Glass passivated triacs in a plasticSYMBOLPARAMETERMAX. MAX. MAX. UNIT
envelope,intendedforusein
applications requiringhigh noiseBT139-500H600H800H
immunityinadditiontohigh,V
on-state current afterdIG/dt = 0.2 A/µs
triggeringT2+ G+-50A/µs
I
V
P
P
T
T
GM
GM
GM
G(AV)
stg
j
Peak gate current-2A
Peak gate voltage-5V
Peak gate power-5W
Average gate powerover any 20 ms period-0.5W
Storage temperature-40150˚C
Operating junction-125˚C
temperature
-500-600-800
T2+ G--50A/µs
T2- G--50A/µs
T2- G+-10A/µs
1
800V
T1T2
1 Although not recommended, off-state voltages up to 800V may be applied without damage, but the triac may
switch to the on-state. The rate of rise of current should not exceed 15 A/µs.
September 19971Rev 1.200
Page 2
Philips SemiconductorsProduct specification
TriacsBT139 series H
high noise immunity
THERMAL RESISTANCES
SYMBOLPARAMETERCONDITIONSMIN.TYP.MAX.UNIT
R
th j-mb
R
th j-a
STATIC CHARACTERISTICS
Tj = 25 ˚C unless otherwise stated
SYMBOLPARAMETERCONDITIONSMIN.TYP.MAX.UNIT
I
GT
I
L
I
H
V
T
V
GT
I
D
Thermal resistancefull cycle--1.2K/W
junction to mounting base half cycle--1.7K/W
Thermal resistancein free air-60-K/W
junction to ambient
Fig.5. Maximum permissible repetitive rms on-state
current I
, versus surge duration, for sinusoidal
T(RMS)
currents, f = 50 Hz; Tmb ≤ 99˚C.
ITSM / A
150
100
50
0
1101001000
BT139
I
T
Tj initial = 25 C max
Number of cycles at 50Hz
I
TSM
time
T
Fig.3. Maximum permissible non-repetitive peak
on-state current I
sinusoidal currents, f = 50 Hz.
, versus number of cycles, for
TSM
VGT(Tj)
VGT(25 C)
1.6
1.4
1.2
1
0.8
0.6
0.4
-50050100150
BT136
Tj / C
Fig.6. Normalised gate trigger voltage
VGT(Tj)/ VGT(25˚C), versus junction temperature Tj.
September 19973Rev 1.200
Page 4
Philips SemiconductorsProduct specification
TriacsBT139 series H
high noise immunity
IGT(Tj)
IGT(25 C)
3
2.5
2
1.5
1
0.5
0
-50050100150
BT139H
Tj / C
T2+ G+
T2+ GT2- GT2- G+
Fig.7. Normalised gate trigger current
IGT(Tj)/ IGT(25˚C), versus junction temperature T
IL(Tj)
2.5
1.5
0.5
IL(25 C)
3
2
1
TRIAC
IT / A
50
Tj = 125 C
Tj = 25 C
40
Vo = 1.195 V
Rs = 0.018 Ohms
30
20
10
0
00.511.522.53
BT139
typmax
VT / V
Fig.10. Typical and maximum on-state characteristic.
.
j
Zth j-mb (K/W)
10
1
0.1
0.01
BT139
unidirectional
bidirectional
t
P
p
D
t
0
-50050100150
Tj / C
Fig.8. Normalised latching current IL(Tj)/ IL(25˚C),
versus junction temperature T
IH(Tj)
IH(25C)
3
2.5
2
1.5
1
0.5
0
-50050100150
TRIAC
Tj / C
.
j
Fig.9. Normalised holding current IH(Tj)/ IH(25˚C),
versus junction temperature T
.
j
0.001
10us0.1ms1ms10ms0.1s1s10s
Fig.11. Transient thermal impedance Z
dV/dt (V/us)
1000
100
dIcom/dt =
20 A/ms
10
1
050100150
tp / s
pulse width tp.
16
9.3
127.2
Tj / C
, versus
th j-mb
off-state dV/dt limit
BT139...H SERIES
5.6
Fig.12. Typical commutation dV/dt versus junction
temperature, parameter commutation dIT/dt. The triac
should commutate when the dV/dt is below the value
on the appropriate curve for pre-commutation dIT/dt.
September 19974Rev 1.200
Page 5
Philips SemiconductorsProduct specification
TriacsBT139 series H
high noise immunity
MECHANICAL DATA
Dimensions in mm
Net Mass: 2 g
10,3
max
1,3
3,7
4,5
max
3,0 max
not tinned
1,3
max
(2x)
123
2,54 2,54
2,8
3,0
13,5
min
0,9 max (3x)
5,9
min
15,8
max
0,6
2,4
Fig.13. TO220AB; pin 2 connected to mounting base.
Notes
1. Refer to mounting instructions for TO220 envelopes.
2. Epoxy meets UL94 V0 at 1/8".
September 19975Rev 1.200
Page 6
Philips SemiconductorsProduct specification
TriacsBT139 series H
high noise immunity
DEFINITIONS
Data sheet status
Objective specificationThis data sheet contains target or goal specifications for product development.
Preliminary specification This data sheet contains preliminary data; supplementary data may be published later.
Product specificationThis data sheet contains final product specifications.
Limiting values
Limiting values are given in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one
or more of the limiting values may cause permanent damage to the device. These are stress ratings only and
operation of the device at these or at any other conditions above those given in the Characteristics sections of
this specification is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
Philips Electronics N.V. 1997
All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the
copyright owner.
The information presented in this document does not form part of any quotation or contract, it is believed to be
accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any
consequence of its use. Publication thereof does not convey nor imply any license under patent or other
industrial or intellectual property rights.
LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices or systems where malfunction of these
products can be reasonably expected to result in personal injury. Philips customers using or selling these products
for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting
from such improper use or sale.
September 19976Rev 1.200
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.