Max. operating temperature T
Dissipation factor tan δ (in 10-3)
at 20 °C (upper limit values)
op,max
+110 °C
CR≤0.1 µF 0.1µF<CR≤2.2 µF CR>2.2 µF
at
1 kHz1.01.02.0
100 kHz5.0
Insulation resistance R
ins
or time constant τ = CR R
ins
CR≤0.33 µFCR>0.33 µF
100 000 MΩ 30 000 s
at 20 °C, rel. humidity ≤ 65%
(minimum as-delivered values)
DC test voltage2121 V, 2 s
Passive flammability category
B
to IEC 40 (CO) 752
Maximum continuous AC voltage V
310 V (50/60 Hz)
AC
Rated AC voltage (IEC 60384-14)305 V (50/60 Hz)
Operating AC voltage Vopat high
temperature
TA≤ 110 °CVop= V
AC
TA≤ 110 °CVop= 1.25 VAC(1000 h)
Damp heat test56 days / 40 °C / 93% relative humidity
Limit values after damp heat testCapacitance change ∆C/C≤ 5%
Dissipation factor change ∆ tan δ ≤ 0.5 10-3(at 1 kHz)
Insulation resistance R
ins
or time constant τ = CR R
≤ 1.0 10-3(at 10 kHz)
≥ 50% of minimum
ins
as-delivered values
(continuously)
at the end of this document.
Page 6 of 8Please read Important notes
Page 7
B32921C/D ... B32926C/D
X2 / 305 VAC
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/µs.
Note:
The values of dV/dt and k0provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt and k0values
Lead spacing10 mm15 mm22.5 mm27.5 mm37.5 mm
VersionC/DC/DC/DC/DC/D
dV/dt in V/µs47534017012080
k0in V2/µs40850029240014620010320068800
Impedance Z versus frequency f
(typical values)
at the end of this document.
Page 7 of 8Please read Important notes
Page 8
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical re-
quirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as bindingstatements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic compo-
nents or failure before the end of their usual service life cannot be completely ruled out
in the current state of the art, even if they are operated as specified. In customer applica-
tions requiring a very high level of operational safety and especially in customer applications
in which the malfunction or failure of a passive electronic component could endanger human
life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured
by means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Ma-
terial Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-
sion of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association
(ZVEI).
MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap,
SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarksregistered or pending in Europe and in other countries. Further information will be found on
the Internet at www.epcos.com/trademarks.
Page 8 of 8