1. Output relays for programmable
controllers and temperature
controllers
2. Industrial equipment, office
equipment
3. Measuring devices and test
equipment
TYPES
Contact arrangementNominal coil voltagePart No.
1 Form A
Standard packing: Tube: 25 pcs.; Case: 1,000 pcs.
* Terminal sockets available.
3 V DCAPAN3103
4.5 V DCAPAN314H
5 V DCAPAN3105
6 V DCAPAN3106
9 V DCAPAN3109
12 V DCAPAN3112
18 V DCAPAN3118
24 V DCAPAN3124
–1–
ASCTB368E 201604-T
Page 2
PA-N (APAN3)
RATING
1. Coil data
Nominal coil
voltage
3 V DC
4.5 V DC24.4 mA 184 Ω
5 V DC22.0 mA 227 Ω
6 V DC18.3 mA 327 Ω
9 V DC12.2 mA 736 Ω
12 V DC 9.2 mA1,309 Ω
18 V DC 6.1 mA2,945 Ω
24 V DC 4.6 mA5,236 Ω
Note: *Pulse drive (JIS C 5442)
Pick-up voltage
(at 20°C 68°F)
70%V or less of
nominal voltage*
(Initial)
Drop-out voltage
(at 20°C 68°F)
5%V or more of
nominal voltage*
(Initial)
2. Specifications
CharacteristicsItemSpecifications
Arrangement1 Form A (Bifurcated)
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. Operating frequency of 5 A 250 V AC is 6 times/min. (ON : OFF = 1 s : 9 s)
Contact resistance (Initial)Max. 30 mΩ (By voltage drop 6 V DC 1A)
Contact materialAgNi type + Au
Nominal switching capacity (resistive load)5 A 250 V AC, 5 A 30 V DC
Max. switching power (resistive load)1,250 VA, 150 W
Max. switching voltage250 V (AC), 110 V (DC) (0.4 A)
Max. switching current5 A (AC, DC)
Nominal operating power110 mW
Min. switching capacity (Reference value)*
Insulation resistance (Initial)Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Surge breakdown voltage (Initial)
(Between contacts and coil)*
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Between open contacts1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil3,000 Vrms for 1min. (Detection current: 10mA.)
2
FunctionalMin. 147 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
DestructiveMin. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Functional10 to 55 Hz at double amplitude of 2.5 mm (Detection time: 10μs.)
Destructive10 to 55 Hz at double amplitude of 3.5 mm
Nominal operating
current
[±10%] (at 20°C 68°F)
36.7 mA 82 Ω
1
1 mA 5 V DC
6,000 V
Max. 10 ms (excluding contact bounce time)
Max. 5 ms (excluding contact bounce time and without diode)
Min. 10
Min. 5×10
Ambient temperature: –40°C to 90°C –40°F to 194°F;
3
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Coil resistance
[±10%] (at 20°C 68°F)
5
(3 A 250 V AC, 30 V DC, resistive load)
4
(5 A 250 V AC, 30 V DC, resistive load) (at 20 times/min.)*
Nominal operating
power
110mW
4
Max. applied voltage
(at 20°C 68°F)
120%V of
nominal voltage
4
–2–
ASCTB368E 201604-T
Page 3
REFERENCE DATA
1. Max. switching capacity2. Life curve3. Coil temperature rise
10
5
DC resistive load
1
Contact current, A
0.4
0.1
AC resistive load
Contact voltage, V
4
100
50
40
30
AC250V cos =0.4
20
10
No. of operations, ×10
5
1000100101
1
0.10.513 510
AC250V resistive load
DC30V resistive load
DC30V L/R=7ms
φ
Switching capacity, A
Tested sample: APAN3124, 6 pcs.
Measured portion: Inside the coil
Ambient temperature: 20°C 68°F, 90°C 194°F (No
contact current)
5 A 250 V AC Resistive
5 A 30 V DC General use
5 A 30V DC, 3 A 250 V AC General use
3 A 250 V AC Resistive
3 A 30 V DC General use
B300, R300 Pilot duty