Philips Semiconductors Preliminary specification
Three quadrant triacs BTA216B series C high commutation
GENERAL DESCRIPTION QUICK REFERENCE DATA
Glass passivated high commutation SYMBOL PARAMETER MAX. MAX. MAX. UNIT triacsinaplastic envelopesuitablefor surface mounting, intended for use in BTA216B- 500C 600C 800C circuitswherehighstaticanddynamic V
Repetitive peak off-state 500 600 800 V dV/dtand high dI/dt can occur. These voltages devices will commutate the full rated I
T(RMS)
RMS on-state current 16 16 16 A rms current at the maximum rated I
TSM
Non-repetitive peak on-state 140 140 140 A junction temperature, without the aid current of a snubber.
PINNING - SOT404 PIN CONFIGURATION SYMBOL
PIN DESCRIPTION
1 main terminal 1 2 main terminal 2 3 gate
mb main terminal 2
LIMITING VALUES
Limiting values in accordance with the Absolute Maximum System (IEC 134).
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
-500 -600 -800
V
Repetitive peak off-state - 500
1
600
1
800 V
voltages
I
T(RMS)
RMS on-state current full sine wave; - 16 A
Tmb 99 ˚C
I
TSM
Non-repetitive peak full sine wave; on-state current Tj = 25 ˚C prior to
surge t = 20 ms - 140 A t = 16.7 ms - 150 A
I2tI
2
t for fusing t = 10 ms - 98 A2s
dIT/dt Repetitive rate of rise of ITM = 20 A; IG = 0.2 A; 100 A/µs
on-state current after dIG/dt = 0.2 A/µs triggering
I
GM
Peak gate current - 2 A
V
GM
Peak gate voltage - 5 V
P
GM
Peak gate power - 5 W
P
G(AV)
Average gate power over any 20 ms - 0.5 W
period
T
stg
Storage temperature -40 150 ˚C
T
j
Operating junction - 125 ˚C temperature
13
mb
2
T1T2
G
1 Although not recommended, off-state voltages up to 800V may be applied without damage, but the triac may switch to the on-state. The rate of rise of current should not exceed 15 A/µs.
October 1997 1 Rev 1.000
Page 2
Philips Semiconductors Preliminary specification
Three quadrant triacs BTA216B series C high commutation
THERMAL RESISTANCES
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
R
th j-mb
Thermal resistance full cycle - - 1.2 K/W junction to mounting base half cycle - - 1.7 K/W
R
th j-a
Thermal resistance minimum footprint, FR4 board - 55 - K/W junction to ambient
STATIC CHARACTERISTICS
Tj = 25 ˚C unless otherwise stated
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
I
GT
Gate trigger current
2
VD = 12 V; IT = 0.1 A
T2+ G+ 2 18 35 mA T2+ G- 2 21 35 mA T2- G- 2 34 35 mA
I
L
Latching current VD = 12 V; IGT = 0.1 A
T2+ G+ - - 20 mA T2+ G- - - 30 mA T2- G- - - 20 mA
I
H
Holding current VD = 12 V; IGT = 0.1 A - - 15 mA
V
T
On-state voltage IT = 20 A - 1.2 1.5 V
V
GT
Gate trigger voltage VD = 12 V; IT = 0.1 A - 0.7 1.5 V
VD = 400 V; IT = 0.1 A; Tj = 125 ˚C 0.25 0.4 - V
I
D
Off-state leakage current VD = V
DRM(max)
; Tj = 125 ˚C - 0.1 0.5 mA
DYNAMIC CHARACTERISTICS
Tj = 25 ˚C unless otherwise stated
SYMBOL PARAMETER CONDITIONS MIN. TYP. UNIT
dVD/dt Critical rate of rise of VDM = 67% V
DRM(max)
; Tj = 125 ˚C; exponential 1000 - V/µs
off-state voltage waveform; gate open circuit
dI
com
/dt Critical rate of change of VDM = 400 V; Tj = 125 ˚C; I
T(RMS)
= 16 A; without 3 14 A/ms
commutating current snubber; gate open circuit
t
gt
Gate controlled turn-on ITM = 20 A; VD = V
DRM(max)
; IG = 0.1 A; - 2 µs
time dIG/dt = 5 A/µs
2 Device does not trigger in the T2-, G+ quadrant.
October 1997 2 Rev 1.000
Page 3
Philips Semiconductors Preliminary specification
Three quadrant triacs BTA216B series C high commutation
MECHANICAL DATA
Dimensions in mm Net Mass: 1.4 g
Fig.1. SOT404 : centre pin connected to mounting base.
Notes
1. Epoxy meets UL94 V0 at 1/8".
MOUNTING INSTRUCTIONS
Dimensions in mm
Fig.2. SOT404 : minimum pad sizes for surface mounting
.
Notes
1. Plastic meets UL94 V0 at 1/8".
11 max
4.5 max
1.4 max
10.3 max
0.5
15.4
2.5
0.85 max (x2)
2.54 (x2)
17.5
11.5
9.0
5.08
3.8
2.0
October 1997 3 Rev 1.000
Page 4
Philips Semiconductors Preliminary specification
Three quadrant triacs BTA216B series C high commutation
DEFINITIONS
Data sheet status
Objective specification This data sheet contains target or goal specifications for product development. Preliminary specification This data sheet contains preliminary data; supplementary data may be published later. Product specification This data sheet contains final product specifications.
Limiting values
Limiting values are given in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of this specification is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
Philips Electronics N.V. 1997
All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner.
The information presented in this document does not form part of any quotation or contract, it is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights.
LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.