Datasheet ALDP124, ALDP112, ALDP105 Specification

Page 1
Slim (7.2mm .283inch),
LD-P RELAYS (ALDP)
FEATURES
1. Nominal switching capacity: 5A 277V AC
2. Excellent heat resistance and tracking performance
EN60695 (GWT2-11, GWFI2-12, GWIT2-13) data available (Please consult us for details.)
3. Slim type: 20.5 (L) × 7.2 (W) × 15.3
RoHS compliant
Protective construction: Sealed type
(H) mm .807 (L) × .283 (W) × .602 (H)
inch
4. Class “B” and “F” coil is available
5. Contact rating at 105°C 221°F is approved by UL/C-UL and VDE (Class “F” coil only)
6. Clearance and Creepage distance between contact and coil min. 6 mm
.236 inch
7. High surge voltage: 10,000 V between contact and coil
ORDERING INFORMATION
ALDP 1 W
LD-P relay
Contact arrangement 1: 1 Form A
Nominal coil voltage (DC) 05: 5V, 06: 6V, 09: 9V, 12: 12V, 18: 18V, 24: 24V
Packing style W: Carton packing
Notes: 1. Certified by UL/C-UL, VDE and CQC
2. Class “B” and “F” coil is available (Class “B”: ALDP1B**W, Class “F”: ALDP1F**W)
TYPICAL APPLICATIONS
• Boilers
• Air conditioner
• Refrigerator
• Hot water units
• Microwave ovens
• Fan heaters
TYPES
Contact arrangement Nominal coil voltage Part No.
5V DC ALDP105W
6V DC ALDP106W
1 Form A
Packing quantity: Carton 100 pieces, Case 500 pieces Note: The “W” at the end of the part number only appears on the inner and outer packaging. It does not appear on the relay itself.
Please consult with our sales office on a tube packing type.
9V DC ALDP109W
12V DC ALDP112W
18V DC ALDP118W
24V DC ALDP124W
–1–
ASCTB193E 201603-T
Page 2
LD-P (ALDP1)
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
5V DC
6V DC 33.3mA 180Ω
9V DC 22.2mA 405Ω
12V DC 16.7mA 720Ω
18V DC 11.1mA 1,620Ω
75%V or less of nominal voltage
(Initial)
5%V or more of nominal voltage
(Initial)
24V DC 8.3mA 2,880Ω
2. Specifications
Characteristics Item Specifications
Arrangement 1 Form A
Contact
Rating
Electrical characteristics
Mechanical characteristics
Expected life
Conditions
Unit weight Approx. 4 g .14 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgNi type
Nominal switching capacity (resistive load) 5A 277V AC, 3A 30V DC
Max. switching power (resistive load) 1,385VA, 90W
Max. switching voltage 277V AC, 30V DC
Max. switching current 5A (AC), 3A (DC)
Min. switching capacity (reference value)*
1
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage (Initial)
Surge breakdown voltage* (Between contact and coil) (Initial)
Between open contacts 750 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
2
Operate time (at nominal voltage) (at 20°C 68°F) Max. 10 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F) Max. 10 ms (excluding contact bounce time) (With diode)
Shock resistance
Vibration resistance
Functional 300 m/s
Destructive 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Mechanical (at 180 times/min.) Min. 5×10
Electrical (at 20 times/min.) (resistive load) Min. 2×105 (5A 125V AC at rated load), Min. 105 (5A 250V AC, 3A 30V DC)
Conditions for operation, transport and storage*
Max. operating speed 20 times/min. (at nominal switching capacity)
actual load.
conditions in NOTES.
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
40.0mA 125Ω
200mW
100mA 5V DC
10,000 V
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
6
Ambient temperature: –40°C to +85°C –40°F to +185°F;
3
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. applied voltage
(at 20°C 68°F)
130%V of
nominal voltage
REFERENCE DATA
1. Max. switching power 2. Life curve 3. Coil temperature rise
10
5
1
Contact current, A
0.1 10 100
Contact voltage, V
AC resistive load
100
4
250V AC resistive load
Life, ×10
10
1
125V AC resistive load
6543210
Contact current, A
Sample: ALDP112, 6 pcs. Point measured: inside the coil Contact current: 0 A, 5 A
50
40
30
Temperature rise, °C
20
10
Coil applied voltage, %V
*at room temperature
5A* 0A*
85°C 5A 85°C 0A
14012010080
–2–
ASCTB193E 201603-T
Page 3
LD-P (ALDP1)
mark can be downloaded from: http://industrial.panasonic.com/ac/e/The CAD data of the products with a
4-(1). Operate time
Sample: ALDP112, 30 pcs.
10
8
6
Operate time, ms
4
2
0
Coil applied voltage, %V
5. Electrical life test (5A 250V AC Resistive load)
Sample: ALDP112, 6 pcs. Operation frequency: 20 times/min. (ON:OFF = 1.5s:1.5s)
Circuit:
250V AC
12V DC
Max.
Min.
1401201008060
Contact welding
detection and
Mis-contacting
4-(2). Release time (without diode)
Sample: ALDP112, 30 pcs.
10
8
6
Release time, ms
4
2
0
Coil applied voltage, %V
Max. Min.
1401201008060
4-(3). Release time (with diode)
Sample: ALDP112, 30 pcs.
10
8
6
Release time, ms
4
2
0
Change of pick-up and drop-out voltage Change of contact resistance
100
90
80
70
60
50
40
Contact resistance, mΩ
30
20
10
0
detection circuit
10
9
8
7
6
5
4
3
Pick-up and drop-out voltage, V
2
1
0
Pick-up voltage
Drop-out voltage
No. of operations, ×10
Max.
Min.
Max. Min.
100
4
Coil applied voltage, %V
No. of operations, ×10
Max.
Min.
4
1401201008060
Max.
Min.
100
DIMENSIONS (mm inch)
Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch:
0.4 dia.
.016 dia.
1.05
.041
External dimensions
Max. 20.5
Max. .807
0.4
.016
0.2
.008
11.5 7.0
.453 .276
0.2
.008
Max. 15.3
Max. .602
3.4
.134
0.8
.031
4.7
.185
General tolerance
±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012
Max. 7.2
Max. .283
1.15
.045
PC board pattern (Bottom view)
11.5
(1.15)
(.045)
4.7
.185
.453
(1.05)
(.041)
7.0
.276
4-1.1 dia.
4-.043 dia.
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
NOCOM
COIL
–3–
ASCTB193E 201603-T
Page 4
LD-P (ALDP1)
SAFETY STANDARDS
UL/C-UL(Recognized)*
File No. Load Temp. Cycles File No. Load Temp. Cycles File No. Load Temp. Cycle
5A 277V AC Resistive
5A 30V DC Resistive
6A 277A AC 5 × 10
E43028
Notes: *1. CSA standard: Certified by C-UL
3A 277V AC General use
5A 277V AC Resistive*
Pilot duty, C300
Pilot duty,
0.65A 277V AC (Inrush 6.5A)
*2. For Insulation Class F models only (Coil class F)
2
1
85°C
185°F
–10
85°C
185°F
105°C
221°F
85°C
185°F
85°C
185°F
10
12 × 10
5 × 10
10
10
5
5
4
4
4
5
5
40014384
VDE (Certified) CQC
5A 250V AC
φ
=1.0)
(cos
5A 30V DC (0ms)
5A 250V AC
φ
=1.0)*
(cos
——— ——
——— ——
——— ——
——— ——
85°C
185°F
25°C
77°F
105°C
2
221°F
10
10
5 × 10
5
4
4
CQC10002048611
5A 250V AC
——
——
85°C
185°F
4
10
EN/IEC VDE Certified INSULATION CHARACTERISTIC (IEC61810-1)
Item Characteristic
Clearance/Creepage distance (IEC61810-1) Min. 5.5mm/5.5mm
Category of protection (IEC61810-1) RTIII
GWT (IEC60335-1) GWFI850/GWT750 2s (base)/GWIT775 (cover)
Tracking resistance (IEC60112) PTI175
Insulation material group IIIa
Over voltage category III III
Impulse Withstand Voltage 4 kV 6 kV
Rated voltage 250V 250V
Pollution degree 32
Type of insulation (Between contact and coil) Basic Insulation Reinforced Insulation
Type of insulation (Between open contact) Micro Disconnection
NOTES
1. For cautions for use, please read “GENERAL APPLICATION GUIDELINES”.
2. Usage, transport and storage conditions
1) Temperature: –40 to +85°C –40 to +185°F
2) Humidity: 5 to 85% RH (Avoid freezing and condensation.) The humidity range varies with the temperature. Use within the range indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for usage, transport, and storage
Humidity, %RH
85
Tolerance range
(Avoid freezing when used at temperatures lower than 0°C 32°F)
(Avoid condensation when used at temperatures higher than 0°C 32°F)
5
Temperature, °C °F
850–40
+185+32–40
3. Certification
1) This relay is UL/C-UL certified. UL/C-UL standards: 5 A 277 V AC 85°C 185°F 5 A 30 V DC
2) This relay is certified by VDE. VDE standards: 5 A 250 V AC cos
φ
= 1.0 85°C 185°F
5 A 30 V DC 0ms
3) UL/C-UL and VDE certified ratings are displayed on the packaging box. (On the relay, only the certification marks are shown and not the certified ratings. Please refer to the product specification diagrams to see what is stamped.)
4. Part number display
The “W” at the end of the part number only appears on the inner and outer packaging. It does not appear on the relay itself.
5. Creepage distance and clearances between contact and coil: Min. 6 mm
.236 inch
–4–
ASCTB193E 201603-T
Page 5
LD-P (ALDP1)
–5–
ASCTB193E 201603-T
Loading...