Datasheet BCR6AM-8L, BCR6AM-12L, BCR6AM-12 Datasheet (POWEREX)

Page 1
Dimensions Inches Millimeters
J 0.99 2.54 K 0.10 2.6 L 0.051 Min. 1.3 M 0.051 1.3 N 0.039 1.0 P 0.031 0.8 Q 0.020 0.5
Dimensions Inches Millimeters
Description:
A triac is a solid state silicon AC switch which may be gate triggered from an off-state to an on-state for either polarity of applied voltage.
Features:
Glass PassivationSelected for Inductive Loads
Applications:
AC SwitchHeatingMotor ControlsLightingSolid State RelayCopying MachineSwitch Mode Power Supply
Ordering Information:
Example: Select the complete seven, eight or nine digit part number you desire from the table - i.e.BCR6AM-8 is a 400 Volt, 6 Ampere Triac
V
DRM
Inductive
Type Volts Code Load*
BCR6AM 400 -8 L
600 -12
*For inductive load, add L.
Powerex,Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
Triac
6 Amperes/400-600 Volts
BCR6AM
Outline Drawing (Conforms to TO-220)
T-27
➁➃
BG
D
A
H
L
E
K
M
N
JJ
P
B
F
E
C
T1 TERMINALT2 TERMINALGATE ➃ T2 TERMINAL
CONNECTION DIAGRAM
OUTLINE DRAWING
Page 2
Absolute Maximum Ratings, T
a
= 25 °C unless otherwise specified
Ratings Symbol BCR6AM-8 BCR6AM-12 Units
Repetitive Peak Off-state Voltage V
DRM
400 600 Volts
Non-repetitive Peak Off-state Voltage V
DSM
500 720 Volts
On-state Current, Tc= 103°C I
T(RMS)
6 6 Amperes
Non-repetitive Peak Surge, One Cycle (60 Hz) I
TSM
60 60 Amperes I2t for Fusing, t = 8.3 msec I2t 15 15 A2sec Peak Gate Power Dissipation, 20 msec P
GM
5 5 Watts
Average Gate Power Dissipation P
G(avg)
0.5 0.5 Watts
Peak Gate Current I
GM
2 2 Amperes
Peak Gate Voltage V
GM
10 10 Volts Storage Temperature T
stg
-40 to 125 -40 to 125 °C
Operating Temperature T
j
-40 to 125 -40 to 125 °C
Weight 2.3 2.3 Grams
Powerex,Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR6AM Triac
6 Amperes/400-600 Volts
T-28
Page 3
Powerex,Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR6AM Triac
6 Amperes/400-600 Volts
T-29
Electrical and Thermal Characteristics, T
j
= 25 °C unless otherwise specified
Test Conditions (Trigger Mode) BCR6AM
Characteristics Symbol V
D
R
L
R
G
T
j
Min. Typ. Max. Units
Gate Parameters DC Gate Trigger Current
MT2+ Gate+ 6V 6V 330V 25°C 30 mA MT2+ Gate– I
GT
6V 6V 330V 25°C 30 mA
MT2– Gate– 6V 6V 330V 25°C 30 mA
DC Gate Trigger Voltage
MT2+ Gate+ 6V 6V 330V 25°C 1.5 Volts MT2+ Gate– V
GT
6V 6V 330V 25°C 1.5 Volts
MT2– Gate– 6V 6V 330V 25°C 1.5 Volts
DC Gate Non-tr igger Voltage
All V
GD
1/2 V
DRM
125°C 0.2 Volts
Page 4
Powerex,Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR6AM Triac
6 Amperes/400-600 Volts
T-30
Electrical and Thermal Characteristics, T
j
= 25 °C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Thermal Resistance, Junction-to-case R
th(j-c)
2.5 °C/W
Voltage – Blocking State I
DRM
Gate Open Circuited, 2 mA
Repetitive Off-state Current VD= V
DRM
, Tj= 125°C
Current – Conducting State V
TM
Tc= 25°C, 1.7 Volts
Peak On-state Voltage ITM= 9A Peak
Critical Rate-of-rise of Commutating (dv/dt)
c
V/ms Off-state Voltage (Commutating dv/dt) for inductive load (L) (Switching)
Commutating
dv/dt, (dv/dt)
c
Commutating Voltage &
D Part V
DRM
(V/msec) Current Waveform
Number (Volts) Minimum Test Condition (Inductive Load)
BCR6AM-8L 400 10 Tj= 125°C, BCR6AM-12L 400 10 Rate of Decay
On-state
Commutating Current
(di/dt)c= -3A/msec:
Peak Off-state
Voltage
VD= 400V
SUPPLY VOLTAGE
(di/dt)
C
(dv/dt)
C
V
D
V
D
MAIN CURRENT
MAIN VOLTAGE
t
t
t
Page 5
Powerex,Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR6AM Triac
6 Amperes/400-600 Volts
0.6
1.4
2.2
3.0
3.8
4.6
MAXIMUM ON-STATE
CHARACTERISTICS
INSTANTANEOUS ON-STATE CURRENT, IT, (AMPERES)
INSTANTANEOUS ON-STATE VOLTAGE, V
T
, (VOLTS)
10
-1
10
0
10
1
10
2
Tj = 25oC
0
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(JUNCTION-TO-CASE)
CYCLES AT 60 Hz
TRANSIENT THERMAL IMPEDANCE, Z
th(j-c)
, (°C/WATT)
10
-1
10
0
10
2
10
3
10
1
10
2
0.4
0.8
1.2
1.6
2.0
2.4
2.8
3.2
10
-1
10
2
10
1
10
0
GATE CHARACTERISTICS
(I, II, III)
GATE CURRENT, IG, (mA)
GATE VOLTAGE, V
G
, (VOLTS)
10
2
10
1
10
3
10
4
V
GD
= 0.2V
V
GM
= 10V
V
GT
= 1.5V
I
GM
= 2A
P
GM
= 5W
P
G(avg)
= 0.5W
I
RGT I,
I
FGT I,
I
RGT III
0
20
40
60
80
100
MAXIMUM SURGE CURRENT
FOLLOWING RATED LOAD CONDITIONS
CYCLES AT 60 Hz
MAXIMUM PEAK SURGE CURRENT, I
TSM
, (AMPERES)
10
0
10
1
10
2
0
20
40
60
80
100
120
140
160
ALLOWABLE CASE TEMPERATURE
VS. RMS ON-STATE CURRENT
RMS ON-STATE CURRENT, I
T(RMS)
, (AMPERES)
CASE TEMPERATURE, T
C
, (°C)
0 2 4 6 8 107531 9
FOR AC CONTROL THIS GRAPH NEARLY APPLIES REGARDLESS OF THE CONDUCTION ANGLE
CONDUCTION
RESISTIVE, INDUCTIVE
LOADS
GATE TRIGGER CURRENT
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, Tj, (°C)
GATE TRIGGER CURRENT, (t°C)
GATE TRIGGER CURRENT, (25°C)
x 100%
-60 -20 20 60 100 140-40 0 40 80 120
10
1
10
2
10
3
I
RGT I, IRGT III
I
FGT I,
0 2 4 6 8 107531 9
0
20
40
60
80
100
120
140
160
ALLOWABLE AMBIENT TEMPERATURE
VS. RMS ON-STATE CURRENT
RMS ON-STATE CURRENT, I
T(RMS)
, (AMPERES)
AMBIENT TEMPERATURE, T
a
, (°C)
60 x 60 x t 2.3 100 x 100 x t 2.3 120 x 120 x t 2.3
NATURAL CONVECTION CURVES APPLY REGARDLESS OF THE CONDUCTION ANGLE RESISTIVE, INDUCTIVE LOADS
0
20
40
60
80
100
120
140
160
ALLOWABLE AMBIENT TEMPERATURE
VS. RMS ON-STATE CURRENT
RMS ON-STATE CURRENT, I
T(RMS)
, (AMPERES)
AMBIENT TEMPERATURE, T
a
, (°C)
NATURAL CONVECTION, NO FIN CURVES APPLY REGARDLESS OF THE CONDUCTION ANGLE RESISTIVE, INDUCTIVE LOADS
0 0.8 1.6 2.4 3.22.0 2.81.20.4 0 2 4 6 8 107531 9
MAXIMUM ON-STATE POWER DISSIPATION
RMS ON-STATE CURRENT, I
T(RMS)
, (AMPERES)
MAXIMUM POWER DISSIPATION, (WATTS)
360° CONDUCTION RESISTIVE, INDUCTIVE LOADS
0
20 18 16 14 12 10
8 6 4 2
360°
T-31
Page 6
Powerex,Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR6AM Triac
6 Amperes/400-600 Volts
GATE TRIGGER VOLTAGE
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, Tj, (°C)
GATE TRIGGER VOLTAGE, (t°C)
GATE TRIGGER VOLTAGE, (25°C)
x 100%
-60 -20 20 60 100 140-40 0 40 80 120
10
1
10
2
10
3
BREAKOVER VOLTAGE VS.
RATE OF RISE OF OFF-STATE VOLTAGE
(TYPICAL)
RATE OF RISE OF OFF-STATE VOLTAGE, dv/dt, (V/ms)
0
20
40
60
80
100
120
140
160
BREAKOVER VOLTAGE, (dv/dt = x V/ms)
BREAKOVER VOLTAGE, (dv/dt = 1V/ms)
x 100%
10
2
10
1
10
3
10
4
Tj = 125°C
I QUADRANT III QUADRANT
REPETITIVE PEAK OFF-STATE CURRENT
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, Tj, (°C)
-60 -20 20 60 100 140-40 0 40 80 120
10
2
10
3
10
4
10
5
REPETITIVE PEAK OFF-STATE CURRENT, (t°C)
REPETITIVE PEAK OFF-STATE CURRENT, (25°C)
x 100%
GATE TRIGGER CURRENT
VS. GATE CURRENT PULSE WIDTH
(TYPICAL)
GATE CURRENT PULSE WIDTH, tw, (ms)
GATE TRIGGER CURRENT, (t
w
)
GATE TRIGGER CURRENT, (DC)
x 100%
10
1
10
2
10
3
Tj = 25°C
10
0
10
1
10
2
I
FGT I
I
RGT III
I
RGT I
HOLDING CURRENT
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, Tj, (°C)
HOLDING CURRENT, I
H
, (mA)
-60 -20 20 60 100 140-40 0 40 80 120
10
1
10
2
10
3
BREAKOVER VOLTAGE
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, Tj, (°C)
-60 -20 20 60 100 140-40 0 40 80 120
0
20
40
60
80
100
120
140
160
BREAKOVER VOLTAGE, (t°C)
BREAKOVER VOLTAGE, (25°C)
x 100%
COMMUTATION CHARACTERISTICS
(TYPICAL)
RATE OF DECAY OF ON-STATE
COMMUTATING CURRENT, (A/ms)
10
0
10
1
10
2
10
0
10
1
10
2
CRITICAL RATE OF RISE OF
OFF-STATE COMMUTATING VOLTAGE, (V/ms)
Tj = 125oC I
T
= 4A
t
= 500ms
V
D
= 200v
f = 3Hz
MINIMUM CHARACTERISTICS VALUE
III QUADRANT
I QUADRANT
GATE TRIGGER CHARACTERISTICS
TEST CIRCUITS
TEST PROCEDURE I TEST PROCEDURE II
R
G
6V
6V
A
V
R
G
6V
6V
TEST PROCEDURE III
A
V
R
G
6V
6V
A
V
T-32
Loading...