Datasheet AED100US48, AED100US19, AED100US18, AED100US12 Datasheet (IPSI)

Page 1
Input
Input Voltage 90-264 VAC Input Frequency 47-63 Hz Inrush Current 50 A @ 115 VAC,
100 A max at 264 VAC
Input Current 1.10 A max at 115 VAC,
0.55A max at 230 VAC
Output
Output Voltage 12-48 VDC Output Power 100 Watts Minimum Load 0 minimum load required Line Regulation ±1% max Load Regulation See Table Set Point Accuracy ±2% max Ripple & Noise ±1% max (peak-peak) Transient Response 4% max deviation, 500µs recovery
time for a 25% load change
Temperature ±0.04%/°C Coefficient
Hold Up Time 20 ms minimum at 115 VAC Overvoltage 110% to 130% with auto recovery
Protection Overcurrent 120% to 140% with auto recovery
Protection
General
Efficiency 85% typical Power Density 4.4 W/in
3
Withstand Voltage 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground MTBF 100,000 hrs min per MIL-HDBK-217F Size 2.76” x 5.91” x 1.38”
Weight 520 grams
Environmental
Operating 0°C to +65°C with derating Temperature Derate linearly from 100% load
at 50°C to 0% load at 65°C Relative Humidity 5% to 95%, non condensing Storage Temperature • -20 °C to +85 `°C
EMC & Safety
EMI/EMC EN55022, CISPR22 and
FCC Class B conducted and radiated
CE Mark Safety Approvals UL1950, CSA C22.2 No 234 per cUL
EN60950
100 Watts
AED100 Series
AC/DC External Desktop
Specification
Intelligent Design Quality Product
XPiQ inc.
CE Marked For EMC & LVD
Active PFC - Meets EN61000-3-2, -3
High Efficiency - 85% Typical
High Power Density
Small Size, Low Profile
Overvoltage & Short Circuit Protected
International Safety Approvals
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
Page 2
Vnom Imin Imax Total Regulation Maximum Output Model
Power Number 12 V 0 A 8.33 A 4% 100 W AED100US12 15 V 0 A 6.67 A 4% 100 W AED100US15 18 V 0 A 5.56 A 2% 100 W AED100US18 19 V 0 A 5.26 A 2% 100 W AED100US19 24 V 0 A 4.17 A 2% 100 W AED100US24 48 V 0 A 2.08 A 2% 100 W AED100US48
OUTPUT VOLTAGE & CURRENT RATINGS AED100
Mechanical Details
Derating Curve
NOTES
1. Dimensions shown in mm (inches).
2. Tolerance 0.5 (0.02) maximum.
3. Output connector is 5.5mm outer diameter barrel. Inner diameter is
2.5mm with center positive (+)/outer shell negative (-) polarity.
4. Cable length for AED100US12 and US15 is 1219 mm (48”) typical, other models is 1800mm (70”) typical.
5. Optional output connectors available.
* Total regulation includes initial tolerance, line regulation and load regulation.
Note
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com