Datasheet B 84143 – B x – R Datasheet (Epcos)

www.DataSheet4U.com
3-Line Filters B84143-B*-R
for Converters and Power Electronics
Power line filters for three-phase systems Rated voltage 440/250 V~, 50/60 Hz Rated current 8 A to 80 A
Three-line filter
Metal case
Features
Very high insertion loss
due to two-stage construction
Low leakage current
Easy to install
Degree of protection: IP 20
Design complies with
1)
EN 133200, UL 1283, CSA 22.2 No.8 1986
Optimized for long motor cables and
operation under full load
Applications
Frequency converters for motor drives, e.g.
elevatorspumpstraction systemsconveyor systemsHVAC systems (heating, ventilation and air conditioning)
Wind farms
Power supplies
Terminals
Safe-to-touch terminal blocks
Marking
Marking on component: Manufacturers logo, ordering code, rated current, rated voltage, rated temperature, climatic category, date code
Minimum marking on packaging: Manufacturers logo, ordering code
1) In accordance with IEC 60529:1989; EN 60529:1991; DIN VDE 0470-1
233 03/01
3-Line Filters B84143-B*-R
for Converters and Power Electronics
Typical circuit diagram
LINE
L1
L2 L2
L3
LOAD
SSB0805-1
Technical data
Rated voltage V Rated current I Test voltage V
R
R
P
Overload capability 1,5 · I
Leakage current I
leak
Climatic category 25/100/21 (– 25
440/250 V~, 50/60 Hz Referred to 40 °C ambient temperature 1770 V–, 2 s (line/line)
2700 V–, 2 s (lines/case)
for 3 min per hour or
R
2,5 · I
for 30 s per hour
R
at 230 V~, 50 Hz
°C/+ 100 °C/21 days damp heat test)
in accordance with EN 60068-1
Characteristics and ordering codes
L1
L3
I
R
A
Terminal cross section
2
mm
8 4 12 4 16 4 25 10 36 10 50 10 80 25
I
leak
mA
< 3,5 80 3,8 B84143-B8-R < 3,5 40 3,8 B84143-B12-R < 3,5 25 3,8 B84143-B16-R < 3,5 10 5,7 B84143-B25-R < 3,5 5,0 5,7 B84143-B36-R < 6 3,5 5,7 B84143-B50-R < 6 2,0 16 B84143-B80-R
R
m
typ
For higher currents refer to B84143-B**-R110, page 246.
234 03/01
Approx. weight kg
Ordering code
3-Line Filters B84143-B*-R
for Converters and Power Electronics
Dimensional drawings
B84143-B8-R … B84143-B16-R
20,5±0,5
81 max.
PE M6 x 25
193 max.
36±1
1±0,1
22,5±1
126 max.
30±1
115±0,2
Marking
L3 L2 L1
LINE LOAD
6,6±0,2
171 max.
B84143-B25-R … B84143-B50-R
PE M6 x 25
281 max.
115±0,2
L1L2L3PE
Marking
LINE LOAD
L1L2L3
140±0,3
156 max.
Anschlussklemmen
Terminal blocks
2
2
4 mm
4mm
31±0,5
91 max.
46±1
140±0,3
PE L3 L2 L1
156 max.
1±0,1
SSB1006-Z
30±1
22,5±1
126 max.
6,6±0,2
231 max.
Anschlussklemmen
Terminal blocks
2
2
10 mm
10 mm
235 03/01
SSB1007-8
3-Line Filters B84143-B*-R
for Converters and Power Electronics
B84143-B80-R
PE M10 x 35
L1 L2 L3
PE
6,6±0,2
409 max. 331 max.
Marking
LINE LOAD
82,5±0,2 82,5±0,2
48,5±0,5
141 max.
73±1
L1 L2 L3 PE
155±0,3
171 max.
Anschlussklemmen
Terminal blocks
2
25 mm
2
25 mm
1,0±0,1
45±0,5
23±0,5
141 max.
SSB0993-K
236 03/01
3-Line Filters B84143-B*-R
for Converters and Power Electronics
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84143-B8-R B84143-B12-R
100
dB
α
e
80
60
40
20
0
10
10
5
6
10 10 Hz 10
SSB0806-9
100
dB
α
e
80
60
40
20
847
f
0
10
B84143-B16-R B84143-B25-R
100
100
dB
dB
α
e
80
80
SSB0808-Q
100
dB
α
e
80
10
SSB0807-H
5
10
6
7
10 Hz 10
84
f
SSB0809-Y
60
60
40
40
20
20
0
0
10
10
5
10
6
7
10 Hz 10
84
f
60
40
20
0
10
4
10
5
10
6
107Hz 10
8
f
237 03/01
3-Line Filters B84143-B*-R
for Converters and Power Electronics
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84143-B36-R B84143-B50-R
B84143-B80-R
100
dB
α
e
SSB0810-2
80
60
40
20
0
10
4
10
5
10
6
7
10 Hz810
100
dB
α
e
80
60
40
20
0
4
f
56
1010
1010
SSB0994-T
7
Hz
8
10
f
238 03/01
Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgele- genen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland.
Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsge­sellschaft einzuholen.
Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this bro­chure and the information contained therein without EPCOS prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be con­sidered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices.
1
Loading...