Datasheet BAT64, BAT64-02V, BAT64-02W, BAT64-04, BAT64-04T Datasheet (INFINEON)

...
Page 1
Silicon Schottky Diodes
For low-loss, fast-recovery, meter protection, bias isolation and clamping application
Integrated diffused guard ring
Low forward voltage
BAT64...
BAT64-02V BAT64-02W
BAT64-04 BAT64-04T
BAT64-05 BAT64-05W
BAT64-06W
BAT64-04W
!
!
, 
,
!
,
, 
!
,
, 
ESD (Electrostatic discharge) sensitive device, observe handling precaution!
Type Package Configuration L
BAT64 BAT64-02V* BAT64-02W BAT64-04 BAT64-04T* BAT64-04W BAT64-05 BAT64-05W BAT64-06
SOT23 SC79 SCD80 SOT23 SC75 SOT323 SOT23 SOT323 SOT23
single single single series series series common cathode common cathode common anode
(nH) Marking
S
1.8
0.6
0.6
1.8
1.6
1.4
1.8
1.4
1.8
63s t 64 64s S1 64s 65s 65s 66s
BAT64-06W
* Preliminary data
SOT323
common anode
1
1.4
66s
2005-10-18
Page 2
Maximum Ratings at TA = 25°C, unless otherwise specified
BAT64...
Parameter
Diode reverse voltage V Forward current I Non-repetitive peak surge forward current
(t 10ms) Average forward current (50/60Hz, sinus) I
Total power dissipation BAT64, T BAT64-02V, BAT64-02W, T BAT64-04, BAT64-06, T BAT64-04W, BAT64-06W, T BAT64-05, T BAT64-05W, T BAT64-04T, T
86°C
S
36°C
S
S
104°C
S
tbd
121°C
S
61°C
S
111°C
S
Junction temperature T Storage temperature T
Symbol Value Unit
R
F
I
FSM
FAV
P
tot
40 V 250 mA 800
120
mW 250 250
250 250 250 250 250
j stg
150 °C
-55 ... 150
Thermal Resistance Parameter
Junction - soldering point1) BAT64 BAT64-02V, BAT64-02W BAT64-04, BAT64-06, BAT64-04W, BAT64-06W BAT64-05 BAT64-05W BAT64-04T
1
For calculation of R
please refer to Application Note Thermal Resistance
thJA
Symbol Value Unit
R
thJS
K/W
255 115 355 155 455 185
tbd
2
2005-10-18
Page 3
Electrical Characteristics at TA = 25°C, unless otherwise specified
BAT64...
Parameter
DC Characteristics
Breakdown voltage
= 10 µA
I
(BR)
Reverse current
= 30 V
V
R
= 30 V, TA = 85 °C
V
R
Forward voltage
= 1 mA
I
F
= 10 mA
I
F
= 30 mA
I
F
= 100 mA
I
F
AC Characteristics
Diode capacitance
V
= 1 V, f = 1 MHz
R
Symbol Values Unit
min. typ. max.
V
I
V
C
(BR)
R
F
T
40 - - V
-
-
270 310 370 500
-
-
320 385 440 570
2
200
350 430 520 750
- 4 6 pF
µA
mV
Reverse recovery time
I
= 10 mA, IR = 10 mA, measured IR = 1 mA ,
F
R
= 100
L
t
rr
- - 5 ns
3
2005-10-18
Page 4
BAT64...
Diode capacitance CT = ƒ (VR)
f = 1MHz
10 pF
C
T
8 7 6 5 4 3 2
1
0
0
10 20 V 30
Reverse current IR = ƒ(VR)
= Parameter
T
A
EHB00059BAT 64...
Ι
R
V
R
BAT 64... EHB00058
2
10
A
µ
T
A
1
10
0
10
-1
10
-2
10
-3
10
0102030
= 125
25
V
R
85
V
C
C
C
Forward current IF = ƒ (VF)
= Parameter
T
A
BAT 64... EHB00057
2
10
mA
Ι
F
1
10
T
0
10
-1
10
-2
10
0 0.5
A
= -40
25 85
125
Forward current IF = ƒ (TS) BAT64W
300
mA
C C C C
1
V
V
F
200
F
I
150
100
50
0
0 15 30 45 60 75 90 105 120
°C
T
150
S
4
2005-10-18
Page 5
BAT64...
Forward current IF = ƒ (TS)
BAT64-02V, BAT64-02W
300
mA
200
F
I
150
100
50
0
0 15 30 45 60 75 90 105 120
Forward current IF = ƒ (TS) BAT64-04, BAT64-06
300
mA
200
F
I
150
100
50
°C
150
T
S
0
0 15 30 45 60 75 90 105 120
°C
T
150
S
Forward current IF = ƒ (TS) BAT64-04W, BAT64-06W
300
mA
200
F
I
150
100
50
0
0 15 30 45 60 75 90 105 120
Forward current IF = ƒ (TS) BAT64-05
300
mA
200
F
I
150
100
50
°C
150
T
S
0
0 15 30 45 60 75 90 105 120
°C
T
150
S
5
2005-10-18
Page 6
BAT64...
Forward current IF = ƒ (TS)
BAT64-05W
300
mA
200
F
I
150
100
50
0
0 15 30 45 60 75 90 105 120
Permissible Puls Load R
thJS
= ƒ (tp)
BAT64-02V, BAT64-02W
3
10
K/W
2
10
thJS
R
10
D=0.5
0.2
0.1
0.05
0.02
0.01
0.005 0
-4
10
-3
10
-2
s
t
0
10
P
1
10
0
10
-1
10
°C
150
T
S
10
-6
10
-5
Permissible Pulse Load
I
Fmax
/ I
FDC
= ƒ (tp)
BAT64-02V, BAT64-02W
2
10
FDC
/I
Fmax
I
1
10
0
10
-6
10
10
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
-5
10
-4
10
Permissible Puls Load R
thJS
= ƒ (tp)
BAT64-04W, BAT64-06W
3
10
K/W
2
10
thJS
R
1
10
0.5
0.2
0.1
0.05
10
0.02
0.01
0.005 D = 0
-3
10
-2
s
10
0
tP
0
10
-1
-3
10
-2
s
t
0
10
P
10
10
-6
10
-5
10
-4
6
2005-10-18
Page 7
BAT64...
Permissible Pulse Load
I
Fmax
/ I
FDC
= ƒ (tp)
BAT64-04W, BAT64-06W
2
10
-
FDC
/I
Fmax
I
1
10
0
10
10
-6
10
-5
10
-4
10
D = 0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
-3
10
Permissible Puls Load R
thJS
= ƒ (tp)
BAT64-05W
3
10
K/W
2
10
thJS
R
1
10
0.5
0.2
0.1
0.05
10
0.02
0.01
0.005 D = 0
-3
10
-2
s
10
0
tP
0
10
-1
-2
s
10
0
10
10
-6
10
-5
10
-4
tP
Permissible Pulse Load
I
Fmax
/ I
FDC
= ƒ (tp)
BAT64-05W
2
10
-
FDC
/I
Fmax
I
1
10
0
10
10
-6
10
-5
10
-4
10
D = 0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
-3
10
-2
s
t
0
10
p
7
2005-10-18
Page 8
Package Outline
Foot Print
Package SC75
±0.2
1.6
+0.1
0.2
-0.05
A
0.2
0.10
+0.1
-0.05
0.5
M
3
1 2
0.5
0.4
0.1 MAX.
±0.2
1.6
MAX.
10˚
0.20MA
0.7
0.15
±0.1
±0.1
±0.1
0.8
MAX.
10˚
BAT64...
Marking Layout
Pin 1
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel
0.65
1.15
0.65
Manufacturer
Type code BCR108T
0.4
0.50.5
Example
4
0.45
0.2 MAX.
Pin 1
1.75
1.4
8
8
1.8
0.9
2005-10-18
Page 9
Package Outline
Foot Print
Package SC79
±0.1
0.8 2
Cathode marking
1
0.3
±0.05
±0.1
1.6
0.55
MAX.
˚
10
±0.04
M
A0.2
0.13
+0.05
-0.03
A
MAX.
˚
10
±0.1
1.2
±0.05
0.2
BAT64...
Marking Layout
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel
1.35
Date code
Type code Laser marking
0.35
0.35
2003, July
BAR63-02V Cathode marking
Example
Cathode marking
4
1.96
1.33
8
0.4
0.93
9
0.2
0.66
2005-10-18
Page 10
Package Outline
Foot Print
Cathode marking
Package SCD80
0.2MA
±0.1
0.8 2
MAX.
˚
±0.1
10
1.7
1
±0.05
0.3
0.7
0.13
±0.1
+0.05
-0.03
˚
±1.5
˚
7
BAT64...
A
±0.1
1.3
±0.05
0.2
Marking Layout
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel
1.45
Date code
Type code Laser marking
0.35
0.35
2003, July
BAR63-02W Cathode marking
Example
Cathode marking
4
1.45 8
2.5
0.4
0.9
10
0.2
0.7
2005-10-18
Page 11
BAT64...
Data Code marking for discrete packages with  one digit (SCD80, SC79) CES-Code
Month 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014
01apAPapAPapAP 02bqBQbqBQbqBQ 03crCRcrCRcrCR 04 d s D S d s D S d s D S 05etETetETetET 06fuFUfuFUfuFU 07gvGVgvGVgvGV 08hxHXhxHXhxHX 09j yJYj yJYj y JY
10kzKZkzKZkzKZ
11l 2L4l 2L4l 2L4
12n3N5n3N5n3N5
62
11
2005-10-18
Page 12
Package Outline
Foot Print
Package SOT23
±0.1
2.9
12
1)
+0.1
0.4
-0.05
1.9
0.25MBC
1) Lead width can be 0.6 max. in dambar area
B
3
C
0.95
0.8
0.15 MIN.
±0.15
2.4
0.2
±0.1
1
0.1 MAX.
10˚ MAX.
0.08...0.15
0...8˚
M
A
±0.1
1.3
10˚ MAX.
A
BAT64...
Marking Layout
12
Pin 1
s
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel
0.8 1.2
Manufacturer
Date code (Year/Month)
Type code
4
0.9
0.9 0.91.3
EH
Example
0.2
s
2003, July
37
BCW66
Pin 1
3.15
2.13
12
2.65
8
1.15
2005-10-18
Page 13
Package Outline
Package SOT323
±0.2
2
0.3
+0.1
-0.05
3x
M
0.1
3
0.1 MAX.
0.1
0.9
BAT64...
±0.1
A
Foot Print
Marking Layout
12
0.650.65
0.6
1.6
0.8
0.65
0.65
±0.1
2.1
0.1 MIN.
M
0.2 A
0.15
+0.1
-0.05
±0.1
1.25
Pin 1
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel
Pin 1
Manufacturer
Date code (Year/Month)
Type code
4
2.15
2005, June
BCR108W
Example
0.2
8
2.3
1.1
13
2005-10-18
Page 14
BAT64...
Published by Infineon Technologies AG, St.-Martin-Strasse 53, 81669 München © Infineon Technologies AG 2005. All Rights Reserved.
Attention please!
The information herein is given to describe certain components and shall not be considered as a guarantee of characteristics. Terms of delivery and rights to technical change reserved. We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding circuits, descriptions and charts stated herein.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office (www.Infineon.com).
Warnings Due to technical requirements components may contain dangerous substances.
For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.
14
2005-10-18
Loading...