure 12. Ordering information scheme (BTA40, BTA41 and BTB-41 series)
BTA40, BTA41, BTB41
Ordering information
Order code
BTA40-600B BTA40600B RD91 20 g 25 Bulk
BTA40-800B BTA40800B RD91 20 g 25 Bulk
BTA41-600BRG BTA41600B TOP3 Ins. 4.5 g 30 Tube
BTA41-800BRG BTA41800B TOP3 Ins. 4.5 g 30 Tube
BTB41-600BRG BTB41600B TOP3 4.5 g 30 Tube
BTB41-800BRG BTB41800B TOP3 4.5 g 30 Tube
Marking Package Weight Base qty. Delivery mode
Table 7. Ordering information
DS2111 - Rev 11
page 10/12
Page 11

Revision history

BTA40, BTA41, BTB41
Table 8. Document revision history
Date Revision Changes
Sep-2003 5 Last update.
25-Mar-2005 6 TOP3 delivery mode changed from bulk to tube.
14-Oct-2005 7
10-Aug-2009 8
02-Dec-2020 9
28-Jan-2021 10 Updated Table 1 and Table 4.
24-Mar-2021 11 Updated coverimage.
Tc values for IT changed in Table 3. ECOPACK statement added.
Updated Table 2 to correctly place packages. Updated Figure 2. Table 5 changed to correctly place TOP3.
Updated ECOPACK statement.
Updated Figure 6 and Figure 12. Added Application section. Minor text change.
DS2111 - Rev 11
page 11/12
Page 12
BTA40, BTA41, BTB41
IMPORTANT NOTICE – PLEASE READ CAREFULLY
STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at the time of order acknowledgement.
Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or the design of Purchasers’ products.
No license, express or implied, to any intellectual property right is granted by ST herein.
Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product.
ST and the ST logo are trademarks of ST. For additional information about ST trademarks, please refer to www.st.com/trademarks. All other product or service names are the property of their respective owners.
Information in this document supersedes and replaces information previously supplied in any prior versions of this document.
© 2021 STMicroelectronics – All rights reserved
DS2111 - Rev 11
page 12/12
Loading...