Datasheet BR100-03 Datasheet (Philips)

Page 1
Philips Semiconductors Product Specification
Silicon Bi-directional Trigger Device BR100/03 LLD
GENERAL DESCRIPTION QUICK REFERENCE DATA
Siliconbidirectionaltrigger device in a SYMBOL PARAMETER MIN. MAX. UNIT glass envelope suitable for surface mounting. The device is intended for V
(BO)
use in triac and thyristor trigger V
O
circuits. I
FRM
Repetitive peak forward current - 2 A
OUTLINE - SOD80 SYMBOL
LIMITING VALUES
Limiting values in accordance with the Absolute Maximum System (IEC 134).
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
I
FRM
Repetitive peak forward t 10 µs, Ttp 50˚C; f = 60 Hz - 2 A current
P
tot
Total power dissipation Ttp = 50˚C - 150 mW
T
stg
Storage temperature -55 125 ˚C
T
j
Operating junction - 100 ˚C temperature
THERMAL RESISTANCES
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
R
th j-tp
Thermal resistance junction to PCB mounted - 330 - K/W tie point
CHARACTERISTICS
Ta = 25 ˚C unless otherwise stated.
SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
V
(BO)
Breakover voltage I = I
(BO)
28 32 36 V
|V
(BO)+
| - |V
(BO)-
| Breakover voltage symmetry I = I
(BO)
, see fig: 1 - - 3.5 V
V
O
Output voltage RL = 20 ; Circuit of fig: 2 7 - - V
I
(BO)
Breakover current V = V
(BO)
--50µA
dV
(BO)
/dT Temperature coefficient of - 0.1 - %/K
V
(BO)
t
r
Risetime Ip = 0.5 A; Circuit of fig: 2 - 1.5 µs
February 1996 1 Rev 1.000
Page 2
Philips Semiconductors Product Specification
Silicon Bi-directional Trigger Device BR100/03 LLD
Fig.1. Current-voltage characteristics Fig.2. Test circuit for output voltage and risetime.
MECHANICAL DATA
Dimensions in mm
Fig.3. SOD80
I
V
V(BO)I
I(BO)I
I(BO)III
V(BO)III
230 V, RMS, 50Hz
100nF
10k
D.U.T.
500k
50R
VBO
IT
Adjust for Ip=0.5A
Vo
when measuring risetime
10R
Set load resistance measuring output voltage
to 20 Ohms when
0.3 min
0 1.5 max
1.3
0 1.5
3.3
3.7
February 1996 2 Rev 1.000
Page 3
Philips Semiconductors Product Specification
Silicon Bi-directional Trigger Device BR100/03 LLD
DEFINITIONS
Data sheet status
Objective specification This data sheet contains target or goal specifications for product development. Preliminary specification This data sheet contains preliminary data; supplementary data may be published later. Product specification This data sheet contains final product specifications.
Limiting values
Limiting values are given in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of this specification is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
Philips Electronics N.V. 1996
All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner.
The information presented in this document does not form part of any quotation or contract, it is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights.
LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.
February 1996 3 Rev 1.000
Loading...