Datasheet AEV25324, AEV25312, AEV25124, AEV25112, AEV25024 Datasheet (NAIS)

...
Page 1
346
EV-RELAYS
COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY.
150A 2a 150A 1a
60a 30a
FEATURES
• Small size & light weight: size 1/4, weight 1/2(compared to conventional contactors)
• No arc space is required: size includ­ing arc space 1/9 (compared to con­ventional contactors)
The arc is not exposed to the outside, therefore, no arc space is not required.
• Safety construction
The arc is not exposed, therefore, the contactor is explosion proof and intrinsi­cally safe.
• Quiet: operation noise 1/4 (compared to conventional contactors).
Along with the above-mentioned miniatur­ization, the operation noise has been re­duced to 70dB, and, in addition, the
operation noise remains unchanged when a current of 1000A or more is inter­rupted.
• High contact reliability
The contact part is hermetically sealed with H
2
mixed gas, hence the contact re­sistance remains stable regardless of the ambient conditions.
• Mounting direction is not specified
The weight of the movable parts is light, and also the restoring force is large, hence the contactor is relatively unaffect­ed by gravity.
• Line-up of indicator Type (150A Type only)
A line-up of relays with indicator that can monitor the relay operation.
SPECIFICATIONS
Contact
Characteristics
Type 150A type 60A type 30A type Arrangement 1 Form A, 2 Form A 1 Form A 1 Form A
Rating
Nominal switching capacity (resistive load)
150A 400V DC
60A 400V DC 30A 400V DC
Short term current 300A (10min) (40mm
2
) 120A (15min) (15mm
2
) 60A (5min) (5.5mm
2
)
Max. cut-off current
2,500A 300V DC
(3 cycles)
#1
600A 300V DC
(5 cycles)
Overload opening/closing rating
600A 300V DC
(25 cycles)
120A 400V DC
(50 cycles)
120A 400V DC
(50 cycles)
Contact voltage drop (Max.)
0.1V (When current
(is 150A
per 1)
contact set)
0.1V (When current (is 60A per 1) contact set)
0.2V (When current (is 30A per 1) contact set)
Nominal operating power
35W (Inrush, approx 0.1s)
5W (Stable)
Max. 5W Max. 5W
Expected life (min. operations)
Mechanical
1 Form A: 10
5
2 Form A: 5 × 10
4
10
5
Electrical
150A 400V DC
10
3
L/R
q
1ms
60A 400V DC 10
3
L/R
q
1ms
30A 400V DC 3 × 10
4
L/R
q
1ms
Initial insulation resistance Min. 100 M Ω (at 500 V DC)
*1
Initial breakdown voltage
Between open contacts AC 2,500 Vrms for 1 min.
*2
Between contact and coil AC 2,500 Vrms for 1 min.
*2
Operate time (at 20 ° C) (at nominal voltage) Max. 50ms
*3
Reset time (without diode) (at 20 ° C) (at nominal voltage) Max. 30ms
*4
Shock resistance
Functional Min. 196 m/s
2
{20 G}
*5
Destructive Min. 490 m/s
2
{50 G}
*6
Vibration resistance
Functional 43 m/s
2
{4.4 G} 10 to 200Hz
*7
Destructive 43 m/s
2
{4.4 G} 10 to 200 Hz
*8
Conditions for operation, transport and storage (Not freezing and condensing at low temperature)
Ambient temperature –40 ° C to +80 ° C –40 ° F to +176 ° F
*9
Humidity 5 to 85% R.H.
Unit weight
150 A 1 Form A: 660 g 21.16oz 150 A 2 Form A: 1,100 g 38.80oz
60 A: 330 g 11.64oz 30 A: 310 g 10.93oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*1
Measurement at same location as "Initial breakdown voltage" section.
*2
Detection current: 10mA.
*3
Nominal voltage applied to the coil,excluding bounce time.
*4
Nominal voltage applied to the coil.
*5
Half-wave pulse of sine wave: 11 ms; detection time: 10 µ s.
*6
Half-wave pulse of sine wave: 6 ms.
*7
Detection time: 10 µ s.
*8
3 directions, each 4 hours.
*9
Storage: Max.85 ° C 185 ° F.
Notes:
Same specifications as the 12 V type.
#1
Condition: Nominal switching 100cycles, each cut off 2,500A
Page 2
EV
347
Indicator ratings
Note:
Indicator type is only available for the 150 A type.
Arrangement 1 Form A 1 Form B Material Gold-clad Rating (resistive load) 0.1 A 30 V DC Contact resistance Max. 100 m M Ω
TYPICAL APPLICATIONS
• Electric Vehicle
• Hybrid Electric Vehicle
ORDERING INFORMATION
Product Name
EV
Contact arrangement Contact rating Coil voltage
1: 1 Form A 2: 2 Form A
3: 30A 5: 150A 6: 60A
0: without indicator contact 1: a contact (150A type only) 3: b contact (150A type only)
Indicator contact
arrangement
12: 12V DC 24: 24V DC
Ex. A EV 1 5 0 12
Packing quantity
Types Inner Outer 150A 2 Form A 1pc. 5pcs. 150A 1 Form A 1pc. 10pcs. 60A 1 Form A 1pc. 20pcs. 30A 1 Form A 1pc. 20pcs.
SPARE PARTS
Installing parts Part No. Packing Quantity M8 nut with washer for 150A type AEV801 2pcs. M5 screw for 60A type AEV802 2pcs. M4 screw for 30A type AEV803 2pcs. Bus bar for 60A type AEV804 1pcs.
TYPES AND COIL DATA (at 20 ° C 68 ° F)
Note:
* Same coil data as Indicator type.
Part No.
Coil voltage,
V DC
Pick-up voltage,
V DC (max.)
Drop-out voltage,
V DC (min.)
Nominal coil current, mA
( ± 10%)
Operating power,
W (12 V DC)
Max. allowable
voltage,
V DC
AEV25012*
12 V DC 9 V DC 1 V DC
2.8 A (at peak)*
35W (Inrush, approx. 0.1S)
5W (Stable)
16 V DC
AEV15012* AEV16012
0.415 A Max. 5W
AEV13012 AEV25024*
24 V DC 18 V DC 2 V DC
1.9 A (at peak)*
35W (Inrush, approx. 0.1S)
Max. 5W (1 Form A) Max. 6W (2 Form A)
32 V DC
AEV15024* 2.2 A (at peak)* AEV16024
0.208 A Max. 5W
AEV13024
Page 3
EV
348
DIMENSIONS
150A 2a
2.992±.012
76.0±0.3
1.063
2.598
3.465
88.0
66.0
27.0
.138
3.5
+
-
3 1
1
3
+
-
3
2
9
4
1
5
Z
8
6
Y
7 X
9
8
+
-
2
4
2
4
+
-
2
3
9
4 1
5
Z
8
6
Y
7 X
8
9
75.0±0.3
.551
29.0
5
34.0
3.425
11.811±.394
300±10 (lead wire
)
2.268
.524
3.429
2.894
2.874
73.0
73.5
87.1
57.6
13.3
V+/AVX(White) wire diameter 0.5sq
GND/AVX(Green) wire diameter 0.5sq
2.953±.012
M8nut:AEV801
.197
1.142
1.339
87.0
14
4-.209±.004 dia
4-5.3±0.1 dia
Schematic (TOP VIEW)
Mounting dimensions
Coil( ) Coil( )
2
4
1
3
76
2.992
4-.209 dia
4-5.3 dia
75
2.953
Gener
al tolerance: less than 10 (.394) ± 0.3 ( ± .012) 10 (.394) to 50 (1.969) ± 0.6 ( ± .024) more than 50 (1.969) ± 1.0 ( ± .039)
mm inch
150A 2a Indicator Type
NC/AVX(Red) wire diameter 0.5sq/AEV25312,25324 COM/AVX(Black) wire diameter 0.5sq
NO/AVX(Blue) wire diameter 0.5sq/AEV25112,25124
GND/AVX(White) wire diameter 0.5sq
V+/AVX(Green) wire diameter 0.5sq
2.992±.012
76.0±0.3
1.063
2.598
3.465
88.0
66.0
27.0
.138
3.5
+
-
3 1
1
3
+
-
3
2
9
4 1
5
Z
8
6
Y
7
X
9
8
+
-
2
4
2
4
+
-
2
3
9
4 1
5
Z
8
6
Y
7 X
8
9
75.0±0.3
.551
29.0
5
34.0
3.425
11.811±.394
300±10(lead wire
)
.524
3.429
2.894
2.874
73.0
73.5
87.1
13.3
2.953±.012
M8nut:AEV801
.197
1.142
1.339
87.0
14
4-.209±.004 dia
4-5.3±0.1 dia
6
.236
Schematic (TOP VIEW)
Mounting dimensions
Coil(+) Coil(–)
2 – Indicator: NO or NC Indicator: COM
4 +
1 +
3 –
76
2.992
4-.209 dia
4-5.3 dia
75
2.953
Gener
al tolerance: less than 10 (.394) ± 0.3 ( ± .012) 10 (.394) to 50 (1.969) ± 0.6 ( ± .024) more than 50 (1.969) ± 1.0 ( ± .039)
Page 4
EV
349
150A 1a
M8nut:AEV801
2.992±.012
76.0±0.3
1.063
2.520
2.913
3.465
27.0
64.0
88.0
74.0
.138
3.5
V+/AVX(Green) wire diameter 0.5sq GND/AVX(White) wire diameter 0.5sq
1
+
3
2
9
4
1
5
Z
8
6
Y
7 X
8
9
2
-
2
3
9
4 1
5
Z
8
6
Y
7 X
8
9
1
2
+
-
19.5
1.142
.551
41.0±0.3
6
3.429
13.3
57.6
2.894
2.874
11.811±.394
2.268
87.1
.524
73.5
73.0
300±10(lead wire
)
.768
29.0
1.614±.012
53.0
2.087
14
.236
2-.209±.004 dia
2-5.3±0.1 dia
Schematic (TOP VIEW)
Mounting dimensions
Coil( ) Coil( )
21
2.992
76
2-.209 dia
2-5.3 dia
1.614
41
Gener
al tolerance: less than 10 (.394) ± 0.3 ( ± .012) 10 (.394) to 50 (1.969) ± 0.6 ( ± .024) more than 50 (1.969) ± 1.0 ( ± .039)
mm inch
150A 1a Indicator Type
NC/AVX(Red) wire diameter 0.5sq/AEV15312,15324 COM/AVX(Black) wire diameter 0.5sq
NO/AVX(Blue) wire diameter 0.5sq/AEV15112,15124
GND/AVX(White) wire diameter 0.5sq
V+/AVX(Green) wire diameter 0.5sq
M8nut:AEV801
2.992±0.012
76.0±0.3
1.063
2.520
2.913
3.465
27.0
64.0
88.0
74.0
.138
3.5
1
+
3
2
9
4 1
5
Z
8
6
Y
7 X
8
9
2
-
2
3
9
4 1
5
Z
8
6
Y
7 X
8
9
1
2
+
-
19.5
1.142
.551
41.0±0.3
6
3.429
13.3
2.894
2.874
11.811±.394
87.1
.524
73.5
73.0
300±10(lead wire
)
.768
29.0
53.0
2.087
14
.236
2-0.209±.004 dia
2-5.3±0.1 dia
1.614±.012
0.5
.020
Schematic (TOP VIEW)
Mounting dimensions
Coil(+) Coil(–)
2 –1 +
Indicator: NO or NC Indicator: COM
2.992
76
2-.209 dia
2-5.3 dia
1.614
41
Gener
al tolerance: less than 10 (.394) ± 0.3 ( ± .012) 10 (.394) to 50 (1.969) ± 0.6 ( ± .024) more than 50 (1.969) ± 1.0 ( ± .039)
Page 5
EV
350
60A
2-.209±.004 dia
2-5.3±0.1 dia
2.402±.012
61.0±0.3
1.772
3.146
1.929
2.480
2.874
45.0
79.9
73.0
63.9
49.0
M5screw:AEV802
V+.GND/AEX(Gray) wire diameter 0.5sq
*Input coil wire is not polarized
1 +
3
2
9
4 1
5
Z
8
6
Y
7 X
8
9
2
3
9
4 1
2
5
Z
-
8
6
Y
7 X
8
9
.512
26.0±0.3
30.2
38.0
11.811±.394
300±10(lead wire
)
1410
62.0
2.795
M4screw(installed
)
.551.394
2.441
71.0
14.5
13.0
1.024±.012
1.189
1.496
.571
(
terminal height
)
Schematic (TOP VIEW)
(60A)
output side has polarities (+) and (-)
Mounting dimension
Coil
21
61
2.402
2-5.3 dia
2-.209
dia
26
1.024
Gener
al tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)
mm inch
30A
2-.209±.004 dia
2-5.3±0.1 dia
M4screw:AEV803
2.402±.012
61.0±0.3
.705
1.772
1.929
2.874
17.9
45.0
49.0
73.0
.098
2.5
30±10(lead wire
)
11.811±.394
+
1
3
2
9
4 1
5
Z
8
6
Y
7 X
8
9
3
2
9
4 1
5
2
Z
-
8
6
Y
7 X
8
9
.394
.551
14.5
62.5
2.795
71.0
2.461
.571
10
*Input coil wire is not polarized
V+GND/AEX(Gray) wire diameter 0.5sq
14.0
1.024±.012
26.0±0.3
30.2
1.189
38.0
1.496
(
terminal height
)
Schematic (TOP VIEW)
(60A)
output side has polarities (+) and (-)
Mounting dimension
Coil
21
61
2.402
2-5.3 dia
2-.209
dia
26
1.024
General tolerance: less than 10 (.394) ±0.3 (±.012) 10 (.394) to 50 (1.969) ±0.6 (±.024) more than 50 (1.969) ±1.0 (±.039)
REFERENCE DATA
1-(1) Ambient temperature characteristics
Sample: AEV15012,3pcs
1-(2) Ambient temperature characteristics
Sample: AEV16012,3pcs
x
­x
-
x
-
10
8 6 4 2
-40
-20
20
-6
-2
-4
-8
-10
6040 80
0
Pick-Up voltage
Ambient temperature,
Variation ratio, %
Drop-out voltage
Operate time
C
x
-
x
-
x
-
Pick-Up voltage
Ambient temperature,
Variation ratio, %
40
30
20
10
-40
-20 20
-10
-20
-40
6040 80
0
Drop-out voltage
Operate time
C
-30
Page 6
EV
351
NOTES
1. When installing the rela y , al ways use washers to prevent loosening of the screws.
Tighten each of the screws within the rat­ed ranges given below. Exceeding the maximum torque may result in breakage. Mounting is possible in either direction.
• M8 screw (for 150 A main terminal): 10 to 15 Nm
• M5 screw (150 A, 60 A, 30 A main unit mounting section) (60 A main terminal): 2.5 to 3.6 Nm
• M4 screw (30 A terminal): 1.8 to 2.7 Nm
2. The coils (150 A type) and contacts (30 A, 60 A, 150 A) of the relay are po­larized, so follow the instructions in the connection schematic when con­necting the coils and contacts.
Type 150 A has contains a reverse surge voltage absorption circuit; therefore a surge protector is not needed. We recommend installing a surge protec­tor varistor (ZNR) for the 30 A and 60 A types. Avoid using a diode as this may re­sult in decreased cut-off capability.
3. As a general rule, do not use a rela y if it has been dropped.
4. Avoid mounting the relay in strong magnetic fields (near a transformer or magnet) or close to an object that radi­ates heat.
5. Electrical life
This relay is a high-voltage direct-current switch. In its final breakdown mode, it ma y lose the ability to provide the proper cut­off. Theref ore, do not exceed the indicated switching capacity and life. (Please treat
the relay as a product with limited life and replace it when necessary.) In the event that the relay loses cut-off ability, there is a possibility that burning may spread to surrounding parts, so con­figure the layout so that the power is turned off within one second. When using the 30 A type, to prevent in­creases in the contact resistance, do not allow switching without any load.
6. Permeation life of internal gas
This relay uses a hermetically encased contact (capsule contact) with gas inside. The gas has a permeation life that is af­fected by the temperature inside the cap­sule contact (ambient temperature + temperature rise due to flow of electrical current). For this reason, make sure the ambient operating temperature is be­tween –40 and 80°C –40 and +176°F, and the ambient storage temperature is be­tween –40 and 85°C –40 and +185°F.
7. If the power is turned off and then im­mediately on after applying the rated volt­age (current) continuously to the relay's coil and contact, the resistance of the coil will increase due to a rise in the coil tem­perature. This causes the pick-up voltage to rise, and possibly exceed the rated pick-up voltage. In these circumstances, take measures such as reducing the load cur­rent, limiting the duration of current flow, and applying a coil voltage higher than the rated operating voltage (quick start).
8. Main contact ratings in the ratings apply to when there is a resistive load.
9. If you are using an inductive load (L load) such that L/R > 1 ms, add surge pro­tection in parallel with the inductive load. If this is not done, the electrical life will de­crease and cut-off failure may occur.
10. When using the 150 A type, mount it as far away as possible from amateur wireless transmitters or devices that may generate large surges. To prevent malfunctioning due to high emission levels, it may be neccessary to take measures for E.M.I., such as adding a line noise filter or an electromagnetic shield.
11. Since coil current control is per­formed, a slight amount of superimposed line noise may be generated in the input line system. If this noise must be re­moved, install a line noise filter.
12. Be careful that foreign matter and oils and fats kind doesn't stick to the main terminal part because it is likely to cause a terminal part to give off un­usual heat.
13. A void excessive load applied to the terminal in case of installing such as a bus bar etc., because it might give bad influence to the opening and closing performance.
• M8 screw terminal (150A main terminal part) Terminal pulling up strength; Max.100N per terminal The up-down rotation torque applied to the terminal; Max.15N·m
9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog
Loading...