Surge Arrester A81-A230X
2-Electrode-Arrester Ordering code: B88069X2250S102
DC spark-over voltage
1) 2)
230 ± 20
V %
Impulse spark-over voltage at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs)
Nominal alternating discharge current (50 Hz, 1 s) Alternating discharge current (50 Hz, 9 cycles)
Service life, alternating polarity 300 operations 10/1000 µs
Insulation resistance at 100 Vdc > 10
< 500 < 450
< 650 < 550
20 25
20 100
100
V V
V V
kA kA
A A
A
G
Capacitance at 1 MHz < 1.5 pF
Arc voltage at 1 A Glow to arc transition current Glow voltage
~ 15 ~ 0.5 ~ 60
V A V
Weight ~ 1.5 g
Operation and storage temperature -40 ... +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, blue
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
Terms and tests in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
230 - Nominal voltage YY - Year of production O - Non radioactive
230 YY O
AB E / AB PM Issue 06, 19.08.2002
Page 1 of 2
Page 2
Surge Arrester A81-A230X
2-Electrode-Arrester Ordering code: B88069X2250S102
Not to scale
Dimensions in mm
Non controlled document
EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed.
AB E / AB PM Issue 06, 19.08.2002
Page 2 of 2