Datasheet B 84143 – B xxx- S 24, B 84143 – B xxx- S 20 Datasheet (Epcos)

www.DataSheet4U.com
3-Line Filters
for Converters and Power Electronics
Power line filters for three-phase systems Rated voltage 500, 690 and 760 V~ Rated current 150 A to 2500 A
Construction
Three-line filter
Metal case
Features
Low leakage current
Easy to install
Very compact design
B84143-B150...B600-S20: UL, CUL approval
B84143-B150...B600-S21/S24: UL, CUL approval for 600/350 V~
Optimized for operation under full load
Low weight
Applications
B84143-***-S24 for IT mains supply
Frequency converters for motor drives
Wind farms
Power supplies
Terminals
Busbars
B84143-B*-S20
… B84143-B*-S24
Marking
Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, rated temperature, date code
Minimum marking on packaging: Manufacturer’s logo, ordering code
Typical circuit diagram
LINE LOAD
L1
L2 L2’
L3
L1’
L3’
SSB1212-L
255 03/01
3-Line Filters
for Converters and Power Electronics
Technical data
B84143-B*-S20
… B84143-B*-S24
Rated voltage V
R
500/290 V~, 50/60 Hz (type -S20) 690/400 V~, 50/60 Hz (type -S24); UL, CUL 600/350 V~ 760/440 V~, 50/60 Hz (type -S21);UL, CUL 600/350 V~
Rated current I
Test voltage V
R
P
Referred to 40 °C ambient temperature
2121 V–, 2 s (line/line) 2686 V–, 2 s (lines/case) type -S20 2890 V–, 2 s (lines/case) type -S21, -S24
Overload capability 1,5 · I
Leakage current I
leak
for 3 min per hour or
R
for 30 s per hour
2,5 · I
R
at VR, 50 Hz
Climatic category 25/100/21 (– 25 °C/+ 100 °C/21 days damp heat test)
in accordance with EN 60068-1
Characteristics and ordering codes
I
R
I
leak
R
typ
Approx.
Ordering code
weight
A
mA
µΩ
kg
150 < 6 140 13 B84143-B150-S**
180 < 6 140 13 B84143-B180-S**
250 < 6 63 15 B84143-B250-S**
320 < 6 67 21 B84143-B320-S**
400 < 6 67 21 B84143-B400-S**
600 < 6 52 22 B84143-B600-S**
1000 < 6 33 28 B84143-B1000-S**
1600 < 6 22 34 B84143-B1600-S**
2500 < 6 15 105 B84143-B2500-S**
Compilation of ordering code
Replace the asterisks ** by the code number for the required version: 20 = 500 V 21 = 760 V 24 = 690 V (filter for IT mains supply. See also chapter “General, network types”, page 51)
256 03/01
3-Line Filters
for Converters and Power Electronics
Dimensional drawings
B84143-B150-S**, B84143-B180-S**
B84143-B*-S20
… B84143-B*-S24
32±1
3
ø9
L1
L2L3
LINE LOAD
B84143-B250-S**
5
L1L2L3
LINE LOAD
260 150
Marking
115±0,2
310±2
300
240±0,6
Marking
6,6
32±1
L1L2L3
170
155±0,2
97,597,5
1010
20
PE M10 x 30
6060
L1L3 L2
165
190
91
36
80
2
80
2 × M5 / 5 mm deep
2 x M5 / 5 mm tief
81
141
SSB1266-K
91
36
30
140
120
2 × M6 / 6 mm deep
2 x M6 / 6 mm tief
30
140
110
ø12
360±2
ø11 PE M10 x 30
42±142±1
1515
25
257 03/01
2
116
SSB1206-C
3-Line Filters
for Converters and Power Electronics
B84143-B320-S**, B84143-B400-S**
B84143-B*-S20
… B84143-B*-S24
300
L1L3 L2
6060
260
235±1
240±1
L1L2L3
5
Marking
LOADLINE
ø12
360±2
42±242±2
1515
25
ø11 PE M10 x 30
B84143-B600-S**
350
290±1
5
L1L2L3
Marking
LOADLINE
6060
L1L3 L2
235±1
260
16
120
2
120
36
91
4 × M6 / 6 mm deep
4 x M6 / 6 mm tief
85±0,5
116
SSB1207-K
91
36
30
210
180±0,5
4 × M6 / 6 mm deep
4 x M6 / 6 mm tief
30
210
180±0,5
ø12
410±2,5
ø11 PE M10 x 30
42±342±3
1515
30
258 03/01
16
2
85±0,5
116
SSB1208-T
3-Line Filters
for Converters and Power Electronics
B84143-B1000-S**
350
290±1
B84143-B*-S20
… B84143-B*-S24
6565
141
61
4 × M6 / 6 mm deep
4 x M6 / 6 mm tief
8
L3 L2 L1
52±3
ø14
B84143-B1600-S**
105
10
L3 L2 L1
ø12
Marking
420±2,5
LOADLINE
400
340±1
Marking
SSB1209-2
40
250
220±0,8
L2L3 L1
52±3
300
275±1
2020
40
PE M12 x 30
2,5
16
160
135±0,8
166
141
105
L2L3 L1
300
275±1
LOADLINE
160
61
4 × M6 / 6 mm deep
4 x M6 / 6 mm tief
40
250
220±0,8
92±3
ø14
ø12
550±3
92±3
2020
4040
PE M12 x 30
259 03/01
2,5
135±0,8
16
166
50
SSB1210-5
3-Line Filters
for Converters and Power Electronics
B84143-B2500-S**
B84143-B*-S20
… B84143-B*-S24
650
125
15
L3 L2 L1
93±3
40
ø14 PE M16 x 50
560±1,5
Marking
LOADLINE
ø14
810±3,5
L2L3 L1
125
93±3
40
385
355±1
2020
40
80
3,5
16,5
200
91,5
191,5
190±1 221,5
4 × M6 / 6 mm deep
4 x M6 / 6 tief
SSB1211-D
60
320
286±1
260 03/01
3-Line Filters
α
for Converters and Power Electronics
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84143-B150-S20, B84143-B180-S20 B84143-B250-S20
100
dB
α
e
SSB1267-T
80
100
dB
α
e
80
B84143-B*-S20
… B84143-B*-S24
SSB1799-S
60
40
20
0
10
4
5
10 10
6
10
7
Hz
10
8
f
60
40
20
0
10
10
54
10
6
7
10 Hz
10
8
f
B84143-B320-S20 … B84143-B2500-S20
100
SSB1800-Z
dB
e
80
60
40
20
0
456Hz7
1010 10
10
8
10
f
261 03/01
3-Line Filters
for Converters and Power Electronics
B84143-B*-S20
… B84143-B*-S24
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84143-B150-S21, B84143-B250-S21 B84143-B320-S21 … B84143-B2500-S21
100
dB
α
e
SSB1267-T
80
100
dB
α
e
80
SSB1204-V
60
40
20
0
10
4
5
10 10
6
10
7
Hz
10
8
f
60
40
20
0
10
4
5
10 10
6
10
7
Hz
f
B84143-B150-S24, B84143-B250-S24 B84143-B320-S24 … B84143-B2500-S24
100
dB
α
e
SSB1268-2
80
60
40
20
100
dB
α
e
80
60
40
20
SSB1801-8
10
8
0
10
4
5
10 10
6
10
7
Hz
10
8
0
10
f
10
54
10
6
7
10 Hz
10
8
f
262 03/01
Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 1709, 81617 München, DEUTSCHLAND
++49 89 636 09, FAX (0 89) 636-2 26 89
EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesell­schaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe en­thalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen.
Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
++49 89 636 09, FAX (0 89) 636-2 26 89
EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices.
1
Loading...