Datasheet BAX18 Datasheet (Philips)

Page 1
DISCRETE SEMICONDUCTORS
DATA SH EET
M3D176
BAX18
General purpose diode
Product specification Supersedes data of April 1996
1996 Sep 18
Page 2
Philips Semiconductors Product specification
General purpose diode BAX18
FEATURES
Hermetically sealed leaded glass SOD27 (DO-35) package
Switching speed: max. 50 ns
DESCRIPTION
The BAX18 is a general purpose diode fabricated in planar technology, and encapsulated in the hermetically sealed leaded glass SOD27 (DO-35) package.
General application
Continuous reverse voltage:
max. 75 V
Repetitive peak reverse voltage:
handbook, halfpage
k
a
max. 75 V
Repetitive peak forward current:
MAM246
max. 2 A.
The diode is type branded.
APPLICATIONS
Fig.1 Simplified outline (SOD27; DO-35) and symbol.
Rectifier applications.
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 134).
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
V V I
F
I
FRM
I
FSM
RRM R
repetitive peak reverse voltage 75 V continuous reverse voltage 75 V continuous forward current see Fig.2; note 1 500 mA repetitive peak forward current 2000 mA non-repetitive peak forward current square wave; Tj=25°C prior to
surge; see Fig.4
t=1µs 55 A t = 100 µs 15 A t = 10 ms 9A
P
tot
T
stg
T
j
total power dissipation T
=25°C; note 1 450 mW
amb
storage temperature 65 +200 °C junction temperature 200 °C
Note
1. Device mounted on an FR4 printed circuit-board; lead length 10 mm.
Page 3
Philips Semiconductors Product specification
General purpose diode BAX18
ELECTRICAL CHARACTERISTICS
T
=25°C; unless otherwise specified.
j
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
V
F
I
R
C
d
t
rr
THERMAL CHARACTERISTICS
forward voltage see Fig.3
I
= 300 mA 1.0 V
F
I
= 2 A; Tj= 150 °C 1.5 V
F
reverse current see Fig.5
V
=75V 5 µA
R
V
=75V; Tj= 150 °C 100 µA
R
diode capacitance f = 1 MHz; VR= 0; see Fig.6 35 pF reverse recovery time when switched from IF= 30 mA to
50 ns IR= 30 mA; RL= 100 ; measured at IR= 3 mA; see Fig.7
SYMBOL PARAMETER CONDITIONS VALUE UNIT
R R
th j-tp th j-a
thermal resistance from junction to tie-point lead length 10 mm 240 K/W thermal resistance from junction to ambient lead length 10 mm; note 1 375 K/W
Note
1. Device mounted on a printed circuit-board without metallization pad.
Page 4
Philips Semiconductors Product specification
General purpose diode BAX18
GRAPHICAL DATA
amb
MBG455
(oC)
500
handbook, halfpage
I
F
(mA)
400
300
200
100
0
0 100 200
Device mounted on an FR4 printed-circuit board; lead length 10 mm.
T
Fig.2 Maximum permissible continuous forward
current as a function of ambient temperature.
handbook, halfpage
3
I
F
(A)
2
1
0
012
(1) Tj= 175 °C; typical values. (2) Tj=25°C; typical values. (3) Tj= 150 °C; maximum values. (4) Tj=25°C; maximum values.
(1) (2) (3) (4)
MBG467
VF (V)
Fig.3 Forward current as a function of forward
voltage.
2
10
handbook, full pagewidth
I
FSM
(A)
10
1
1
10
1
Based on square wave currents. Tj=25°C prior to surge.
Fig.4 Maximum permissible non-repetitive peak forward current as a function of pulse duration.
MBG702
10
2
10
3
10
tp (µs)
4
10
Page 5
Philips Semiconductors Product specification
General purpose diode BAX18
4
handbook, full pagewidth
VR=75V. Solid line; maximum values. Dotted line; typical values.
10
I
R
(µA)
3
10
2
10
10
1
1
10
2
10
0 100 200
Fig.5 Reverse current as a function of junction temperature.
MBG697
T
(oC)
j
40
handbook, halfpage
C
d
(pF)
30
20
10
0
0102030
f = 1 MHz; Tj=25°C.
MGD003
V
(V)
R
Fig.6 Diode capacitance as a function of reverse
voltage; typical values.
Page 6
Philips Semiconductors Product specification
General purpose diode BAX18
handbook, full pagewidth
R = 50SΩ
V = V I x R
RF S
(1) IR= 3 mA.
I
F
D.U.T.
SAMPLING
OSCILLOSCOPE
R = 50iΩ
MGA881
t
r
10%
V
R
90%
t
p
input signal
Fig.7 Reverse recovery voltage test circuit and waveforms.
t
I
F
t
rr
t
(1)
output signal
Page 7
Philips Semiconductors Product specification
General purpose diode BAX18
PACKAGE OUTLINE
k, full pagewidth
Dimensions in mm.
1.85 max
25.4 min
4.25 max
25.4 min
0.56 max
MLA428 - 1
Fig.8 SOD27 (DO-35).
DEFINITIONS
Data Sheet Status
Objective specification This data sheet contains target or goal specifications for product development. Preliminary specification This data sheet contains preliminary data; supplementary data may be published later. Product specification This data sheet contains final product specifications.
Limiting values
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.
Loading...