Remote Local
SW1 A (1) ON OFF
SW1 B (2) ON OFF
SW1 C (3) OFF ON
SW1 D (4) OFF ON
Mechanical Details
Examples of parallel operation
Current and Voltage balance pins are used to connect units in parallel - see drawing.
Remote on/off: Output is on with pin left floating, pull pin down to -Output to turn
output off.
Temp Warning: When baseplate is in normal temperature range, output is 5 V
typical; goes low, (0.5 V @ 5 mA), when baseplate exceeds safe level.
Remote sense pins are used to compensate for lead drops. For up to 0.5 V max.
When not used, move switch SW1 to local positions. See below for switch positions.
The BCC series is approximately 80% efficient so for 400 W load consumption,
the cooling system used will have to be able to absorb 100 W while maintaining the
baseplate to a maximum of +83 °C.
Output:
Power output +ve and -ve by M6 studs.
Use appropriate ring terminals and wire for the load current.
Signal connections on two 0.1" headers (PL3 & PL4).
Mating Housing: Molex 22-01-2065.
Mating Crimp: Molex 08-50-0032.
Input:
AMP Mat'n'lok 3 way.
Mating housing AMP 350766-1.
Socket crimp AMP 926893-1.
Pin 1: Live
Pin 2: Earth
Pin 3: Neutral
Output Output Output Output Load Model
Power Voltage Current Regulation Number
165 W 3.3 V 50.0 A 1.5% BCC200PS03
200 W 5.0 V 40.0 A 1.5% BCC200PS05
210 W 7.5 V 28.0 A 1.5% BCC200PS07
240 W 12.0 V 20.0 A 1.5% BCC200PS12
264 W 3.3 V 80.0 A 1.5% BCC400PS03
400 W 5.0 V 80.0 A 1.5% BCC400PS05
405 W 7.5 V 54.0 A 1.5% BCC400PS07
408 W 12.0 V 34.0 A 1.0% BCC400PS12
405 W 15.0 V 27.0 A 1.0% BCC400PS15
396 W 18.0 V 22.0 A 1.0% BCC400PS18
408 W 24.0 V 17.0 A 1.0% BCC400PS24
406 W 28.0 V 14.5 A 1.0% BCC400PS28
OUTPUT VOLTAGE & CURRENT RATINGS BCC
Remote Sense Switchers
Application Notes
Contact sales office for a full
set of Application Notes.
Accessories
1. For Input and Output Connector Kit - order part ‘BCC connector kit’.
2. For Thermal Pad, order part ‘BCC Therm’.
PL3 Connections
Pin Function
1 Current Balance
2 Voltage Balance
3 Trim
4 -Remote Sense
5 +Remote Sense
6 Remote on/off
PL4 Connections
Pin Function
1 Current Balance
2 Voltage Balance
3 Trim
4 -Remote Sense
5 +Remote Sense
6 Temp Warning
1. For -40 °C operating temperature, add suffix ‘L’ to model number.
2. For conformally coated option, add suffix ‘E’ to model number.
3. Part numbers in bold are standard stock models, all others are build to order.
Notes
•
* Preliminary datasheet - see website for current specs
PH: 508 429.9883
FAX: 800 226.2100
Holliston, MA 01746 USA
www.XPiQ.com
BCC.qxd 6/6/03 3:27 pm Page 2